DESIGN LOADS:

DEAD LOAD:
BITUMINOUS PRODUCT
CERAMIC TILES 23.60 KPa
CEILING
ACOUSTICAL FIBER BOARD 0.05
KPa
PLASTER OR TILE ON CONCRETE 0.24
KPa
FLOOR FILL
LIGHTWEIGHT CONCRETE, PER 0.0!5
KPa
FLOOR AND FLOOR FINISHES
CEMENT FINISH "25# ON STONE$CONCRETE FILL
!.53 KPa
CERAMIC OR %UARR& TILE "20# 25 MORTAR BED !.!0
KPa
FRAME WALLS
WINDOWS, GLASS, FRAME AND SASH 0.3'
KPa
HOLLOW CONCRETE MASONR& !50 THICKNESS "!(.6 KN)M3#
2.35 KPa
ELECTRICAL)MECHANICAL 0.!0
KPa
SLAB 4.'0 KPa
PARTITION LOADS !.0
KPa
FRAME PARTITIONS
WOOD STUDS 50*!00 PLASTERED TWO SIDES
0.(6 KPa
LI+E LOAD:
ASSEMBL& AREAS AND AUDITORIUM AND BALCONIES THEREWITH
MO+ABLE SEATING 4.'0
KPa
E*IT FACILITIES 4.'0
KPa
RESIDENTIAL
BASIC FLOOR AREA !.(0
KPa
E*TERIOR BALCONIES 2.(0
KPa
RESTROOM !.(0 KPa
PARTITIONS AND INTERIOR WALL
0.25 KPa
CEILING FRAMING !.00
KPa

PRELIMINAR& SI,ING
BEAMS: 400*400
COLUMNS: 500*500
SLAB THICKNESS: 0.2