You are on page 1of 10

# Ammonit Data Logger - System Information

# ----------------------------------------
#
# Data Logger Type Meteo-40S
# Serial Number D130128
# Number of Channels 4 Analog Voltage, 4 Counters, 1 Analog Current
, 1 Current Sources, 2 Digital, 2 Switches, 8 RS-485
# Data Logger Position 0.0,0.0 @ 0.0m
# RAM Total: 123MB, Used: 58MB, Free: 65MB
# Source Data Memory 981.51MB (100.00% used, page-id: 3135167)
# System Memory Total: 450MB, Used: 123MB, Free: 322MB
# Software Version 1.0 Rev. 13187 (2013-07-01)
# Bootloader Version 10394
# Current Connections Admin (213.233.84.122 T)
[EMail]
to=wm-erbiceni@anemos.de
from=wm-erbiceni@anemos.de
username=wm-erbiceni@anemos.de
server=mail.anemos.de
cc=r.hilsenbeck@wsb.de; g.condrea@wsb.ro
port=25
[Heating]
temperature_sensor=none
switch_id=none
humidity_sensor=none
temperature_min=-10
temperature_max=2
humidity_min=70
[M1]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M2]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M3]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M4]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M5]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M6]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M7]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[M8]
statistics=avg_scalar,min,max,stddev,count
protocol_type=None
sensor=0
address=0
modbus_register_quantity=1
sensor_type=THIES_4_387x_xx_xxx_TR4
active=false
modbus_function_code=4
modbus_start_register=0
[AC1]
sensor=0
switch_pretime=1 min
statistics=avg_scalar,min,max,stddev,count
rate=1 s
active=false
switch_active=false
switch_id=S1
range=100 mA
[Ethernet]
use_dhcp=false
addsubnet=
subnet_mask=255.255.255.0
switch_id=none
dns_server=192.168.40.1
ip_address=192.168.40.40
never_default=true
gateway=192.168.40.1
permanent=true
[CSVFilesGenerate]
quantity=1
time_start=12:00
active=true
weekdays=mon,tue,wed,thu,fri,sat,sun
time_interval=06:00
[WLAN]
firstaddr=192.168.40.2
passphrase=
ip_address=192.168.40.1
netmask=255.255.255.0
network=192.168.40.0
lastaddr=192.168.40.255
active=true
[System]
use_ntp=false
timezone=UTC
use_camera=false
display_permissions=dhcp,rec_on,wlan
altitude=0.0
camera_url=
latitude=0.0
loggername=Erbiceni
cecs_power_permanent=false
ntpserver=0.pool.ntp.org 1.pool.ntp.org 2.pool.ntp.org 3.pool.ntp.org
use_gps=false
longitude=0.0
[ServerCopy]
port=0
method=scp
server=upload.ammonit.com
username=upload
directory=GCYK
[A1]
range=10 V
sensor=0
switch_pretime=1 min
rate=1 s
active=true
statistics=avg_scalar,min,max,stddev,count
switch_active=false
switch_id=S1
[A2]
range=1 V
sensor=0
switch_pretime=1 min
rate=1 s
active=true
statistics=avg_scalar,min,max,stddev,count
switch_active=false
switch_id=S1
[A3]
range=1 V
sensor=0
switch_pretime=1 min
rate=1 s
active=true
statistics=avg_scalar,min,max,stddev,count
switch_active=false
switch_id=S1
[A4]
range=10 V
sensor=0
switch_pretime=1 min
rate=1 s
active=false
statistics=avg_scalar,min,max,stddev,count
switch_active=false
switch_id=S1
[ModemGSM]
bsd-comp=false
username=internet.vodafone.ro
apn=internet.vodafone.ro
permanent=true
number=*99#
switch_id=S1
deflate-comp=false
vj-comp=false
[SCADA]
interval=10 min
protocol_type=Modbus TCP
port=502
word_endianness=high_first
id=1
active=false
byte_endianness=high_first
serial_setting=9600 8N1
allowed=
[C1]
rate=1 s
statistics=avg_scalar,min,max,stddev,count
switch_active=false
sensor=0
switch_id=S1
switch_pretime=1 min
active=true
[C2]
rate=1 s
statistics=avg_scalar,min,max,stddev,count
switch_active=false
sensor=0
switch_id=S1
switch_pretime=1 min
active=true
[C3]
rate=1 s
statistics=avg_scalar,min,max,stddev,count
switch_active=false
sensor=0
switch_id=S1
switch_pretime=1 min
active=true
[C4]
rate=1 s
statistics=avg_scalar,min,max,stddev,count
switch_active=false
sensor=0
switch_id=S1
switch_pretime=1 min
active=true
[D1]
switch_pretime=1 min
active=true
rate=1 s
sensor=0
switch_id=S1
protocol=thies10bit
switch_active=false
statistics=avg_scalar,min,max,stddev,count
[D2]
switch_pretime=1 min
active=true
rate=1 s
sensor=0
switch_id=S1
protocol=thies10bit
switch_active=false
statistics=avg_scalar,min,max,stddev,count
[ActionOnline]
time_start=10:00
time_interval=2:00
minimal_runtime=1:00
weekdays=mon,tue,wed,thu,fri
quantity=2
active=true
[Evaluation]
stat_interval=10 min
order=1,2,3,4,8,9,7,6,5
file_interval=daily
[Master]
serial_setting=9600 8N1
rate=1 s
[Online]
tunnel_port=0
project_key=
tunnel_affix=
tunnel_login=logger@D130128.tunnel.ammonit.com
tunnel_active=true
tunnel_active_only_online_action=false
[ActionCopy]
time_start=06:00
weekdays=mon,tue,wed,thu,fri,sat,sun
quantity=1
active=true
time_interval=0:00
[ActionEMail]
active=true
time_start=06:00
weekdays=mon,tue,wed,thu,fri,sat,sun
quantity=1
time_interval=0:00
[Eval_1]
channels=1
var_offset=0.2464
slope_unit=m/s/I
name=wind_speed
active=true
slope_hint=~0.0462
offset_hint=~0.21
formula=linear_cnt
label=Anemometer
var_slope=0.04592
offset_unit=m/s
var_period=1
sensors=1
unit=m/s
statistics=avg_scalar,max,min,stddev,count
formula_params=C1,var_period,var_offset,var_slope
[Sensor_1]
serial_number=04133228
used_channels=C1
active=true
rate=1 s
type=anemometer
model=Thies Anemometer First Class Advanced
label=Anemometer
order=S11100/S11100H
evals=1
height=103.5
[Eval_2]
channels=1
var_offset=0.2377
slope_unit=m/s/I
name=wind_speed
active=true
slope_hint=~0.0462
offset_hint=~0.21
formula=linear_cnt
label=Anemometer 2
var_slope=0.04593
offset_unit=m/s
var_period=1
sensors=2
unit=m/s
statistics=avg_scalar,max,min,stddev,count
formula_params=C2,var_period,var_offset,var_slope
[Sensor_2]
serial_number=04133151
used_channels=C2
active=true
rate=1 s
type=anemometer
model=Thies Anemometer First Class Advanced
label=Anemometer 2
order=S11100/S11100H
evals=2
height=102
[Eval_3]
channels=1
var_offset=0.2411
slope_unit=m/s/I
name=wind_speed
active=true
slope_hint=~0.0462
offset_hint=~0.21
formula=linear_cnt
label=Anemometer 3
var_slope=0.04586
offset_unit=m/s
var_period=1
sensors=3
unit=m/s
statistics=avg_scalar,max,min,stddev,count
formula_params=C3,var_period,var_offset,var_slope
[Sensor_3]
serial_number=04133148
used_channels=C3
active=true
rate=1 s
type=anemometer
model=Thies Anemometer First Class Advanced
label=Anemometer 3
order=S11100/S11100H
evals=3
height=84
[Eval_4]
channels=1
var_offset=0.2334
slope_unit=m/s/I
name=wind_speed
active=true
slope_hint=~0.0462
offset_hint=~0.21
formula=linear_cnt
label=Anemometer 4
var_slope=0.0459
offset_unit=m/s
var_period=1
sensors=4
unit=m/s
statistics=avg_scalar,max,min,stddev,count
formula_params=C4,var_period,var_offset,var_slope
[Sensor_4]
serial_number=04133149
used_channels=C4
active=true
rate=1 s
type=anemometer
model=Thies Anemometer First Class Advanced
label=Anemometer 4
order=S11100/S11100H
evals=4
height=64
[Eval_8]
channels=1
var_offset=238
active=true
name=wind_direction
offset_unit=
formula=windvane_dig
label=Wind Vane
var_slope=0.3515625
sensors=7
unit=
statistics=avg_vector,stddev_vector,count
formula_params=D1,var_offset,var_slope
[Sensor_7]
serial_number=06130757
used_channels=D1
active=true
rate=1 s
type=wind_vane
model=Thies Wind Vane 10 Bits Serial Synchron
label=Wind Vane
order=S21100H
evals=8
height=100
digital_protocol=thies10bit
[Eval_9]
channels=1
var_offset=240
active=true
name=wind_direction
offset_unit=
formula=windvane_dig
label=Wind Vane 2
var_slope=0.3515625
sensors=8
unit=
statistics=avg_vector,stddev_vector,count
formula_params=D2,var_offset,var_slope
[Sensor_8]
serial_number=06130760
used_channels=D2
active=true
rate=1 s
type=wind_vane
model=Thies Wind Vane 10 Bits Serial Synchron
label=Wind Vane 2
order=S21100H
evals=9
height=80
digital_protocol=thies10bit
[Eval_5]
channels=1
var_offset=800
slope_unit=mbar/V
name=air_pressure
active=true
offset_unit=mbar
formula=linear
label=Barometer
var_slope=60
sensors=5
unit=mbar
statistics=avg_scalar,max,min,stddev,count
formula_params=A1,var_offset,var_slope
[Sensor_5]
needs_switch=1 s
used_channels=A1
serial_number=B130254
active=true
rate=1 s
type=barometer
label=Barometer
model=Barometric Pressure Sensor AB60
switch_pretime=1 s
adc_range_u=10 V
order=P6330.2
evals=5
height=9
[Eval_6]
channels=1
var_offset=-30
slope_unit=C/V
name=temperature
active=true
offset_unit=C
formula=linear
label=Thermo/Hygro
var_slope=100
sensors=6
unit=C
statistics=avg_scalar,max,min,stddev,count
formula_params=A2,var_offset,var_slope
[Eval_7]
channels=2
var_offset=0
slope_unit=%/V
name=humidity
active=true
offset_unit=%
formula=linear
label=Thermo/Hygro
var_slope=100
sensors=6
unit=%
statistics=avg_scalar,max,min,stddev,count
formula_params=A3,var_offset,var_slope
[Sensor_6]
needs_switch=1 s
used_channels=A2,A3
active=true
rate=1 s
type=hygro_thermo
label=Thermo/Hygro
model=Galltec Thermo-Hygro Active KP
switch_pretime=1 s
adc_range_u=1 V
order=P6312
evals=6,7
height=102.5