Test and Research Facilities: Institute of Electrical Energy Systems High Voltage Laboratories
Test and Research Facilities: Institute of Electrical Energy Systems High Voltage Laboratories
Mesystem zur Auswertung
Schematic representation of the aging test stand
Measuring system for evaluation
2.2 Temperature measurement with passive remote
surface acoustic wave (SAW) sensors
Temperature range -20 - +150C
Measuring accuracy of the SAW-sensor chips -+0.5C
Dimensions of the SAW-sensor chips ca. 1x1.5 cm
Wireless high frequency measuring signal transmission over distances up to approximately
15 meters, also through (non-metallic bodies)
SAW Technique
Receiver unit (power system 12 24 V DC)
2,45 GHz receiver antenna
passive SAW-Temperature sensor (SAW-Sensor chip, Sensor antenna, housing)
Picture 1: Components of a SAW system
Picture 2: Operation of a SAW system (DSP Signal processor, NCO Oscillator)
2.3 Optical monitoring with high speed camera and
photo sensing instruments
High speed camera
Photomultiplier
A photomultiplier is a special vacuum tube, in order to strengthen and convert weak light
signals into individual photons and hence into an electrical signal. A photomultiplier consists
of an entrance window, a photocathode and a secondary downstream multiplier. The output
signal of the photomultiplier can be used electrically, like a constant current source.
High speed camera
Redlake Imaging
Motion Scope PCI 2000 SC
Model: 1108-0012
2000 fps
Maximum recording time: 2 sec
Type: H 8249 Series
Spectral response: 185 680 nm
Frequency bandwidth: DC till 200 kHz
Schematic representation, PMT-photomultiplier
2.4 Diagnostics of vacuum in medium voltage vacuum
arc chambers
For the investigation of various factors, e.g. contact material, contact stress, gas composition
and gas pressure, regarding the decreasing function of the field emission as a diagnostic
procedure of vacuum diagnostics, a test vacuum arc chamber was developed.
Test vacuum arc chamer:
The test vacuum arc chamber consists of a fixed and movable contact
support rod. The fixed contact is fastened to a 100CF blanking flange
cap. The movable support rod is welded with another 100CF blanking
flange comer on a metal bellow. 100CF flanges are welded on the
ceramic insulators. Optical monitoring of pre-discharge currents is made
possible by a distance piece with a 35CF flange. The chamber base has a
commercial 100CFT-fitting with two 35CF flanges. These are for the
connection of the pump and for analysis and measuring instruments.
OSCILOSC
SAMPLE
PMT
POWER
SUPPLY
OPE
Vacuum pump stand:
Commercial vacuum arc quenching chambers exhibit an internal chamber pressure of p<10-7
mbar. In order to achieve the same pressure conditions in a test vacuum chamber, a vacuum
pump stand was developed.
Turbo molecular pump:
PFEIFFER-TURBO TPU 510
Pumping rate for
nitrogen N
2
500 l/s
Booster pump two stage rotary pump
Compression for
nitrogen N
2
8 10
8
Final pressure 10
-11
mbar
Revolution speed 60.000 U/min
Weight 30 kg
Booster pump:
Two stage rotary pump: DUO 030 A
Pumping rate for
nitrogen N
2
500 m
3
/h
Final pressure 10
-3
mbar
Nominal connection diameter DN 40 ISO KF
3 Other Laboratory Equipment
3.1 Molding facility for the fabrication of EP-, PUR-resin
and plastic molded materials
Fabrication of insulating components from epoxy resin or
polyurethane resin molded materials with a vacuum molding
system (Hbers make, type Epsilon).
Technical data
- Volume of vacuum mixer: .....................................................................................3 l
- Internal volume of the vacuum tank: .......................................500 x 700 x 850 mm
- Vacuum pump volume: ................................................................................ 27 m
3
/h
- Mixer heating temperature:....................................................................max. 130 C
3.2 Shielding room
Non-portable shielding rooms ............................. fabricated by Siemens and In-house,
....................................................................... max 200 m
3
.............................................. high shielding effectiveness
3.3 Heating cabinet/oven
Various heating cabinets of different dimensions...................................... up to 1100 C
3.4 Equipment for student laboratory work
MWB-modular system.......................................................... impulse voltage till 280 kV
........................................................................... AC voltage till 200 kV
......................................................................... DC voltages till 280 kV
Test transformers in the high voltage range ...............................................up to 200 kV
...................................... up to 100 kVA
..........Cascade usage partially possible
Resistances, capacitors ............................................... dielectric strength till 140 kV DC
3.5 Physical instruments
Various thermostats, working range: -30 ...+150 C
Instruments for the measurement of: .......................... - Volume conductivity of liquids
- Humidity
Various electronic scales (1/100 g measuring accuracy)
Precision scale, Sartorius make (Type 2842), measuring accuracy +/- 0.1 mg; max. 160g
SF
6
handling equipment (DILO) for pure SF
6
4 Measuring instrument and facilities
4. 1 Transient recorder
Several transient recorders and digital memory oscilloscopes with scanning rates up to 2
GS/s and memory up to 1 MB/channel.
4.2 Optical fiber transmission circuits
Several fiber optic cable transmission circuits for galvanic isolated measurement with
system bandwidths of 5 MHz, 15 MHz and 100 MHz.
4.3 Voltage measurements
Broadband voltage measurements in medium voltage range.
Voltage measurements up to 3 MV.
4.4 Current measurements
Broadband current measurements with shunts and special current transformers up to 120
kV (continuous).
4.5 Impedance measurement
Impedance measurement from 10 m till 100 M within the range of 5 Hz till 13 MHz.
Recording of magnitude and phase.
4.6 Temperature recording
Recording system for SAW wireless sensors with an operating frequency of 2.45 GHz and
a range of 10 m, various wireless sensors for temperature measurement.
4.7 Electrostatic Voltmeter
-Measurement up to +/- 20 kV DC or peak AC
-Rise time of approx. 5 kV/ms
.