position a wad of Dissolvo paper several inches down int o each sect ion t o be joined. For larger pipes (4" inner diameter and larger), cut the paper into a circle wit h a diameter several inches larger t han the pipe ID for a 6" I D pipe, cut an 8" diameter paper circle. Trace or impress t he pipe inner diameter on the paper and f old on t his line t o f orm a 90 degree lip. Insert the dam int o the pipe with t he lip t owards the weld prep. Peel tape f rom backing and tape dam in place. Punch a small hole in t he dam to f acilit at e t he evacuation of air when purging. For pipes larger than 28" diameter, simply splice two or more sheets of Dissolvo paper t ogether wit h Dissolvo t ape, and proceed as in st eps B, C, and D. Aft er t he dams are in place, Argon or another purge gas may be int roduced through t he root gap with a needle valve connected t o the gas line. If one end of the pipe is accessible, the purge gas may be introduced t hrough a hole at t he lower end of one dam. A vent hole should be made at the upper end of the ot her dam t o allow air and gases t o escape. : cover the open root joint on t he outside of t he pipe wit h t ape t o prevent gas leakage. 2004 Dissolvo, LLC. All Rights Reserved. V1 - 5.24.04