You are on page 1of 11

RFID

Access Control System


Users Manual
Please read this manual thoroughly before installation.
. !rief Product Introduction"
This product is RFID access control system, which is currently one of the advanced
access systems. It uses the latest central process unit (CPU and memory chip of lar!e capacity.
There will "e of no information loss even in case of power failure. It ta#es the latest
$%&&'RD technolo!y, with stron! power of three ways to open door( open "y card read,
open "y card read addin! with password, and open "y password.
The perfect security functions let the users feel much more safe, which include door state
monitorin!, alarm output, safety mode, anti dismantlin!, RFID card and password. )hile its
functions of openin! "utton, close notification, door "ell, to "e connected with *%. and *C.
loc#s "rin! more operatin! easiness to the users.
This product provides access control mode, which is safe and fully automatic, it is an
ideal device for "usiness or!ani+ations, offices, factories, residences and communities.
#. $echnical Features
%o. Item S&ecification
, Power supply DC( -olta!e ,.-,/01 current < /.,'
. &a2 load 'larm output( ,//m' 3lectroloc# output(
4'
5 Dimension ,,6mm,,6mm./mm
7 )ei!ht ,8/!
4 'm"ient temp. 9./6/
6 R$ ./0:/0
; &emory capacity Information of 4// user card, and 4//
passwords
8 Induction distance 4,4C&
: Car type 3& or 3& compati"le card
Status Indications"
'(D Indicators
Status Red LED Green LED
Normal state Flash
Valid ard Li!ht
"n#alid ard Li!ht
$%en Li!ht
&e' (ress Li!ht
(ro!ram )ode Li!ht Flash *re+uent
Set $& Li!ht Li!ht
,larm Flash
-u..er
Status Description <u++
-alid card Two short "eeps <i<i
Invalid card =on! "eep once <i
&e' (ress >hort "eep once <i
Input valid
password
Two short "eeps <i<i
Input wron!
password
=on! "eep once <i
'larm state Continuous lon! "eeps <i<i<i
)
. Setu&"
,. Default value( =o!in password : : : : ,User password , . 5 7
.. 3nter pro!rammin! mode(
Press / Lo!in %ass0ord 1 enter %ro!rammin! mode2
5. Function setup (should "e in pro!rammin! mode(
,. &odify lo!in password.
Press 3 ne0 %ass0ord 1 on*irm ne0 %ass0ord 1
*ote( the new password should "e any 798 fi!ures.
.. 'dd user card.
Press 4 read ard "n%ut ode 1
Note5 the ode should 6e three *i!ures *rom 334 to 7338 0hih
should not du%liate2 9he ode must 6e in%ut8 other0ise the ard 0ill
6e in#alid2 "* add more than one ards8 read the seond ard diretl'
a*ter the *irst three:di!it ode is %ut in 6e*ore %ressin! 1 2
;<2 Delete user ard =three 0a's<5
,2 (ress > 3 3 3 3 1 to delete all user ards2
-2 (ress > read ard 1 to delete the orres%ondin! ard
?2 (ress > in%ut ode 1 to delete lost ard2
@< Set o%en mode5
(ress ; 3 3 1 6' #alid ard onl'2
(ress ; 3 4 1 6' #alid ard and %ass0ord2
(ress ; 3 > 1 6' #alid ard or %ass0ord2
Note5 *ator' settin! is #alid ard2
Sine the initial %ass0ord an not 6e used to o%en door8 "* set to
#alid ard or %ass0ord mode8 %ass0ord *or use should 6e
modi*ied2
7<2 Set the len!th o* o%en time5
(ress @ A A 1 2
Note5 AA is *rom 33:BB8 unit is seond8 *ator' settin! is C
seonds2
C<2 Set the len!th o* alarm time5
(ress 7 A A 1 2
Note5 AA is *rom 33:BB8 unit is minute8 *ator' settin! is ;
minutes2
D< Set door state monitorin! mode5
(ress C 3 3 1 to disa6le this *untion2
(ress C 3 4 1 to ena6le this *untion2
Note5 to ena6le door state monitorin!8 reed s0ithes must 6e
installed8 0hen this *untion is ena6led8 the *ollo0in! t0o
*untions an also 6e ena6led at the same time5
,2 "* the user %ut in the orret %ass0ord to o%en the door8
then *or!et to lose the door8 the 6u..er 0ill !i#e
audi6le sound to note the user2
-2 "* the door is o%ened ille!all'8 the s'stem 0ill ati#ate
alarm si!nal out%ut8 at the same time8 6u..er emits sound
alarm2
E<2 Set sa*et' mode5
(ress D 3 3 1 to disa6le this *untion2
(ress D 3 4 1 to read 43 in#alid ards or #alid ards8
then enter @ 0ron! %ass0ords suessi#el'8 the s'stem is loFed *or
43 minutes2
(ress D 3 > 1 to read 43 in#alid ards or #alid ards8
then enter @ 0ron! %ass0ords suessi#el'8 the s'stem ati#ates
alarm si!nal out%ut2
Note5 *ator' settin! this *untion is disa6led2
: >ave the settin!s and e2it pro!rammin! mode(
Press / 2
Note5 / should 6e %ressed 0ithin 4 minute to sa#e the settin! 0hen
an' o* the a6o#e o%eration is om%leted2
7. &odify user password *no need in &rogramming mode+( after pressin! / to read
user ard8 the !reen LED *lashes8 in%ut user %ass0ord then %ress
1 to enter %ass0ord modi*'in! mode2 No0 in%ut ne0 %ass0ord o* @
*i!ures8 %ress 1 and in%ut the ne0 %ass0ord a!ain8 %ress 1 to
sa#e the settin!2
72 Go0 to use5
4<2 "n normal 0orF mode8 an 6e o%en 6' one #alid ard2
><2 Hhen #alid ard and %ass0ord mode8 an 6e o%en i* the orret
%ass0ord is %ut in 0ithin 43 seonds a*ter ard s0i%in!2
;<2 "* the %ass0ord o* a ard is *or!otten8 the in*ormation o* this
ard in the s'stem should 6e deleted *irst8 then add this ard to the
s'stem a!ain to modi*' the %ass0ord2
@<2 "* %ro!ram %ass0ord is *or!otten8 'ou an use Ium%er
s0ithJRESE9Kat the main 6oard to restore *ator' settin!2 First8
%o0er o**2 9hen set Ium%er s0ith toJ$NK%osition2 (o0er on2 Shi*t
the Ium%er s0ith 6aF to J$FFK%osition a*ter three 6ee%s o* the
6u..er8 no0 the *ator' settin! is restored2
Attachment" ,iring diagram for installation
%-$(" . Po,er off before installation ,iring. hot line ,or/ is forbidden00
#. %ormally. electroloc/ is connected out from &o,er controller.