You are on page 1of 13

STRUCTURAL ATTACHMENT ELEMENTS

PRODUCT
GROUP

STRUCTURAL ATTACHMENTS,
TRAPEZES
CONTENTS

PAGE

Structural attachments, trapezes ____________________________________ 7.1


Weld-on clevis type 73 ____________________________________________ 7.2

Weld-on eye plate type 75 ________________________________________ 7.2


Weld-on plate with spherical washer type 74 ________________________ 7.3
Beam clamp type 78

____________________________________________ 7.4

Trapeze type 79__________________________________________________ 7.4


Beam adapter type 76 ____________________________________________ 7.7

3
4
5
6
PRODUCT
GROUP

8
9
7.0

STRUCTURAL ATTACHMENTS, TRAPEZES


PRODUCT GROUP 7
The attachment of pipe
supports to the load bearing structure is produced
by means of special components to be welded or
clamped. The safety of the
connections depends on
their adaptation to the
prevailing situation and
their particular suitability
in each case.

Product Group 7
As well as trapezes, the components of
Product Group 7 include attachment elements
connecting directly to the structure, such as
trapezes.
The permissible loads correspond with the
load table for statically determined components on page 0.5 of the Technical
Specification.

Type 73

For weld-on clevis type 73 and weld-on eye


plate type 75, the minimum weld thicknesses
must be considered. These are designed in
such a way that the maximum weld stresses
do not exceed 10.9ksi [75N/mm2] during
normal operating conditions.
The stress analysis is based on a load
applied conically at under 6 angulation.

Type 74

The weld-on clevis type 73 is particularly


suited for attachment to hollow sections.
The beam clamp type 78 is designed for
unwelded on site attachment. The beam
width is to be specified when ordering.
Trapeze types 79 are suitable for use with
clamp base type 49 and can be used as
rigid hangers or in conjunction with variable
and constant hangers.

Type 75

For protection against corrosion, the components are coated with a weldable primer
(1.18mil [30m] ) or electrogalvanized and
then yellow chromatized (zinc thickness
0.59mil [15m] ). The trapeze sections are
coated to the LISEGA standard.
Material certification can be supplied for all
components on request.

Standardized connecting parts

7.1

Type 76

Type 78

WELD-ON CLEVIS TYPE 73


WELD-ON EYE PLATE TYPE 75

Weld on clevis
type 73 29 13 to 73 50 12
Material: carbon steel
Drop forged

From load group 20:


Flame cut design
Shape type 73 20 12 to 73 50 12

Type

A

d1

min.
Seam (leg length)

73 29 13
73 39 13
73 49 13
73 59 13
73 69 12
73 79 12
73 89 12
73 99 12
73 10 12
73 20 12
73 30 12
73 40 12
73 50 12

1 5/8
2
2 1/2
3
3 3/4
4 3/4
4 3/4
4 3/4
5 7/8
3
6 /4 x 67/8
63/4 x 67/8
57/8 x 71/2
71/8 x 85/8

0.48
0.63
0.79
0.95
1.30
1.58
1.78
1.97
2.37
2.76
2.76
3.15
3.55

13/8
15/8
2
23/8
31/2
43/8
43/4
51/8
51/2
57/8
57/8
63/4
75/8

7/
16
5/
8
3/
4
13/
16
11/16
11/4
17/16
15/8
115/16
25/16
25/16
23/16
21/2

23/8
23/4
31/2
41/8
47/8
51/2
61/2
71/4
81/4
95/8
95/8
9
91/2

13/8
13/4
21/4
25/8
31/8
35/8
43/8
43/4
57/8
61/2
61/2
57/8
61/2

1
11/4
13/4
21/8
21/2
31/8
31/2
37/8
43/4
63/4
63/4
57/8
71/8

3
3
31/2
43/8

3/
16
3/
16
3/
16
3/
16
1/
4
1/
4
5/
16
7/
16
1/
2
9/
16
5/
8
3/
4
13/
16

Weight
(lbs)
0.7
0.9
2.4
4.6
8.4
15.0
20.3
24.5
40.8
82.0
82.0
84.0
128.0

 Weld thickness is calculated


from the stress analysis and
based on a permissible stress of
10.9ksi [75N/mm2] at normal
load.

Order details:
Weld-on clevis type 73 .. 1.

Weld-on eye plate


type 75 D1 19 to 75 50 12
Material: carbon steel

Type

d3

75 D1 19
75 21 12
75 31 12
75 41 12
75 51 12
75 61 12
75 71 12
75 81 12
75 91 12
75 10 12
75 20 12
75 30 12
75 40 12
75 50 12

11/8
13/8
13/4
23/8
21/2
31/8
37/8
43/4
51/8
57/8
63/4
71/8
85/8
97/8

0.41
0.49
0.64
0.80
0.96
1.33
1.61
1.81
2.00
2.40
2.79
2.79
3.18
3.58

15/8
13/4
2
21/8
23/8
23/4
31/8
31/2
37/8
43/8
43/4
51/8
51/2
57/8

C
3/
7/

min. 
Seam (leg length.)

S
4
8

11/8
11/2
15/8
2
21/2
3
31/8
31/2
37/8
43/8
43/4
53/8

1/

5/

16
3/
8
1/
2
5/
8
3/
4

1
11/4
11/4
15/8
13/4
13/4
2
23/8

3/

16
1/
4

5/

16
3/
8
7/
16
1/

9/

16

5/
13/

16
7/
8
11/16
13/16
11/16
11/8

Weight
(lbs)
0.22
0.28
0.52
1.00
1.44
2.76
5.18
8.60
10.20
17.00
23.40
27.80
40.80
60.60

 Weld thickness is calculated


from the stress analysis and
based on a permissible stress of
10.9ksi [75N/mm2] at normal
load.

Order details:
Weld-on eye plate
type 75 .. 1.

7.2

SPHERICAL WASHER WITH


WELD-ON PLATE TYPE 74
Spherical washer with
weld-on plate
type 74 D1 19 to 74 50 13
Material:
carbon steel

Type

Order details:
Spher. washer with
weld-on plate
type 74 .. ..

7.3

74 D1 19
74 21 13
74 31 13
74 32 13
74 33 13
74 41 13
74 42 13
74 43 13
74 51 23
74 52 23
74 61 23
74 62 23
74 71 23
74 72 23
74 81 23
74 82 23
74 91 23
74 92 23
74 10 13
74 20 13
74 30 13
74 40 23
74 50 13

for
rod
3/ UNC
8
1/ UNC
2
5/ UNC
8
5/ UNC
8
5/ UNC
8
3/ UNC
4
3/ UNC
4
3/ UNC
4
1 UNC
1 UNC
11/4 UNC
11/4 UNC
11/2 UNC
11/2 UNC
13/4 UNC
13/4 UNC
2 UNC
2 UNC
21/4 UNC
21/2 UNC
23/4 UNC
3 UNC
31/4 UNC

A

B

23/8
23/4
23/4
33/4
51/8
23/4
33/4
51/8
33/4
51/8
51/8
63/4
51/8
63/4
51/8
63/4
51/8
63/4
87/8
97/8
97/8
113/4
133/4

1
11/8
11/8
11/8
13/8
13/8
13/8
13/4
13/4
21/4
21/4
25/8
25/8
31/8
31/8
35/8
35/8
4
43/4
5
53/8
6

7/
8

D
5/
8
3/
4

1
1
1
11/8
11/8
11/8
13/8
13/8
13/4
13/4
2
2
23/8
23/8
25/8
25/8
3
31/2
33/4
37/8
43/8

d4

max. F

13/
32
17/
32
21/
32
21/
32
21/
32
13/
16
13/
16
13/
16
11/32
11/32
19/32
19/32
117/32
117/32
125/32
125/32
21/32
21/32
29/32
219/32
225/32
31/32
39/32

7/
16
11/
16
11/
16
13/
16
13/
16
3/
4
7/
8
7/
8
15/
16
15/
16
17/16
17/16
11/2
11/2
15/

13/8
11/2
13/4
13/4
13/4
17/8
17/8
17/8
21/8
21/8
21/4
21/4
23/4
23/4
31/2
31/2
45/8
45/8
51/2
57/8
61/4
61/4
7

3/
8
3/
8
5/
8
5/
8
5/
8
3/
4
3/
4
3/
4
7/
8
7/
8
11/8
11/8
11/4
11/4
11/2
11/2
15/8
15/8

5/
8
5/
8
7/
8
7/
8
7/
8
11/8
11/8
11/8
11/4
11/4
15/8
15/8

3/
8
5/
8
5/
8
3/
4
3/
4
5/
8
3/
4
3/
4
3/
4
3/
4
11/4
11/4
11/4
11/4
11/4
11/4
13/8
11/4
13/8
15/8
13/4
13/4
13/4

15/8
113/16
111/16
17/8
23/16
23/8
23/8
21/2

2
23/8
21/2
23/4
31/8

2
2
21/4
21/4
25/8
25/8
31/8
35/8
37/8
41/4
43/4

Weight
(lbs)
0.6
1.4
1.4
3.0
6.0
1.4
3.0
6.0
3.0
6.0
8.8
15.0
8.8
15.0
8.8
15.0
10.0
15.0
30.6
43.2
48.6
70.2
95.4

BEAM CLAMP
TYPE 78

Beam clamp
type 78 21 11 to 78 71 11

Type

d3

78 21 11 0.65
78 31 11 0.81
78 41 11 1.00
78 51 11 1.34
78 61 11 1.60
78 71 112.00

A
31/8
31/8
47/8
47/8
71/8
71/8

E0 up to beam dim. b=
315/16 415/16 51/2 71/16 811/16 101/4 1113/16
21/2 21/2 21/2 3
33/8

23/4 23/4 23/4 31/8 31/2 37/8 43/8

33/8 31/2 31/2 37/8 41/8 41/2

33/4 33/4 41/8 41/2 51/8 51/2

37/8 37/8 43/8 43/8

41/2 41/2 47/8 51/8

113/16 31/4
21/8 21/8
23/4

tmax 

5/
16
3/
8
9/
16
9/
16
13/
16
13/
16

5/
8
13/
16

1
1
13/16
13/16

Weight
(lbs)
1.8 - 3.6
4.4 - 8.0
14.8 - 19.6
15.0 - 21.0
39.0 - 43.6
40.2 - 45.8

 Load groups 8 & 9 can be


connected. Permissible load
22480 lbs [100 kN] during normal
operating condition.
 A larger t dimension can be
accommodated by increasing Eo
accordingly. Indicate complete
beam size when ordering.

Order details:
Beam clamp
type 78 .1 11 beam size

TRAPEZE
TYPE 79
Trapezes for small loads and
pipe diameters  31/4 inch
type 79 C2 37 to 79 42 37

31/4

 The permissible center load is


limited by the load group of the
individual trapeze (3rd digit of type
number).

Type

Lmax

79 C2 37
79 D2 37
79 12 37
79 12 37
79 22 37
79 22 37
79 32 37
79 32 37
79 42 37
79 42 37

40
40
24
40
24
44
24
48
24
48

1
1
1
1
13/8
13/8
13/8
13/8
13/4
13/4

11/2
21/2
21/2
3
3
3
3
4
4
5

b
7/
8

1
1
11/8
11/8
11/4
11/4
13/8
11/2
15/8

d4
7/
16
7/
16
7/
16
7/
16
9/
16
9/
16
9/
16
9/
16
11/
16
11/
16

Weight (lbs) for L=


20inch
+/- per 1inch
0.20
4.3
0.34
7.9
0.34
7.9
0.41
9.8
0.41
9.8
0.60
14.4
0.60
14.4
0.82
20.6
0.82
20.6
1.35
36.1

Order details:
Trapeze
type 79 .2 37, L=...

7.4

TRAPEZE
TYPE 79
Trapeze
type 79 22 34 to 79 20 34

 The permissible center load is


limited by the load group of the
individual trapeze (3rd or 3rd and 4th
digit of type number).
 The L max dimension can be
extended to 941/2inch by reducing
the permissible load by 5% for
every 4inch of extension.
 The trapeze is dimensionally
compatible with other components
in the LISEGA modular system
within the load groups specified.

Order details:
Trapeze
type 79 .2 34, L=...

Load- 
group
D-4
D-4

d3

0.81
0.81

3/
8
3/
8

79 42 34

3-4

0.81

1/
2

79 52 34

4-5

1.00

3/
4

79 62 34

5-6

1.34

13/
16

79 72 34

6-7

1.60

79 82 34

6-8

1.80

79 92 34

7-9

2.00

11/4

79 10 34
79 20 34

8 - 10
9 - 10

2.40
2.40

11/4
11/4

Type
79 22 34
79 32 34

s


L max 

67
67
351/2
703/4
55
703/4
491/4
703/4
55
703/4
491/4
941/2
703/4
941/2
783/4
703/4

3/

3/

3/

15/8
15/8
15/8
15/8
21/8
23/8
21/2
23/4
31/8
33/8
31/2
33/4
33/4

4
4
4
6
6
6
6
8
8
8
8
10 1/4
10 1/4
12
12
12

51/2
51/2
51/2
71/2
71/2
81/8
81/8
91/2
91/2
97/8
97/8
13
13
133/4
133/4
14

Weight (lbs)
L=3feet +per 1inch
1.20
50
1.20
50
1.20
50
1.74
76
1.74
76
2.00
92
2.00
92
3.12
144
3.12
144
3.12
152
3.12
152
4.74
240
4.74
240
5.15
286
5.15
286
7.50
390

Trapeze
type 79 23 39 to 79 93 39
 The permissible center load is
limited by the load group of the
individual trapeze (3rd digit of
type number).
 The L max dimension 67 inch
& 703/4 inch of type 79 23 39 to
79 73 39 can be extended to
941/2inch by reducing the permissible load by 5% for every 4inch
of extension.
 The trapeze is dimensionally
compatible with other components in the LISEGA modular
system within the load groups
specified.

Order details:
Trapeze
type 79 .3 39, L=...

7.5

Type
79 23 39
79 33 39
79 43 39
79 53 39
79 63 39
79 73 39
79 83 39
79 93 39

Load- 
group
D- 4
D- 4
3- 5
4- 6
5- 7
6- 8
6- 9
7 - 10

d3
0.81
0.81
1.00
1.34
1.60
1.80
2.00
2.40

L max 
67
67
703/4
703/4
703/4
703/4
941/2
941/2

2
2
23/4
23/8
31/8
21/2
33/4
43/4

4
4
6
6
8
8
101/4
12

5 1/2
5 1/2
7 1/2
8 1/8
9 1/2
9 7/8
13
133/4

15/8
15/8
2
23/8
27/8
31/4
35/8
4

3/
8
3/
8
1/
2
3/
4
13/
16

1
1
11/4

Weight (lbs)
1 inch
L=3feet
50
1.20
50
1.20
80
1.74
96
2.00
152
3.12
154
3.12
258
4.74
316
5.16

7.6

BEAM ADAPTER
TYPE 76
For alterations or extensions to
pipe systems or structural steel
in existing plants, clamp connections are often preferred to welding for the necessary attachment
to the existing structure of pipe
supports or additional steel. The
use of this method is obligatory
when welding is ruled out for
safety reasons.
The long-lasting security of this
type of connection depends essentially on the condition of the contact
surfaces and the preset forces
applied. For a reliable connection,
the specific design of the clamp
elements used is decisive.

Offering the utmost reliability, LISEGA beam


adapters type 76 serve as secure connections
for this purpose.
These newly developed components enable
the attachment of diverse components to
existing steel without welding or drilling,
while installation is simple and time-saving.
LISEGA beam adapters adjust automatically
on tightening to the thickness of the component to be clamped. If the given torque
values are observed, the lasting security of
the connection is guaranteed. Existing corrosion protection, e.g. hot-dip galvanizing or
color coating, is not impaired.

Beam adapter
type 76 D2 11 to 76 42 11

Type
76 D2 11
76 22 11
76 32 11
76 42 11

Order details:
Beam adapter
type 76 .. 11

7.7

Bolts A193B7
support load
torque value
(lbs)
(lbs ft)

560
1350
1900
3370

25
50
110
220

17/8
21/4
23/4
33/8

13/16
11/2
17/8

 The tabulated loads are normal operating loads


(load condition H). For emergency (HZ) and faulted
loads (HS) see table Max. permissible loads
on page 0.5

15/
3
16 /8
1/
2
5/
8
3/
4

d2
UNC
UNC
UNC
UNC

min

11/4
11/2
13/4
21/8

max

11/2
13/4
21/8
25/8

t (clamp thickness) Weight


min
max
(lbs)
1/
5/
0.25
8
8
1/
11/
0.40
8
16
1/
13/
0.70
4
16
1/
1.30
1
4

Hex. Bolt, Grade 8.8,


inclusive Hex. Nut, Grade 8
Bolt-Type

Dimensions

Weight (lbs)

76 D2 11 - 065
76 D2 11 - 080
76 D2 11 - 100
76 22 11 - 070
76 22 11 - 090
76 22 11 - 120
76 32 11 - 090
76 32 11 - 120
76 32 11 - 150
76 42 11 - 120
76 42 11 - 150
76 42 11 - 180

M10 x 65
M10 x 80
M10 x100
M12 x 70
M12 x 90
M12 x120
M16 x 90
M16 x120
M16 x150
M20 x120
M20 x150
M20 x180

0.13
0.15
0.17
0.19
0.22
0.27
0.42
0.51
0.60
0.85
1.00
1.12

The unique feature of the LISEGA beam


adapters is represented by the special
contact elements. They adjust automatically
due to their shape to any position and any
existing sectional flange angles.

The hardened contact elements have a rounded grooved profile which presses into the
contact surface on tightening. This provides
a form-fit grip which offers mechanical security against shifting in any direction.
Cross connection:
The safe connection of beam sections to
each other is simple effected with an inlay
plate and eight LISEGA beam adapters. The
load capacity of a cross connection is given
in the table below.

Cross connection

Cross connection with LISEGA


beam adapters
Type
76 D2 11
76 22 11
76 32 11
76 42 11

Loading capacity (lbs)


with 4 bolts A193B7
2240
5400
7600
13480

Thickness of
intermed. plate
3/
8
1/
2
5/
8
3/
4

Interconnection of sections can be made directly or by


the use of a support plate. The load capacity of a
cross connection can be taken from the table on the
left.

7.8

GUIDE WITH BEAM ADAPTERS


FOR CLAMP BASES TYPE 49 .. .3/4/5
Guide with beam adapters
for clamp bases
type 76 00 11 up to
76 00 14
Material:
Guide: carbon steel

lift-off restraints

Order details:
Lateral guide
type 76 00 1.; b =
Order details:
Lateral guide with lift-off
restraint
type 76 00 2. - 49 .. ..
(Clamp base type); b =

type  with
lift-off restraint
76 00 11
76 00 21
76 00 12
76 00 22
76 00 13
76 00 23
76 00 14
76 00 24
Type

torque
value (lbs/ft)
25
50
110
220

Fx
(lbs)
225
380
630
1060

Fz 
(lbs)
790
1010
1460
1460

a1

a2

bmin

1 3/16
1 3/16
1 5/8
1 5/8

2
2 3/ 8
3 1/8
3 1/8

1 5/8
2
2 1/2
2 7/8

1 5/8
1 3/4
2 1/8
2 1/2

tmax

total weight (lbs)


for b=4inch +per inch

5/
8
11/
16
13/
16

0.34
0.53
0.78
0.78

3.7
6.2
10.8
15.9

 The guides can be supplied if required with an additional lift-off restraint (width: 31/8 inch [80mm])
(when ordering, give details in addition to designation of clamp base type).
Fz: the permissible short-term lift-off load is limited to 10% of the respective clamp base nominal load.

CANTILEVER WITH BEAM ADAPTERS


TYPE 76 .. 16
Cantilever with beam
adapters
type 76 C1 16 up to
76 21 16
Material:
Cantilever: carbon steel

Lmin = Zero
Order details:
Cantilever with beam
adapters
type 76 .1 16;
b=L=

7.9

Type
76 C1 16
76 D1 16
76 11 16
76 21 16

Lmax = b/2 + c

torque value
(lbs/ft)
25
50
110
220

axs
1 5/8
2 1/2
3
3 1/8

x
x
x
x

1/
4
1/
4
5/
16
3/
8

bmin

bmax

d4

tmax

1 5/8
2
2 3/16
2 1/2

11 3/4
11 3/4
11 3/4
11 3/4

1 5/8
1 3/4
2 1/8
2 1/2

7/
16
7/
16
9/
16
11/
16

1
1 3/4
1 7/8
2 1/8

5/
8
11/
16
13/
16

Weight (lbs)

Weight (lbs)

for b=4inch L=2inch

+per inch

2.0
3.8
6.4
9.8

0.20
0.34
0.51
0.60

CANTILEVER WITH BEAM ADAPTER


TYPE 76 .. 17

Cantilever with beam


adapter
type 76 C1 17 up to
76 21 17
Material:
Cantilever: carbon steel

L  b/2 + c
torque value a
(lbs/ft)
76 C1 17
25
1 5/8
76 D1 17
50
2 1/2
76 11 17
110
3
76 21 17 220
3 1/8
Type

x s bmin c d3 e

E tmax

x 1/4 113/16
x 1/4 2 3/16
x 5/16 2 1/2
x 3/8 2 7/8

3/ 5/
4
8
3/ 11/
4
16
1 13/16

15/8
13/4
21/8
21/2

7/
16
7/
16
9/
16
9/
16

7/
8

1
11/8
11/8 1 1

31/4
43/4
41/8
43/8
53/4

Lmax up to beam dim. b=


4 5 51/2 71/8 85/8 101/4
9 105/8 121/4 125/8 133/8 141/8
63/4 77/8 97/8 11 133/8 141/8
51/2 63/4 77/8 9 113/8 133/4
61/4 71/2 91/4 103/8 113/8 121/4

Weight (lbs)
for b=4 inch
113/4 L=4 inch

+per
inch

15
15
15
13

0.20
0.34
0.51
0.60

2.3
4.2
6.8
10.1

Order details:
Cantilever with beam
adapter
type 76 .1 17;
b=L=

APPLICATION EXAMPLES
LISEGA beam adapters can be used in combination with all components suitable for
seating or flanging on beams. Here are two
further typical examples with LISEGA standard components:
Clamp base as fixed point

Roller bearing with side plates fitted at works

7.10