You are on page 1of 2

t (s)

V (m3)

Cumulative Volume, V
(m3)

t/V
(s/m3)

15
30
45
60
75
90
105
120
135
150
165
180
195
210
225
240
255

0.00145
0.001365
0.00136
0.00135
0.00125
0.00125
0.00114
0.00112
0.001008
0.0008
0.00076
0.00045
0.00023
0.00012
0.000084
0.00007
0.000074

0.00145
0.002815
0.004175
0.005525
0.006775
0.008025
0.009165
0.010285
0.011293
0.012093
0.012853
0.013303
0.013533
0.013653
0.013737
0.013807
0.013881

10344.83
10657.19
10778.44
10859.73
11070.11
11214.95
11456.63
11667.48
11954.31
12403.87
12837.47
13530.78
14409.22
15381.23
16379.12
17382.49
18370.43

The values are


omitted.
The highlighted
part is considered
as constant value
which is
insignificant
values. When
statistical analysis is
carried out, which
p>0.05 is obtained.

Table 1: Result of time, volume of filtrate and pressure for plane press filter.

t/V vs. V
20000
18000
16000

y = 448597x + 8021.6
R = 0.6041

t/V (s/m3)

14000
12000
10000

t/V (s/m3)

8000

Linear (t/V (s/m3))

6000
4000
2000
0
0

0.005

0.01
V (m3)

Graph 1: The result for t/v vs. V.

0.015

t (s)
15
30
45
60
75
90
105
120
135

V (m3)
0.00145
0.001365
0.00136
0.00135
0.00125
0.00125
0.00114
0.00112
0.001008

cumulative volume, V (m3)


0.00145
0.002815
0.004175
0.005525
0.006775
0.008025
0.009165
0.010285
0.011293

t/V (s/m3)
10344.83
10657.19
10778.44
10859.73
11070.11
11214.95
11456.63
11667.48
11954.31

Table 2: Result of time, volume of filtrate and pressure for plate press filter after omitting
the insignificant data.

t/V (s/m3)
12200
12000

y = 149529x + 10123
R = 0.9719

11800
t/V (s/m3)

11600
11400
11200

t/V (s/m3)

11000

Linear (t/V (s/m3))

10800
10600
10400
10200
0

0.002

0.004

0.006

0.008

0.01

0.012

V (m3)

Graph 1: The result for t/v vs. V after omitting the insignificant data.