Building Technologies A wide range of applications. BC80 comprises an extensive product portfolio and can be installed in various building types. For instance, it is a perfect solution for: Hotels Commercial buildings Residential complexes Government buildings Retail stores 2 3 High quality based on decades of experience, in-depth research, and state-of-the-art production technology from Siemens A flexible solution expandable and compatible with future developments Cost-effective moderate investment and easy adaptation to changing requirements BC80 advantages at a glance: Siemens quality high reliability With the BC80 system, you can offer your customers Siemens quality, based on in-depth research and de- velopment, state-of-the-art produc- tion technology and over 150 years of experience in fire protection. The products meet all technical safety requirements, from short-circuit pro- tection to immunity against electro- magnetic interference. BC80 offers the flexibility your cus- tomers need, whether they want to expand or modernize their system. Thanks to its open topology, the sys- tem is forward-looking for easy adaptation to growth and changing requirements. Siemens technology high cost-effectiveness BC80 combines high-quality tech- nology with cost-effectiveness, in procurement as well as operation. Moderate hardware costs keep the investment manageable, while the flexible, expandable installation pro- tects the long-term view genuine brand quality at an economical price, for years to come. High-quality Siemens products reliable and economical. Your customers are responsible for the protec- tion of their employees, buildings, and assets. They also experience cost competition. As a result, they need fire protection components that deliver reliable fire detection and alarm signaling, but which are also cost-efficient. Fire safety products from Siemens position you per- fectly to satisfy your customers requirements. The BC80 system products range from fire detec- tors to control panels. They are moderately priced and of reliable quality. 4 Easy installation fast protection Because the BC80 system units have been designed for easy installation, buildings can be protected quickly. BC80 provides polarity-free wiring; poles can no longer be accidentally reversed. Therefore, the networking of BC80 fire detectors, peripheral equipment, and BC80 control panels is rapid and accurate. The use of spur lines and T-Branches (F-Bus) further simplifies installation. Easy configuration fast commissioning Commissioning of the BC80 system is supported by an integrated auto- configuration function; with it, the system automatically detects all inte- grated devices (auto-mapping). This reduces manual configuration to a minimum eliminating a potential source of error. You benefit from a shorter time to a fully-operational system. More complex manual programming can be conducted via the control panels or by using Windows-based software. Easy concepts make your work easier. BC80 fire protection products are easy to imple- ment and service. They can be quickly installed and rapidly commissioned. This reduces your costs and speeds up order processing. Simplicity of design reduces the period needed to gain familiarity with the system, so you can offer your customers user-friendly fire protection in the shortest possible time. Easy maintenance no interruption of operation All devices displayed on the con- trollers are shown with both their address number and position details. These help your customers assess error messages as aids to decision- making, and you to keep a clear overview during installation and maintenance. Devices with conven- tional technology, such as collective fire detectors, can also be wired to the BC80 system via spur lines. Tracing faulty fire detectors or periph- eral devices during system operation is swift, targeted, and cost-efficient. 5 Easy installation and fast building protection thanks to installation aids and polarity-free non-shielded cabling Fast commissioning thanks to auto-mapping and Windows-based software Minimal maintenance with address and position of all detectors and peripheral devices needing service directly indicated Smooth expansion via card inserts for control panels and T-Branches for cabling Easy modernization through use of present cabling, compatibility with existing peripheral equipment, and simple software uploads BC80 advantages at a glance: Easy expandability high flexibility BC80 grows with your customers requirements. When buildings or rooms are extended, the BC80 in- stallation can also be expanded, for example with new T-Branches in the cabling and expansion cards in the control panels. With an expansion card it is possible to hook up an additional 127 periph- eral devices via the F-Bus, as many as 32 additional control panels via the A-Bus, and up to three B-Bus devices, such as extinguishing control panels or interlocking panels. This increases options for larger projects. Easy conversion fast modernization Existing systems can be replaced and modernized with BC80 without large cabling expenditures. Currently in- stalled cables can be used to network BC80 devices, since neither the fire detector lines nor the notification appliance circuits require a shielded wire. The system can also be linked with existing peripheral devices, which saves time and money. Soft- ware updates can be uploaded via the USB port of the control panels. 6 BC80 design and installation guidelines. In this section, we illustrate best practice for installation of fire detection equipment. While not all possible cases may be covered, these are intended to provide guidelines. Local regulations may be more detailed and must always be ob- served. Please contact your local Siemens sales organization for more detailed information and documentation. BC80 detectors detectors should be positioned* at least 0.5 m from the wall max. 12 m from the previous detector BC80 manual call points manual call points should be positioned* in a clearly visible location 1.5 m from floor level BC80 fire control panels mounting the fire control panel* Keep a minimum distance to objects which could obscure the panel or the view to it 7 * or observe local regulations Detector positioning near elevators* Detector positioning near fresh air supply* Use a support to install a detector at ceiling height* 8 BC80 design and installation guidelines. * or observe local regulations Place the detector at the highest point in the room* Ensure the correct distance to ceiling obstacles* Position the detector within the top 10% of a space* Ensure a minimum distance to objects which could ob- struct the view to a manual call point* Manual call points should not be obscured by an open door* 9 Planning aid for fieldbus. BDS031 BDS051 BDS121 BDS132 BDS221 BDS152 BDS161 BDS331 Load Max. current (mA) Quiescent current (mA) Name Address points 0.71 0.71 0.43 0.6 0.61 0.07 4 10 0.89 0.89 2.86 3.8 2.19 0.5 16 90 1 1 1 1 2 0 10 1 Heat detector Photoelectric smoke detector Manual call point Input module Output module Isolate module Collective input module Fire alarm display panel BC8001 BC8001E BC8001P BC8001PE BC8002-1 BC8002-2 BC8002-3 Source Max. current (mA) Quiescent current (mA) Name Address points 48.5 63.3 51.2 66.0 130.0 170.0 210.0 75.7 113.7 97.0 135.6 224.8 352.6 481.4 127 254 127 254 500 1,000 1,500 Compact controller with 1 line Compact controller with 2 lines Compact controller with 1 line, printer Compact controller with 2 lines, printer Wall-mounted (500 dev.) Wall-mounted (1,000 dev.) Wall-mounted (1,500 dev.) Detectors and peripherals Panels and systems A-Bus Compact Heat detector BDS031 Photoelectric smoke detector BDS051 Manual call point BDS121/e Output module BDS221 Manual call point BDS121/e Input module BDS132 Collective input module BDS161 Compact controller BC8001 F-Bus Interlocking panel BT8012 Interlocking panel BT8011 Compact controller BC8001 Collective heat detector HI520 10 BC80 at a glance. B-Bus Extinguishing panel BC8013 Standard control panel BC8002 Standard F-Bus Collective photoelectric smoke detector OP520 Standard control panel BC8002 11 Legend A-Bus Network for connecting control panels (max. 32 control panels, bus length 1 km can be extended with CAN-Bus bridge) F-Bus Bus system for connecting line devices (max. 127 devices per line, bus length 1 km) B-Bus Network for connecting up to 3 B-Bus devices (bus length 100 m) Building Technologies BC80 Innovative fire safety products from Siemens. Are you seeking reliable and easy to use fire safety products everywhere? With the addressable BC80, Siemens offers an extensive and economical portfolio from fire detectors to control panels. Thanks to its open topology, BC80 is highly flexible and adapts easily to changing requirements. The perfect solution for a wide range of applications from small to large buildings, it can be quickly installed, networked, and put into service. Backed by 150 years of experience in fire protection, BC80 offers the effective protection you want for people, buildings and assets. For more information, please visit www.siemens.com/buildingtechnologies. Genuine quality for your protection. Table of Contents 1 Siemens Building Technologies Group Panels & Systems ................................................................................................................. 1-1 Addressable Control Panels .............................................................................................. 1-1 Detectors & Peripherals........................................................................................................ 2-5 Conventional Detectors and Bases (Collective).................................................................. 2-5 Addressable Detectors and Bases...................................................................................... 2-6 Manual Call Points ........................................................................................................... 2-7 Addressable Modules ....................................................................................................... 2-8 Spare Parts & Upgrades...................................................................................................... 3-10 Panels & Systems Addressable Control Panels 1-1 Siemens Building Technologies Group 1 Type Order No. BC8001.. BC8001 Compact Control Unit BC8001 is a control unit suitable for small sized projects and construc- tions. It has the following features: l Compatible to BDS series of field devices. l Features a polarity free F-BUS with a twisted pair of wires ( 1.5mm2). Transmission distance is up to 1000m. All devices should be evenly distributed. l Specialized BDS Algorithm enhance immunity against environment disturbances. l Menu driven man-machine interface to allow very easy operation. l With optional extension card the device can be networked with up to 32 other BC80 control units (BC8001/BC8002). l With optional extension card it is possible to connect up to 3 B-Bus devices i.e. interlocking and extinguishing panels. l An optional printer can be mounted into the control unit. l The system can be easily configured directly on the panel or via PC. l Configuration data can be uploaded to a PC at any time. Number of detector lines 1 Number of field devices 127 System Network - Built-in printer - LCD Display 240 x 128 Backlit Auto Mapping Yes Event memory 1000 Digital inputs/outputs 1 Dry contact (24 VDC / 3 A) 1 OC output 2 Monitored inputs Operating voltage (Main Power) 187... 242 VAC 50... 60 Hz Battery capacity 24 VDC 7 Ah Download/Upload USB Dimensions (W x H x D) 370 x 265 x 120 mm Weight (without battery) 3.0 kg Data sheet A5Q00016399A BC8001.. BC8001 BC8001 Compact Control Unit with 1 F-Bus line for up to 127 Devices Technical details as BC8001.. A6C50000016 BC8001P BC8001P Compact Control Unit with 1F-Bus line and printer As BC8001.. for technical details but with the following differences: One printer TP8000 (thermal sensitive printer) is built-in. A6C50000018 Panels & Systems Addressable Control Panels 1-2 Siemens Building Technologies Group Type Order No. BC8001E BC8001E Compact Control Unit with 2 F-Bus lines for up to 254 Devices As BC8001.. for technical details but with the following differences: An extension card is built-in additionally in the BC8001. This allows l Interconnection of up to 32 BC8001 or BC8002 control units (A-Bus). l Interconnection of up to 3 B-BUS equipments (BT8011/12 interlock- ing panel BC8013 extinguishing panel). Another external power supply (3 A @ 28 VDC) must be used. A6C50000017 BC8001PE BC8001PE Compact Control Unit with 2 F-Bus lines and printer As BC8001.. for technical details but with the following differences: Printer and extension card are built-in additionally. A6C50000019 BC8002.. BC8002-1/e wall-mounted Advanced Control Unit BC8002 is an advanced control unit based on latest technology to sup- port easy operation and commissioning. l Text and graphic Display with 10 LCD,640x320 dots backlit. l Easy operation with a menu structure similar to Windows Explorer. l Advanced micro-processor system (32-bit ARM based micro-proces- sor). l LCD display shows real time values of fire parameters for every detec- tion point. l Auto mapping of the controller configuration simplifies commission- ing. l Multi-tasking real time operating system monitors the system regu- larly. This ensures high system reliability. l Up to 1000 events are stored in the event memory. l Modular structure allows flexible system customization. l System configurations can be done via panel keypads or via PC tool (parameters and logic expressions). l Powerful interlocking features can be added for demanding control functions. l Up to 32 control units can be interconnected via A-Bus network. Transmission distance is up to 1000m with a twisted pair of wires ( 1.5mm2). l BC8002 can be connected to a management station. Mains voltage 220 VAC 50 Hz Operating voltage 23... 30 VDC Battery capacity 24 VDC 17 Ah Quiescent current 40... 100 W Fuse 2.0 A Operating temperature -10... +50 C Relative humidity 95% (40 2 C) Dimensions (W x H x D) 700 x 520 x 120 mm Weight 22 kg Data sheet A5Q00016408A BC8002.. BC8002-1 BC8002-1/e wall-mounted Advanced Control Unit for up to 500 devices 4 loops As BC8002.. for technical details but with the following differences: The fire alarm control unit with the original 1 line card can connect up to 500 devices. A6C50000029 Panels & Systems Addressable Control Panels 1-3 Siemens Building Technologies Group 1 Type Order No. BC8002-2 BC8002-2 wall-mounted Advanced Control Unit for up to 1000 devices As BC8002.. for technical details but with the following differences: The fire alarm control unit with an additional line card can connect up to 1000 devices using 8 loops A6C50000030 BC8002-3 BC8002-3 wall-mounted Advanced Control Unit forv1500 devices As BC8002.. for technical details but with the following differences: The fire alarm control unit with 3 line cards can connect up to 1500 devices using 12 loops A6C50000030 BT80.. BT8011 / BT8012 Interlocking Panel BT8011 / BT8012 are interlocking panels. It allows manual and auto- matic control of external equipment. It is usually installed in the fire control center together with fire alarm panels in order to control pumps fans etc. Operating voltage 24... 29 VDC Quiescent current 50 mA Operating temperature 0... +50 C Storage temperature -20... +60 C Relative humidity 95 % Rh Load for each output 300 4 K Installation height 3 U Data sheet A5Q00016409A BT80.. BT8011 BT8011 Interlocking Panel As BT80.. for technical details but with the following differences: l equipped with 16 inputs and 8 outputs. l Inputs: 8 inputs are for general purpose and 8 inputs are for confir- mations. l Outputs: OC output capacity is 28 VDC / 80 mA. l Output can be configured as steady on or pulsed. l Device is connected with the control unit via B-Bus. l Indication of activation confirmation and fault for each output . l Silence and lamp test keypad available. l Panel can be set to manual mode or automatic mode. l Panel address output mode connection mode are set with DIP- switch. l TP8000 printer is built-in. A6C50000032 BT8012 BT8012 Interlocking Panel (without printer) As BT80.. for technical details but with the following differences: l Equipped with 16 outputs and 24 inputs. l Inputs: 8 inputs are for general purpose 16 inputs are for confirma- tion l Outputs: each OC output capacity is 28 VDC / 80 mA. l Output can be configured as steady on or pulsed. l Device is connected with the control unit via B-Bus. l Indication of activation confirmation and fault for each output. l Silence and lamp test keypad available. l Panel can be set to manual mode or automatic mode. l Panel address output mode connection mode are set with DIP- switch. A6C50000033 Panels & Systems Addressable Control Panels 1-4 Siemens Building Technologies Group Type Order No. BC8013.. BC8013 Extinguishing Panel The extinguishing panel is used for the control of the extinguishing sections of a fire installation. l One panel monitors 2 extinguishing sections. l Each section is equipped with 3 outputs to activate extinguishing alert extinguishing section separation and gas release. 3 inputs serve as confirmation of above control outputs. l The device is connected via B-Bus. The address is set with a DIP- switch. l Important information of the extinguishing section are displayed on the control unit. l Parameters can be configured on the panel directly or via PC-Tool. l External control wires are monitored for short or open circuit. l Panel can be set to automatic mode and manual mode. l Panel supports auto mapping feature . Operating voltage 24... 28 VDC Quiescent current 40 mA Operating current 200 m A Output current 80 m A Maximum current per output 200 m A Operating temperature -20... +40 C Data sheet A5Q00016401A BC8013.. BC8013 BC8013 Extinguishing Panel Same technical details as BC8013.. A6C50000038 BC8013H BC8013H wall-mounted Extinguishing Panel As BC8013.. for technical details but with the following differences: Wall-mounted Extinguishing Panel A6C50000022 Detectors & Peripherals Conventional Detectors and Bases (Collective) 2-5 Siemens Building Technologies Group 2 Type Order No. HI520 HI520 Collective Heat Detector (Rate of Rise and Fix Temperature) l Newly developed circuit and sensor ensure high performance of fixed and rate of rise temperature detection. l High stability against dust electromagnetic interference tempera- ture fluctuation humidity and corrosion. l Produced with SMT advanced technology. Operating voltage 16... 32 VDC Output voltage 5... 13 VDC Operating temperature -10... +50 C Storage temperature -30... +75 C Relative humidity 95 % (40 2 C) Quiescent current 100 A Alarm current 1.5 mA EMC 10 V/m Data sheet A5Q00016379A A6C50000009 OP520 OP520 Collective Optical Smoke Detector The OP520 is an non addressable detector which can be connected in to S11 and BC80 system via corresponding collective input modules. l Patented optical structure and labyrinth. l Homogeneous sensitivity for different kind of smoke. l High stability against dust electromagnetic interference tempera- ture fluctuation humidity and corrosion. l Produced with advanced SMT technology. l Connection is independent of line polarity. Operating voltage 21... 29 VDC Output voltage 5... 13 VDC Operating temperature -10... +50 C Storage temperature -30... +75 C Relative humidity 95 % (40 2 C) Quiescent current 100 A Alarm current 1.5 mA EMC 10 V/m Data sheet A5Q00016380A A6C50000010 SO520 SO520 Collective Detector Base The detector base for field devices HI520 and OP520. Data sheet A5Q00016382A A6C50000011 Detectors & Peripherals Addressable Detectors and Bases 2-6 Siemens Building Technologies Group Type Order No. BDS031 BDS031 Addressable Heat Detector (Rate of Rise and Fix Tempera- ture) BDS031 is a heat detectors which can be connected to the F-Bus l Newly developed circuit and sensor ensure high performance of fixed and rate of rise temperature detection. l High stability against dust electromagnetic interference tempera- ture fluctuation humidity and corrosion. l Produced with SMT advanced technology. Operating voltage 16... 32 VDC Operating temperature -10... +50 C Storage temperature -30... +75 C Relative humidity 95 % (40 2 C) Quiescent current 1.0 mA Alarm current 3.0 mA EMC 10 V/m Data sheet A5Q00016383A A6C50000001 BDS051 BDS051 Addressable Optical Smoke Detector BDS051 is smoke detector which can be connected to the F-Bus. l Patented labyrinth optical structure. l New built-in ASIC ensures high reliability of data processing. l Homogeneous response to different kind of smoke. l High stability against dust electromagnetic interference tempera- ture fluctuation humidity and corrosion. l Produced with SMT advanced technology. Operating voltage 16... 32 VDC Operating temperature -10... +50 C Storage temperature -30... +75 C Relative humidity 95 % (40 2 C) Quiescent current 1.0 mA Alarm current 3.0 mA EMC 10 V/m Data sheet A5Q00016384A A6C50000002 BDS000 BDS000 Addressable Detector Base Detector base is for field devices BDS051 and BDS031. The detector covers the whole base the wiring capacity is 1.0 to 1.5 mm. Data sheet A5Q00016385A A6C50000000 Detectors & Peripherals Manual Call Points 2-7 Siemens Building Technologies Group 2 Type Order No. BDS121 BDS121 Manual Call Point Manual call point can immediate trigger a fire alarm by breaking the glass. l Connected to F-Bus l Installed in the public area such as staircase elevator lobby etc l Device address can be set via a DIP-switch. l A built-in dry contact can be used to activate another equipment. l Mounted on the wall 1.5 meters above the ground. l Electronic part and housing are delivered separately. Operating voltage 24 VDC Operating temperature -20... +55 C Relative humidity 95 % (40 2 C) Quiescent current 1 mA Alarm current 3.0 mA Capacity of dry contact 24 VDC / 0.1 A EMC 10 V/m Data sheet A5Q00016386A A6C50000003 Detectors & Peripherals Addressable Modules 2-8 Siemens Building Technologies Group Type Order No. BDS132 BDS132 Input Module The input module serves as an interface to transmit alarms or technical signals from other equipments to the fire alarm control unit. l Connected to the F-Bus device address can be set with a DIP-switch. l Serves as interface for potential free signals from flow switches pres- sure switches etc to the fire alarm system. l The signal will be transmitted to the controller and trigger corre- sponding actions. l Connection faults will be automatically detected and displayed on the controller. Operating voltage 24 VDC Operating temperature -20... +55 C Relative humidity 95 % (40 2 C) Activation current 3 m A Quiescent current 1 mA Wiring Capacity 1.0 1.5 mm Data sheet A5Q00016394A A6C50000004 BDS152 BDS152 Isolation Module The isolation module is used to isolate a short circuit on the detection bus. The device will automatically recover to its normal status when the cause of the short circuit disapears. l The isolation module separates a short circuit on the F-Bus. l Parallel connection on the first place of each branch or stub is possi- ble. l No device address is required. l When a single loop is used to connect devices mounted on several floors it is recommended to install one isolation module on each floor. l Up to 25 field devices can be mounted to an isolation module. l The connection is polarity free. l Faults will be automatically detected and displayed on the controller. Operating temperature -20... +50 C Relative humidity 95 % (40 2 C) Activation current 0.5 mA Pass through voltage 1 VDC Wiring Capacity 1.0... 1.5 mm Data sheet A5Q00016395A A6C50000005 Detectors & Peripherals Addressable Modules 2-9 Siemens Building Technologies Group 2 Type Order No. BDS161 BDS161 Collective Input Module Collective input module can connect collective detectors to the F-Bus l Directly connected to the F-Bus addresses are set with a DIP-switch l Up to 15 collective detectors can be connected to the module l An end of line element P6KE18CA has to be used. l Module transmits alarm fault and danger level signal to the control unit l The same indications are displayed on the module. l Connection is polarity free. l Faults will be automatically detected and displayed on the control unit. Alarm voltage 3.7... 16.4 VDC Fault voltage 0... 3.7 VDC (short) 22.1 VDC (open) Normal voltage 16.4... 22.1 VDC Alarm current <16 mA Operating temperature -10... +50 C Quiescent current <4 mA Relative humidity 95 % (40 2 C) Wiring Capacity 1.0... 1.5 mm Data sheet A5Q00016397A A6C50000006 BDS221 BDS221 Output Module The output module is used to activate external equipment according to the function of the fire alarm unit. l Connected to F-Bus addresses are set with a DIP-switch. l Output can be configured as pulse or steady on with DIP-switch. l Connection is polarity free. l The input signal for feedback is a potential free contact. l It is not recommended to use this module for extinguishing control directly. l Faults will be automatically detected and displayed on the controller. Operating voltage 24 VDC Operating temperature -10... +50 C Relative humidity 95 % (40 2 C) Activation current 3 mA Quiescent current 1 mA Relay output 125 VAC / 0.6 A 24 VDC / 2 A Status LEDs Steady output - Steady ON Pulse Output - Flashing Wiring Capacity 1.0... 1.5 mm Data sheet A5Q00016398A A6C50000007 Spare Parts & Upgrades 3-10 Siemens Building Technologies Group Type Order No. TP8000 TP8000 Printer A thermal sensitive printer is used to print events. Data sheet A5Q00016403A A6C50000028 BCE8001 BCE8001 Extension Card Extension card for BC8001 compact controller. This card contains the following interfaces: l A-Bus interface to add the network feature to the compact controller (networkable up to 32 controllers). l B-Bus interface to allow BC8001 to connect up to 3 B-Bus devices. l F-Bus interface for additional up to 127 devices. Data sheet A5Q00016402A A6C50000024 BCC8001 BCC 8001 Main Board of BC80 Compact Data sheet A5Q00016405A A6C50000035 BT8002 BT8002 Operation Panel The BT8002 is the operation panel of BC8002 Advanced Control Unit. l The operation panel consists of the main board BCC8002 the CPU board BCC8011 LCD and the keypads and LED's as indicators. l Connected with other control units via A-Bus. l Connected with interlocking panels line cards extinguishing panels via B-Bus. l Download/Upload port on the CPU board. l BT8002 Operation panel features also numerical keys and loud speaker. l A communication port for connection to a management station is built-in. Data sheet A5Q00016413A A6C50000034 Spare Parts & Upgrades 3-11 Siemens Building Technologies Group 3 Type Order No. BCB8001 BCB8001 Wall-mounted Power Supply (8A) Input voltage 220 VAC / 50HZ 187... 242 VAC (Effective) Output voltage 20... 28 VDC / 8 A (Main power ork- ing) 24 VDC (Only battery working) Operating temperature -10... 50 C Relative humidity 95 % Rh Protection Output 8.0 * 110 % (Over current protection) Output 1.0 (Output short pro- tection) Voltage <20.0 V (Battery low pro- tection) Battery CB12170 (12 V / 17 AH) CB12250 (12 V / 25 AH) CB12380 (12 V / 38 AH) DJW (12 V / 24 AH) DJW (12 V / 38 AH) NP (12 V / 24 AH) NP (12 V / 38 AH) Data sheet A5Q00016411A A6C50000039 BCC8002 BCC8002 Main Board of BC8002 Advanced Control Unit The main board includes l A-Bus port l B-Bus port l I/O port l FMS connection port l power signal port etc. The board handles data gathered from F-Bus and other channels. It serves as the data processing center of the control unit. Data sheet A5Q00016407A A6C50000036 Spare Parts & Upgrades 3-12 Siemens Building Technologies Group Type Order No. BCM8001 BCM8001 Line Card for BC8002 Advanced Control Unit The BCM8001 is the line card connecting BDS field devices l Each BCM8001 can connect 4 loops; each loop can connect up to 127 devices. l Overload protection: recovers to normal status when the cause of overload disappears. l B-Bus address is set with a DIP-switch on the board. Number of loops 4 Number of addresses 127 (on one loop) Max. load factor 150 (for each loop) Wiring Capacity RVS1.0... RVS1.5 Max. distance per line 1000 m Resistor per line 300 Capacitor per line 300 nF Protection Short protection Over voltage protection Connectable field devices BDS Series Operating voltage Modulated 16... 32 VDC Quiescent current Full load: 200 mA No Load: 110 mA Data sheet A5Q00016410A A6C50000037 Type Index 1 Siemens Building Technologies Group Type Description Order No. Page BC8001 BC8001 Compact Control Unit with 1 F-Bus line for up to 127 Devices A6C50000016 1-1 BC8001.. BC8001 Compact Control Unit BC8001.. 1-1 BC8001E BC8001E Compact Control Unit with 2 F-Bus lines for up to 254 Devices A6C50000017 1-2 BC8001P BC8001P Compact Control Unit with 1F-Bus line and printer A6C50000018 1-1 BC8001PE BC8001PE Compact Control Unit with 2 F-Bus lines and printer A6C50000019 1-2 BC8002-1 BC8002-1/e wall-mounted Advanced Control Unit for up to 500 devices 4 loops A6C50000029 1-2 BC8002-2 BC8002-2 wall-mounted Advanced Control Unit for up to 1000 devices A6C50000030 1-3 BC8002-3 BC8002-3 wall-mounted Advanced Control Unit forv1500 devices A6C50000031 1-3 BC8002.. BC8002-1/e wall-mounted Advanced Control Unit BC8002.. 1-2 BC8013 BC8013 Extinguishing Panel A6C50000038 1-4 BC8013.. BC8013 Extinguishing Panel BC8013.. 1-4 BC8013H BC8013H wall-mounted Extinguishing Panel A6C50000022 1-4 BCB8001 BCB8001 Wall-mounted Power Supply (8A) A6C50000039 3-11 BCC8001 BCC 8001 Main Board of BC80 Compact A6C50000035 3-10 BCC8002 BCC8002 Main Board of BC8002 Advanced Control Unit A6C50000036 3-11 BCE8001 BCE8001 Extension Card A6C50000024 3-10 BCM8001 BCM8001 Line Card for BC8002 Advanced Control Unit A6C50000037 3-12 BDS000 BDS000 Addressable Detector Base A6C50000000 2-6 BDS031 BDS031 Addressable Heat Detector (Rate of Rise and Fix Temper- ature) A6C50000001 2-6 BDS051 BDS051 Addressable Optical Smoke Detector A6C50000002 2-6 BDS121 BDS121 Manual Call Point A6C50000003 2-7 BDS132 BDS132 Input Module A6C50000004 2-8 BDS152 BDS152 Isolation Module A6C50000005 2-8 BDS161 BDS161 Collective Input Module A6C50000006 2-9 BDS221 BDS221 Output Module A6C50000007 2-9 BT80.. BT8011 / BT8012 Interlocking Panel BT80.. 1-3 BT8002 BT8002 Operation Panel A6C50000034 3-10 BT8011 BT8011 Interlocking Panel A6C50000032 1-3 BT8012 BT8012 Interlocking Panel (without printer) A6C50000033 1-3 HI520 HI520 Collective Heat Detector (Rate of Rise and Fix Temperature) A6C50000009 2-5 OP520 OP520 Collective Optical Smoke Detector A6C50000010 2-5 SO520 SO520 Collective Detector Base A6C50000011 2-5 TP8000 TP8000 Printer A6C50000028 3-10 12 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel +41 41 724 24 24 Fax +41 41 724 35 22 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Windows is a registered trademark of Microsoft Corporation Subject to change Order no. 0-92065-en Siemens Switzerland Ltd Printed in Switzerland 10705 Ah