Professional Documents
Culture Documents
Double Pipe Heat Exchanger Calculations
Double Pipe Heat Exchanger Calculations
Outer pipe
Inner pipe
Outer pipe
Inner pipe
Outer pipe
Fluids
Water
Hexane
Dimensionless variables
mu
Re
Pr
Nu (D/k)
0.753284 55695.38 1.953102 0.658935
0.586891 17295.77 5.101434 0.674359
lb/fthr
1
Fluids
Water
Hexane
Tw
363.7056
319.2611
K
muw
mu/muw Nu
h
0.753284
1 180.0078 273.1801
0.586891
1 97.26962 144.2401
lb/fthr
Btu/hrft2F
1/Ud
0.040621
0.040621
hrftF/Btu
Tw
348.0401
345.2683
K
muw
mu/muw Nu
0.920915 0.817973 175.0148
0.477809 1.228295 100.1105
lb/fthr
1/Ud
0.040355
0.040355
hrftF/Btu
Tw
347.487
344.6968
K
muw
mu/muw Nu
h
1/Ud
0.927972 0.811753 174.8279 265.319 0.040384
0.479833 1.223115 100.0513 148.365 0.040384
lb/fthr
Btu/hrft2F hrftF/Btu
2
Fluids
Water
Hexane
Iteration
Inner pipe
Outer pipe
Constant properties
Fluid properties
v
mu
2736.109 0.000311
5839.314 0.000243
ft/hr
kg/ms
Fluids
Water
Hexane
Iteration
Inner pipe
Outer pipe
Converted quantities
Fluid properties
Temperatures
w
Cp
k
rho
Tin
Tout
8424.453
1.006
0.388
59.975 372.0389 355.3722
5000
0.565
0.065
39.658 294.2611 344.2611
lb/hr
Btu/lbF
Btu/hrftF lb/ft3
K
K
Fluids
Water
Hexane
Iteration
Inner pipe
Outer pipe
Fluid properties
Temperatures
w
Cp
k
rho
Tin
Tout
n/a
1.006
0.388
59.975
210
180
5000
0.565
0.065
39.658
70
160
lb/hr
Btu/lbF
Btu/hrftF lb/ft3
F
F
h
265.6027
148.4528
Btu/hrft2F
3
Fluids
Water
Hexane
Pipe dimensions
Tave
ID
OD
195
3.068
115
4.026
F
in
in
Viscosity parameters
A
B
C
3.5
-52.843
3703.6
4.5
-6.3276
640
Pipe dimensions
Tave
ID
OD
363.7056 0.255667 0.291667
319.2611
0.3355
0.375
K
ft
ft
Deq
0.255667
0.043833
ft
Conduction computation
RePr
delr
dlm
delr/kdlm
180.0078
0.018 0.273272 0.002533
97.26962 n/a
n/a
n/a
ft
ft
Btu/hrftF
U
96.28843
84.40369
Btu/hrft2F
delT/Ud
1969.419
1969.419
Btu/hrft2
newTw
%diff
166.8022 n/a
161.8129 n/a
F
U
96.92324
84.96015
Btu/hrft2F
delT/Ud
1982.403
1982.403
Btu/hrft2
newTw
%diff
165.8066 2.773768
160.7843 2.920618
F
U
96.85265
84.89826
Btu/hrft2F
delT/Ud newTw
%diff
1980.959 165.7966 0.106807
1980.959 160.778 0.059151
Btu/hrft2 F
D
5.866 -5.9E-29
-0.694 5.69E+21
Area
k
0.051338
26
0.021591
26
ft2
Btu/hrftF
delT1
q
254250
254250
Btu/hr
delT2
50
A
34.49661
39.35402
ft^2
LMTD
110 76.09796
F
42.94894
42.94894
ft