You are on page 1of 6

MAINTAINANCE OF STEAM

TURBINES
TURBINE OVERHAUL
SCHEDULE
Minor overhaul Not more than 3years or 20,000-
25000 operating hours
Intermediate overhaul After 5-6 years or 40,000-50,000
operating hours
Major overhaul After 10-12 years or 1,00,000
operating hours
ESSENTIAL JOBS TO BE
CARRIED OUT DURING
OVERHAUL
1. Minor overhaul * When needed
2. Intermediate overhaul ** Recommended
3. Major overhaul *** Essential
Important aspects of successful
overhaul
1. List of spares needed
2. Spares availability
3. Condition of spares available
4. Usability of spares available
5. Personnel requirement
6. Tools available, special tools, special equipment
7. Workshop facility
8. Work to be done at site, at mfg works
9. Auxiliary equipment required
Important aspects of successful
overhaul contd
10. Duration of overhaul
11. Working time/ Shift programs
12. Improvements, modifications
13. Additional measurements before shut down to
determine the condition of the machinery
14. Crane and other lifting facilities etc.,