Professional Documents
Culture Documents
No.
Appliance
No. of
units
WC
basin
bath
shower
sink
washing machine
dish washer
14
3
7
4
6
4
4
Total units
Example
Size the foul water pipework for 12 houses from the DATA below in the table.
1.
2.
No.
Appliance
No. of
units
Total units
2
2
1
1
WC
basin
bath
shower
14
3
7
4
28
6
7
4
1
0
0
sink
washing machine
dish washer
6
4
4
Total
6
0
0
51
Flow graph gives 150mm-dia. foul drain since the convergence of the two
lines on the graph is between the pipe size 100mm diameter and 150mm
diameter.
SURFACE TYPE
AREA
IMPERMEABILITY
FACTOR (f)
(A) m2
TOTAL
(A x f)
Road or pavement
0.90
Roof
0.95
Path
0.75
Garden
0.25
0.90
Total
(A x f) 50
50
((litres/hour)
For example, size the pipework for 12 houses from the drawing
Example
Size the surface water pipework for 12 houses using the DATA below in the
table.
1.
2.
SURFACE TYPE
AREA
IMPERMEABILITY
FACTOR (f)
(A) m2
TOTAL
(A x f)
Road or pavement
20
0.90
18.00
Roof
40
0.95
38.00
Path
15
0.75
11.25
Garden
68
0.25
17.00
25
0.90
22.50
Total
192
Total
103.50
3.
(A x f)
103.50 x 50 =
50
50
5175 litres/hour
17.25 litres/second.
Flow graph gives 150mm dia. surface water drain since the point on the
graph lies between 100mm and 150mm