You are on page 1of 2

F

lexibility as defined in the design codes is a measure of the ability of a piping system

to absorb its own expansion and that of connected equipment to ensure that the loadings
do not cause :
o Fatigue failure of the piping system due to repeated overstress.
o Failure of the piping system due to excessive plastic strains.
o Leakage at any flanged joints.
o Overloading of valves and other components in the piping system which would
impair their operation.
o Detrimental distortion of connected equipment from excessive thrusts and
movements and machinery misalignment.

A flexibility analysis is required if the Stress Engineer is in any doubt as to the ability of
the system to satisfy the above requirements. Typically a comprehensive analysis is not
required if :
o They are duplication of successfully operating installations.
o They may readily be judged adequate by comparision with previously analyzed
systems.
o They are of uniform size, have no more than two points of fixation, no
intermediate restraints and fall within the limitations of the empirical equation
from ASME B31.3.

The following guidelines may be used for defining stress critical lines :
Process lines to and from strain sensitive eqipments such as pumps,
compressors and blowers.
Lines to and from steam turbines and reactors.
Lines with operating temperature differences from base temperatures >= 180C
for pipe sizes 6" and larger and >= 330C for pipe sizes 4" and smaller.
Process lines in toxic services for verification of flange leak tightness.
Two phase flow piping such as blowdown, and flare piping.
Non-metallic piping with design temperature above 50C.
All category "M" piping as defined in ASME B31.3.
Lines connected to wellheads (applies to onshore and offshore oil and gas
installations)
Lines subject to excessive deflection resulting from differential settlement (e.g.
lines connected to storage tanks), structural and/or equipment displacement.

Typically, engineering analysis, by visual inspection and quick manual calculations, are
performed on the following systems:
Lines >= 4" to air coolers.
Lines >= 16".
Lines with operating temperature differences from base temperatures >=80C for
piping sizes 6" and larger.
Lines subjected to vacuum or external pressure such as jacketed lines.
Relief systems - closed or relieving to atmosphere