You are on page 1of 1

(1 / 1 )

SP540V-016

NO.
DATE

2008.3.14

SERVICE INFORMATION
ROLAND DG CORPORATION / SERVICE DEPT.
TO ENGINEERS :

TO ENGINEERS

MODEL :

SUBJECT :
CHANGE OF THE MAIN BOARD

SP-540V
CONTENTS:

The Main Board has been changed due to the change of real time clock IC.

COMPATIBILITY:
The Firmware has been updated for the new real time clock IC. The Main Board which equips new
real time clock IC needs Firmware ver.6.60 and later. Compatibility of current and new Main Board
and Firmware is as follows.

Firmware Ver.6.50 and below


Firmware Ver.6.60 and later

Current Type Main Board


7876705100
SP-540V MAIN BOARD ASS'Y
Ver.1.0 - 1.2

New Type Main Board


6087670000
ASSY,MAINBOARD SP-540
Ver.2.0

**The version of the Main Board can be checked by the marks on the Main Board.
The version of new Main Board is 2.0.
EG. Ver.2.0

1 2 3 4 5 6 7 8 9
0 1 2 3 4 5 6 7 8 9

NOTE:
When Firmware ver. 6.50 and below is written on the new type Main Board, machine can not be operated at all. In this case, go to the Firmware Installation mode by turning on the Main Power SW while
pressing Up, Down and Left keys, and write the firmware ver.6.60 into the new type Main Board.
* The firmware cannot be written by other methods.
Once operation becomes possible, Firmware can be upgraded as usual.

SERIAL NUMBER:
SP-540V : TBAAW12773 and above

Revised 1

Revision No.

Date

Description of Changes

Approval

Issued by

07.7.6

First Edition

Kato

Misako

08.3.14

Serial Number has been revised.

Kato

Misako

-1-

DQF-7511-02--03_1