You are on page 1of 1

TORK PHOTOELECTRIC CONTROLS THERMAL

3000 SERIES

FLUSH MOUNTING
LEXAN HOUSING
APPLICATIONS
Use to control pole lanterns, lawn lights, walkway lighting.

Newgn
Desith
wi et
Gask

TORK

PHOTOCONTRO
HOTOCONTROL
L
FLUSH
MOUNTING
AUTOMATIC
ON AT DUSK
OFF AT DAWN
CONTROL OF
OUTDOOR
LIGHTING

FEATURES

USE FOR
POLE LANTERNS
FLOOD LIGHTS
LAWN LIGHTS
WALKWAY
LIGHTING

UL

MADE IN
U.S.A.

Control housing is weather-resistant molded Lexan


with ultrasonically welded seams.

Optional Clamshell

Built-in delay up to 2 minutes prevents false switching


due to momentary flashes of light.

UL

LISTED

SPECIFICATIONS
Turn ON / Turn OFF: Turn-ON is 1 to 5 fc, turn-OFF is 3 to
15 fc.

TORK

MODEL 3010
Flush mounting
for weatherproof
junction box.

Cell: Cadmium sulphide, epoxy coated 1/2 diameter.


Contacts: Normally closed. (Note: The unit fails in the ON
position)

PHOTOCONTRO
HOTOCONTROL
L
FITS FS TYPE OUTDOOR
JUNCTION BOX

STAINLESS STEEL PLATE


AND GASKET INCLUDED

AUTOMATIC
ON AT DUSK
OFF AT DAWN
CONTROL OF
OUTDOOR
LIGHTING

Power Consumption: Averages under one watt.


Temperature Range: -40 to +140F (-40 to +60C)
Mounting:
Model 3000 - flush mounting through 11/16 hole in post
lantern or lighting fixture. 3/8 npt. Stem is 3/4 long.
Gasket and nut supplied.

VOLTAGE
50-60Hz

TUNGSTEN

BALLAST

120

1500W

1200VA

3000C

3/4"

5/8"
O.D.

2"

RATING
3/4"

1"

1-1/2"

Same specs as above but in clam shell package

3002

208-277

1500W

1200VA

3010*

120

1500W

1200VA

3010C

DIMENSIONS

ORDERING INFORMATION

3000

Optional Clamshell

Model 3010 - flush mounting into standard raintight, junction box.

MODEL

UL

MADE IN
U.S.A.

Same specs as above but in clam shell package

* Includes plate and gasket to fit FS type outdoor junction box.

WIRING DIAGRAMS
120V
MODELS

Line (Black)

(Red)

Neutral (White)

Lamp

SPECIFICATION WRITERS GUIDE


Photocontrol enclosure shall be constructed of Lexan
material with ultrasonically welded seams. Cell shall be
cadmium sulphide, epoxy coated, 1/2 inch diameter.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40 to
+140 F. Unit to be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105 C.
1. Photocontrol shall be capable of flush mounting. Furnish
and install TORK Model 3000, 120 VAC (Model 3002,
208-277 VAC) or equal.
2. Photocontrol shall be provided with a steel plate Model
3010, 120 VAC.

208-277V
MODELS
240V
L2
L1

TORK

Line (Black)

(Red)

(White)

Load

For 277VAC:
L1 - Line
L2 - Neutral

1 Grove St., Mt. Vernon, NY 10550 Tel: 914-664-3542 Fax: 914-664-5052 Internet: http://www.tork.com