You are on page 1of 2

ACCEPTANCE FORM FOR TELKOMSEL PROJECT

INDOOR INSTALLATION VALIDATION CHECK (INSTALLATION AUDIT)


ANTENNA INSPECTION
ANTENNA INSPECTION
Purpose of these inspection :
1. Check that the signal level of antenna below or 1metre away from antenna)
2. Validation check for any damage and clean.
NO
1

ITEM
Signal Level

Signal quality

Drop Call (Drive Test)

Hand off success


(Drive Test)
In/Out Building Handoff

Spill out

Elevator coverage

Detail design data

Frequency Scan list

10 Drive Test

CRITERIA
a. Signal level RSCP of -90 dBm or better for 95% of
target area at High Rise (above level 10) and
Signal level RSCP of 92 dBm or better for 95% of
target area at Low Rise (Below level 10).
b. Signal level RSCP of -85 dBm Idle Mode
c. EcNo Value of 0 thru -12dB for 95% of data
collected to meet criteria a.
d. EcNo value of 0 thru -12dB for 95% of data Idle
e. Drop call rate of maximum 2% for all calls
made to meet criteria a.
f. HO Success rate of 100% for all calls made to
meet criteria a.
g. Demonstrate smooth handover to outdoor
sites at all public entry/exit points of the
building including car parking.
h. Perimeter of building should be served by
outdoor sites.
i. Coverage inside each public elevator should
be sufficient to maintain a phone call.
j. Detail floor plans, vertical and horizontal
designs, and antenna placement drawings.
k. Scan all GSM900 and GSM1800 frequencies
owned by Telkomsel.
l. Walk test plots for signal level and quality
(Plots according to Telkomsel specification)

ACTUAL
COMPLIANCE
MEASUREMENT

100.00%
99.29%
99.96%

0%

100%

Bank BCA Surabaya


25/09/2014
PT. TELKOMSEL

94.42%

Acceptance Form For TELKOMSEL


Site Name :
Date
:

PT. NEXWAVE

REMARK

RSCP Distribution Comparison

-40<=x<-15
-50<=x<-40
-60<=x<-50
-70<=x<-60
-75<=x<-70
-85<=x<-75
-90<=x<-85
-95<=x<-90
-100<=x<-95
-135<=x<-100

Idle Mode
Dedicated mode
Sample
%
Sample
%
107
1.77%
2229
2.27%
3013
49.74%
48499
49.36%
2206
36.41%
44400
45.19%
656
10.83%
2842
2.89%
18
0.30%
256
0.26%
15
0.25%
22
0.02%
0
0.00%
0
0.00%
0
0.00%
0
0.00%
0
0.00%
0
0.00%
43
0.71%
0
0.00%
6058
100.00%
98248 100.00%
99.29%
100.00%
10.00%
10.00%

Drop call ratio


Dropped Call
Call established
Call end

0
16
15

0.00%

CSSR
Call Attempt
Blocked Call
Call Setup

16
0 100.00%
16

CCR

100.00%
SHOSR

Soft Handover
Soft Handover failure

0
100.00%
0

Ec/No Distribution comparison

-12<x<=-33
-9<=x<=-12

PT. NEXWAVE

IDLE Mode
DEDICATED Mode
Sample
%
Sample
%
338
5.58%
39
0.04%
435
7.18%
519
0.53%

-6<=x<-9

704

11.62%

5854

0<=x<-6

5.96%

4581

75.62%

91836

93.47%

6058

100.00%

98248

100.00%

94.42%

99.96%

25.00%

25.00%

Parameter
RSCP -92dBm (%)
Avg RSCP (dBm)
Ec/No -12dB (%)
Avg Ec/No (dB)
BLER 1% (%)
BLER
Avg CST (ms)
Event
Call Attempts
Blocked Calls
Dropped Calls
CSSR (%)
CCR (%)
SHO Success
SHO Failure
SHO Success Rate (%)

RS.RAJAWALI-BANDUNG

Idle
99.29%

Dedicated
100.00%

94.42%

99.96%

Dedicated
16
0
0
100.00%
100.00%
0
0
100%