You are on page 1of 3
Paget ST. LOUIS COUNTY POLICE DEPARTMENT CRIME LABORATORY ANALYSIS REPORT urs: 099 Complaint: 2014 = 43986 Sheol: 11 Ham: 1 Report Physical Evidence [ree anew lrearase iris Name: ST. LOUIS COUNTY Lab Number 088-2016.43904 Offense: ASSAULT ONL.E.O. | Security Bag No | Dele of Cccurrence: a/ey2014 Number of Boxes: | | Location: 2947 CANFIELD |PackagesiMisc 4 Precinct/Bureau: CAP [Department Name: ST. LOUIS COUNTY Entered On: 09/03/2014 Entered By: SPECIMEN St: EPER.BULET ACETONE SBE.ORE TORE 9A, MOM" aELOHS3A| | (143.2 9") | ma | ‘SPECIMEN QB6 WAS COMPARED MICROSCOPICALLY WITH TEST-FIRED SPECIMENS TB1A,B8 AND IDENTIFIED FOR | HAVING BEEN FIRED FROM THE PREVIOUSLY DESCRIBED PISTOL, SPECIMEN GF, BASED ON THE SUFFICIENT | quarry ano QUALITY oF WATCHING NDIVDUAL CHARACTERISTICS IN THE RFLING STRIATIONS. FIREARM EXAMINER CONCURRED. | The undersined does hereby certify under ReMo 644.376 thatthe above and foregoing a tue and accurate copy of he result of ab fests conducted. Forensic Scientist Date/Time of Analysis: 9/08/2014 Signature Disposition of Evidence: SENT TO PROPERTY CONTROL, sadn eer om_10-3 oe oe Pege ST. LOUIS COUNTY POLICE DEPARTMENT CRIME LABORATORY WEAPON ANALYSIS REPORT Jats: 089° Gornplin 2014-49084 Shest_ = Ba, 1 Report _ Physical Evigence _ Reporting Juris: 098 1] Precinct Log Ne: Juris Name: ST. LOUIS COUNTY Lab Number 090-2014-43984 j Offense: ASSAULT ON LEO Security Bag No Date of Occurrence: si8v2014 Number of Boxes: 4 | Location: 2947 CANFIELD |_Paokagesmiisc: 4 { Officers Osn: Precinct/Bureau: CAP Department Name: ST, LOUIS COUNTY J Entered On: 08/11/2014 Entered By: Date: art272014 DeteRecieved: 8/11/2014 Make: SIG SAUERINC. (EXETER, NH.) Model: P229 ColiberGauge: 4088 Type: PISTOL Finish: BLAGK No, Lands/Grooves: 8 Twist: LEFT Serial Number: $88 003784 SIN Location: RIGHT SIDE FRAME Cepaciy/Type: 12 IN MAGAZINE Safely: NONE Operational”: WA Defects: APPARENT BLOOD WAS CLEANED FROM THE FIREARM BEFORE ANALYSIS, THE FIREARM IS IN OTHERWISE NORMAL FIRING CONDITION. Trigger Pull $A: N/A DA: NIA Flares.on Oy: NIA Cyl Rotation: NA Bore Condition: RESIDUE BarelLengty 3.3/4" ‘Muzzle fo Trigger Longth: N/A Action: SEMIAUTOMATIC Cartidges: 4 (FEDERAL) JHP. Bullets: § {061-5} Discharged Shells: 42 [QC1-12} Fragmants Received: NIA ‘Test Shots Fired: TEST-FIRED BULLETS [TB1A,B], CASES [TC1A,B] WERE FIRED USING THIS FIREARM [QF1] AND RETAINED, SEE ADDITIONAL ANALYSIS INFORMATION. The undersigned does hereby certify under RsMo 644.376 thatthe ebove and foregoing isa true and accurate copy ofthe results of ab tests conducted. Disposition of Evidence: SENT TO PROPERTY CONTROL, Seal No; N/A Information as of aMaron4g | rcnreome a | ‘Admiisrstve Appcoval By Pago? ST, LOUIS COUNTY POLICE DEPARTMENT CRIME LABORATORY WEAPON ANALYSIS REPORT ura: of ‘Complain 2014 - 42084 Sheet. «om 1 SPECIMENS: Q81 - COPPER JHP BULLET (DAMAGED), .40 CAL., 6-L, FROM "FPD VEH, 108", (188.0 gr) {CSU #7) (QB2 - COPPER JHP BULLET (DAMAGED), FROM BROWN'S “RIGHT SIDE OF BACK". (177.0 gr.) (CSU #14) ‘QBS - COPPER JHP BULLET (DAMAGED), "(1828 gr) {CSU #15) (QB4- COPPER JHP BULLET (OAMAGED), 40 CAL. 6-L, FROM BROWN'S “RIGHT SIDE OF HEAD". (151.0 gr.) {CSU #16) ‘QB5- COPPER JHP BULLET (DAMAGED), 40 CAL., 6-L, FROM "ROADWAY". (180.2 r) {CSU #17} (C142 - TWELVE FIRED CARTRIDGE CASES (FEDERAL), .40 SW CALIBER. {QC1,2 ARE CSU'S ITEMS 3,4 FROM "STREET IN FRONT OF 2964 CANFIELD"; QC3 IS CSU'S ITEM 10 FROM “STREET 2943 ‘CANFIELD"; 04,5 ARE CSU'S ITEMS 11,12 FROM "GRASSY AREA BETWEEN ROAD/SIDEWALK ON SOUTH SIDE OF ROAD"; QC8-10 ARE CSU'S ITEMS 13-18 AND 48 FROM "ROADWAY IN FRONT OF 2943 CANFIELD"; AND QC11,12 ARE (CSU'S ITEMS 21,22 FROM "GRASSY AREA BETWEEN ROAD AND SIDEWALK ON SOUTH SIDE OF ROAD") NARRATIVE! ‘SPECIMENS QB1-5 WERE COMPARED MICROSCOPICALLY WITH EACH OTHER AND TEST-FIRED SPECIMENS TB1A,B. IDUE TO THE DAMAGE SUSTAINED BY SPECIMEN QBt, IT WAS INCONCLUSIVE, HOWEVER, SPECIMENS Q82-5 WERE IDENTIFIED FOR HAVING BEEN FIRED FROM THE DESCRIBED PISTOL, SPECIMEN QF1, BASED ON THE SUFFICIENT i: [QUANTITY AND QUALITY OF MATCHING INDIVIDUAL. CHARACTERISTICS IN THE RIFLING STRIATIONS. | SPECIMENS QC1-12 WERE COMPARED MICROSCOPICALLY WITH EACH OTHER AND TEST-FIRED SPECIMENS TC1A,8. THESE SPECIMENS WERE IDENTIFIED FOR HAVING BEEN FIRED IN THE DESCRIBED PISTOL, SPECIMEN QF1, BASED ON ‘THE SUFFICIENT QUANTITY AND QUALITY OF MATCHING INDIVIDUAL CHARACTERISTICS IN THE BREECH FACE IMPRESSIONS. FIREARM EXAMINER CONCURRED. if v7 Ania ber re dala

You might also like