DECS-200 File Name: Settings File Print Out My Folder\Projekti\Basler za GiM\BASLER - GiM\MHE_Gozna .de2 BESTCOMS Version: 1.05.00 Model Number: DEcs-200 Style Number: ic Part Nunbei 9360101014 App Version 1.03.02 DSP Version: 1.03.01 Boot Version. 2.10.00 Serial Number: Comm Settings: 9600 9600 9600, 247, 10,N, 2 4. sijeeanj 2013 15215139 SHEP GOZNA Comments: detsteasesetseeaneenstene System Configuration *#tsttereeseeseseeeanenes System Operating Mode System Control Mode System Operating Status: Limiter Mode: Underfrequency Node: Sensing Configuration: Generator Frequency: Voltage Matching Switch Generator PT Primary Voltage: Generator PT Secondary Voltage Generator CT Primary Current: Generator CT Secondary Current: Bus PT Primary Voltage: Bus PT Secondary Voltage: Internal Tracking Enable: Internal Tracking Time Delay: Internal Tracking Traverse Rate: External Tracking Enable: External Tracking Time Dela: External Tracking Traverse Rate Generator Rated Apparent Power: Generator Rated Power Facto: Generator Rated Real Power: Exciter Field Rated Resistance: Generator Rated Voltage: Generator Rated Current Generator Rated Field Voltage: Generator Rated Field Current: Pole Ratio ~ Exciter Poles/Generator Pole stop AVR Droop SCL/OEL/UEL, UF ‘Three Phase 50 Hz oft 6.300 Vac. 110 vac 150 Aac 1 aac 6.300 vac 10 vac Enabled 0,1 Sec(s) 20,0 Secis) Disabled 0,1 Sec{s} 20,0 Secs} 1604,05 KVA 0,80 1283, 24 KW 10,55 Ohms 6.300 Vac 147,0 aac 15,0 Vdc 10,9 Ade 1,00 Auxiliary Input Type: Auxiliary Input Summing Type: (avR/ECR) AVR Node Auxiliary Input Gain: FOR Mode Auxiliery Input Gain: var Node Auxiliary Input Gain AVR PF Auxiliary Input Gain: Reactive Droop Compensation: Cross Current Compensation Gain: Page 1 Voltage Inner Loop 1,00 2,00 1,00 1,00 5,0 % 0,00 $ DECS-200 Settings File Print Out setevsseeensensseesensens Setting Adjustments *#4+thertesresttieesenen AVR AVR AVR AVR AVR SetPoint: Minimum Setpoint: Maximum Setpoint Pre-position Traverse Rate: Pre-position Mode: Setpoin’ Minimum Setpoint Maximum Setpoint: Pre-position: Traverse Rate Pre-position Mode 6304, 68 Vac 95,0 8 105,0 & 6.300,0 vac 20 Sec(s) Release 0,00 Ade 0,0 8 105,0 & 0,00 ade 20 Sec(s) Release var, var var PF PE PE PE PE Gen Gen SetPoint: /BF Voltage Band: Minimum Setpoint Maximum Setpoint Pre-position: ‘Traverse Rate: Pre-position Mode: SetPoint: Maximum Setpoint (Leading): Maximom Setpoint (Lagging) : Traverse Rati Pre-position Mode: 0,00 kvar 20,00 ¥ “40 4 of rated vA 60 $ of rated VA 0,00 kvar| 20 Sec(s) Release 1,000 0,920 0, 800 20 Secis) Release erator Voltage Soft Start Bias: erator Voltage Soft Start Time Underfrequency Setting (Corner Frequency): Und Vou vol EL EL. lerfrequency Setting (Slope): tage Matching Band: ‘tage Matching Level (Generator to Bus): 58 5 Sec(s) 47,0 He 1,00 V/Hz 5,00 & (nom. 100,0 ¢ styl Option: Off-Line OEL Setting - High Current Level: Off-Line OEL Setting - High Current Time: Off-Line OFL Setting - Low Current Level ont oni on-i ont on- Take Take Take Take ‘Take Tak ‘Line OEL ‘Line OEL Setting - High Current Line OEL Line OEL Line OEL Setting - Low Current Setting - Medium Current Leve: Setting - Medium Current Time ‘Setting - High Current Level: Time: Leve: Summing Pt Option 1 5,5 Ade 6 Sec(s) 4,0 Ade 18,6 Adc 6 Secis) 11,5 Ade 120 Sec(s) 10,9 Ade eover Limiter eover Limiter eover Limiter Off-line Timedial eover Limiter eover Limiter eover Limiter On-line Timedial: Off-line High Current Level: Off-line Low Current Level On-line High Current Level: On-line Low Current Level: Page 2 Amps Amps: 0 0 el 70 Amps 70 Amps 1 DECS-200 Settings File Print Out UEL Curve Type Selection: Internal. UEL Curve = lst Point kW Generate: 0 kW UEL Curve = 1st Point kvar Absorbed: 640 kvar UEL Curve = 2nd Point kW Generate o KW UEL Curve = 2nd Point kvar Absorbed: 0 kvar UEL Curve = 3rd Point kW Generate: 0 kW UEL Curve = 3rd Point kvar Absorbe: 0 kvar UEL Curve = 4th Point kW Generate: 0 kW UEL Curve = 4th Point kvar Absorbe 0 kvar UEL Curve = Sth Point ki Generate: 0 kW UEL Curve = 5th Point kvar Absorbed: 0 kvar Stator Current Limiter Initial Delay: 0,0 sec Stator Current Limit Hi Value: 220,5 Amps Stator Current Limit Hi Time : 3,0 sec Stator Current Limit Low Value: 429,0 Amps daweatsesesteeneesenernensee® Control Gaing +#tttthitineesesessenenmnnses Stability Range (Gain Table Index): 21 AVR/ECR ~ Proportional Gain KP: 30,0 AVR/FCR - Integral Gain KI: 150,0 AVR/FCR - Derivative Gain KD! 2,0 AVR/ECR - Derivative Gain TD: 0,08 AVR - Loop Gain Kg: 3,0 FCR - Loop Gain Kg 25,0 PE - Integral Gain KI: 120,0 var - Loop Gain Kg: 1,00 PE - Loop Gain Kg: 1,0 SCL Integral Gain KT: 10,0 SCL Loop Gain Kg: 1,0 OEL - Integral Gain KI: 10,0 EL - Loop Gain Kg: 1,0 UEL Integral Gain KI 10,0 UEL Loop Gain Kg: 2,0 Voltage Matching - Loop Gain Kg: 1,0 sttetttieseeenenneceeense Protection Settings *##tsteteresseesensienes Generator Overvoltage: Enabled Generator Undervoltage Enabled Exciter Field Overvoltage Enabled Exciter Field Overcurrent: Enabled Exciter Open Diode: Disabled Exciter Shorted Diode: Disabled Loss Of Field: Enabled Loss Of Sensing Voltage: Enabled Loss of Sensing Time Delay: 0,1 Sec(s) Loss of Sensing Balanced Level: 50,0 & Loss of Sensing Unbalanced Level: 20,0 & Transfer To FCR Mode: Enabled Page 3

You might also like