You are on page 1of 15

&

BL1 150
BL1 200
BL1 300

HYDRAULIC CONNECTION DIAGRAMM


INSTALLATION EXAMPLE BL1 150
INSTALLATION EXAMPLE BL1 200
INSTALLATION EXAMPLE BL1 300

BL1

INSTALLATION EXAMPLE BL1

BL1 200 ME
420, 500, 800, 1000 lt

OR BL1 200 WITH SIDE FLANGE


420, 500, 800, 1000 lt

BL2 200
BL2 300

INSTALLATION EXAMPLE BL2 200


INSTALLATION EXAMPLE BL2 300

BL2

INSTALLATION EXAMPLE BL2

BL0 150
BL0 200
BL0 300

INSTALLATION EXAMPLE BL0 150


INSTALLATION EXAMPLE BL0 200
INSTALLATION EXAMPLE BL0 300

BL0

INSTALLATION EXAMPLE BL0

H BL2 200 ME
420, 500, 800 & 1000 lt

H BL0 200 ME
420, 500, 800, 1000 lt

BUFFER TANK
ANK IN TANK

OR BL2 200 WITH SIDE FLANGE


420, 500, 800, 1000 lt

OR BL0 200 WITH SIDE FLANGE


420, 500, 800, 1000 lt

INSTALLATION EXAMPLE BUFFER TANK


INSTALLATION EXAMPLE ANK IN TANK

BUFFER 1

WARNING
HYDRAULIC AND ELECTRICAL CONNECTIONS
MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

WATER OUTLET

1''

1/2''
ERMOMETER POSITION

RECIRCULATION

1''

()
(OPTIONAL )

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS


FROM SOLAR PANEL
OR BOILER

1''

IMMERSION ELEMENT POSITION


1/2''
THERMOSTAT POSITION

TO SOLAR PANEL
OR BOILER

1''
1''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
ITI
NG
VA

LV

R E
TU
R N

VA
EX

LV
7- P A
E
8 N S
IO
N
R E
LIE
FV
AL
VE

11/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL1 150

DRAINAGE

INSTALLATION EXAMPLE BL1 150


BL1 150 GE n

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL1 150

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

1''

WATER OUTLET

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS


FROM SOLAR PANEL
OR BOILER

RECIRCULATION

11/2''
1''

()
(OPTIONAL)

IMMERSION ELEMENT POSITION


THERMOSTAT POSITION 1/2''

TO SOLAR PANEL
OR BOILER

1''
1''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
ITI
NG
VA

LV
E



RE
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
FV
AL
VE

ERMOMETER POSITION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL1 200

DRAINAGE

INSTALLATION EXAMPLE BL1 200

BL1 200 GE n

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL1 200

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

BL1 300

1''

WATER OUTLET

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

RECIRCULATION

()
(OPTIONAL)

11/2''

IMMERSION ELEMENT POSITION

1''

FROM SOLAR PANEL OR BOILER


1/2 ''
THERMOSTAT POSITION

TO SOLAR PANEL
OR BOILER

120 SIDE FLANGE


(access door )
(
)

1''
1''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

ERMOMETER POSITION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL1 300

DRAINAGE

H BL1 200 ME

I NSTALLATION EXAMPLE BL1 300


OR BL1 200 WI TH SIDE FLANGE

BL1 300 GE

11/4''

WATER OUTLET

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

RECIRCULATION

()
(OPTIONAL)

11/2''

IMMERSION ELEMENT POSITION

11/4''

FROM SOLAR PANEL OR BOILER


1/2''
THERMOSTAT POSITION

TO SOLAR PANEL
OR BOILER

120 SIDE FLANGE


(
(access door)
)

11/4''
11/4''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
ITI
NG
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 N S
IO
N
R E
LIE
F
VA
LV
E

ERMOMETER POSITION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL1

DRAINAGE

420, 500, 800, 1000 lt

I NSTALLATI ON EXAMPLE BL1


420, 500, 800, 1000 lt

BL1 GE

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL1 420, 500,


800, 1000

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

1''

WATER OUTLET

WARNING
HYDRAULIC AND ELECTRICAL CONNECTIONS
MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS
USE HEMP WITH A LIQUID THEAD SEALANT
TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS


FROM BOILER


THERMOSTAT POSITION 1/2 ''

TO BOILER

1''


FROM SOLAR PANEL

1''

ERMOMETER POSITION

RECIRCULATION

1''

11/2''

()
(OPTIONAL )

IMMERSION ELEMENT POSITION


1/2 ''
THERMOSTAT POSITION

TO SOLAR PANEL

1''
1''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

1''

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL2 200

DRAINAGE

INSTALLATION EXAMPLE BL2 200


BL2 200 GE n

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL2 200

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

1''

WATER OUTLET

WARNING
HYDRAULIC AND ELECTRICAL CONNECTIONS
MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS
USE HEMP WITH A LIQUID THEAD SEALANT
TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS


FROM BOILER


TO BOILER

1''


FROM SOLAR PANEL

ERMOMETER POSITION

RECIRCULATION

1''


THERMOSTAT POSITION 1/2''

()
(OPTIONAL )

11/2''

IMMERSION ELEMENT POSITION

1''


1/2''
THERMOSTAT POSITION

TO SOLAR PANEL

120 SIDE FLANGE


(access door )
(
)

1''
1''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

1''

1/2 ''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL2 300

DRAINAGE

H BL2 200 ME

I NSTALLATION EXAMPLE BL2 300


OR BL2 200 WI TH SIDE FLANGE

BL2 300 GE

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL2 300

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

11/4''

WATER OUTLET

WARNING
HYDRAULIC AND ELECTRICAL CONNECTIONS
MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS
USE HEMP WITH A LIQUID THEAD SEALANT
TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS


FROM BOILER


TO BOILER

11/4''


FROM SOLAR PANEL

ERMOMETER POSITION

RECIRCULATION

1''


THERMOSTAT POSITION 1/2''

()
(OPTIONAL)

11/2''

IMMERSION ELEMENT POSITION

11/4''


1/2''
THERMOSTAT POSITION

TO SOLAR PANEL

120 SIDE FLANGE


(
(access door )
)

11/4''
11/4''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

11/4''

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL2

DRAINAGE

420 , 500, 800 & 1000 lt

I NSTALLATI ON EXAMPLE BL2


420, 500, 800, 1000 lt

BL2 GE

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL2 420, 500,


800, 1000

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS


WATER OUTLET

1''

1/2 ''
ERMOMETER POSITION

RECIRCULATION
()
(OPTIONAL)

1''

11/2''
IMMERSION ELEMENT POSITION

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

1''

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

MAINS SUPPLY

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL0 150

DRAINAGE

INSTALLATION EXAMPLE BL0 150


BL0 150 GE n

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL0 150

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

1''


WATER OUTLET

1/2 ''

ERMOMETER POSITION

RECIRCULATION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

()
(OPTIONAL)

11/2 ''
IMMERSION ELEMENT POSITION

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

1''

P R
ES
3 S UR
E L
IM
ITI
NG
VA

LV

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS
IO
N
R E
LIE
F
VA
LV
E

MAINS SUPPLY

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL0 200

DRAINAGE

INSTALLATION EXAMPLE BL0 200

BL0 200 GE n

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL0 200

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

1''


WATER OUTLET

1/2''

ERMOMETER POSITION

RECIRCULATION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

11/2''

()
(OPTIONAL)

IMMERSION ELEMENT POSITION

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

120 SIDE FLANGE


(access door)
(
)

1''

P R
ES
3 S UR
E L
IM
IT
IN
G
VA

LV
E

R E
TU
R N

VA
EX
LV
7- P A
E
8 NS
IO
N
R E
LIE
FV
AL
VE

MAINS SUPPLY

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL0 300

DRAINAGE

H BL0 200 ME

I NSTALLATI ON EXAMPLE BL0 300


OR BL0 200 WI TH SIDE FLANGE

BL0 300 GE

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL0 300

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()


WATER OUTLET

11/4''

ERMOMETER POSITION

RECIRCULATION

1''

WARNING

HYDRAULIC AND ELECTRICAL CONNECTIONS


MUST BE PERFORMED ONLY BY COMPETENT
LICENCED TECHNICIANS ACCORDING
TO EXISTING STANDARDS AND REGULATIONS

11/2''

()
(OPTIONAL)

IMMERSION ELEMENT POSITION

USE HEMP WITH A LIQUID THEAD SEALANT


TO SEAL ALL HYDRAULIC FITTINGS
(INCLUDING ELECTRIC IMMERSION HEATER
IF ANY) AND CHECK FOR LEAKS

120 SIDE FLANGE


(access door)
(
)

11/4''

MAINS SUPPLY

P R
ES
3 S UR
E L
IM
ITI
NG
VA

LV
E

R E
TU
R N

EX
VA
LV
7- P A
E
8 NS

IO
N
R E
LIE
F
VA
LV
E

1/2''

EXPANSION
VESSEL

8-12% V

ALL CONNECTIONS ARE FEMALE TUBE THREADS

BL0

DRAINAGE

420, 500, 800, 1000 lt

I NSTALLATI ON EXAMPLE BL0


420, 500, 800, 1000 lt

BL0 GE

PDF created with pdfFactory Pro trial version www.pdffactory.com

BL0 420, 500,


800, 1000

MAGNESIUM ANODE
ROD (RODS)

&

&


AUXILIARY FLANGE
110

()

BUFFER TANK

1/2"

11/2''

11/2'' ... F.C.U.


1/2"

( 1 150)

... F.C.U.

11/2''

11/2''

SOLARNET S.A.


BUFFER TANK


TANK-IN-TANK (
)


, .

HW
10
6
4

CW

9
8

M
7

2
M

11

When using TANK-IN-TANK storage tanks, we


use, in priority, solar energy for space heating
and DHW production and as auxiliary source,
oil or gas burner.

3
1

1. -/ Gas-Oil Boiler
2. -/circulation pump
3.  ASSOS, TIT (
) / ASSOS storage tank, type TIT
4. /solar collectors field
5.  /recirculation
pump
6. /Underfloor heating
7. ON/OFF /3way valve
8. /check valve
9. /Cold water inlet
10. /Hot water outlet
11.  /Analog 3 way
valve


ANK IN TANK

You might also like