You are on page 1of 4
UP AK IY I BIN ADIN: T 20) 0 CYLINDER TYPE SAMPLING SYSTEMS TSI LPG SAMPLERS ENABLE OPERATORS TO OBTAIN REPRESENTATIVE SAMPLES OF GAS OR LIQUIDS WITH HIGH VAPOR PRESSURES. THE SAMPLE IS CAPTURED IN A SAMPLE CYLINDER FOR EASY TRANSPORT TO THE LAB, TEXAS SAMPLING’S PATENTED DESIGN ENSURES SAFE, PROPER ALIGNMENT USING CYLINDER SADDLES AND PREVENTS LEAKAGE WHEN CONNECTING THE CYLINDER. FOR MAXIMUM OPERATOR SAFETY, OUR LSL LIQUID SAMPLER DESIGN ALLOWS THE OPERATOR TO MAINTAIN THE PROPER OUTAGE. ANY EXCESS PROCESS LEFT IN ‘THE SYSTEM IS VENTED SO THAT THE PRESSURE IN THE QUICK CONNECTS IS REDUCED. SIMPLE TWO VALVE OPERATION AND THE EASY ON/ OFF DESIGN OF THE SAMPLE CYLINDER MAKES THE TEXAS SAMPLING SYSTEM AN EXCELLENT CHOICE FOR ANY HIGH VAPOR PRESSURE LIQUID OR GAS APPLICATION. E PRESSURE LIQUIDS FOR SAMPLE POINTS WITH A PROCESS RETURN. SIGHT GLASS IS INCORPORATED IN THE DESIGN TO PERFORM TWO FUNCTIONS, FIRST (TIS USED To VERIFY THAT THERE Ig PROCESS FLOW THROUGH THE SAMPLE )SVSTEM ENSURING THAT A REPRESENTATIVE SAMPLE Is TAKEN. SECONDLY, THE SIGHT GLASS IS USED TO VISUALLY VERIFY THAT THERE IS AN OUTAGE INTHE SAMPLE CYLINDER. ALSO ANY RESIDUAL PROCESS REMAINING IN THE CYLINDER AFTER ANALYSIS CAN BE FLUSHED BACK INTO THE PROCESS MINIMIZING THE NEED TO CLEAN THE CYLINDER BETWEEN SAMPLES THE L5G SAMPLE SYSTEM IS DESIGNED FOR TAKING SAMPLES OF GASES on VAPOR IN APPLICATIONS WHERE A PROCESS RETURN IS AVAILABLE, THE SAMPLE CYLINDER (S FILLED FROM THE TOP TO FLUSH ANY LIQUIDS On CONDENSED VAPORS SACK TO THE PROCESS 10 PREVENT CONTAMINATION FROM THE FRESH SAMPLE. A PRESSURE GAUGE IN INCORPORATED IN THE DESIGN TO INDICATE THAT PROCESS PRESSURE ISIN THE SAMPLE SYSTEM DURING SAMPLE COLLECTION. AN ARMORED ROTAMETER CAN BE ADDED AS AN OPTION To VENIFY FLOW THROUGH SYSTEM ET ead SOME SAMPLE POINTS DO NOT HAVE THE ABILITY TO RETURN FLOW BACK TO THE PROCESS. THE LR SERIES IS DESIGNED SPECIFICALLY FOR THESE APPLICATIONS. A FLOW CONTROL VALVE IS USED TO FLUSH THE SAMPLE SYSTEM WITH PROCESS FLUID AND SEND IT TO THE VENT SYSTEM FOR PROPER DISPOSAL. AVAILABLE FOR LIQUIDS AND GASES. TT = “THE LP SERIES IS USED IN APPLICATIONS WHEN THERE IS A REQUIREMENT TO FLUSH THE PROCESS FROM THE SAMPLE SYSTEM PRIOR TO DISCONNECTING THE SAMPLE CYLINDER. COMPRESSED AIR OR AN INERT GAS IS USED TO PURGE THE PROCESS FROM THE CYLINDER CONNECTIONS AND OUT THE VENT CONNECTION ENSURING THE CONNECTIONS ARE CLEAN AND DRY BEFORE THE CYLINDER IS REMOVED. AVAILABLE FOR LIQUIDS AND GASES. ADD L FOR LIQUID OR G FOR GAS TEXAS SAMPLING, INC. LSL - 1/4" LPG Liquid Sample System - Gauge Range (Max operating pressure should be 70% of 1 0-300 2 0-600 3-0-1000 40-2000 (high pressure option) Cylinder Assembly Opti ‘A 150 CC Sample Cylinde 8 300 CC Semple Cylinder C500 CC Sample Cyli X Without (Customer to: Cylinder Options 1 Diptube 2. Swagelok Quick Connects (C4, QC other series all factory) 3. Relief Valve X Without ‘System Options A High Pressure (000 psig upto 2000 psig @ 100 F) X Without Process Connections 1 38" - 172" Tube 2 3/8" 1/2" NPT or Socket Weld 3 Up to 3/4" x 150# Flange X_1Wa" Tube Connection Block Valves - 1/4" , A High temp ball vaive (for use with temperatures up to 450F) 5 B Process block valve 1/4" ball type (for use with temperatures up to 350°F) + ) C Needle valve D Other process Hock valve é E Check Vane X without Vent Options 1 Emission Filter (Actvated Carbon in SS Canister) 2 Emission Filter wth crystals toindicate when carbon needs changing X Without PS Pipestand (2° x 48" Galvanized with 10" x 10" base) Without ‘ Enclosure all 304 SS_ NN. Non-Insulated IE Insulated with Electric Heater 7 IS Insulated with Steam or Giycol heating cols mounted aa X Without = Goolers - High Efficiency Tube in a tube counter flow (includes: = TV & Tl in thermowell, H2O block valves, plate mounted) 3 C13 1/4" X 12" X 30° Gia 114" X 170" X40 s C22 3B" X 3/4" X 20° Recommended for temperatures C23. 3/B" X 3/4" X 30° greater than 130'F. Cooling Data C24 3B" X 3/6" X 40° ‘Sheet must be submitted for 632 V2"X 3M" X20 | proper sizing 638 12°X 31a" X30 36 12° K 314" X 40° Xx Without Miscellaneous KI Keltez orig 4way sample valve nr) 2 Kelrez orig check valve 3 Parker QC w/ Kairez oring add 3 wks to delivery F Specify itings other than standard Hoke Xp Without [ists] — PRESSURE VS. TEMPERATURE “Limited By Pressure Guage Range OPTIONS PROCESS BLOCK VALVES ~ ISOLATES SYSTEM FROM PROCESS STREAM GRAPHOIL PACKED VALVES - PROVIDES IMPROVED FIRE-SAFE CAPABILITIES ( NOT API 607 RATED) COOLERS - AVAILABLE IN A VARIETY OF SIZES TO COOL PROCESS BEFORE DISPENSING INTO SAMPLE CYLINDER. CARBON CANNISTER ~ ABSORBS VENTED VAPORS FROM SYSTEM. INSULATED ENCLOSURE - MAINTAINS CONSTANT TEMPERATURE USING STEAM OR ELECTRIC HEAT. SIGHT FLOW INDICATOR us tae | BYPASS 1a TUBE VENTTO cont ee FLARE ee TUBE CONN. SAMPLE IN -a* TUBE CONN, LRL - LPG Liquid without Return systew onmpes sf pRtSSOMe couple ontNDEE ‘CYLINDER VALVE NON-INSULATED ENCLOSURE - PROVIDES PROTECTION FROM THE ENVIRONMENT; ADDITIONAL OPERATOR PROTECTION. PIPE STAND ~ AVAILABLE FROM TEXAS SAMPLING TO PROVIDE CONVENIENT SYSTEM INSTALLATION. ARMORED FLOW METER - ALLOWS FOR VERIFICATION OF PROCESS FLOW THROUGH THE GAS SAMPLE SYSTEM. ‘SAMPLE CYLINDER ASSEMBLY - AVAILABLE FROM TEXAS SAMPLING IN A VARIETY OF SIZES WITH CYLINDER VALVES AND QUICK CONNECTS. DIPTUBE ~ USE AS EXTRA SAFETY PRECAUTION TO ENSURE PROPER OUTAGE. HIGH PRESSURE - HIGH PRESSURE SIGHT GLASS AND EXTENDED SAMPLE VALVE HANDLE FOR APPLICATIONS WITH PRESSURES GREATER THAN 1440 PSIG@100 F BUT LESS THAN 2000 PSIG. LSL-LIQUID 2 CAPTURE SAMPLE 2 ISOLATE SAMPLE 3 VENT SAMPLER FEATURES & BENEFITS Easy Operation + MINIMUM NUMBER OF VALVES (2) REQUIRED TO OPERATE ‘Sight Flow Indleator (Liquid Only) * ALLOWS FOR A VISUAL CHECK OF SAMPLE FLOW * [AND LEVEL OF SAMPLE IN CYLINDER ‘ ‘System Prossure Gauge + PROVIDES INDICATION OF LOOP PRESSURE FOR % VENTING LOOP AND DISCONNECTING CYLINDER + ASSURES PROPER ALIGNMENT, PREVENTS DAMAGE % epider Sesion TO QUICK CONNECTS ee + SAMPLE CYLINDER IS FIRMLY SECURED Chock Valve in + PROVIDES DOUALE BLOCKS ON OPEN CONNECTIONS. Quick Connects OF SAMPLING SYSTEM AFTER SAMPLE CYLINDER 1s REMOVED + PROVIDES VITAL INFORMATION FOR INSTALLATION, Manca OPERATION, AND MAINTENANCE TEXAS SAMPLING INCORPORATED {|} == Anion or CIRODR wvrerxarionat: TEXAS SAMPLING INCORPORATED 4s 3706 EAST RIO GRANDE + VICTORIA, TEXAS 77901 TEL 361.575.8087 © FAX 361.575.8157 E-MAIL sales@texassampling.com www.texassampling.com

You might also like