You are on page 1of 5

SIRIM TRAINING SERVICES SDN BHD - Welding Competency Section

WELDING MACHINE EQUIPMENT CALIBRATION RECORD


EQUIPMENT NO
EQUIPMENT
SERIAL NO
AMPERE RANGE
MAX OCV

:
:
:
:
:

17
WELDING M/C MILLER GOLD STAR 602
LJ 16003BC
~
115

EQUIPMENT POLARITY
CALIBRATION (MASTER) EQUIPMENT
MANUFACTURER
MODEL
CALIBRATION REF
CALIBRATION DUE DATE

:
:
:
:
:
:

VAC
CLAMP METER
JAPAN
KYORITSU AC/DC
SSTS/02/2009D-1100
13/04/2010

MACHINE OCV READING


CLAMP METER OCV READING
RANGE VOLTAGE
ACTUAL VOLTAGE
% VARIATION VOLTAGE

:
:
:
:
:

115
82.8
40.5 ~ 48.9
44.7
28

VOLT
VOLT
VOLT
VOLT
%

AMPERE BEFORE WELDING


SETTING AMPERE
RANGE AMPERE
ACTUAL AMPERE
DIFFERENCE AMPERE
% VARIATION AMPERE

:
:
:
:
:
:

11.8
250
233 ~ 246
239.5
10.5
4.2

AMPS
AMPS
AMPS
AMPS
AMPS
%

:
:
:
:

115

VOLT
AMPS
%
VOLT

VOLT

MACHINE OUTPUT
VOLTAGE
AMPERE
DUTY CYCLE
MAX OCV

CHECKED BY:

APPROVED BY:

DATE:

DATE:

SIRIM TRAINING SERVICES SDN BHD - Welding Competency Section


WELDING MACHINE EQUIPMENT CALIBRATION RECORD
EQUIPMENT NO
EQUIPMENT
SERIAL NO
AMPERE RANGE
MAX OCV

:
:
:
:
:

EQUIPMENT POLARITY
CALIBRATION (MASTER) EQUIPMENT
MANUFACTURER
MODEL
CALIBRATION REF
CALIBRATION DUE DATE

:
:
:
:
:
:

MACHINE OCV READING


CLAMP METER OCV READING
RANGE VOLTAGE
ACTUAL VOLTAGE
% VARIATION VOLTAGE

:
:
:
:
:

AMPERE BEFORE WELDING


SETTING AMPERE
RANGE AMPERE
ACTUAL AMPERE
DIFFERENCE AMPERE
% VARIATION AMPERE

:
:
:
:
:
:

VOLT

VOLT
VOLT
VOLT
VOLT
%
AMPS
AMPS
AMPS
AMPS
AMPS
%

MACHINE OUTPUT
VOLTAGE
AMPERE
DUTY CYCLE
MAX OCV

:
:
:
:

VOLT
AMPS
%
VOLT

CHECKED BY:

APPROVED BY:

DATE:

DATE:

You might also like