You are on page 1of 4
Vacuum Limitamp® 2-High, Medium-Voltage ae bite) Introducing GE's new 2-high Cet et laa TR a Low Voltage Compartments le terminal points Clean, neat white interior are accessible with either panels; easy access and low or medium voltage smple space for numerous doors open. control options jounting surface permits multiple relays and metering packages, including. Multilin, Multilin Draw-out and GE Lodtrak devices. Fullly isolated and inter- locked low/medium volt- age compartments. Matching front and rear a Tneup nih alex EET] ~ Limitamp® controllers (including Air Break) Tough polyester paint — mil baked coating thickness — provides, 1,000-hour sale-spray protection, UL 347 listed, NEMA ICS 2 confo A certified, Front and rear access to horizontal and vertical epoxy bus. Rugged doorindoor design features great Aexibility, safety and high density All new rigid bolted frame provides greater structural strength and flexibility ‘Ventitated and non-ventilated enclosure options Medium Voltage Compartments Large field wiring terminal access with fully Quick make /quick break isolated upper and lower isolation switch: compartments. Visible blade with clear on/off indication Positive over center, independent action Mechanically interlocked with contactor, assuring safe non-load break operation Fastacting, high-interrupt- ing current limiting fuses: DRY EJ or FJ2 ‘*Reliable bolted design with blown fuse indicator and contactor open lockout p fuses optional ‘Full front access and removal (no special tools required) Simple draw-out channels supporting removable contacts featuring line and load stab connections. Industry-proven 400A featuring: ‘*Low maintenance, high reliability ‘*Eayy coll access and simple contact wear check ‘without contactor removal ‘Light weight, fast & easy Wide door opening for easy change-out if required ‘component and wiring + Full interlocking for m safety including up to 10 auxiliary contacts Front accessible control power transformer (2KVA. std., SkVA opt.) including integral fuse holder. Key Product Specifications Main AC Horizontal Bus Ratings Contactor Ratings - CR193B + 12004 or 20008 (19508 nonwentilated) Shorties current (amps) +50 KA rms ym short cixeuit 80 seconds 2400 + Tin or silver plating available 1 second 6000 * Epoxy insulation Impuie withstand (kV) 60 Matching line-up with all existing Limitamps® (including Air Break) Dielectri strength (KV) I minute 13. Switching frequen | | | | | (ops/bour) 1200 Current Ratings (amps) | Mechanical life (ops) 2,000,000, | | | + Vented: 860 top/400 bottom + Non-vented: 320 top/320 bottom eee ee Closing time (max MS) 250 Fuse ratings Opening time (max. MS) Class El mVA_ 25 at 2.5KV ‘mechecal at coll 0 +50. at 5.0kV Pickup voltage (% of rated) 859% max. Class E2 mVA, | 2400 volts Drop out voltage (% of rated) 10%-65% 3600 volts Control voltage (volts) requires ae rectification 110/115 AG 44800 volts Control cireuit burden (VA) Closing Holdin 30 Contactor weight 75 Ibs. (35 kg) Standards applicable References: ‘Technical brochure GET-6840 263 Instruction book GEIL @ GE Electrical Distribution & Control General Elcte Company 41 Woedtord Avenue, Painvile, CT 06062 DET-0644 0495 6SA © 1995 General Etecric Company

You might also like