Connectivity Type
There are three types of connectivity:
1.RNC DDF CWO (SDH) CWO(SDH) - Node B
2.RNC DDF MW A MW B - Node B
3.RNC DDF CWO (SDH) CWO(SDH) -MW A
MW B - Node B
Near End
Far E
E1 E1
The Following test must be:
Near End
Far End
Format to fill
Near End
Site ID NI
ADM Cross
connecting
(Y/N)
Get ADM
E1 DDF
location
(Y/N)
Loop test
from ADM
DDF to RNC
(Y/N)
ADM DDF
SDH DDF
cable
(Y/N)
Far End
Loop test from SDH
DDF to RNC
(Y/N)
Connect cable BW
SDH DDF to MW
(Y/N)
If troubleshooting required you must specify from exchange and from which
point can not receive loop.
STM E1
STM E1
The Following test must be:
Near End
Far End
Format to fill
Near End
Site ID NI
Far End
Loop test from SDH
DDF to RNC
(Y/N)
Connect cable BW
SDH DDF to MW
(Y/N)
If troubleshooting required you must specify from exchange and from which
point can not receive loop.
STM -STM
STM STM
The Following test must be:
Near End
Far End
Format to fill
Near End
Site ID NI
Far End
Physical check for all tie
cable points already
connect
(Y/N)
Get E1 DDF ( Y / N )
Loop test to
Connect cable BW
RNC when get SDH DDF to MW
E1 DDF ( Y / N ) ( Y / N )
Connectivity Type
There are three types of connectivity:
1.BSC DDF CWO (SDH) CWO(SDH) - BTS
2.BSC DDF MW A MW B - BTS
3.BSC DDF CWO (SDH) CWO(SDH) -MW A
MW B - BTS
Tools
1.
2.
3.
4.
5.
6.
Puncher.
Loopback.
Cutter.
Tie cable.
Tape.
Label machine.
Tools
Huawei
Ericsso
n
Siemen
s
Lucent
CWO Equipments
Huawei Optix, Lucent & Siemens.
1.Huawei Optix:
Flr/Bay/Pnl/Blk/Row(Tx-Rx)/Port
01/108.01/03/01/08-07/14
Huawei DDF
2. Lucent :
Flr/Bay/Pnl/Blk/Conn
01/102.03/02/07/26
Lucent DDF
Floor/Cabinet lable/Panel/Block/E1 No.
Floor/Cabinet label
LUCENT DDF
16
Panel Number
Block
1,2,16
E1 Number start from 1,2,364 if use small block each block contain 4 E1
E1 Number start from 1,2,380 if use small block each block contain 10 E1
3. SIEMENS:
Flr/BayLoc/Pnl/Blk/Row/Pin
G/102.01/03.01/09/1-6
Digital Microwave
There are different type of Microwave Equipment:
Huawei
NEC
Ericsson (Mini-Link )
Siemens
Harris
Lucent( P-com)
Nokia (Flexi hopper)
Nera
ERICSSON
Tributary Cables
Ericsson (Mini-link):
ERICSSON MW
There are different capacity (4-8-16-32) E1
- Use Link-Manager Software.
Connect to O&M port in MMU
ERICSSON
1111
ERICSSON
Change the communication port.
ERICSSON
Local Unit
Remote unit
ERICSSON
Local unit must be highlight
ERICSSON
If there is mark that is mean used if not it is free.
To activate, Mark the free one and save
Active
Free
ERICSSON
Physical connection:
-Trace the Tributary cable from MMU
unit( direction to your object site), then check
by led if there is E1 free ( If led give light in
Tx and Rx that mean used but if only give one
light Tx and no light from Rx that is free.
-Connect your cable as cross connection
Tx from your cable to Rx from MW
Rx from your cable to Tx from MW
ERICSSON BLOCK
E1 -1
E1 -2
E1 -3
E1 -4
ERICSSON TN
Traffic node must be defended by STC and
must be Label
TN
HARRIS MW
Harris Mw need to connect to CIT port and using Hyper terminal
Tributary Cable
HARRIS
Start Programs Accessories Hyper
terminal
HARRIS
Configure port setting
HARRIS
Press F1 till you see next
screen
HARRIS
Scroll down by arrow and choose Configuration then press enter the screen no. 2
appear then choose IDU and press enter to go back press F4
F1
(1)
F2
F3
(2)
F4
HARRIS
Scroll down by arrow and choose Tributary then press enter
the screen no. 2 appear then choose which E1 is free ( you can
check physically first) and press enter to go back click F4
F1
F2
F3
F4
F1
F2
F3
F4
HARRIS
To activate E1 press F2 and F3 till you see the value change from Disable to Enable
in actual and new value then press F4 till you reach the first screen after that you
can exit hyper terminal.
Not ready to use
Activated and
ready to use
F1
F2
F3
F4
F1
F2
F3
F4
HARRIS
Physical connection:
-Trace the Tributary cable from MW
unit( direction to your object site), then check
by led if there is E1 free ( If led give light in
Tx and Rx that mean used but if only give one
light Tx and no light from Rx that is free.
-Connect your cable as cross connection
Tx from your cable to Rx from MW
Rx from your cable to Tx from MW
HARRIS BLOCK
E1 -1
E1 -2
E1 -3
E1 -4
P-COM
P-Com MW need to connect to Computer port
and use Link Manger SW.
Tributary cable
P-COM
P-COM
Change the port setting
P-COM
P-COM
To activate E1 mark in enable column then save
Active and
ready to use
P-COM
Physical connection:
-Trace the Tributary cable from MW
unit( direction to your object site), then check
by led if there is E1 free ( If led give light in
Tx and Rx that mean used but if only give one
light Tx and no light from Rx that is free.
-Connect your cable as cross connection
Tx from your cable to Rx from MW
Rx from your cable to Tx from MW
P-COM BLOCK
Always P-com is 4 E1 only ,
You have to trace cable from
MW and check the
connection point from back
E1
E1
E1
SIEMENS
Siemens DDF Ex:
Floor/Cabinet lable/Panel.block/Row/E1
G/102.04/04.01/10/1-6
Row
Each Row contain only 2 E1( 1-6 and 7-12)
1
16
7-12