You are on page 1of 3
TRANS! MISSION CONSTRUCTION STANDARD ATTACHMENT #15 CHECK LIST SIS Name Bay No. 2.8 No: Trip Circuit Supervision 28.1 Trip Circuit Supply Supervision a, General Mechanical Checks & Visual Inspection C. XS) TCS-P-105, Rev. 01 ITEM DESCRIPTION DONE REMARKS, ‘General Visual Inspection “As per 4.1 ‘On Units fitted with hand reset flag indicators, check that the flag is free to fall before, or just, any contacts closes. Make sure that the reset mechanism in the cover is correctly located with respect to the relay element and the flag (or mechanism) can be reset. ‘Check condition of any connectors, contacts alignment and travel ‘Check armature gap. ‘Check for proper operation of LEDs. b. Electrical tests, ITEM DESCRIPTION DONE REMARKS, ‘General Electrical Tests As per 4.2 Measure Trip Supply and Alarm Suppl ‘Check Protective fuse ratin, Ensure correct values of extemal resistors (where applicable) and wired to the correct relay terminals ‘Check the continuity of the contacts, ‘Check the resistance of all output contacts, Check pickup Voltage / Drop —off vollage and measure current, ‘Check power consumption when the relay is energized. Check Relay Coil Resistance. Initiate Alarm by removing fuse. ‘Check Nominal contact voltage AC/DC. ‘Check for visual indication for power supply, pickup and reset 2.82 Trip Circuit Supervision, without pre-closing supervisi a, General Mechanical checks, visual inspection ITEM DESCRIPTION DONE REMARKS General Visual Inspection As per 4.1 ‘On Units fitted with hand reset flag indicators, check that the flag is free to fall before, or just, any contacts closes. Make sure that 2. | the reset mechanism in the cover is correctly located with respect to the relay clement and the flag (or mechanism) can be reset. 3.__[ Check condition of any connectors, contacts alignment and travel 4.__[ Cheek armature gap 5.__[ Check for proper operation of LEDs. TESPIOSROWTMA Dato of Approva uly 08,2011 PREENG OOF TT TRANSMISSION CONSTRUCTION STANDARD ATTACHMENT #15 CHECK LIST I$ Name / No: Bay No. b. Electrical tests C. XS) TCS-P-105, Rev. 01 DESCRIPTION DONE REMARKS, General Electrical Tests ‘AS per 4.2 Check that rating of the relay agree with the Auxiliary Supply to which it is connected, ‘Check that DC Supplies are wired with the correct polarity Measure Trip Supply and Alarm Supply Check Protective fuse rating, Ensure correct values of extemal resistors (where applicable) and wired to the correct relay terminals. Check the continuity of the contacts, Check the resistance of all output contacts Check pickup / Drop —off for both voltage and current of the operating coil ‘Check power consumption when the relay is energized. Check operating Coil Resistance. Check voltage across relay coil when circuit breaker is open and closed. Check voltage across extemal resistors (where applicable) when circuit breaker is open and closed. 14, With the circuit breaker closed apply @ temporary Short circuit across each of the extemal resistors (where applicable) of the trip circuit. Ensure the C.B. does not trip 5, Tnitiate Alarm by removing fuse. 16. voltage ACIDG 17. cation for power supply, pickup and reset 2.8.3 Trip Circuit Supervision, with pre-closing supervision a, Mechanical checks & visual inspection DESCRIPTION DONE REMARKS, General Visual Inspection ‘As per 4.1 ‘On Units fitted with hand reset flag indicators, check that the flag is free to fall before, or just, any contacts closes. Make sure that the reset mechanism in the cover is correctly located with respect to the relay clement and the flag (or mechanism) can be reset. Check condition of any connectors, contacts alignment and travel. ‘Check armature gap. ‘Check for proper operation of LEDs. b, Electrical tests DESCRIPTION DONE REMARKS, General Electrical Tests ‘As per 4.2, Check that rating of the relay agree with the Auxiliary Supply to which itis connected, TESPIOSROWTMA Dato of Approva uly 08,2011 PREENG TH OF TT TRANSMISSION CONSTRUCTION STANDARD C. XS) TCS-P-105, Rev. 01 ATTACHMENT #15 CHECK LIST SIS Name / No: Bay No, TEM DESCRIPTION DONE | REMARKS 3.__| Check that DC Supplies are wired with the correct polarity, 4, [ Measure Trip Supply and Alarm Supply 3.___| Check Protective fuse rating. 6, _ | Ensure correct values of extemal resistors (where applicable) and wired to the correct relay terminals. 7___| Check the continuity of the contacts. 8.__| Check the resistance of all output contacts 9,__| With the C.B. Open Check pickup / Drop -off for both voltage and current of Operating coil-1 10,_ | With the C.B. closed Check pickup / Drop —off for both voltage and current of Operating coil-2. 11. | Check power consumption when the relay is energized. 12.__| Check operating Coil Resistance. 13,_ | Check voltage actoss relay coil when cireuit breaker is open and closed. 14, | Check voltage across extemal resistors (where applicable) when circuit breaker is open and closed. With the circuit breaker closed apply @ temporary Short circuit 15, | actoss each of the external resistors (where applicable) of the trip circuit, Ensure the C.B. does not trip 16, | Initiate Alarm by removing fase. 17._| Check Nominal contact voltage AC/DC. 18. | Check for visual indication for power supply, pickup and reset TESPIOSROWTMA Dato of Approva uly 08,2011 PREENG EOF TT

You might also like