 Technical Information Sheet SD1-40DIN

SURGE DIVERTERS SINGLE PHASE, ALL MODE

DINsafe

Specifications
Description:

Surge diverter - single-phase, threemode.


Nominal voltage: 220 / 230 / 240V AC
Other voltages are available on request.

Pow er Line Surge Protection


Novaris Technologies single-phase surge diverters
provide surge diversion for single-phase power circuits.
The units are designed for mounting at main power
switchboards and distribution boards in category C
locations.
The SD1-xxDIN/3 provides all mode protection.
Protection is provided between active and neutral,
active and earth plus neutral and earth. This means the
SD1-xxDIN/3 can be used at main and distribution
boards in all TN distribution systems including MEN
and TT systems.
If an external alarm funtion is required specify the
SD1-xxDIN/3A.

Surge withstand: IEEE C62.41 cat, A, B, C


AS1768-1991 cat. A, B, C
Surge rating:
40kA, 8/20us pulse response
80kA, 8/20us pulse response
Performance:
<750V clamp for 3KA cat B
<900V clamp for 20KA cat C
Alarms:
Local display showing normal with
power on.
External alarm on overcurrent or
overtemperature. Clean contact
changeover.
Alarm Isolation: 4kV to active circuitry.
Dimensions:
95H x 36W x 80D up to 40kA
95H x 72W x 80D 80kA units
Material:
all metal enclosure.
Mounting:
DIN 35x7.5 rail. Panel mount
brackets available on request.
Terminals:
Active, Neutral, Earth. External alarm
plug in.
2
Max conductor: 16mm
2
Alarm conductor: 2.5mm
Weight:
0.5kG
Location:
Phase-Neutral or Phase-Ground on
MSB or DB.

Performance
MOV TERMINAL VOLTAGE
Volts

1) Ch 1:MOV Volts: 500 Volt 5 us


2) Ch 2: Applied Current: 2 kAmps 5 us

Amps

1000

6000

500

In a systems design these surge diverters would be


utilised upstream of power surge filters for protection
of high sensitivity loads.
O p erat io n
Novaris Technologies single phase all mode surge
diverters comprise 40kA metal oxide varistor elements
and high-energy gas filled arrestors in rugged metal
enclosures with DIN43880 compliant dimensions.
They feature overcurrent fusing and thermal overload
indication. The green LED indicator shows power and
normal. MOV failure due to overcurrent or thermal
overload will extinguish the LED and activate the
external alarm where fitted. Note that in the event of a
thermal overload the MOV is not disconnected from
the circuit and may still provide a level of protection.

4000
2000
Driving Volts = 6000V
0

10

20

30

40

0
us

Typical performance at 6kA, 8/20us

Options
Cat No.
SD1-25DIN/3
SD1-25DIN/3A
SD1-40DIN/3
SD1-40DIN/3A
SD1-80DIN/3
SD1-80DIN/3A

Phases
1 3 mode
1 3 mode
1 - 3 mode
1 - 3 mode
1 3 mode
1 3 mode

Surge
25kA
25kA
40kA
40kA
80kA
80kA

For external alarm connections order /3A version

Novaris Pty Ltd


72 Browns Road, Kingston, TAS. 7050
AUSTRALIA
Copyright 2001 Novaris Technologies
E-mail: sales@novaris.com.au

ABN: 33 065 427 232


TEL: +61 3 6229 7233
FAX: +61 3 6229 9245

Page 1 of 1