You are on page 1of 24

Plan_Checker7v3

By Dayanti Pratiwi

Was developed under:


Windows XP
MapInfo/MapBasic 7

Necessary header/column for bts table:


BTS_NAME
CI
X: Longitude
Y: Latitude
CELL_TYPE: Macro, Micro, Indoor
CELL_SYST: DCS, GSM
NUM_SECT:
#of sector 1 for single cell,
> 1 for quasi antennas

AZM1 to AZM4 (azimuth)


-2 for indoor (small square)
-1 for omni antenna (circle)
If single cell just use AZM1 and
others put 0
NCC
BCC
BCCH
TCH1 to TCH7: put 0 if not use
SIZE (optional): in meter

Necessary header/column for adjacency table (using BTS_NAME format):


SOURCE
TARGET
Company Confidential
1

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Plan_Checker7v3
By Dayanti Pratiwi

No need to create specific directory nor specific table name


Flexibility format data txt/xls/mdb for input table
Capable for Frequency Checker; Handover Checker; BSIC Checker; KPI Checker
Additional menu for neighbor audit
Delete/Create HO, the list of deleted/created relation will be recorded in
tabnameAudit.TAB

Mapping the KPI from different table and create the thematic on the map
Three different style of drawing the btstable for your presentation purposes
Connect the measurement data with related cell using Line Connection

Note: Please exit the tools and run again if you found problem cannot draw the
btstable, this is bugs from MapInfo7, I cannot fix it
Company Confidential
2

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Company Confidential
3

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Clover2 style
The DCS and GSM data
will be split into two
different table

Arrow style

Micro

Indoor

Clover1 style using user defined


from column SIZE value

Clover1 style
The DCS and GSM data
keep maintain in one table

SIZE = 100

Macro GSM
Company Confidential
4

2005 Nokia

Macro DCS

Plan_Checker7v2.ppt / 2005-10-25 / DP

Size = 300

Select the coordinate column with XY; and the projection that you use
Default projection is Longitude/Latitude in decimal degree

Follow the instruction on the dialog

Flexible for any data type (txt/xls/mdb)


The simplest one is txt format, minimize your mistakes if
you forgot to put 0 value when no data
Company Confidential
5

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Quasi omni with 4 antennas direction

indoor

Company Confidential
6

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Put 0 value if you have no data

Necessary columns are


SOURCE & TARGET, the other
columns are your own
additional data

Company Confidential
7

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

You need to open the btstable first before continue


with the checker menus

Company Confidential
8

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Frequency Checker Menus:


Open window frequency checker and then select the
freq that you want to check

Company Confidential
9

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

New freq will be checked

Red = co = ch55
Blue = co + 1 = ch56
Green = co 1 = ch54

Company Confidential
10

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Handover Checker Menus:


Open window HO checker; Open HO table; and then
select the relation that you want to check

Company Confidential
11

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

New HO will be checked

Red = selected bts / SOURCE


Blue = adjacencies bts / TARGET

Company Confidential
12

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Select the bts that you want to add


in your neighbor list; and then
choose menu Create HO

Company Confidential
13

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

After Ctr+j you will see that


the new neighbors were
added

Company Confidential
14

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Select the bts that you want to


delete in your neighbor list; and
then choose menu Delete HO

Company Confidential
15

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

After Ctr+j you will see that


the old neighbors were
deleted

Company Confidential
16

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Your delete/create list result will be


saved in the new tableAudit.TAB in the
same directory with your other data

Company Confidential
17

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

When you delete the adjacency


from the HO list there will be
blank rows in the adce table,
you can Packing the HO Table
to clean up the blank rows after
you finished the neighbor audit

BSIC Checker Menus:


Open window BSIC checker and then select the BSIC or
co BCCH_BSIC that you want to check

Company Confidential
18

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Check BSIC only, if you want


to check co BCCH_BSIC choose
menu

Company Confidential
19

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

KPI Checker Menus:


Open window KPI checker; Open KPI table; and then
select the column kpi that you want to display

Company Confidential
20

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Column from KPI table that you


want to display will be inserted
temporarily into BTS table

If you want to modify the


previous threshold and
redraw the result
Open KPI table
You can use any data and
no need to create specific
table/columns name

Company Confidential
21

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Line Connection Menus:


Open window Line Connection; Open measurement
table (TAB format); and then draw the line connection
between bts vs measurement point using CI as
reference

Company Confidential
22

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

You can use any measurement data (TOM ; TEMS ; etc)


as long as you have CI column with integer type in your
TAB table

The result will be saved in measnameLine.TAB in the


same directory

Company Confidential
23

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

Note: we are using dummy data for the sample

Have a nice day

Company Confidential
24

2005 Nokia

Plan_Checker7v2.ppt / 2005-10-25 / DP

You might also like