DESIGN OF PILE CAP USING USD MENTHOD

NameofPileCap=
PC1
Yieldstrengthofsteelfy
60 ksi
Compressivestrengthofconcretefc'
3 ksi
DiaofPile
20 in
widthofColalongX,b
12 in
HeightofColalongY,h
20 in
UnfactoredLoadonColumn,P
450 kips
ValueofX1
1.5 ft
UltimateLoadonColumn,Pu
675 kips
CriticalWidthofCapforBeamShear(min.)
45 in
AssumedEffectivedepth,d
25 in
XDirectionBottomSteelCalculation
ColfacetoPileface+Piledia/5,a(max)
10 in
CalculatedValueofL
51.96 in
AllowableBeamshearstressVc
410.79 Psi
DepthofPilecapByBeamshear,d
24.34 in
MomentofPileCap,Mu
5400 Kin
Assumevalueof"a"
2.38 in
RequiredAreaofsteelAs
4.20 in2
Check The value of "a"
CheckThevalueof"a"
2 25 in
2.25
UsedRodArea"as"
0.487 in2
MinimumsteelRequiresAs
3.67 in2
SpacingofSteel,Sinbothdirection
5.10 inC/C
YDirectionBottomSteelCalculation
ColfacetoPileface+Piledia/5,a
10 in
AllowableBeamshearstressVc
410.79 Psi
DepthofPilecapByBeamshear,d
24.34 in
MomentofPileCap,Mu
5544.23 Kin
Assumevalueof"a"
2.68 in
RequiredAreaofsteelAs
4.34 in2
CheckThevalueof"a"
2.55 in
2
UsedRodArea"as"
0.487 in
MinimumsteelRequiresAs
3.33 in2
SpacingofSteel,Sinbothdirection
4.49 inC/C
TotalThicknessofPileCap,T
30.00 in
IFTopReinforcemtneisusedthenMinimumsteelforTopReinf.
UsedSteelAreafortopReinf.As
0.31 in2
AstminforXdirection
2.37 in2
AsminforYdirection
2.16 in2

OK

8.62 Nos

OK

8.91 Nos

7.64 Nos
6.95 Nos