€&> OPTEX VIBRO sick sensor INSTALLATION INSTRUCTIONS iNTRODUEHGN: =| es ae i VIBRO is an intelligent Microprocessor controled shock sensor. ‘Test Mode ‘The sensitivity is automatically st in Lear Mode by the level of @ recognised impact made to the protected area. The number of impacts ie. Pulse count required to generate an alarm is determined by the mumber of recognised impacts made in Leama Mode, 1. Remove the sensor ftom its packaging and retain the two serews and grommet, 2. Remove the cover by removing the screw cap, then lunserewing the single captive screw. 3. Carefully elease the printed cireut board from the base 4. Select the intended position for installation, ensuring the surface is clear of any isregularitie 5. Move the base to the mounting positon and mark the desired fixing holes, then by using the wo self tapping screws fx the ‘base (ensure the base isin complete contact with the mounting surfaces and fim. 6 Carefully push the printed circuit board onto the bas 7. Make the electrical connections to the VIBRO as~per connection diagram and details. Make sure no power is applied to the VIBRO while making the connections, 8. Cable entry to the VIBRO can be gained:- @_ Guough die Hole in the base mounting plate, (i) atthe end ofthe cover using single cable knock-out, Gi) using grommet knockout 9. Proceed to TESTAEARN MODE (see under Calibration section) 10, After the unit is calibrated to your satisfaction, select the Tequired Inich mode, replace the cover of the sensor, tighten the fixing screw, (Do not over tighten) replace serew cap and. check its response to the desired impact SURFACE | RADIUS [SURFACE | RADIUS [Concrete sm. Steel 3.0m Brick wall 25m UPVC 225m Breez=block 15m. ‘Wood. 3s * The above ate for guidance only Gross Attack ‘The gross attack festure enables the VIBRO to create an alarm from 4 single impact. This feature bypasses the pulse counting in cases (of gross impact detection. After power up the VIBRO goes through a self tet for 2 seconds. ‘Test result indication by LED are as follows: + Test satisfactory - Several ashes of green light. + Test fail ~ No light or constant Red light or short flashes of Red light. If text fils - check all connections and power. Repeat power up 3 times. IF tet still fails replace the uit Tearn Mode Install the VIBRO according to installation procedure Power up the VIBRO. Wait 2 seconds for self test ‘Choose sensitivity mode (switch 4) before ealbrating, “Make sure the alarm system isin Unset mode Tum ON switch 1 (ear switch) - Red LED wil ght When the Jeam switch is tumed on, the VIBRO will suiomaticaly recognise polaity of Oe laich voltage 7. Wait 2 seconds and stat tpping the aree of coverage for rhamber of pulses required - While red LED is on, 8, Each valid tap will clange LED colour to Green and then retum to Red (the LED should go to Red before the nest pulse count is registered). 9. The sensitivity and pulse count are automatically determined by the number and level of impacts male to the area to be protected a he furthest point from the detector. 10. Ifa Greenlight doesn’t appear, that area iz out of coverage Tange at the impact level entered and the tap was “not counted” - Uy using high sensiviy or install more VIBROs. 11, Bact tap is added to the pulse count, 80 the end, the number of valid taps willbe te pulse count of the uni 12. Alter 15 seconds the Red LED will extinguish and the LED will ash Green confirming the numberof pulse coun 13, [kis recommended thatthe lear switch i not returned to the OFF position until the ed LED goes off, and the number of pulses sot is indicated by the number of Green LED flashes. 14, If you switch off the lear switch before the Red LED goes off, additonal pulses may be enfared (here isa safety feature which deletes the last pulse made i the time that elapses is less tan 2 seconds). 15. tfin the future recalibration is needed and the loam switch has been left in the ON position, switch to OFF for 10 Seconds and then tum lo ON and proceed to setup as nonma 16, To restore default values just move the lear switch to ON for 1S seconds, do not enter any impacts ater 15 seconds, the Red LED will go out andthe number of pulses will be indicated by the green LED flashes [CONNECTIONS 7 Mode Switches 1234 Screw Post Terminal Bock On eo on[Obot|”, © eave Rely LED Tamper Switch ‘Terminals +-12V_12V power connection, reverse polarity protected TAMP N.C. anti-tamper switch, opens when caver is removed. MEM —_Latching connection, Connect to Set/Unset terminal of the alarm system, RELAY N.C. opens when alarm occurs. COM Communications between units. Conneets to all other ‘units inthe same zone. (Used in frst o alarm and ssequecatal latch only) ‘VIBRO sensors have « non-volatile memory and will retain the settings you have made, even if the supply voltage is removed sand subsequently restored. “Multiple VIBRO Connection weno 1 wmo=2 ano (ema wf ae {2 Six to Right wire Connection Six wires: 2 Power, 2 Anti-Tamper, 2 Alarm. Seven wires: Add the above and MEM Sel/Uaset for normal latch ~ also used forall other types of latching. ight wires: All the above and COM used for frst to alarm and. sequential late. Ensure that the supply to the VIBRO is disconnected before connecting the commtnications link, MODE SELECTION, = = a sree Sensitivity Sane 7 Use low sensitivity in « noisy eaviroument - near roads, airports, Tarn mode on Liana < eae = Use high sensitivity ina quiet environment -when you neod & large coverage area Walk Test Use this mode to test the installation. Switch ees ‘A greca light indicates that the VIBRO recognises an impact T Walker | atk ‘A ted light indicates that enough impacts have been received to ‘Normal ata era generate an alarm condition, according the numberof impacts end First to alarm ca | off ‘current calibration ofthe sensors Sequential atch ala With this feature you can test ifthe VIBRO is calibrated to your satisfaction. Sequential ‘After an alarm oecurs in Set mode all connected VIBROs will save SWITCH, a ici order inthe alarm sequence. The first 8 units wil lash the red Low sensitiviiy on LED a numberof times, according other alan sequence nuber High sensitivity off The rest of the units will Mash the green LED according to their number as follows: unit 9 wall ash the greea LED once, unit 10 wall fash the green LED twice, etc. Factory setting ce AILLED alarm indications will clear on sting the alam. [SERGIRIGATION E a = Supply Wotlage v-16v De ‘Alarm Pexod ‘Approx 20s _ ‘Current - Quiescent 165 mA “Tamper Switch TN Open when cover removed: = Alarm 158mA ‘Operating Temparatare Sie Sensitivity ‘Automatic from leara mode impact Environmental Humidity 30% Max ule Count 1 § Programmed in leam mode Dimensions 33x25 x 24am Tadication Two colour LED Max, No, Any latch 128 Latch Modes ‘Any = Furst to alarm = Sequential Max. No. Ist or Sequential 16 ‘Alarm Outpul NC 24VDC 150mA Resistive

You might also like