] i] More Nxt Boge create Blog Sign In FEA-ABODE Common Errors and Warnings in Convergence Problems- Abaqus ERROR: TOO MANY INCREMENTS NEEDED TO COMPLETE THE STEP + Check the message fle for any waming messages, such as numerical singulanty or zero phot warnings, that may be causing slow convergence + ifthere appear tobe no comergence sue, then you may need to increase the lini to the numberof increments for that st20 ERROR: TOO MANY ATTEMPTS MADE FOR THIS INCREMENT -ANALYSIS TERMINATED ‘+ This is just an ero message which eves reason for why Abaqus fray aborted + owl motiy the soir conta to increase the numberof alowabte attempts pet increment + Check the message fils fr waming messages that could cause comergence difculties + Check the mode! defiaton, ard make sure thatthe model ean actualy withstand the applied loads ERROR: TIME INCREMENT REQUIRED IS LESS THAN MINIMUM SPECIFIED-ANALYSIS ENDS + Again, this is just an ore message which ghes reason for why Abacus fray aborts itis nota suggestion by Abaqus fo reduce the minimum allowable inrement size + Check the message fle fr waming messages that could cause convergence dfculties + Check the model defnton, ans make sur thatthe model can actualy withstand the ‘applied loads WARNING: THE STRAIN INCREMENT HAS EXCEEDED FIFTY TIMES THE STRAIN TO CAUSE FIRST YIELD AT 500 POINTS + Indicates excessive plastic ying in the gen increment + Possible causes would be Excessive or unrealistic leading inconsistent units. for example) Iheonect o insulcentstess-tran plastic data sullen mesh homent Unstate deformation, such as buckling NOTE: Ths ctor iy’ mentioned in the waming message cannot be madifed WARNING: ELEMENT 441 IS DISTORTING SO MUCH THAT FT TURNS INSIDE OUT + Possible causes woula be: Inecficient mesh refinement HHourglassing in first-order radeced integration elements Inconsistent unis for material properties andor loads Excessive or unrealistic loads Adjusting slave nodes of seweraly overclosed surfaces for contact pais or ie (rit overetogures) WARNING: THE SYSTEM MATRIX HAS. 9 NEGATIVE EIGENVALUES + Possible causes would bo: Some form ofloss of stitness suggesting that the st hess matrixis assembled about o non-aqulbum stat: CGeomotricl instability: bucKling, compression Material nstabity: inappropriate hyperslastic material models, onset of perfect plastcty Loc ARCHIVE yon we vayea) ¥ rl(83) CCoqwnon ors wd Waring ‘Convergence Probloms. Hetping Abaqus Find 2 Comarged ‘itor Reasons for outback load increment ofa conver. Causes ofconvergence problems Symptoms of convergence problems In ‘bags Why Abague Fale Find a Converged 'otutonin Meshing Methods in FEA FEASolver background ofhodal FEASolver background afLinear state anahsis, Wen ogo fora state anahsis Elomeonts slecton niferent riimum numberof ave Bough lements shouts wate nowglsang i atrder sot \Whatis sheer locking toner ga ‘loments Hom acvale Large Stain Etoctn ‘Shave anal ‘Small Sin Vs Lage Stein Whatis the citerencebotwe shall Hom ong te poste normal of \Wnatunts ate used in ABAQUS? ‘Anatals Guldsines for beginners Propet ofstness matic Imporanes efstness matix Whatis st ness and whydo we need it [Numerical the use of Lagrange multipin in certain cases may also leas to these waming messages Use of secondtonder elements as contac slne) surlaces + Typically, these waming messages donot appear in converged trations Irthey co, ensue that the solution physically acceptable WARNING: SOLVER PROBLEM, NUMERICAL SIGULARITY WHEN PROCESSING NODE 1 DOF. 3 RATION. 141E+15 + Typical suggests an unconstained rigid body motion + Even ifthe analysis runs to completion with those warnings, the results may not be WARNING: SOLVER PROBLEM, ZERO PIVOT WHEN PROCESSING NODE 1 0.0.F.1 + Typlally suggests an oreronstraint + Even ifthe analysis rns completion wth these wamings, the results wil nat be 1 comment: o Duty Velynkin 6 December 2012 20:10 callnt post sory help he been geting the second enor above ERROR: TOO MANY [ATTEMPTS MADE FOR THIS INCREMENT ~ANA.YSIS TERMINATED" he seems that before mi, the automatic hetement sia increases to gute high values ana ‘baqus cares on dospto many sowro discontinuity itratons. But then it sooms fo wart © 1e decease slop siz tothe minimum pected, atough did need Ya use te minimum at mes. ltran outafllowabe atoms perinerement Lis lmy bahuviourto me for Absqus ts Sometimes incense increment sans 6 vy ea Reply ‘comment as: [Googe Account (Pretew | ‘Subscibe to: Post Comments (om) ‘Simple tomplat,Poweres bylogaer Liar Ve Non linear Difference betueen Kinemate coustng Im Abegus Why ooarser mech fordynamic anahsie Hm Ve Tota Elements Wats FEA? Why FEA? Wnt do you etiam FER? ABUT ME FEA\s gong popular day mechanalenginrs Enhusiastic ongnoors ana baginnors who ‘want oesh or update te knoledge on ‘heretical eoncopsswnieh are too mathematical The main enon of is Blog ininaustywin engineers who are passionate fo develop a fea of FEAWhin ls ‘8sontal fr one tobe reallycompotant Vow mycomplats pros

You might also like