You are on page 1of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

STREETLIGHT PHOTOMETRIC TEST REPORT


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

TEST DATA:
MODEL:

Imax(cd):
ALULED-90W-354

8460

street_up(%):

0.0

NOMINAL POWER(W):

108

MAXIMUM @(C, ):

90,60.0

street_down(%):

52.7

RATED VOLTAGE(V):

130

TOTAL FLUX(lm):

14389

house_up(%)

0.0

NOMINAL FLUX(lm):

14220.0

EFFICIENCY(%):

101.2

house_down(%):

48.5

TEST FLUX(lm:

14220

up(%):

0.0

LAMPS QUANTITY:

down(%):

101.2

INTENSITY DISTRIBUTION DIAGRAM


IN C PLANS

INTENSITY DISTRIBUTION DIAGRAM


IN C PLANS
LUMINOUS INTENSITY DISTRIBUTION
8460

-150

8460

150

6768
6768

5076

-120

C0/180
C30/210
C60/240
C90/270

120

1692
0

-90

90

-60

INTENSITY(cd)

3384
5076

3384

60

-30

30
0

UNIT:cd
C0/180
C30/210
C60/240
C90/270

1692

0
-90

-60

-30
0
ANGLE(DEG)

30

60

Test:U:130.0V I:0.842A P:108.4W PF:0.989


Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 1 Of 11

90

GONIOPHOTOMETERS SYSTEM TEST REPORT

ZONAL FLUX DIAGRAM


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
DEG

C0
6904
6418
5735
4904
4085
3420
2332
1218
966.0
892.1
856.3
841.0
522.7
204.4
103.8
32.56
3.013
1.847

C45
6372
5555
4904
4666
4483
4380
4224
3750
2703
1520
794.5
493.7
288.8
197.7
132.2
64.90
20.93
2.624

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

C90
6254
5222
5280
5338
5918
6499
6560
6621
7045
7468
7964
8460
7880
7300
3753
206.4
106.9
7.485

C135
6587
5723
4955
4812
4717
4665
4458
3988
3286
2148
1145
606.6
300.9
213.7
119.3
63.95
27.07
3.013

C180
7355
6977
6284
5391
4450
3708
2975
1516
974.3
880.2
836.5
822.7
556.7
205.0
126.6
53.08
10.88
3.499

C225
6575
5709
4944
4736
4614
4535
4313
3863
3232
2234
1266
660.2
313.0
223.6
137.5
80.30
36.65
2.916

C270
6238
5189
5198
5207
5537
5866
5995
6123
6541
6958
7459
7961
7676
7391
3888
384.1
196.1
8.263

C315
6360
5540
4891
4607
4413
4310
4197
3851
2986
1773
905.8
538.9
316.4
224.7
156.9
83.03
30.78
2.624

0- 5
5- 10
10- 15
15- 20
20- 25
25- 30
30- 35
35- 40
40- 45
45- 50
50- 55
55- 60
60- 65
65- 70
70- 75
75- 80
80- 85
85- 90
90- 95
95-100
100-105
105-110
110-115
115-120
120-125
125-130
130-135
135-140
140-145
145-150
150-155
155-160
160-165
165-170
170-175
175-180

zone

162.4
436.5
645.9
831.0
1003
1173
1310
1349
1299
1254
1208
1139
1004
786.6
520.6
214.7
39.80
12.96

LUMINOUS INTENSITY:cd

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 2 Of 11

total

162.4
598.9
1245
2076
3079
4252
5562
6911
8210
9464
10672
11811
12815
13601
14122
14337
14376
14389

UNIT:lm

GONIOPHOTOMETERS SYSTEM TEST REPORT

ISOCANDELA DIAGRAM
Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
90

10%

75

20%

60

30%
40%

45
VERTICAL(DEG)

50%
30

60%

15

70%

80%

-15

90%

-30
-45
-60
-75
-90
-90 -75 -60 -45 -30 -15

15

30

45

60

75

90

HORIZONTAL(DEG)

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 3 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

ISOLUX DIAGRAM
Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

ILLUMINANCE AT MH=10 m,Enadir

= 72.86 lx

STREET SIDE

D/MH

HOUSE SIDE

4-7

-6

-5

-4

-3

-2

-1

RATIO OF DISTANCE TO MOUNTING HEIGHT


0.360
22

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

0.730
29

2.2
36

3.6
44

7.3
58

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 4 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

ISOCANDELA DIAGRAM
Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

180

170

160
150
140
130
UNIT:cd
120
110
100

270

300

330

C0

30

60

90
90
80
70
60

5%

423

10%

846

20%

1692

30%

2538

40%

3384

50%

4230

60%

5076

70%

5922

80%

6768

90%

7614

Imax=100%

8460

50
40
30
0

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

10

20

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 5 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

ISOCANDELA DIAGRAM
Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

C195

C180

C210

HOUSE SIDE

C165
C150

C225

C135

C240

C120

C255

C105
0

C270

C90

1700
C285

C75

3400

C300

6800

C315
C330

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

C60

5100

C30
8500
C345
C15
C0
Max @ = 60.0DEG

C45

STREET SIDE

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 6 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

LUMINOUS DISTRIBUTION INTENSITY DATA


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
C(DEG)
(DEG)

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0

10

15

20

25

30

35

40

45

50

55

60

65

70

7286
6904
6418
5735
4904
4085
3420
2332
1218
966
892
856
841
523
204
104
32.5
3.01
1.84

7286
6830
6292
5585
4796
4069
3495
2472
1303
977
884
842
826
595
234
107
46.1
8.52
2.23

7286
6759
6174
5449
4707
4071
3587
2670
1486
1023
873
796
647
363
207
121
42.7
6.96
2.23

7286
6692
6062
5326
4628
4078
3682
2894
1658
1018
836
743
590
397
193
109
47.3
10.5
2.23

7286
6629
5959
5215
4552
4076
3739
2950
1783
1007
809
724
578
339
183
124
48.2
12.1
2.33

7286
6569
5863
5114
4474
4106
3794
3124
1913
1050
828
698
507
304
196
109
53.8
11.3
2.33

7286
6513
5774
5023
4420
4183
3904
3392
2272
1385
865
621
454
302
189
105
58.1
9.33
2.43

7286
6461
5693
4940
4493
4274
4035
3601
2793
1747
940
574
414
277
181
108
54.0
12.4
2.43

7286
6414
5620
4865
4572
4375
4170
3907
3349
2192
1097
615
396
274
176
115
57.2
16.3
2.52

7286
6372
5555
4904
4666
4483
4380
4224
3750
2703
1520
795
494
289
198
132
64.9
20.9
2.62

7286
6334
5499
4967
4763
4597
4587
4533
4102
3218
2212
1410
775
360
240
160
76.1
26.7
2.81

7286
6302
5451
5018
4860
4742
4767
4833
4412
3801
3039
2206
1349
773
389
189
87.7
33.0
3.11

7286
6276
5413
5074
4955
4890
4936
4954
4725
4334
3815
3081
1996
1185
595
247
104
42.3
3.59

7286
6255
5355
5132
5036
5033
5098
5117
5002
4815
4578
3898
2772
1797
979
446
129
46.1
4.18

7286
6241
5306
5194
5120
5208
5261
5310
5298
5302
5269
4656
3718
2691
1719
879
159
43.9
5.05

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 7 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

LUMINOUS DISTRIBUTION INTENSITY DATA


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
C(DEG)
(DEG)

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0

75

80

85

90

95

100

105

110

115

120

125

130

135

140

145

7286
6233
5266
5216
5208
5403
5565
5591
5617
5783
5929
5535
4919
3838
2713
1395
167
48.3
5.83

7286
6233
5238
5237
5252
5592
5884
5930
5975
6308
6632
6536
6340
5334
4248
2177
162
54.6
6.70

7286
6240
5223
5259
5295
5759
6195
6250
6307
6751
7216
7476
7709
7010
6291
3249
201
92.8
7.29

7286
6254
5222
5280
5338
5918
6499
6560
6621
7045
7468
7964
8460
7880
7300
3753
206
107
7.48

7286
6261
5230
5277
5331
5793
6220
6341
6482
6896
7318
7785
8252
7042
5753
2981
230
109
7.38

7286
6276
5253
5273
5324
5660
5936
6096
6263
6571
6866
7071
7223
5804
4255
2191
178
62.4
6.90

7286
6298
5292
5269
5312
5507
5664
5794
5948
6134
6265
6140
5858
4395
2727
1367
180
56.9
6.12

7286
6328
5347
5260
5242
5348
5406
5543
5673
5719
5647
5183
4502
3209
1792
877
174
53.1
5.34

7286
6366
5418
5201
5171
5205
5272
5364
5411
5291
4931
4254
3333
2224
1006
373
131
55.6
4.56

7286
6411
5503
5142
5098
5087
5139
5205
5153
4896
4216
3358
2346
1381
572
214
120
57.9
3.98

7286
6463
5564
5082
5006
4963
5000
5080
4810
4418
3530
2365
1319
675
352
175
98.5
44.5
3.49

7286
6522
5637
5023
4910
4836
4849
4772
4404
3828
2874
1693
951
422
249
145
79.6
34.0
3.20

7286
6587
5723
4955
4812
4717
4665
4458
3988
3286
2148
1145
607
301
214
119
63.9
27.0
3.01

7286
6657
5822
4928
4713
4600
4480
4187
3628
2527
1411
733
372
262
187
108
53.9
20.4
3.01

7286
6733
5933
5063
4622
4483
4333
3951
3169
1926
996
603
405
246
179
108
47.6
16.5
2.91

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 8 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

LUMINOUS DISTRIBUTION INTENSITY DATA


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
C(DEG)
(DEG)

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0

150

155

160

165

170

175

180

185

190

195

200

205

210

215

220

7286
6814
6054
5207
4533
4367
4166
3771
2860
1571
810
606
465
283
174
111
52.1
12.5
2.91

7286
6898
6186
5359
4638
4259
3994
3487
2628
1148
804
654
493
321
173
111
60.7
15.0
2.91

7286
6986
6328
5521
4782
4236
3857
3237
2127
1085
795
678
487
309
186
107
63.0
11.9
2.81

7286
7076
6478
5693
4922
4292
3786
3038
1738
1005
810
728
569
311
180
112
54.6
7.56
2.91

7286
7168
6637
5876
5065
4336
3746
2954
1507
960
827
773
642
414
191
98.8
48.3
10.9
2.81

7286
7261
6804
6073
5218
4383
3716
2937
1453
957
850
813
630
380
185
109
41.4
10.0
2.52

7286
7355
6977
6284
5391
4450
3708
2975
1516
974
880
837
823
557
205
127
53.0
10.8
3.49

7286
7260
6804
6068
5216
4384
3711
2934
1458
962
862
822
644
403
194
113
43.9
12.3
1.74

7286
7165
6637
5868
5059
4337
3738
2948
1514
971
847
798
690
476
208
106
54.9
14.5
1.65

7286
7071
6478
5681
4913
4292
3776
3029
1751
1023
831
768
622
355
191
121
61.5
11.3
1.84

7286
6980
6327
5507
4769
4233
3842
3226
2146
1120
815
726
541
343
198
117
71.6
17.0
1.94

7286
6891
6184
5345
4619
4243
3964
3465
2649
1191
831
702
550
367
192
125
70.2
20.2
2.04

7286
6805
6050
5193
4506
4331
4115
3729
2868
1609
840
655
522
320
195
128
60.4
18.2
2.13

7286
6723
5926
5051
4576
4428
4257
3880
3139
1982
1049
657
455
279
199
125
60.8
22.8
2.33

7286
6646
5812
4920
4647
4522
4382
4082
3540
2545
1534
803
408
290
204
126
68.5
29.1
2.62

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 9 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

LUMINOUS DISTRIBUTION INTENSITY DATA


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
C(DEG)
(DEG)

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0

225

230

235

240

245

250

255

260

265

270

275

280

285

290

295

7286
6575
5709
4944
4736
4614
4535
4313
3863
3232
2234
1266
660
313
224
138
80.3
36.6
2.91

7286
6509
5618
5001
4826
4705
4681
4571
4243
3729
2880
1803
1054
462
270
165
100
47.3
3.30

7286
6449
5540
5046
4913
4811
4796
4822
4599
4262
3462
2428
1537
891
431
201
129
63.7
3.69

7286
6396
5473
5094
4997
4926
4911
4931
4899
4686
4067
3331
2601
1760
849
338
167
80.3
4.18

7286
6351
5386
5145
5067
5042
5049
5078
5114
5010
4686
4184
3569
2630
1486
736
233
83.3
4.37

7286
6313
5315
5198
5140
5161
5188
5251
5327
5352
5272
5016
4646
3529
2168
1117
256
86.1
5.05

7286
6282
5259
5201
5215
5284
5353
5453
5544
5677
5772
5810
5775
4636
3263
1736
306
112
5.63

7286
6259
5220
5201
5216
5389
5520
5680
5834
6079
6309
6584
6835
5873
4764
2537
345
144
6.22

7286
6244
5196
5199
5212
5464
5694
5852
6023
6390
6757
7234
7715
7165
6577
3497
403
194
7.19

7286
6238
5189
5198
5207
5537
5866
5995
6123
6541
6958
7459
7961
7676
7391
3888
384
196
8.26

7286
6223
5190
5183
5180
5436
5672
5792
5916
6335
6767
7141
7503
7081
6638
3510
363
174
7.68

7286
6217
5205
5168
5153
5330
5475
5575
5664
5977
6281
6386
6427
5631
4734
2501
294
118
6.31

7286
6217
5234
5154
5124
5198
5281
5330
5363
5535
5695
5562
5296
4318
3190
1692
260
88.5
5.34

7286
6225
5274
5138
5034
5049
5087
5122
5129
5166
5159
4809
4223
3210
2089
1085
214
63.5
4.66

7286
6240
5324
5082
4950
4905
4941
4957
4903
4790
4616
4117
3222
2224
1239
589
186
69.9
4.08

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 10 Of 11

GONIOPHOTOMETERS SYSTEM TEST REPORT

LUMINOUS DISTRIBUTION INTENSITY DATA


Report number: ALUTLED-0112
MANUFACTURER: ALUTRAFIC LED

Address:AV. CIRCUNVALAR - VIA 40 LAS FLORES

NAME: ALULED-90W-354

TYPE:ALUMB. PUB.

WEIGHT:

SPECIFICATION:90 LEDs

DIMENSION: 32x76x12 cm

SERIAL No.:

UNIT: cd
C(DEG)
(DEG)

0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0

300

305

310

315

320

325

330

335

340

345

350

355

7286
6261
5383
5031
4873
4773
4792
4809
4675
4418
3994
3355
2329
1468
744
314
146
64.2
3.49

7286
6288
5427
4985
4787
4638
4644
4691
4419
4009
3328
2486
1591
926
458
226
116
47.7
3.01

7286
6321
5479
4946
4698
4510
4488
4451
4166
3472
2548
1633
879
391
269
189
97.7
38.4
2.72

7286
6360
5540
4891
4607
4413
4310
4197
3851
2986
1773
906
539
316
225
157
83.0
30.7
2.62

7286
6403
5609
4854
4519
4321
4121
3921
3505
2430
1264
689
430
307
200
137
73.4
24.5
2.33

7286
6452
5685
4925
4451
4233
3999
3650
2964
1995
1041
629
456
319
208
127
67.8
19.0
2.23

7286
6504
5769
5006
4388
4152
3887
3458
2445
1523
923
662
499
347
213
121
69.2
15.2
2.13

7286
6562
5859
5097
4449
4085
3791
3188
2057
1111
863
727
552
373
219
126
71.8
17.9
1.94

7286
6623
5957
5200
4533
4063
3735
2995
1860
1044
821
736
613
390
201
137
61.6
17.3
1.94

7286
6688
6061
5313
4614
4070
3675
2906
1693
1040
842
758
634
464
212
122
59.4
14.5
1.94

7286
6756
6173
5440
4697
4066
3582
2678
1502
1040
884
812
678
414
230
132
54.3
9.76
1.84

7286
6828
6292
5580
4791
4067
3492
2477
1311
986
891
848
833
635
246
112
55.4
11.7
1.74

Test System:LSG-1800
Temperature:25.3DEG
Operators:
Test Date:02-19-2013

Test Set: 5.0deg/s B-Beta (TYPE B)


Humidity:65.0%
Test Distance:9.860 m
Remarks: DRIVER CLG-150-24A
Page 11 Of 11

You might also like