You are on page 1of 5
Muay Ua (aed a ta: ae ta FEATURES: '™ Gas bleed system standard in all models. = An additional test arm provided to check operation of switch. Specially coated stainless steel operating disc with deep drawn spring locater. 'm Pressure die cast, vaccum impregnated and pure polyster powder coated mounting flange. Ail stainless steel hardware. Springs made out of oil hardened and tempered spring steel wire to provide uniform loading and to prevent fatigue failure. '™ Spring specially treated and coated to prevent rust and corrosion due to harsh environment. 'm Inner and outer springs reverse wound and paired for consistent operating pressure. INSTRUMENTS. oT305R0 CONSTRUCTION The Pressure Relief Device consists of pressure die cast Aluminium flange (1) with gasket (2) for mounting on transformer. The operating disc (3) is loaded with two reverse wound calibrated springs (4) and seals the 150 mm port against the top and side gasket (5 & 6), The deep drawn cover (7) retains and compresses the spring and is held in place by six screws (8). The cover and the operating disc has specially designed retainers to prevent the dislocation of springs during repeated operations, The switch assembly (9) is optional and inoludes a single pole, double throw switch. Ithas a three conductor cable for connection to an alarm or signal device. The switch is activated by the upward movement of disc and has to be manually reset using the arm (10). The operation af the switch can be tested using the test arm (13). An optional long armed coloured flag (11) type arrangement can be provided for visual indication from greater distances. Gas bleed system (12) is provided on all models as standard. WORKING When pressure in the tank rises, the total force on the area defined by the top gasket on the operating disc also increases. As soon as this force exceeds the load applied by the springs, the operating disc moves slightly upwards. This exposes the ‘transformer pressure to a greater area corresponding to the diameter of side gasket, resulting in sudden increase of force. The isk lifts instantaneously and vents aut the excess pressure in the transformer. When the pressure falls to allowable values, the spring forces the disc back to its original position, APPLICATION These Pressure Relief Devices are recommended to be used on all sizes of transformers ranging from distribution transformers to large power transformers. For very large power transformers, it is usual to use ‘multiple devices. Normally one device is used for every 10,000 gallons (35000 ires approx) of cooling liquid. MOUNTING & MAINTENANCE These Pressure Relief devices should be preferably mounted in the horizontal position, top side up. The device has rugged construction and does not require maintenance. The operating pressure Is factory preset and cannot be changed at site. It is strongly recommended that the compression screws on the cover be never removed without use of extreme caution. EQUALLY SPACED LUGS GNSH a5) RCD. 8 Je — movcator Fa SL eereny g| se 3] | ve (2 cc y TESTARM DIMENSIONS IN BRACKETS ARE MA VALVE SPECIFICATIONS WIRING DIAGRAM 1, Number of Switch - One. ee 2. Operation ~ Automatic KT 3. Number of Contacts - 1NO+1NC on 4, Switch resetting ~ Manual e 5. Contact rating ~ 15 Amps. @ 125, 250 coREEN and 480 V AC. {RING DIAGRAM (STANDARD) 0.5 Amps @ 125 VDC LACK (non inductive) 1 6. Switch operation fl ° Te a) Before device operation - Contact 1 NC 2X0 beni Contact 2 NO 22 oe ft b) After device operates - Contact 1 opens auue Contact 2 closes WIRING DIAGRAM (ANS), ORDERING INFORMATION VTE Ra aL) ea asa ley Operating pressure in PSI Alarm Switch Connector 5/8/10/12 YES / NO Standard with 1-4-6 terminals and Black-White-Green Wiring. OR ANSI with 1-2-3 terminals and Black-Red-Blue Wiring. YES/NO ‘Standard - Nitrile (NBR) Optional - Fluorocarbon (Viton) Standard - 48" Non standard - As required. All devices are supplied with one NBR rubber mounting gasket. ABOUT US ‘As @ team of engineers we have been directly involved in designing and manufacturing accessories for the ‘transformer industry for 30 years. Consistency in quality, delivery and service has brought us approvals from leading ‘transformer manufacturers worldwide. We manufacture the widest range of pressure relief valves and devices exclusively for transformer industry in the following sizes. 4) 1," and 1," NPT thread type with & without indicator Long armed Yellow Semaphore Gaskets Cable length in inches FOR MODEL NUMBER AND ORDERING CONTACT Atul Gupta Director-Marketing oF 2) G1” and G2" thread type to ISO 228 w 3) 2” (50mm) and 3" (80mm) flange type with and Vinay Gupta without switch & protective cover Director-Manufacturing 4) 6" (150mm) flange type with and without switch & long arm indicator Due to our policy of continuous product improvement, cimensions and designs ae subject to chang. V INSTRUMENTS VIAT INSTRUMENTS PVT. LTD. 689, Block ‘0’, New Alipore, Caleutta - 700 053, INDIA Phones : (91-33) 4001101, 4009885 « Fax : (91-33) 4007443, 4007043, E-mail : agupta@giasci01.vsnl.net in « viatin@viatin.com ¢ Website : www.viatin.com 6 EQUALLY SPACED LUGS ON 9 1/4"(235) PC. Sey WIRING DIAGRAM BLACK (NORMAL CONDITION; 10 1/8"(258) BLACK 10 1/4°(261) (WHEN ALARM OPERATES, sumon_ nazi : 16 AMPS O128, 260, 40 VOLTS 4 bss aus © 125 TOTS DC.) on ous ane 0 Pats bo } nau INDICATOR SwTCH 5 1/4"(133) TEST LEVER (RED). PULL OUTWARD To CHECK (OPERATION OF CONTACTS, RESET LEVER, AFTER OPERATION BLEED SCREW WITH ‘0’ RING SEAL PUSH INWARD TO_RESET CONTACTS. ‘MODEL | OPERATING : panei | OPERATING | casxer | inpicator | GENERAL INFORMATION : Psr_| Bar 1, BLBBD SCREW : IS A STANDARD FEATURE IN ALL MODELS. sososo2-2 | 521 |0.95 40.07 2. ADDITIONAL TEST LEVER : PROVIDED TO CHECK OPERATION s0soso2-2 | ax1 |0.56+0.07| wpe | ypizow OF CONTACTS IN ALL MODELS WITH SWITCH. 30510022 | 1041 | 0.70 £0.07 3. HINISH : LIGHT GREY ASA 70 PORDER COATED. 3051202-2 | 1241 | 0.84 £0.07 4. CONNECTOR : IS OPTIONAL AND TO BE ORDERED SEPERATELY FOR CONNECTOR WITH/WITHOUT CABLE REP. DRC. 600.1 SBRIBS 5. SEMAPHORE : PART NO. 601 IS OPTIONAL AND 0 BE ORDERED SEPERATELY. 6. CABLE : NOT SUPPLIED 7. GASKET : NBR (NITRILE) FOR TRANSFORMER OIL. VITON FOR SILICON Olt VIAT INSTRUMENTS PVT. LTD. CALCUTTA— 700 059, INDIA CLIBNT + prw. | #. cut | Tiree : ‘APPD. | A. GUPTA ‘Dare | 29.10.07 PRESSURE RELIEF DEVICE 305 SERIES MITH TWO STANDERD ALARM SWITCH,WITHOUT CONNECTOI ‘scaue | W.7.S. | DIMENSIONS 4RE IN INCHES (MU) AND FOR REFERENCE ONLY wo.| pare | _pesc._[aPro.|| -— ; , REVISION SH TESons E=3 -@-| pre. wo. : 305.8 |e" 0 Et

You might also like