Tech Sheet #ST 104 Small Drip Legs Cause Big Problems Correct Sizing Eliminates Water Hammer, Pipe Erosion, and Long Startup Times
Tech Sheet #ST 104 Small Drip Legs Cause Big Problems Correct Sizing Eliminates Water Hammer, Pipe Erosion, and Long Startup Times
Fig. 1 Condensate
collects in low areas
that are created by the
sagging of poorly
supported piping.
This Tech Sheet was developed by the members of the Fluid Controls Institute (FCI) Steam Trap Section. FCI is a trade association comprising the
leading manufacturers of fluid control and conditioning equipment. FCI Tech Sheets are information tools and should not be used as substitutes for
instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment.
10/27/05
Page 1 of 5
This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.
This Tech Sheet was developed by the members of the Fluid Controls Institute (FCI) Steam Trap Section. FCI is a trade association comprising the
leading manufacturers of fluid control and conditioning equipment. FCI Tech Sheets are information tools and should not be used as substitutes for
instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment.
10/27/05
Page 2 of 5
This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.
This Tech Sheet was developed by the members of the Fluid Controls Institute (FCI) Steam Trap Section. FCI is a trade association comprising the
leading manufacturers of fluid control and conditioning equipment. FCI Tech Sheets are information tools and should not be used as substitutes for
instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment.
10/27/05
Page 3 of 5
This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.
M
Steam Main
Size, in.
1
2
3
4
6
8
10
12
14
16
18
20
24
10
28
10
28
1
10
28
2
10
28
3
10
28
4
10
28
4
10
28
4
12
28
6
15
28
6
18
28
8
21
28
8
24
28
10
27
28
10
30
30
12
36
36
This Tech Sheet was developed by the members of the Fluid Controls Institute (FCI) Steam Trap Section. FCI is a trade association comprising the
leading manufacturers of fluid control and conditioning equipment. FCI Tech Sheets are information tools and should not be used as substitutes for
instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment.
10/27/05
Page 4 of 5
This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.
This Tech Sheet was developed by the members of the Fluid Controls Institute (FCI) Steam Trap Section. FCI is a trade association comprising the
leading manufacturers of fluid control and conditioning equipment. FCI Tech Sheets are information tools and should not be used as substitutes for
instructions from individual manufacturers. Always consult with individual manufacturers for specific instructions regarding their equipment.
10/27/05
Page 5 of 5
This sheet is reviewed periodically and may be updated. Visit www.fluidcontrolsinstitute.org for the latest version.