You are on page 1of 37

OMT Operation & Maintenance Terminal

(CXP 104 0015/6)


OMT Version: P49H

1 Release Notes

P49H(CXP 104 0015/6)

1.1 New functions


Configurable Antenna System Voltage
AIR as one unit

1.1.1 Modified functions


Create IDB: Support Antenna System Voltage in Create IDB
Install IDB: Display information when Antenna System Voltage 12V
or 17V TMA is defined in IDB
Display RU Information: For the chosen RE Display Antenna
System Voltage
Define ALNA_TMA Parameters: Support for Antenna System
Voltage

1.1.2 New views


1.1.1 Modified views
AIR as one unit

1.1.3 New configurations


Configurable Antenna System Voltage: New system device type and
voltage

1.1.4 New monitors


1.1.5 R48S(CXP 104 0015/5)
1.1.6 New functions
Battery test
Support for DUG20 R3A and on
Function "Load Flash Card" loads complete SW also for DUG 20 R3A and on.
Older OMT loads incomplete SW, and additional SW download from BSC
therefore takes place

Support System upgrade

1.1.7 Modified functions


Basic mixed mode enhancements

1.1.8 New views


1.1.9 Modified views
1.1.10 New configurations
Support for RRUS 12 (Dual TX):
Single mode: Added RBB 22 1b, RBB 42 2d and RBB 44 2c
Mixed mode: Added RBB 22 2c and RBB 42 4a

Support for AIR 11(shown as RRUS 01 in OMT):


Using configurations with RBB 11 1a/RBB 11 1b and new RBB 22 2g

Support for AIR 21(shown as RRUS 01 in OMT):


Using configurations with RBB 12 1a/RBB 12 1b and new RBB 24 2c

Support for RBS 6101 and RBS 6102 as Main Unit.


The RBS is equipped with RRUS only. Refer to HW documentation for
more information.

Support for RBS 6101, RBS 6102, RBS 6201 and RBS 6202 as
Hybrid
The RBS is equipped with RUS and RRUS. Refer to HW
documentation for more information.

1.1.11 New monitors


BFU Battery Fault LED
VSWR at TX Antenna with port B
TMA current at port B
Battery Test Running
Battery Test Status

R47B (CXP 104 0015/4)

1.1.2 New functions


Display Combined Cell Configuration

1.1.3 Modified functions


Create IDB: Added choice for Internal Cascaded RBB

1.1.4 New views


-

1.1.5 Modified views


-

1.1.6 New configurations


Support for RRUS Cascading

1.1.7 New monitors


R45M (CXP 104 0015/2)

1.1.12 New function


Clear Technician Present

1.1.13 Modified function


Change Maintenance Mode

1.1.14 New configurations


Support for RUS02 (Up to 8 TRXs)
Support for AIR (Requires BTS SW G12B or later)

1.1.15 New monitors


Fault Status Monitor for MCTR (Multi Carrier Transmitter Receiver)
Actual Power Capacity in RUS

P1B (CXP 104 0015/1)

1.1.16 New views


Radio equipment setup view.
1.1.17 New function
Support for Mixed mode.

1.1.18 Modified function


Define Node Parameters
o

Define hub position for support systems

R42H

1.2 New Configurations


Support for RBS 6301
o

One sector single band uncombined and combined


configurations: 1x2, 1x4

One sector dual band uncombined and combined


configurations: 2|2 and 2|4

Two sector single band uncombined and combined


configurations: 2x2, 2+4 and 2x4

Two sector dual band uncombined and combined


configurations: 2x2|2x2 and 2x4|2x2

Three sector single band uncombined and combined


configurations: 2+2+4, 2+4+4, 3x2 and 3x4

Three sector dual band uncombined and combined


configurations: 3x2|3x2

Four Way Receiver Diversity configurations:


1x2, 2x2 and 3x2

1.2.1 New views


RBS 6301 cabinet view and radio view.
1.2.2 New function
Support for Windows 7.

R41H

1.2.3 New Configurations


Support for RBS 6102 V1 RUG
o

One sector single band uncombined and combined


configurations: 1x2, 1x4

One sector dual band uncombined and combined


configurations: 2|2 and 2|4

Two sector single band uncombined and combined


configurations: 2x2, 2+4 and 2x4

Two sector dual band uncombined and combined


configurations: 2x2|2x2 and 2x4|2x2

Three sector single band uncombined and combined


configurations: 2+2+4, 2+4+4, 3x2 and 3x4

Three sector dual band uncombined and combined


configurations: 3x2|3x2

Four Way Receiver Diversity configurations:


1x2, 2x2 and 3x2

Support for RBS 6202 and RBS 6101 RUG


o

One to six sector configurations.

Support for Left and Right adjusted RUG configurations


o

One sector uncombined and combined configurations: 1x2.

Two sector uncombined and combined configurations: 2x2.

Three sector uncombined and combined configurations: 3x2.

1.2.4 New views


RBS 6102 V1 RUG cabinet view and radio view.
RBS 6202 cabinet view and radio view.
1.2.5 New Monitors
Fan fault LED.

R40J
1.2.6 New Configurations
RBS 6101, RBS 6102, RBS 6201 and RBS 6601: configurations up
to:

6x4 Single TX

3x8 Dual TX

3x12 Tripple TX

3x16 Quad TX

Support for all frequencies

Support for 4-way receiver diversity

Support for symmetric and asymmetric number of carriers


between the sectors

1.2.7 New views


RBS 6101 cabinet view and radio view.
RBS 6102 cabinet view and radio view.
RBS 6601 cabinet view and radio view.
Note: New view handling for RBS 6000. If the position for an RU is not
defined the unit will not be shown in the cabinet view. To set RU position
use function Define RU position.

1.2.8 New function


Define RU position for RBS 6000 configurations.
Define CPRI parameters
Define MCTR configuration
Define Node parameters
Display MCTR Configuration
Display TRXC HW Allocation
1.2.9 Modified function
Defined external nodes are displayed in the System view

Create IDB: RBS Configuration wizard can be started from the Final
Configuration Selection window of Create IDB

Create IDB for RUS/RRUS configurations:


o

Parameter setting for all antenna sectors is moved to one


dialog.

Mapping of TRXs to MCTRs are part of Create IDB

1.2.10 New monitors


VSWR at TX Antenna for RUS/RRUS
RI[A] RI[F] LEDS for DUG 20
R39H
1.2.11 New Configurations
Support for RBS 6201 V2
o

One sector single band uncombined and combined


configurations: 1x2, 1x4

One sector dual band uncombined and combined


configurations: 2|2 and 2|4

Two sector single band uncombined and combined


configurations: 2x2, 2+4 and 2x4

Two sector dual band uncombined and combined


configurations: 2x2|2x2 and 2x4|2x2

Three sector single band uncombined and combined


configurations: 2+2+4, 2+4+4, 3x2 and 3x4

Three sector dual band uncombined and combined


configurations: 3x2|3x2

Four Way Receiver Diversity configurations:


1x2, 2x2 and 3x2

RBS 2107 supports the same configurations as RBS 2207.

1.2.12 New views


RBS 6201 V2 cabinet view and radio view.

1.2.13 New function


Define Power and Battery

1.2.14 Modified function


Define Alarm Inlets
Load Flash Card

1.2.15 New monitors


PDU Information
PDU Voltage
GPS Signal to noise ratio

R38C

1.2.16 New function


Multiple CCCH

Monitor TS Channel Combination updated.

Display Paging Queue status updated, added monitors for


timeslot number 2, timeslot number 4 and timeslot number 6.

R37A

1.2.17 New function


Support for Windows Vista.

1.2.18 Modified function


Define Delay for ESB, reduced the value range for TG Instance.
New value range is 0-511.

R36_5

1.2.19 New function


Improved OMT information regarding additional active OMT
connection

OMT and ROMT is updated with the same


warning/information as ROMTIP when trying to connect to a
RBS where a connection has already been established.

New Lost Frame and Buffer Delay Measurements for Packet ABIS.
o

Monitor Super Channel Quality is updated, see the online


help for more information.

Check Battery Backup Time

1.2.20 Modified function


Create IDB
o

STN Equipment item PSTU is removed.

STN Equipment item SIU is removed for RBS 2101, RBS


2102, RBS 2103, RBS 2202, RBS 2301, RBS 2302 and RBS
2401.

Define Battery Parameters is not possible to select in mixed


configurations
PF Passive data is also checked in Check IDB function

1.2.21 New monitors


Fast Antenna Hopping Table

1.2.22 Modified function


Define Battery Backup Time Test
o

The date and time for the next battery backup time test will be
shown.

The test result for the previous test, and how long time the
test was executed before it was stopped will be shown.

The input of the stop level system voltage for the backup time
test will be removed.

R35_7

1.2.23 New Configurations


Support for RBS 2116 V2 and RBS 2216 V2 (Same configurations
as RBS 2x16).

Support for RBS 2111 V2, GSM 800/900/1800/1900


o

One sector uncombined configurations: 1x2, 1x4, 1x6 and


1x2 with splitter (Highway coverage).

One sector EHCU combined configurations: 1x4 and 1x6

Two sector uncombined configurations: 2x2, 2+4 and 4+2


single and dual band

Two sector mixed uncombined and EHCU combined


configurations: 2+4 and 4+2 single and dual band

Antenna sharing with other RBS 2111 V2 EHCU combined


configurations: 2+4 and 4+2 single and dual band.

Three sector uncombined configurations: 3x2 single and


dual band.

RBS 2111
o

One sector uncombined configurations: 1x2 with splitter


(Highway coverage).

RBS 2106, RBS 2106i, RBS 2106 V3, RBS 2206 and RBS 2206 V2
CDU-K configurations
o

One sector uncombined and combined configurations: 1x2,


1x4, 1x6.

Two sector uncombined and combined configurations: 2x2


and 2x4.

Three sector uncombined and combined configurations: 3x2.

Three sector combined configurations: 3x4.

1.2.24 New views


RBS 2116 V2 and RBS 2216 V2 cabinet views.
RBS 2111 V2, radio view.
1.2.25 Modified views
Radio views have been updated to display four and six sector
configurations correct.
RBS 2111, added splitter to radio view.

1.2.26 Modified functions


Display Log, a more detailed log is supported if present in the RBS.
Create IDB. Support for SIU.
Check IDB. UC/HC manual switch position is checked against IDB.
Display HW Information. UC/HC manual switch position is reported.
Display Status. Added Uncomb LED status.
Display IDB info have been updated to display four and six sector
configurations correct.
Timeouts have been removed on all operations communicating with
the RBS. The user can cancel an ongoing operation.
OMT installation. Menu shortcuts are removed correctly on uninstall.
OMT performance enhancement.

1.

Memory usage for the OMT application has been reduced.

Start-up time for the OMT application has been reduced.

R34_10

Modified functions
Added missing pictures in the online help.

2.

Modified views
Radio view for RBS 2116 and RBS 2216:
o

Port names on the splitter corrected.

R34_9

1.2.27 Modified functions


Check IDB:
o

Support for RBS 2116.

Faulty number of DRU is displayed now.

Memory usage of OMT is reduced.


Create IDB dialog:

New button Display Detected HW Info added.

Radio button Detected HW Info was removed.

Define Antenna Supervision now also in connected state.


On-line help for Super Channel Quality monitor.
RF Loop test monitors. The following monitors were removed:
o

Monitor RF Loop Test BER

Monitor RF Loop Test - Burst Q A

Monitor RF Loop Test - Burst Q B

Monitor RF Loop Test - RX level A

Monitor RF Loop Test - RX level B

Check IDB, added a control between the IDB and the RBS SW
capabilities.
On-line help and description in monitor window for Super Channel
Quality monitor.
Create IDB dialog box.

1.2.28 New function


Improved PM for Packet Abis

1.2.29 Modified views


Radio view for RBS 2308:
o

Tool tip on connection points with port names.

Show Cable info in Radio view.

1.2.30 New Configurations


RBS 2116, RBS 2216 GSM 900 and GSM 1800. The following
configurations are introduced:
o

One sector combined configurations without RXS with


optional TMA: 1x8, 1x10, 1x12

Two sector combined configurations without RXS with


optional TMA: 2+8, 4+8, 8+2, 8+4

Two sector mixed uncombined and combined configurations


without RXS with optional TMA: 2+8, 4+8, 8+2, 8+4

Three sector combined configurations without RXS with


optional TMA: 2+2+8, 8+2+2, 4+2+6, 6+2+2, 6+2+4, 6+2+2.

Three sector mixed uncombined and combined


configurations without RXS with optional TMA: 2+2+8,
8+2+2, 4+2+6, 6+2+2, 6+2+4, 6+2+2.

Three sector mixed uncombined and combined


configurations with RXS with optional TMA: 2+2+8, 8+2+2.

Three sector dual band uncombined configurations without


RXS with optional TMA: 3x2|3x2.

Three sector dual band combined configurations without


RXS with optional TMA: 2+2+4|2+2+0, 2+4+2|2+0+2, 4+2+2|
0+2+2, 2+4+4|2+0+0, 4+4+2|0+0+2, 4+2+4|0+2+0, 3x2|3x2.

Three sector dual band mixed uncombined and combined


configurations without RXS with optional TMA: 2+2+4|
2+2+0, 2+4+2|2+0+2, 4+2+2|0+2+2, 2+4+4|2+0+0, 4+4+2|
0+0+2, 4+2+4|0+2+0, 3x2|3x2, 2+3+3|2+0+2, 3+3+2|0+2+2.

RBS 2116, RBS 2216 GSM 900 and GSM 1800. The following
configurations are introduced:
o

Four sector single band uncombined and combined


configurations with optional TMA: 4x2.

Four sector single band mixed uncombined and combined


configurations with optional TMA: 4+2+2+4, 4+4+2+2,
2+2+4+4.

Six sector single band combined and uncombined configurations with


optional TMA: 6x2.
CDU-G in RBS 2x07, RBS 2112 and RBS 2204.

R33_7

1.2.31 New function


Define Antenna Supervision
RBS Multi TG support

1.2.32 New monitors


RX path imbalance

1.2.33 Modified functions


Define PCM renamed to Define Transmission

Selection of STN equipment added in Create IDB dialog


Define Present RUs, support for RBS 3018 in RBS 2106 cabinet

1.2.34 New Configurations


RBS 2111 GSM 900 and GSM 1800
o

Single band configuration uncombined: 1x4, 1x6, 2+4, 4+2

Dual band configuration uncombined: 2+4, 4+2

Single band configuration combined in first sector


uncombined in second sector: 4+2

Single band configuration uncombined in first sector


combined in second sector: 2+4

Single band configuration combined with sharing: 2+4, 4+2

Dual band configuration combined with sharing: 2+4, 4+2

RBS 2106V3 Support.


CDU-K in RBS 2106, RBS 2106i, RBS 2106V3, RBS 2206 and RBS
2206V2.

R32_7

1.2.35 New functions


RBS 2216 E-GSM

1.2.36 New Configurations


RBS 2216 GSM 900 and GSM 1800
o

Single band configuration mix of combined and uncombined


with and without TMA in all sectors independently:
2+4, 4+2

Single band splitter configuration mix of combined and


uncombined with and without TMA in all sectors
independently:
2+10, 10+2

Dual band configuration mix of combined and uncombined


with and without TMA in all sectors independently:
2+4, 4+2, 2+2+4, 2+4+2, 4+2+2, 4+4+2, 4+2+4, 2+4+4, 2x4|
2x2

Dual band splitter configuration mix of combined and


uncombined with and without TMA in all sectors
independently:
2+10, 10+2, 2+2+4, 2+4+2, 4+2+2, 4+4+2, 4+2+4, 2+4+4,
2x4|2x2

R32_6

1.2.37 New Configurations


RBS 2216 GSM 900 and GSM 1800

Single band uncombined configurations:


1x2, 1x4, 1x6, 2x2, 2+3+3, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4,
3+3+2, 4+2+2, 4+2+4, 4+4+2 with and without TMA in all
sectors independently
2+4, 2+6, 2+2+4, 3+3+4 with optional TMA in first sectors
and with or without TMA in last sector
4+2, 6+2, 4+2+2, 4+3+3 with or without TMA in first sector
and optional TMA in other sectors
2+4+2 with or without TMA in second sector, and optional
TMA in other sectors
2+4+4 with optional TMA in first sector and with or without
TMA in other sectors
4+2+4 with optional TMA in second sector and with or
without TMA in other sectors
4+4+2 with optional TMA in third sector and with or without
TMA in other sectors
2x4, 4+6, 6+4, 3x4 without TMA in any sector
2x4, 4+6, 6+4, 2x6, 3x4 with TMA in all sectors
2x4, 4+6, 6+4, 2x6, 3x4 with TMA in first sector and without
TMA in other sectors
3x4 with and without TMA in first and third sector and with
TMA in second sector
2x4, 4+6, 6+4, 2x6, 3x4 without TMA in first sectors and with
TMA in last sector
3x4 with TMA in first sectors and without TMA in last sector
3x4 without TMA in first sector and with TMA in other sectors

Single band uncombined splitter configurations:


1x4, 1x6, 2x4, 2x6, 2+4, 2+6, 2+2+4, 2+3+3, 2+4+2, 2+4+4,
3x4, 3+3+2, 3+3+4, 4+2, 4+6, 4+2+2, 4+2+4, 4+4+2, 4+3+3,
6+2, 6+4 with and without TMA in all sectors independently
4+6 without TMA in first sector and optional TMA in second
sector
4+6 with TMA in first sector and optional TMA in second
sector

Single band combined configuration with and without TMA in


all sectors independently:
1x2, 1x4, 1x6, 1x8, 1x10, 1x12, 2x2, 2x4, 2x6, 2+4, 2+6,
2+8, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 4+2, 4+6, 4+8, 4+2+2,
4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4

Single band combined splitter configuration with and without


TMA in all sectors independently:
1x2, 1x4, 1x6, 1x8, 1x10, 1x12, 2x4, 2x6, 2+4, 2+6, 2+8,
2+2+4, 2+4+2, 2+4+4, 3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4,
4+4+2, 6+2, 6+4, 8+2, 8+4

Single band configuration mix of combined and uncombined


with and without TMA in all sectors independently:
2+3+3, 3+3+2, 3+3+4, 4+3+3

Single band splitter configuration mix of combined and


uncombined with and without TMA in all sectors
independently:
2+3+3, 3+3+2, 3+3+4, 4+3+3

Single band 4-way receiver diversity configurations with


TMA:
1x4, 2x4, 3x4

Single band 4-way receiver diversity splitter configurations


with TMA:
1x2, 2x2, 2+2+4, 2+4+2, 2+4+4, 3x2, 4+2+2, 4+2+4, 4+4+2

Single band RX antenna sharing configurations with TMA:


4+8

Dual band uncombined configurations:


2x2, 2+3+3, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 3+3+2, 4+2+2,
4+2+4, 4+4+2, 2x2|2x2, 3x2|3x2 with and without TMA in all
sectors independently
2+4, 2+6, 2+2+4, 3+3+4 with optional TMA in first sectors
and with or without TMA in last sector
4+2, 6+2, 4+2+2, 4+3+3 with or without TMA in first sector
and optional TMA in other sectors
2+4+2 with or without TMA in second sector, and optional
TMA in other sectors
2+4+4 with optional TMA in first sector and with or without
TMA in other sectors
4+2+4 with optional TMA in second sector and with or
without TMA in other sectors
4+4+2 with optional TMA in third sector and with or without
TMA in other sectors
2x4, 4+6, 6+4, 3x4 without TMA in any sector
2x4, 4+6, 6+4, 2x6, 3x4 with TMA in all sectors
2x4, 4+6, 6+4, 2x6, 3x4 with TMA in first sector and without
TMA in other sectors
3x4 with and without TMA in first and third sector and with
TMA in second sector
2x4, 4+6, 6+4, 2x6, 3x4 without TMA in first sectors and with
TMA in last sector
3x4 with TMA in first sectors and without TMA in last sector
3x4 without TMA in first sector and with TMA in other sectors
2x4|2x2 with and without TMA in first and third sector and
optional TMA in other sectors
2x4|2x2 with TMA in first sector, without TMA in third sector
and optional TMA in other sectors
2x4|2x2 without TMA in first sector, with TMA in third sector
and optional TMA in other sectors

Dual band uncombined splitter configurations:


2x4, 2x6, 2+4, 2+6, 2+2+4, 2+3+3, 2+4+2, 2+4+4, 3x4,
3+3+2, 3+3+4, 4+2, 4+6, 4+2+2, 4+2+4, 4+4+2, 4+3+3, 6+2,
6+4, 2x4|2x2|3x2 with and without TMA in all sectors
independently
4+6 without TMA in first sector and optional TMA in second
sector
4+6 with TMA in first sector and optional TMA in second
sector

Dual band combined configuration with and without TMA in


all sectors independently:
2x2, 2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x2,
3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2,
8+4, 2x2|2x2, 2x4|2x2, 3x2|3x2

Dual band combined splitter configuration with and without


TMA in all sectors independently:
2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x4, 4+2,
4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4, 2x4|
2x2

Dual band configuration mix of combined and uncombined


with and without TMA in all sectors independently:
2+3+3, 3+3+2, 3+3+4, 4+3+3

Dual band splitter configuration mix of combined and


uncombined with and without TMA in all sectors
independently:
2+3+3, 3+3+2, 3+3+4, 4+3+3

RBS 2111 GSM1800.

Single band uncombined configurations:


1x2, 2x2, and 3x2

Single band combined configurations:


1x4 and 1x6

Dual band uncombined configurations:


1x2 + 1x2, 1x2 + 2x2 and 2x2 + 1x2

RBS 2206V2 Support (Same configurations as RBS 2206).

1.2.38 Modified views


Show Current Injectors in Radio View
Filter Cables in Radio View
Show Antenna System in Radio view as defined
Show Cable info in Radio view
Display OMT version and RBS type in System View
Radio view:
o

Radio paths inside ASU/CXU/HCU/SPLITTER.

Tool tip on connection points with port names.

1.2.39 New functions


RF Cable Supervision in 2216 configurations
Display RX/TX Antenna Mapping.
OMT Improvements
o

Remain in same OMT view as defined

R31_9

1.3 R31_5
1.3.1 New configurations
RBS 2206, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900
with TMA single band 2 and 4-Way receiver diversity configurations.
8+4 and 4+8 combined
RBS 2x06, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900
with and without TMAs in all sectors independently.
4+2 uncombined
RBS 2216, GSM 900
3x2 and 3x4 combined and uncombined
RBS 2108, GSM 900.
1x1, 2x1 and 3x1
RBS 2111, GSM 900.
1x4 and 1x6 combined
1x2, 2x2 and 3x2 uncombined

1.3.2 New functions


Support for RBS 2108
Support for RBS 2111
Support for RBS 2216
Monitor Report Header
Display Faulty RUs
Check IDB
Improved description of define parameters
ABIS optimizations
ABIS over IP

1.3.3 New views


RBS 2108 cabinet and radio views
RBS 2111 cabinet and radio views
RBS 2216 cabinet and radio views

1.3.4 New objects


MU
DRU_DRU_RXA, DRU_DRU_RXB, SPLITTER_DRU_RXA,
SPLITTER_DRU_RXB, PSU_A

1.3.5 New monitors


New monitors added as part of ABIS Optimizations:
Super Channel Quality
Super Channel Configuration

1.3.6 Modified functions:


Create IDB:
o

Split of TX Combining and RX antenna sharing

1.3.7 Modified views


Radio view has been updated to show ASUs and EXTERNAL_CDU.
Cabinet view for RBS 2206 has been updated with Splitter.

R30_4
1.3.8 New Configurations
Mixed Micro RBSs
1 RBS 2308 + 1 RBS 2302
1 RBS 2308 + 2 RBS 2302
2 RBS 2308 + 1 RBS 2302

2 RBS 2308 + 2 RBS 2302


1 RBS 2309 + 1 RBS 2302
1 RBS 2309 + 2 RBS 2302
2 RBS 2309 + 1 RBS 2302
2 RBS 2309 + 2 RBS 2302
RBS 2x06, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900
with and without TMAs in all sectors independently.
2+4, 3+3 uncombined.
4+4 combined in first sector and uncombined in second sector.
4+4 uncombined in first sector and combined in second sector.
RBS 2x06, CDU-G GSM 800 and GSM 900 with and without TMAs in
all sectors independently.
8+4 HCU in the first sector and combined in the second sector.
4+8 combined in the first sector and HCU in the second sector.
8+2 HCU in the first sector and combined or uncombined in the second
sector.
2+8 combined or uncombined in the first sector and HCU in the second
sector.
4+8, 8+4 with HCU and ASU.
1x8 with HCU.
RBS 2206, CDU-G GSM 1800 and GSM 1900 with TMA single band 4Way receiver diversity1[1] configurations:
1x8, 1x12
RBS 2106, CDU-G GSM 1800 and GSM 1900 with TMA
single band 4-Way receiver diversity12 configurations:
1x8, 1x12, 2x4, 2x6, 3x4

1.3.9 New functions


BSS R12 System Improvements, BTS
Fault Filtering.
Compress IDB.
1
2

Compress SW Log.
Increased Transmission Speed
RBS 2000 Synchronization.
Enable Bypass TMA on RBS 2101, RBS 2102 and RBS 2202.

1.3.10 New monitors


New monitors added as part of TG Synchronization Improvements
ESB Measurement of ESB Delay active/inactive
Measured ESB Delay
Master transmitter chain delay
Master transceiver group instance number
ESB timeslot for measurements of ESB delay

R29_3

1.3.11 New Functions


Support for RBS 2250
Support for RBS 2106i

1.3.12 New Configurations


RBS 2250:
o

GSM 800 and GSM 1900 single band configurations:


1x4, 1x8, 1x12

RBS 2109:
o

GSM 900 and GSM 1800 single band configurations:


1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2
and 1x6

Dual band configurations:


1x2|1x2, 1x2|1x4 and 1x4|1x2

RBS 2x07:
o

CDU J GSM 900 combined and uncombined (including


mixed) single band configurations with TMA:

1x4, 2+4 and 4+2.


o

CDU J GSM 800, GSM 1800 and GSM 1900 combined and
uncombined (including mixed) single band configurations
with and without TMA:
1x4, 2+4 and 4+2.

RBS 2107:
o

CDU J GSM 900 combined and uncombined (including


mixed) single band configurations without TMA:
1x4, 2+4 and 4+2

1.3.13 New views


RBS 2250 cabinet and radio views
RBS 2106i cabinet and radio views

R28_2

1.3.14 New Configurations


RBS 2106:
GSM 800 | GSM 1900 and GSM 900 | GSM 1800 3 sector dual band
configurations:
3x2 | 3x2 combined, uncombined and mixed
1+1+2 | 1+1+2
3x2 | 1+1+2 combined and uncombined
CDU F GSM 1900 single band configurations: 1x4, 1x8, 1x12, 2x6, 2x4,
3x4, 4+8 and 8+4
Four Way Receiver Diversity configurations: 1x8, 1x12, 2x4, 2x6 and
3x4
3+3+3 configurations.
RBS 2206:
CDU F GSM 1900 single band configurations: 1x4, 1x8, 1x12, 2x6, 2x4,
3x4, 4+8 and 8+4
Four Way Receiver Diversity configurations: 1x8 and 1x12
3+3+3 configurations.
RBS 2112:
GSM 900 single band configurations: 1x2 combined and uncombined

1.3.15 Modified views


Radio views have been updated to show TMA, Hybrid Combiner and
HCU if available.

1.3.16 New function


Four Way Receiver Diversity in RBS 2106 and RBS 2206
RBS 2309 P-GSM

1.3.17 New views


RBS 2112 cabinet and radio views

1.3.18 New monitors for three sector dual band configurations:


TMA Current on TMA_CM object.
TMA Voltage on TMA_CM object.

R26_5
1.3.19 New configurations:
RBS 2109:
o

Single band configurations GSM 800 and GSM 1900:


1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2
and 1x6

Dual band configurations:


1x2|1x2, 1x2|1x4 and 1x4|1x2

RBS 2309:
o

Single band configurations GSM 900 and GSM1800:


1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2
and 1x6

Dual band configurations:


1x2|1x2, 1x2|1x4 and 1x4|1x2

RBS 2107:
o

CDU J single band configurations:

1+1, 1x2, 1+1+2, 2x2 and 3x2 uncombined


1x2, 2x2 and 3x2 combined
1+1+2, 2x2 and 3x2 uncombined/combined
o

CDU J dual band configurations:


1x2|1x2, 1x2|2x2 and 2x2|1x2 uncombined,
combined and uncombined/combined mixed.

1.3.20 New views:


RBS 2109, RBS 2309, RBS 2107 cabinet and radio views.

1.3.21 New functions:


RBS SW load indicator
Extended RBS Holdover Time
Simplified Software handling
RBS name in IDB
Battery event and stress log
Support for Externally Powered TMAs

1.3.22 Modified function:


Display Software Information
o

Shows Filepackage name or Loadfile name

RBS 2308
o

Possible to define more than one antenna system in a


antenna sector.

Information that is entered in the Create IDB function is not


displayed in Display Information window for the RBS 2000 object
any longer. This information can be found in Display Information
window for the IDB object.

R23_9

1.3.23 New configurations:


RBS 2207:
o

Mixed CDU J/G single band configurations:

1+1, 1+1+2, 2x2 and 3x2 uncombined


2x2 and 3x2 combined
o

CDU J single band configurations:


1+1, 1x2, 1+1+2, 2x2 and 3x2 uncombined
1x2, 2x2 and 3x2 combined
1+1+2, 2x2 and 3x2 uncombined/combined

CDU J dual band configurations:


1x2|1x2, 1x2|2x2 and 2x2|1x2 uncombined,
combined and uncombined/combined mixed.

R23_5

1.3.24 Modified function:


Define ALNA/TMA Parameters.

R23_2

1.3.25 New configurations:


RBS 2x06:
o

Dual band 1x2|1x4

2x3, 3+3+2, 3+3+4 combined

4+8, 8+4 with ASU

8+4, 4+8, 8+2, 2+8 HCU in one cell, uncombined/combined


in other cell

1x12, 1x8 with HCU

4+8, 8+4 with HCU and ASU

RBS 2207:
o

1x2, 1+1, 2x2, 1+1+2, 3x2

3x2, 2x2, 1x2 combined

RBS 2308:
o

1x4, 1x8, 1x12, 2x2, 2x4, 2x6, 3x4, 4+8, 8+4, 2+2+4, 4+2+2
900, 1800 duplex

1x4, 1x12, 2x2, 2x4, 1x8, 3x4, 4+8, 8+4 1900 simplex

1.3.26 New functions:


OMT Wizard
Define GPS Parameters

1.3.27 New views:


RBS 2207 cabinet and radio views

1.3.28 New objects:


ASU, ASU_CDU_RXA, ASU_CDU_RXB, ASU_CXU_RXA,
ASU_CXU_RXB, CDU_ASU_RXA, CDU_ASU_RXB,
CDU_HCU_TX, EXTERNAL_CDU, HCU

1.3.29 New monitors:


GPS position, GPS status, GPS satellites, GPS time - week, GPS
time - seconds, GPS time - std dev.

1.3.30 Modified views:


Cabinet view:
o

Added ASU and HCU for RBS 2106 and RBS 2206

1.3.31 Modified functions:


OMT Wizard not supported on Win98, ME and NT.
Fault status added on ASU for ASU_RXA units or cables and
ASU_RXB units or cables Fault status added on ASU_CDU_RXA
and ASU_CDU_RXB
Monitor MO Fault maps, added Description, Action and Related
faults
Fault status added on DXU for GPS RX and GPS RX DXU

R22_3

1.3.32 New functions:


Compare HW and IDB.
Define Battery Backup Time Test Parameters.
Display Battery Backup Time Test Parameters.

Display Battery Backup Time Test Result.


Display Detected HW Information.

1.3.33 Modified functions:


Create IDB: Detected HW Information support.
Define Battery Parameters: More parameters added.
Install IDB: Detected HW Information support.

R21_3

1.3.34 New configurations:


Support of double DXU EDGE.
Mix of TMA/no TMA & combined/uncombined dTRUs in RBS
2106/2206.
2x4, 3x4, 2x2 for RBS 2308, GSM 800.
1x4, 2x4, 3x4, 2x2 for RBS 2308, GSM 1900, duplex.
1x4 for RBS 2308.

1.3.35 New monitors:


TMA Current on TMA_CM object.
TMA Voltage on TMA_CM object.

1.3.36 Modified functions:


Updated Load Flash Card description in OMT manual.
Monitor: Monitor selection from Maintenance menu is simplified.
o

Monitors will be started by:


1. Select a specific monitor.
2. Select object to monitor.

Monitor: Monitors previously available on both AO objects and SO


objects are now only available on SO objects.
Monitor: MO fault status changed to MO fault map, supporting
extended fault reporting.
Renamed Load DXU Flash Card to Load Flash Card

Display Status: Fault status on TIM.


Display Cable List: Logical cable names added.

1.3.37 New objects:


IXU, RRU, TIM, RXBP, RRU_RXBP_RXA, RRU_RXBP_RXB.

1.3.38 New views:


RBS 2308 cabinet and radio views.

1.3.39 New options:


COM port number.

R20

1.3.40 New functions:


Define Antenna Hopping.
Define Battery Parameters.
Define System Voltage.

1.3.41 New monitors:


Antenna hopping table list.

1.3.42 Modified functions:


Display/Import Site Specific Data (System Voltage and Battery
Parameters added).

1.3.43 New views:


Object view.

1.3.44 Other changes:


OMT main window: New menus: RBS 2000, Edit, Configuration,
Maintenance, Tools.
Toolbar modifed: New icons for Connect/Disconnect.
Not present RUs are selectable in all views.

MO view removed. MO objects available in Object view.


Object menu replaced by Object view.
Operation menu removed. Available by right mouse-click.

R19_1

1.3.45 New configurations:


1x4, 1x6 for CDU-G, GSM 900/1800/1900
Dual band 900/1900 for RBS 2202
800 MHz for 2206 and 2106

1.3.46 New objects:


AODP-2, AODP-3.

1.3.47 Modified functions:


Define PCM: Now supporting 4 transmission ports.
Display Status:
o

Fault status added on PCM for DP-2 and DP-3.

Monitor:
o

Line attenuation and Phase difference Error for PCM C and


PCM D added.

1.3.48 Modified views:


MO view : Added DP2 and DP3.

1.3.49 New Remote OMT Hardware:


Thor-2-PCI communication board also supported on Windows XP.

R17_5
-

R17_4

1.3.50 New configurations:


RBS 2106, 2206.
TMA selection per sector (2102, 2202, 2106 and 2206).

1.3.51 New objects:


OMT objects: DXU Flash Card.
Active RUs: ACCU_02_DU, CCU_01, CXU, FCU, RBS_2106,
RBS_2206, TMA_CM.
Passive RUs: ACCU_02_CU, ACT_COOL_FAN,
CDU_CDU_PFWD, CDU_CDU_PREF, CDU_CXU_RXA,
CDU_CXU_RXB, CDU_TX_TX, CNU, CXU_TRU_RXA,
CXU_TRU_RXB, TRU_TRU_TX1, TRU_TRU_TX2.

1.3.52 New functions:


Define Climate.
Load DXU Flash Card.

1.3.53 Modified functions:


Define ALNA/TMA Parameters (TMA type added).
Define VSWR Limits: Now also possible in Connected state.
Display/Import Site Specific Data (Climate added).
Display Status:
o

Fault status added: Battery temp sensor, IOM bus,


CDU_CDU_PFWD, CDU_CDU_PREF, CDU_CXU_RXA,
CDU_CXU_RXB, CXU_TRU_RXA, CXU_TRU_RXB, FCU,
Flash card, HCOMB, TMA_CM, Y link, BFU fuse.

LED status added: Fault LED, Operational LED, Local Mode


LED, Reduced Capacity LED, Battery fault LED, External
alarm LED, RBS fault / BS fault LED, EPC bus fault LED,
Transmission OK LED, Battery mode LED, DC disconnect
LED, AC fault LED, FAN Fault LED, TMA OK LED, RF off
/TX not enabled LED.

Display SW Versions renamed to Display RBS SW Information.


o

If RBS SW is 8.1A or newer, the file package information is


displayed else the load file names are displayed.

Modify IDB renamed to Define Present RUs.

Define Present RUs (DC/DC Converter added).


Monitor:
o

BDM Information, BFU Information and PSU Information


added.

Save RBS Log renamed to Display RBS Log, and opens a Notepad
window.

1.3.54 New views:


2106, 2206 cabinet and radio views.

1.3.55 Modified views:


Hardware view -> Radio view.
Radio view:
o

ECU and ENV objects removed.

PFWD and PREF connections displayed.

1.3.56 New Remote OMT Hardware:


Thor-2-PCI communication board supported on Windows
98/ME/NT/2000.

R14_3

1.3.57 New Remote OMT Hardware:


THOR-2-PCI communication board.

R14_1

1.3.58 New functions:


Display Paging Queue Status

1.3.59 Modified functions :


Connect R-OMT with selectable timeslot
Display faulty RU and other monitors executes much faster
Define TF Compensation only in local state

1.4 R12
1.4.1 New functions:
Define PCM / Receiver Sensitivity A & B
Define TF Compensation
Define Delay

1.4.2 Modified functions:


Define PCM
Import Site Specific Data

1.4.3 New objects :


ESB

1.4.4 Modified Views:


Hardware view shows faulty RU
System view

Limitations

It is recommended to connect the OMT application to the RBS before


running a wizard. The OMT might stop responding if a wizard is aborted
during the connection phase.

System software and hardware requirements


2

System software requirements


Either of following operating systems:
Microsoft Windows XP
Microsoft Windows Vista
Microsoft Windows 7
The following additional software:
Microsoft Internet Explorer 5.0 or higher

Microsoft Windows Installer 3.1 or higher. Windows Installer 3.1 will


be automatically installed if not present on the target system, with a
subsequent reboot required.
Administrator rights on the computer are required to install the OMT
program.

Hardware requirements
An IBM compatible PC with a processor that fulfils the operating
system requirements. For good performance it's recommended to
use a Pentium 4-compatible processor of at least 1 GHz.
At least 50 Megabytes available hard disk space.
At least 512 MB of RAM.
Mouse (optional)
A VGA graphic card.
1 serial port and serial cable (To be able to connect an OMT PC with
USB port to an RBS 2000 an USB-serial port adapter is needed).

Installing the OMT software

The OMT is installed by executing the installation file: \OMT\Setup.exe,


found on the OMT installation CD-ROM. All OMT software on the CD-ROM
is then installed to a specified, or default (C:\Program Files\Ericsson
AB\OMT_<XXX>), directory on the hard disk.
1. Insert the OMT installation CD-ROM into the CD-ROM drive.
2. Run the OMT installation program by browsing to and double
clicking the file \OMT\Setup.exe or by executing it from the Run...
alternative in the Start menu.
3. Follow the set-up instructions on the screen.
The installation creates a new program group called OMT where the OMT
icon can be found.
The OMT can now be started either by double-clicking on the icon or by
selecting the icon from the Start menu.
To uninstall one version of the OMT
1. Select Settings | Control Panel.
2. Click on Add/Remove Programs.
3. Select the OMT to be uninstalled and click on the Add/Remove
button.

When upgrading from an earlier version of the OMT, the new version will be
installed in another folder and a new icon will be added to the program
group.