You are on page 1of 5

Observation Set 1

For ZnSO4 electrolyte with Zn electrodes

Sr.No

Temperature Reading Of Reading Of Resistance


Ammeter
Voltmeter

R=V/I

Conductance

C=I/R

23 C

100 mA

1.0 V

10

0.100

-1

26 C

100 mA

0.95 V

9.5

0.105

-1

29 C

110 mA

0.89 V

8.09

0.120

-1

32 C

110 mA

0.84 V

7.63

0.130

-1

35 C

120 mA

0.80 V

6.66

0.150

-1

38 C

125 mA

0.75 V

6.00

0.160

-1

41 C

130 mA

0.71 V

7.6

0.180

-1

44 C

130 mA

0.65 V

5.00

0.200

-1

Graph of Observation Set


1

Scale:
conductance: 1unit=0.05Mho

Zinc Sulphate Electrolyte


0.25

0.2

0.15

Conductance(in Mho)
0.1

0.05

23

26

29

32

35

38

41

Teperature(in degree celsius)

Observation Set 2
For CuSO4 electrolyte

44

Sr.
No.

Temperature

Reading Of Reading Of Resistance Conductance


Ammeter Voltmeter
I

R=V/I

C=I/R

25 C

75 mA

1.4 V

18.67

0.053

-1

28 C

75 mA

1.35 V

18.00

0.055

-1

31 C

75 mA

1.3 V

17.33

0.057

-1

34 C

75 mA

1.25 V

16.67

0.060

-1

36 C

80 mA

1.2 V

15.00

0.066

-1

38 C

80 mA

1.15 V

14.38

0.069

-1

42 C

80 mA

1.10 V

13.75

0.072

-1

44 C

85 mA

1.10 V

12.94

0.075

-1

47 C

85 mA

1.05 V

12.35

0.080

-1

10

49 C

90 mA

1.10 V

11.11

0.090

-1

11

53 C

90 mA

1.90 V

10.00

0.100

-1

Graph of Observation Set


2

scale:
conductance: 1unit=0.05Mho

Copper Sulphate Electolyte


0.12

0.1

0.08

Conductance in (Mho)

0.06

0.04

0.02

25 28 31 34 36 38 42 44 47 49 53

Teperature (in degree celsius)

You might also like