Professional Documents
Culture Documents
Catalog Zelio Logic EN PDF
Catalog Zelio Logic EN PDF
Zelio Logic
Catalogue
November
06
12345652578
1 Interchangeable
modular functions,
to better meet the
requirements for
extensions
1 Software and
accessories common to
multiple product families
This international site allows you to access all the
Telemecanique products in just 2 clicks via
comprehensive range data-sheets, with direct
links to:
1 Complete library: technical documents, catalogs,
certificates, FAQs, brochures...
1 Selection guides from the e-catalog.
1 Product discovery sites and their Flash
animations.
You will also find illustrated overviews, news to
which you can subscribe, a discussion forum, the
list of country contacts...
To live automation solutions every day!
3578
1 Auto-adapts to its
9
73
1 High functionality in a
minimum of space
1 Freedom in
implementation
33
1 Compliance with field
bus, connection, and
software standards
1 Enabling
decentralised or remote
surveillance via the web
with Transparent Ready
products
525578
1 Cost effective
optimum offers that
make selection easy for
most typical applications
1 Products that are
easy to understand for
users, electricians and
automation specialists
1 User-friendly intuitive
programming
Contents
Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 6 to 9
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 10 to 12
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 14 to 19
Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 20 and 21
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 22 to 27
Dimensions, mounting, schemes. . . . . . . . . . . . . . . . . . . . . . . . . . pages 28 to 31
Communication
1 Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 32
Programming protocol
1 Description, characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33
Communication
1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 40
1 Dimensions, mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
Analogue interfaces
Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 56 and 57
1
1
1
1
Selection guide
Product type
Supply voltage
1 24 V
Number of I/O
12
20
10
12
20
8 (0)
12 (0)
6 (0)
8 (0)
12 (0)
4/0
8/0
4/0
4/0
8/0
SR2 B 1B
FBD or LADDER
SR2 MEM02
(1 incompatible with SR2 COM01)
SR2 MEM02
(1 incompatible with SR2 COM01)
1 100240 V
22
22
SR2 E 1B
FBD or LADDER
22
22
22
22
SR2 B 1FU
FBD or LADDER
SR2 A 1FU
LADDER only
SR2 E 1FU
FBD or LADDER
SR2 D 1FU
LADDER only
SR2 PACK FU
SR2 COM01
Zelio Logic Alarm SR2 SFT02
SR2 1111B
SR2 1111FU
22 and 23
22 and 23
Pages
(1) FBD: Function Block Diagram.
3 12 V
3 24 V
12
20
10
12
20
8 (4)
12 (6)
6 (0)
8 (4)
12 (2), 12 (6)
4/0
8/0
4/0
4/0, 0/4
8/0, 0/8
22
222
222
222
222
SR2 B 1JD
FBD or LADDER
SR2 B
BD
FBD or LADDER
SR2 A
BD
LADDER only
SR2 E
BD
FBD or LADDER
SR2 D
BD
LADDER only
SR2 MEM02
(1 incompatible with SR2 COM01)
SR2 MEM02
(1 incompatible with SR2 COM01)
SR2 PACK BD
SR2 COM01
Zelio Logic Alarm SR2 SFT02
RM
2 222BD
2 222BD
ABL 7RM1202
ABL 7RM24011
SR2 B111JD
SR2 1111BD
22
22 and 23
Selection guide
Product types
Supply voltage
1 24 V
1 100...240 V
Number of I/O
Number of discrete inputs
(of which analogue inputs)
Number of relay/transistor outputs
10
6 (0)
26
16 (0)
10
6 (0)
26
16 (0)
4/0
10/0
4/0
10/0
Yes
FBD or LADDER
Yes
FBD or LADDER
SR2 MEM02
(1 incompatible with SR2 COM01)
SR2 MEM02
(1 incompatible with SR2 COM01)
SR3 PACK1BD
SR2 COM01
Zelio Logic Alarm SR2 SFT02
SR2 COM01
Zelio Logic Alarm SR2 SFT02
SR3 B111B
SR3 B
Number of I/O
10
14
10
14
4 (0)
6 (0)
8 (0)
4 (0)
6 (0)
8 (0)
2 (0)
4 (0)
6 (0)
2 (0)
4 (0)
6 (0)
References
SR3 XT111B
SR3 XT111FU
Pages
25
25
221FU
3 12 V
3 24 V
26
16 (6)
10
6 (4)
26
16 (6)
10/0
4/0, 0/4
10/0, 0/10
Yes
FBD or LADDER
Yes
FBD or LADDER
SR2 MEM02
(12incompatible with SR2 COM01)
SR2 MEM02
(12incompatible with SR2 COM01)
SR3 PACK1BD
SR2 COM01
Zelio Logic Alarm SR2 SFT02
RM
24222BD
SR2 COM01
Zelio Logic Alarm SR2 SFT02
24222BD
RM
22
ABL 7RM1202
ABL 7RM240
SR3 B261JD
SR3 B111BD
or
and
or
2 Number of words:
3 4 (inputs)
3 4 (outputs)
3 4 (clock)
3 1 (status)
2 Number of words:
3 4 (inputs)
3 4 (outputs)
3 4 (clock)
3 1 (status)
10
14
0 (2)
4 (0)
6 (0)
8 (0)
0 (2)
2 (0)
4 (0)
6 (0)
SR3 XT111JD
SR3 MBU01BD
SR3 NET01BD
SR3 XT43BD
SR3 XT111BD
25
40
44
25
10
14
4 (0)
6 (0)
8 (0)
2 (0)
4 (0)
6 (0)
Presentation
109446
Presentation
Zelio Logic smart relays are designed for use in small automated systems. They are
used in both the industrial and commercial sectors.
2 For industry:
23automation of small finishing, production, assembly or packaging machines.
23decentralised automation of ancillary equipment of large and medium-sized
machines (textile, plastics, materials processing sectors etc.),
23automation systems for agricultural machinery (irrigation, pumping, greenhouses
etc.).
Their compact size and ease of setting-up make them a competitive alternative to
solutions based on cabled logic or specific cards.
2 Programming
Combination of modular smart relays with I/O
extension and communication modules
2
109458
Simple programming, ensured by the universal nature of the languages, meets all the
requirements of automation specialists and also the needs of the electrician.
Programming can be performed:
23independently, using the buttons on the Zelio Logic smart relay (ladder language),
23on a PC using Zelio Soft 2 software.
When using a PC, programming can be performed either in LADDER language or in
function block diagram (FBD) language, see pages 8 to 12.
Backlighting of the LCD display (1) is obtained by activating one of the 6 programming
buttons on the Zelio Logic smart relay or by programming with Zelio Soft 2 software
(example: flashing in the event of a malfunction).
000003-26
To improve performance and flexibility, Zelio Logic modular smart relays can be fitted
with communication modules and I/O extension modules to obtain a maximum of
40 I/O:
1 Modbus or Ethernet communication modules, supplied with 5 24 V via the
Zelio Logic smart relay at the same voltage.
1 analogue I/O extension modules with 4 I/O, supplied with 5 24 V via the
Zelio Logic smart relay at the same voltage,
1 discrete I/O extension modules with 6, 10 or 14 I/O, supplied via the Zelio Logic
smart relay at the same voltage.
(1) LCD: Liquid Crystal Display.
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Presentation (continued)
Communication
536135
523409
1 These programming tools allow the Zelio Logic smart relay to be connected to a
PC running Zelio Soft 2 software:
23Link by cables:
- Cable SR2 CBL01 to 9-pin serial port
or
- Cable SR2 USB01 to USB port
Connecting cable
Bluetooth interface
23Wireless link:
- Bluetooth interface SR2 BTC01
534944
1 Memory cartridge
The Zelio Logic smart relay can be fitted with a backup memory cartridge which
enables the application program to be copied into another Zelio Logic smart relay.
However, loading and updating of the firmware (software embedded in the product)
is only possible with memory cartridge SR2 MEM02.
Memory cartridge
The memory cartridge also enables a backup copy of the program to be saved prior
to replacing the product.
When used with a smart relay without display or buttons, the copy of the program
contained in the cartridge is automatically transferred into the Zelio Logic smart relay
on power-up.
540454
536136
Ethernet
communication module
534941
534943
Modbus
communication module
534942
Analogue
PSTN Modem
They are designed for monitoring or remote control of machines or installations which
operate without personnel.
The Modem communication interface supplied with 5 12...24 V, enables messages,
telephone numbers and calling conditions to be stored, see pages 46 to 55.
(1) Public Switched Telephone Network.
(2) Global System Mobile.
Modem
communication interface
Functions :
pages 10 to 12
GSM Modem
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Presentation
1 Zelio Soft 2 monitoring mode makes it possible to test the program executed by
the smart relay, i.e.:
23display the program on-line,
23force inputs, outputs, control relays and current values of the function blocks,
23adjust the time,
23change from STOP mode to RUN mode and vice versa.
Simulation mode
In simulation or monitoring mode, the monitoring window allows the status of the
smart relay I/Os to be displayed within your application environment (diagram or
image).
Monitoring window
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Presentation (continued)
User interfaces
Version 4.1 of "Zelio Soft 2" software improves, amongst other things, the ease of
use of user interfaces for the following functions:
1
2
3
4
5
6
7
Waiting
2
zzzz
3
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Functions
LADDER language
Definition
Timer
Up/down counter
Fast counter
Analogue comparator
Clock
Control relay
Counter comparator
LCD backlighting
Output coil
Message
Functions
22
or
14
LADDER language
21
Electrical scheme
13
Function
Contact
I
or
Notes
I corresponds to the real state of the contact connected to the
input of the smart relay.
i corresponds to the inverse state of the contact connected to the
input of the smart relay.
i
The coil is energised when the contacts to which it is connected
are closed.
A2
A1
Standard coil
A2
Unlatch coil
(Reset)
A1
A2
A1
Presentation:
pages 6 to 9
10
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Functions (continued)
Function block diagram language (FBD / Grafcet SFC / Logic functions) (1)
Definition
FBD language allows graphical programming based on the use of predefined function blocks; it provides the use of:
1 32 functions for counting, time delay, timing, definition of switching threshold, (for example: temperature regulation), generation of impulses,
time programming, multiplexing, display,
1 7 SFC functions,
1 6 logic functions.
Pre-programmed functions
Zelio Logic smart relays provide a high processing capacity, up to 200 function blocks, including 32 pre-programmed functions:
TIMER AC
TIMER BH
TIMER Li
TIMER BW
Pulse generator
(ON-delay, OFF-delay)
Pulse generator
with external preset adjustment
(ON-delay, OFF-delay)
BOOLEAN
Cam programmer
Hour counter
(hour, minute preset)
ADD/SUB
Allows conversion of an
analogue value by change of
scale and offset.
MUL/DIV
Zone comparison
(Min. Value Max.)
COM
COMPARE
UP DOWN COUNT
Multiplexing functions on
2 analogue values
COMP IN ZONE
54
DISPLAY
54
Timer. Function BW
(pulse on rising/falling edge)
CAM
PRESET COUNT
GAIN
Up/down counter
TRIGGER
STATUS
Comparison of 2 analogue
values using the operands
=, >, <, 4, 5.
CNA
Fast counting up to
1 kHz
Analog/digital converter
Digital/analog converter
STEP
DIV-OR 2
SL In
TEXT
Storage of 2 values
simultaneously
SL Out
INIT STEP
Reinitialisable step
DIV-AND 2
Initial step
CONV-AND 2
Divergence to AND
Convergence to AND
SFC step
Divergence to OR
CONV-OR 2
Convergence to OR
Logic functions
AND
OR
AND function
OR function
(1) Functional Block Diagram
(2) Sequential Function Chart.
Presentation:
pages 6 to 9
Characteristics:
pages 14 to 19
NAND
NOR
NOT OR function
Curves :
pages 20 and 21
XOR
Exclusive OR function
References:
pages 22 to 27
NOT
NOT function
Dimensions, schemes:
pages 28 to 31
11
Functions (continued)
Function block diagram language (FBD / Grafcet SFC / Logic functions) (continued)
Macro Function
A Macro is a grouping of function blocks. It is characterised by its number, its name,
its links, its internal function blocks (255 max.) and by its I/O connections.
Seen from the outside, a Macro behaves like a function block with inputs and/or
outputs that can be connected to links.
Once created, a Macro can be manipulated like a function block.
1 Macro characteristics:
23The maximum number of Macros is 64.
23A password dedicated to Macros can be used to protect their content,
23A Macro can be edited / duplicated,
23A Macro's comments can be edited.
Creation of a Macro
1 Macro properties:
A "Macro properties" dialogue box allows the properties of a Macro to be entered or
edited.
The properties of a Macro are:
23Macro name (optional)
23The block Symbol, which may be:
- an identifier,
- an image.
23Name of inputs.
23Name of outputs.
Inside of a Macro
1
2
3
4
5
6
Macro selection
Edit properties
Allows return to external view of a Macro
Internal function block within the Macro
Non connected inputs
Non connected outputs
Outside of a Macro
1 Input connections
2 Output connection
Presentation:
pages 6 to 9
12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Description
4
5
1 2
4
5
Presentation, functions:
pages 6 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
13
Characteristics
Conducted and
radiated emissions
Screw terminals connection
capacity
Conforming to 73/23/EEC
Conforming to 89/336/EEC
Conforming to IEC/EN 60529
Conforming to IEC/EN 60664-1
Conforming to IEC/EN 61131-2
Operation
C
C
Storage
mm2
mm2
Tightening torque
N.m
Processing characteristics
Number of control
scheme lines
Number of function blocks
Cycle time
Response time
Back-up time
(in the event of power failure)
120
Up to 200
6...90
Input acquisition time + 1 to 2 cycle times
10 years (lithium battery) at 25 C
10 years
On each power-up
12 min/year (0 to 55 C)
6 sec/month (at 25 C and calibration)
1% 2 of the cycle time
(1) Except for configuration SR3 B111BD + SR3 MBU01BD + SR3 XT43BD or
SR3 B111BD + SR3 NET01BD + SR3 XT43BD class A (class B: work in progress).
Presentation:
pages 6 to 9
14
Functions :
pages 10 to 12
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Characteristics (continued)
Without extensions
With extensions
Without extensions
With extensions
Permissible duration
V
V
Hz
mA
mA
VA
VA
ms
V
SR
Voltage
Current
Frequencies
At state 1
At state 0
Voltage
Current
Voltage
Current
V
mA
Hz
V
mA
V
mA
k
ms
ms
ms
ms
A
Utilisation
category
DC-12
DC-13
AC-12
AC-15
Presentation:
pages 6 to 9
No-load
At Ie (operational current)
In millions of operating cycles
Conforming to IEC/EN 60947-1
and IEC/EN 60664-1
Set
Reset
Against short-circuits
Against overvoltage
and overload
Functions :
pages 10 to 12
V
A
V
A
V
A
V
A
mA
SR3 B101B
SR3 B261B
160
280
4
7.5
280
415
7.5
10
2 2222B
6724
4,4
47...53 and 57...63
5 6714
>2
4 675
< 0.5
4.6
50
50
50 min., 255 max. (in increments of 10)
50 min., 255 max. (in increments of 10)
None
None
Yes (control instructions not executed)
SR2 121B
SR2 201B
6724
6 20.428.8
50-60
145
233
4
6
4 10 (repeated 20 times)
671780
SR2 121B
SR2 201B
SR3 B101B
SR3 XT101B
8 5...30, 6 24...250
N/O
4 outputs: 8 A 8 outputs: 8 A
SR3 B261B
SR3 XT61B
SR3 XT141B
8 outputs: 8 A
2 outputs: 5 A
2 outputs: 8 A
4 outputs: 8 A
2 outputs: 5 A
8724
1.5
67230
1.5
67230
0.9
10
8712 V - 10 mA
Hz
Hz
kV
ms
ms
10
0.1
10
4
10
5
None
None
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
15
Characteristics (continued)
Without extensions
With extensions
Without extensions
With extensions
Permissible duration
V
V
Hz
mA
mA
VA
VA
ms
V
2
2
SR2 101FU
SR2 121FU
6 100240
6 85264
50-60
80/30
10
671780
SR2 201FU
SR3 B101FU
SR3 B261FU
100/50
80/30
80/40
7
12
100/50
80/60
12
17
11
Voltage
Current
Frequencies
At state 1
At state 0
Voltage
Current
Voltage
Current
V
mA
Hz
V
mA
V
mA
k
ms
ms
ms
ms
2 2222
SR
FU
6 100... 240
0.6
47...53 and 57...63
5 6779
> 0.17
4 6740
< 0.5
350
50
50
50 min... 255 max. (in increments of 10)
50 min...255 max. (in increments of 10)
None
None
Yes (control instructions not executed)
2
2
Type
Presentation:
pages 6 to 9
16
V
A
V
A
V
DC-13
A
AC-12
V
A
AC-15
V
A
At minimum voltage of 8712 V mA
8724
No-load
At Ie (operational current)
In millions of operating cycles
Conforming to IEC/EN 60947-1
and IEC/EN 60664-1
Set
Reset
Against short-circuits
Against overvoltage
and overload
10
0.1
10
4
Utilisation
category
Functions :
pages 10 to 12
DC-12
Hz
Hz
kV
ms
ms
SR2 101FU
SR2 201FU
SR2 121FU
SR3 B101FU
SR3 XT101FU
8 5...30. 6 24...250
N/O
4 outputs: 8 A 8 outputs: 8 A
SR3 B261FU
SR3 XT61FU
SR3 XT141FU
8 outputs: 8 A
2 outputs: 5 A
2 outputs: 8 A
4 outputs: 8 A
2 outputs: 5 A
1.5
67230
1.5
67230
0.9
10
8712 V - 10 mA
10
5
None
None
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Characteristics (continued)
Including ripple
Without extensions
With extensions
Without extensions
With extensions
Permissible duration
Against reversed polarity
V
V
mA
mA
W
W
ms
SR2 B121JD
8712
8 10.414.4
120
1.5
4 1 (repeated 20 times)
Yes
SR
Voltage
Current
At state 1
At state 0
Voltage
Current
Voltage
Current
V
mA
V
mA
V
mA
k
kHz
V
k
V
SR2 B201JD
SR3 B261JD
200
250
400
3
5
2.5
2 2222JD
2 2222JD
SR
5 8 5.6
52
4 8 2.4
587
5 0.5
483
< 0.9
2.7
Type 1
Yes PNP
No
Resistive
None
None
1
Yes (control instructions not executed)
< 0.2
14
Type 1
Yes PNP
No
Resistive
None
None
1
Yes (control instructions not executed)
2 2222
SR
JD (inputs IBIG used as analogue inputs)
8 0...10 or 8 0...12
14
8714.4
39 mV
Common mode
8 bits at maximum voltage
Smart relay cycle time
5 % at 25 C and 6.2 % at 55 C
2 % at 55 C
None
10 max., with screened cable (sensor not isolated)
Yes
V
A
Utilisation category DC-12
DC-13
AC-12
AC-15
Minimum switching
At minimum voltage of 8712 V
capacity
Low power switching reliability of contact
Maximum operating rate No-load
At Ie (operational current)
Mechanical life
In millions of operating cycles
Rated impulse withstand Conforming to IEC/EN 60947-1
voltage (Uimp)
and IEC/EN 60664-1
Response time
Set
Reset
Built-in protection
Against short-circuits
Against overvoltage and overload
V
A
V
A
V
A
V
A
mA
SR2 B121JD
SR2 B201JD
SR3 XT101JD
8 5...30, 6 24...250
N/O
4 outputs: 8 A 8 outputs: 8 A
SR3 B261JD
SR3 XT61JD
SR3 XT141JD
8 outputs: 8 A
2 outputs: 5 A
2 outputs: 8 A
4 outputs: 8 A
2 outputs: 5 A
8724
1.5
67230
1.5
67230
0.9
10
8712 V - 10 mA
Hz
Hz
kV
ms
ms
10
0.1
10
4
10
5
None
None
17
Characteristics (continued)
Including ripple
Without extensions
With extensions
Without extensions
With extensions
Permissible duration
Against reversed polarity
V
V
mA
mA
W
W
ms
Voltage
Current
At state 1
At state 0
Voltage
Current
Voltage
Current
V
mA
V
mA
V
mA
k
kHz
Presentation:
pages 6 to 9
18
Functions :
pages 10 to 12
V
k
V
22
SR2
SR2
SR2
1 1BD B122BD
201BD
8724
19.230
100
3
6
4 1 (repeated 20 times)
Yes
SR2
SR3
SR3
SR3
SR3
B202BD B101BD B102BD B261BD B262BD
100
3
2 2222
SR
BD
(input I1IA, IHIR)
8724
4
5 8 15
5 2.2
485
< 0.75
7.4
Type 1
Yes PNP
No
Resistive
None
None
1
Yes (control instructions not executed)
50
160
4
190
300
6
10
70
180
5
2 2222
SR
BD
(input IBIG used as discrete input)
8724
4
5 8 15
5 1.2
485
< 0.5
12
Type 1
Yes PNP
No
Resistive
None
None
1
Yes (control instructions not executed)
2 2222
SR
BD (input IBIG used as analogue inputs)
8 0...10 or 8 0...24
12
8730
39 mV
Common mode
8 bits at maximum voltage
Smart relay cycle time
5 % at 25 C and 6.2 % at 55 C
2 % at 55 C
None
10 maximum, with screened cable (sensor not isolated)
Yes
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Characteristics (continued)
A
Utilisation
category
DC-12
DC-13
AC-12
AC-15
At minimum voltage of 8 12 V
No-load
At Ie (operational current)
In millions of operating cycles
Conforming to IEC/EN 60947-1
and IEC/EN 60664-1
Set
Reset
Against short-circuits
Against overvoltage
and overload
V
A
V
A
V
A
V
A
mA
2
2
Residual voltage
Response time
Built-in protection
Nominal voltage
Nominal current
Maximum current
At state 1
Set
Reset
Against overload and
short-circuits
Against overvoltage (1)
Against inversions of
power supply
SR3 B261BD
SR3 XT61BD
SR3 XT141BD
8 outputs: 8 A
2 outputs: 5 A
2 outputs: 8 A
4 outputs: 8 A
2 outputs: 5 A
8724
1.5
67230
1.5
67230
0.9
10
8712 V - 10 mA
Hz
Hz
kV
ms
ms
10
0.1
10
4
10
5
None
None
SR2 101BD
SR2 201BD
SR2 121BD
SR3 B101BD
SR3 XT101BD
8 5...30. 6 24...250
N/O
4 outputs: 8 A 8 outputs: 8 A
V
V
A
A
V
ms
ms
2 22
SR B 2BD
8 19.2..0.30
8724
0.5
0.625 at 30 V
4 8 2 for I = 0.5 A
41
41
Yes
Yes
Yes
(1) If there is no volt-free contact between the Zelio Logic smart relay output and the load.
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Curves :
pages 20 and 21
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
19
Curves
d.c. loads
DC-12 (1)
3,0
2,5
48 V
2,0
24 V
1,5
1,0
0,5
0,0
0
0,5
1,5
Current (A)
Current (A)
DC-13 (2)
1,4
Millions of operating cycles
L/R = 10 ms 48 V
1,2
L/R = 10 ms 24 V
1,0
L/R = 60 ms 48 V
0,8
L/R = 60 ms 24 V
0,6
0,4
0,2
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
(1) DC-12: switching resistive loads and photo-coupler isolated solid-state loads, L/R 4 1 ms.
(2) DC-13: switching electromagnets, L/R 4 2 x (Ue x Ie) in ms, Ue: rated operational voltage,
Ie: rated operational current (with a protection diode on the load, DC-12 curves must be used
with a coefficient of 0.9 applied to the number in millions of operating cycles).
Presentation:
pages 6 to 9
20
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
Curves (continued)
a.c. loads
AC-12 (1)
3,0
2,5
24 V
2,0
48 V
1,5
110 V
1,0
230 V
0,5
0,0
0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
1,2
1,4
1,6
4,5
Current (A)
AC-14 (2)
2,5
2,0
110 V
1,5
230 V
1,0
48 V
24 V
0,5
0,0
0
0,2
0,4
0,6
0,8
1,0
2 Current (A)
1,8
AC-15 (3)
1,0
Millions of operating cycles
0,9
0,8
110 V
0,7
230 V
0,6
48 V
0,5
0,4
0,3
0,2
0,1
0,0
0,5
0,7
0,9
1,1
1,3
1,5
1,7
1,9
Current (A)
(1) AC-12: switching resistive loads and photo-coupler isolated solid-state loads, cos 5 0.9.
(2) AC-14: switching small electromagnetic loads 4 72 VA, make: cos = 0.3, break: cos = 0.3.
(3) AC-15: switching electromagnetic loads > 72 VA, make: cos = 0.7, break: cos = 0.4.
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
References:
pages 22 to 27
Dimensions, schemes:
pages 28 to 31
21
References
109440
Reference
Weight
kg
Supply 3 24 V
12
20
8
12
0
0
4
8
0
0
Yes
Yes
SR2 B121B
SR2 B201B
0.250
0.380
Supply 3 100...240 V
10
No
0.250
12
Yes
SR2 B121FU
0.250
20
12
No
Yes
0.380
0.380
4
6
4
8
0
0
Yes
Yes
SR2 B121JD
SR2 B201JD
0.250
0.380
536307
SR2 A201BD
Supply 4 12 V
12
20
8
12
Supply 4 24 V
10
No
0.250
12
4
0
0
4
Yes
Yes
SR2 B121BD
SR2 B122BD
0.250
0.220
20
12
2
6
8
8
0
0
0
8
No
Yes
Yes
0.380
0.380
0.280
536308
SR2 SFT01
Application
Reference
SR2 SFT01
Application
Reference
Weight
kg
0.200
Accessories
Connection accessories
Description
Connecting cable
Length
Between the PC
3m
(USB connector)
and the Zelio Logic
smart relay
Other accessories: see pages 26 and 27
536306
SR2 PACK111
SR2 USB01
Weight
kg
0.100
Weight
kg
Supply 3 100...240 V
12
20
SR2 B121FU
SR2 B201FU
SR2 PACKFU
SR2 PACK2FU
0.700
0.850
SR2 PACKBD
SR2 PACK2BD
0.700
0.700
Supply 4 24 V
12
20
SR2 B121BD
SR2 B201BD
Presentation:
pages 6 to 9
22
Functions :
pages 10 to 12
Application
Reference
Weight
kg
0.200
Modem communication
For SR2 B
See page 52
interface
(1) Programming on Zelio Logic smart relay in LADDER language only.
(2) CD-ROM comprising Zelio Soft 2 software, an application library, a self-training manual,
installation instructions and a users manual.
(3) Replaces cable SR2 CBL01 which is still available separately, as an accessory (see page 26).
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
References (continued)
Reference
Weight
kg
Supply 3 24 V
12
Yes
SR2 E121B
0.220
20
12
Yes
SR2 E201B
0.350
Supply 3 100...240 V
SR2 E121BD
10
No
0.220
12
Yes
SR2 E121FU
0.220
20
12
No
0.350
Yes
SR2 E201FU
0.350
536307
Supply 4 24 V
10
No
0.220
12
Yes
SR2 E121BD
0.220
20
12
No
0.350
Yes
SR2 E201BD
0.350
Description
Programming software
Zelio Soft 2 software,
multi-language
Application
Reference
SR2 SFT01
Application
Reference
Weight
kg
0.200
523109
Accessories
Connection accessories
Description
SR2 USB01
Connecting cable
Length
Between the PC
3m
(USB connector)
and the Zelio Logic
smart relay
Other accessories: see pages 26 and 27
SR2 USB01
Weight
kg
0.100
Supply 4 12...24 V
Description
Modem communication
interface
Application
For SR2 E
Reference
See page 52
Weight
kg
0.200
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
23
References
Reference
Weight
kg
Supply 3 24 V
10
Yes
SR3 B101B
0.250
26
16
10 (1)
Yes
SR3 B261B
0.400
Supply 3 100...240 V
10
Yes
SR3 B101FU
0.250
26
16
10 (1)
Yes
SR3 B261FU
0.400
10 (1)
Yes
0.400
Yes
SR3 B101BD
0.250
Yes
SR3 B102BD
0.220
10 (1)
Yes
SR3 B261BD
0.400
10
Yes
SR3 B262BD
0.300
Supply 4 12 V
SR3 B101BD
26
16
Supply 4 24 V
536307
10
26
16
SR2 SFT01
Application
Reference
SR2 SFT01
Application
Reference
Weight
kg
0.200
Accessories
Connection accessories
Description
Between the PC
3m
(USB connector)
and the Zelio Logic
smart relay
Other accessories: see pages 26 and 27
523109
Connecting cable
Length
SR2 USB01
SR2 USB01
Weight
kg
0.100
Weight
kg
536308
Supply 3 100...240 V
10
SR3 B101FU
SR3 PACKFU
0.700
26
SR3 B261FU
SR3 PACK2FU
0.850
Supply 4 24 V
10
SR3 B101BD
SR3 PACKBD
0.700
26
SR3 B261BD
SR3 PACK2BD
0.850
SR2 PACK111
Presentation:
pages 6 to 9
24
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
References (continued)
524132
SR3NET
22
22
Network
Reference
Modbus
See page 40
Weight
kg
0.110
Ethernet
See page 40
0.110
Ethernet
communication module
109363
2 (3)
Including
0 - 10 V
2 max
Including
0 - 20 mA Pt100
2 max
1 max
Output
Reference
4 0-10 V
2
Weight
kg
See page 44
0.110
Relay outputs
Reference
Weight
kg
SR3 XT61B
0.125
10
SR3 XT101B
0.200
14
6 (4)
SR3 XT141B
0.220
109369
SR3 XT61BD
SR3 XT61FU
0.125
10
SR3 XT101FU
0.200
14
6 (4)
SR3 XT141FU
0.220
SR3 XT61JD
0.125
10
SR3 XT101JD
0.200
14
6 (4)
SR3 XT141JD
0.220
536306
SR3 XT141BD
SR3 XT61BD
0.125
10
SR3 XT101BD
0.200
14
6 (4)
SR3 XT141BD
0.220
Reference
See page 52
Weight
kg
0.200
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
25
References
536307
Programming
Zelio Soft 2 software for PC
Description
Programming software
Zelio Soft 2 software,
multi-language
Application
Reference
SR2 SFT01
Application
Reference
Weight
kg
0.200
Connection accessories
Description
SR2 SFT01
523109
Connecting cables
SR2 USB01
Bluetooth interface
for Zelio Logic smart relays
536135
Bluetooth adapter
for non-equipped PC
SR2 BTC01
VW3 A8115
Application
Reference
Weight
kg
0.150
0.100
0.015
0.290
Memory cartridges(3)
Description
EEPROM
memory cartridges
Weight
kg
0.010
0.010
534944
Documentation
Description/application
Users manual
for direct programming on
the Zelio Logic smart relay
SR2 MEM02
Language
Reference
English
SR2 MAN01EN
Weight
kg
0.100
French
SR2 MAN01FR
0.100
German
SR2 MAN01DE
0.100
Spanish
SR2 MAN01ES
0.100
Italian
SR2 MAN01IT
0.100
Portuguese
SR2 MAN01P0
0.100
(1) CD-ROM comprising Zelio Soft 2 software, an application library, a self-training manual,
installation instructions and a users manual.
(2) Can only be used with "Zelio Soft 2" software version 2 V 4.1.
(3) Program loading using memory cartridge SR2 MEM02 is incompatible with Modem
communication interface SR2 COM01.
Presentation:
pages 6 to 9
26
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
References (continued)
540472
Nominal
output voltage
8 5 V, 8 12 V or 8 24 V
Reference
See page 69
Weight
kg
Converters (2)
Description
Reference
109000
See page 62
Weight
kg
Converters for
thermocouples
DF563990
14211
Mounting capacity
Reference
Weight
kg
0.350
0.210
14210
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
Dimensions, schemes:
pages 28 to 31
27
Dimensions,
mounting
6 rail
Position of display
100
107,6
24
100
90
107,6
29
(1)
71,2
59,5
59,9
84
5,5
2x4
48
2x4
59,9
6 rail
Position of display
100
107,6
24
100
90
107,6
29
(1)
59,5
124,6
113,3
84
2x4
5,5
2x4
48
113,3
6 rail
90
100
107,6
Mounting on 35 mm
59,5
a
G
2x4
SR3
XT6111
XT10111
XT14111
a
35.5
72
72
G
25
60
60
104,5
104,5
101,5
101,5
186
Presentation:
pages 6 to 9
28
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
32
40,5
32
12x5
40,5
96
126
r=2
57
55
57
55
234
105
Schemes
SR3 B2611D
(1)
SRp ppppBD
c 24 V
SRp ppppJD
c 12 V
c 24 V
Q1
L/+
(1)
C Q8 Q9 QA
+ Q1
IA IB IC ID IE IF IG
Q2
Q3
Q4
5 A (4)
(3)
(2)
z 12240 V
50/60 Hz
c 1224 V
Q7
+ (2)
Q3
Q4
(3)
c 24 V
N/
Q2
z 24240 V
50/60 Hz
or
U
z 12240 V
50/60 Hz
(3)
(3)
U
c 1224 V
c 1224 V
(1)
BN BL
BL
BK
BN
BK
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
29
Schemes (continued)
0-10 V
ANALOG.
(1)
Ca / Ta
(3)
(2)
(1)
(4)
(5)
(5)
2 22
22
2
22
Ca / Ta
(2)
BL
(4)
BN
BK
BL
BN
BK
(3)
QB QC
QD QE
QF QG
Presentation:
pages 6 to 9
30
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
Schemes (continued)
(1)
SRp ppppB
a 24 V
SRp ppppFU
a 100240 V
50/60 Hz
N
Q1
L/+
IA IB IC ID IE IF IG
L N
Q2
Q3
Q4
z 12240 V
50/60 Hz
c 1224 V
N/
C Q8 Q9 QA
5 A (4)
(3)
(2)
Q7
(3)
or
U
c 1224 V
z 12240 V
50/60 Hz
+
Module
Extension
QB QC
QD QE
QF QG
Presentation:
pages 6 to 9
Functions :
pages 10 to 12
Characteristics:
pages 14 to 19
Curves :
pages 20 and 21
References:
pages 22 to 27
31
Presentation
109449
Communication
Presentation
In order to communicate with an intelligent environment, Zelio Logic smart relays and
their I/O extension and communication modules are equipped with various types of
communication port.
1 Zelio Logic modular smart relay I/O extension and communication modules offer:
231 Modbus RS 485 port on communication module SR3 MBU01BD,
231 Ethernet 10/100 base T port supporting the Modbus TCP protocol on
communication module SR3 NET01BD.
Smart relay
7
6
These three ports allow Zelio Logic compact or modular smart relays to use 3
communication protocols:
1 Programming,
1 Modbus,
1 Ethernet.
Communication ports on Zelio Logic smart relays and their I/O extension and
communication modules
4
5
32
Serial port
Physical layer
RS 232
Connector
000003-26
Communication
port
Modbus port on
communication
module
SR3 MBU01BD
RS 485
Ethernet port on
communication
module
SR3 NET01BD
10/100 base T
Modem
communication
interface port
RJ45
Specific to Zelio
All modules with
clock
SR2 B11111
SR2 E11111
(see page
52)
All types
(see page
52)
Compact
smart relays
All types
(connection and
isolation via cable
SR2 CBL01 or
SR2 USB01)
Modular
smart relays
All types
All modules with
(connection and
8724 V supply
isolation via cable SR3 B111BD
SR2 CBL01 or
SR2 USB01)
RS 232
Description,
characteristics
Communication
Programming protocol
524107
Description
Link by cable
1 Programming PC.
2 RS 232 serial link cable (SR2 CBL01) or USB cable (SR2 USB01) (1).
3 Zelio Logic compact or modular smart relay.
524106
Wireless link
4 Programming PC with integrated Bluetooth technology (or Bluetooth adapter
VW3 A8115 for PC not equipped with Bluetooth technology) (1).
5 Bluetooth interface (SR2 BTC01) for Zelio Logic smart relay (1).
6 Zelio Logic compact or modular smart relay.
524108
6
Link by Modem
7 Programming PC.
8 Modem interface connecting cable supplied with SR2 COM01 (2).
9 Modem for transmitting/receiving data SR2 MOD01 or SR2 MOD02 (2).
10 Telephone or radio link.
11 Communication interface SR2 COM01.
12 Zelio Logic compact or modular smart relay.
10
12
11
(1) See page 26.
(2) See page 52.
Kbit/s
Data bits
Stop bits
Parity
Pair
Physical layer
RS 232
Type of connector
33
Presentation,
description
Communication
524131
Presentation
The Modbus communication protocol is of the master/slave type.
Two exchange methods are possible:
1 Request/reply:
23The request from the master is addressed to a specific slave.
23The master waits for the reply to be returned by the slave polled.
1 Distribution:
23The master distributes a request to all the slave stations on the bus.
These stations execute the instruction without sending a reply.
Zelio Logic modular smart relays are connected to the Modbus network via the
Modbus slave communication module. This module is a slave that is not electrically
isolated.
The Modbus slave communication module must be connected to an SR3 B666BD
modular smart relay, with a 5 24 V supply.
524121
3
5
2
4
7
3
2
6
3
532522
1
7
7
(1) Programming from the front panel and buttons on the smart relay is only possible in LADDER
language.
(2) Please refer to installation instructions supplied with the product.
(3) The polarisation resistors must be managed by the master.
SR3 MBU01BD
COM
Description
3
2
4
PWR
MB485-V1
8
5
Characteristics:
page 35
34
Connection example
1
XBT N401 display unit.
Modular smart relay SR3 B111BD.
2
3
Modbus communication module SR3 MBU01BD.
4
Modbus network (cables VW3 A8 306R66).
5
Junction box TWD XCA T3RJ (polarisation and line end adapter activated).
5bis Junction box TWD XCA T3RJ (line end adapter activated).
6
T-junction 170 XTS 04100.
7
T-junction VW3 A8 306TF66.
Function description
1 The Modbus slave communication module is connected to a 2-wire or 4-wire
Modbus network (2).
1 The maximum length of the network is 1000 m (9600 bauds max., AWG 26).
1 A maximum of 32 slaves can be connected to the Modbus network, or a maximum
of 247 slaves with repeaters.
1 Line end adaptors must be fitted to both ends of the line
(1 nF/10 V, 120 /0.25 W in series).
1 The line must be polarised (470 /0.25 W resistors) (3).
1 The connection cable and its RJ45 male connectors must be screened.
1 The 7 terminal on the module must be connected directly to the protective earth
at one point on the bus.
5bis
Configuration
The Modbus slave communication module can be configured:
1 independently, using the buttons on the smart relay (1).
1 on a PC, using Zelio Soft 2 software, see page 9.
Functions :
page 36
References :
page 40
Dimensions, mounting :
page 41
Characteristics
Communication
Modbus slave communication protocol
Environment characteristics
Type
Product certifications
Conformity with the
low voltage directive
Conformity with the
EMC directive
Degree of protection
SR3 MBU01BD
UL, CSA, GL, C-TICK
EN (IEC) 61131-2 (open equipment)
Conforming to 73/23/EEC
Conforming to 89/336/EEC
Conforming to IEC/EN 60529
Overvoltage category
Degree of pollution
Ambient air temperature
around the device
Conforming to
IEC/EN 60068-2-1 and
IEC/EN 60068-2-2
Max. relative humidity
Maximum operating altitude
Presentation, description :
page 34
Functions :
page 36
C
C
References :
page 40
Dimensions, mounting :
page 41
35
Functions
Communication
Modbus slave communication protocol
Parameter entry
524121
Parameters can be entered either using Zelio Soft 2 software or directly using the
buttons on the Zelio Logic smart relay (1).
When the RUN instruction is given, the Zelio Logic smart relay initialises the
Modbus slave communication module in a configuration previously defined in the
basic program.
The Modbus slave communication module has 4 parameters:
number of UART wires and format of the frames on the Modbus network,
transmission speed,
parity,
network address of the Modbus module.
1
1
1
1
The default parameter settings are as follows: 2-wire, RTU, 19 200 bauds, even
parity, address n 1.
Software workshop
parameter entry window
Parameter entry
Number of wires
Frame format
Transmission speed
in bauds
Parity
Network address
Options
2 or 4
RTU or ASCII
1200, 2400, 4800, 9600, 19 200, 28 800, 38 400, 57 600
None, even, odd
1 to 247
524110
Input words
J1 3
XT1 7 2
J2 3
XT1 7 2
J3 3
XT1 7 2
J4 3
XT1 7 2
Code
Number of words
Read
03
Clock words
Read/Write
16, 06 or 03
Status words
Read
03
Output words
0
4
0
4
9 03
XT1
0
4
02
9 XT1
0
4
9 01
XT1
9 04
XT1
Code
Read/Write
16, 06 or 03
Number of words
4
Output words
Read
03
Clock words
Read/Write
16, 06 or 03
Status words
Read
03
(1) Programming from the front panel and buttons on the smart relay is only possible in LADDER
language.
36
Characteristics:
page 35
References :
page 40
Dimensions, mounting :
page 41
Presentation,
description
Communication
Ethernet server communication protocol
53631
Presentation
Zelio Logic modular smart relays are connected to the Ethernet network via the
Ethernet server communication module.
Communication module SR3 NET01BD allows communication on the Ethernet
network under the Modbus TCP protocol.
The Ethernet server communication module must be connected to an SR3 B666BD
modular smart relay, with a 5 24 V supply.
Ethernet server
communication module
Configuration
The Ethernet server communication module is configured from a PC with "Zelio Soft"
software, see page 9.
On the PC, programming is effected in function block (FDB) language, see pages 12
and 13.
7
6
Connection example
1 Twido client, 40 I/O compact base controller TWD LCAE 40DRF.
2 Ethernet network (cables 490 NTW 00066).
3 ConneXium 499 NES 251 00 Switch.
4 Zelio Logic modular smart relay SR3 B666BD.
5 Communication interface SR2COM01.
6 Connecting cable SR2 CBL07 (supplied with the Modem communication
interface).
7 GSM (or analogue PSTN) Modem.
8 Ethernet server communication module SR3 NET01BD.
9 Analogue I/O extension module SR3 XT43BD.
2
2
Function description
1 The Ethernet server communication module is connected to a local LAN type
network.
1 The maximum cable length between 2 devices is 100 m.
1 The connection cable must be at least category 5, and its RJ45 male connectors
must be screened.
1 The 7 terminal must be connected directly to the protective earth.
4
8
Description
Ethernet server communication module SR3 NET01BD comprises:
1
7
7
8
SR3 NET01BD
LK/ACT 10/100
3
2
4
1
2
3
4
5
6
7
8
STS
8
5
Characteristics:
page 38
Functions :
page 39
References :
page 40
Dimensions, mounting :
page 41
37
Characteristics
Environment characteristics
Type
Product certifications
Conformity with the
low voltage directive
Conformity with the
EMC directive
Degree of protection
SR3 NET01BD
UL, CSA, GL (pending), C-TICK (pending)
EN (IEC) 61131-2 (open equipment)
Conforming to 73/23/EEC
Conforming to 89/336/EEC
Conforming to IEC/EN 60529
Overvoltage category
Degree of pollution
Ambient air temperature
around the device
Conforming to
IEC/EN 60068-2-1 and
IEC/EN 60068-2-2
Max. relative humidity
Maximum operating altitude
Presentation, description :
page 37
Functions :
page 39
C
C
38
References :
page 40
Dimensions, mounting :
page 41
Functions
Communication
Ethernet server communication module
Parameter entry
Parameter entry must be carried out using Zelio Soft 2 software.
When the RUN instruction is given, the Zelio Logic smart relay initialises the
Ethernet server communication module in a configuration previously defined in the
basic program.
The Ethernet server communication module has 6 parameters:
1 type of addressing (dynamic or static).
1 IP address,
1 sub-network mask,
1 gateway address,
1 reserved address,
1 time out.
Ethernet communication module configuration window
J1 3
XT1 7 2
J2 3
XT1 7 2
J3 3
XT1 7 2
J4 3
XT1 7 2
Output words
0
4
0
4
02
9 XT1
9 03
XT1
0
4
01
XT1
0
4
In FBD mode, the 4 input data words (16 bits) (J1XT1 to J4XT1) and the 4 output
data words (O1XT1 to O4XT1) can be accessed by the application. Dedicated
function blocks make it possible to:
1 break down a complete type input (16 bits) into 16 separate bit type outputs.
23example: break down a J1XT1 to J4XT1 type input and copy these status values
to discrete outputs.
1 make up a complete type output (16 bits) from 16 separate bit type inputs.
23example: transfer the status value of the discrete inputs or the status of a function
to an O1XT1 to O4XT1 type output.
9 04
XT1
Ethernet exchanges
Input words
Code
Read/Write
16, 06 or 03
Number of words
4
Output words
Read
03
Clock words
Read/Write
16, 06 or 03
Status words
Read
03
Presentation, description :
page 37
Characteristics:
page 38
References :
page 40
Dimensions, mounting :
page 41
39
References
Communication
22
Network Reference
222BD (1)
Modbus
SR3 MBU01BD
Ethernet
SR3 NET01BD
(2), (3)
Weight
kg
0.110
0.110
Connection accessories
Accessory
T-junctions
Description
Network Length
m
Modbus 0.3
RJ45 connector
SR3 MBU01BD
Junction
boxes
SR3 NET01BD
Line end
adapter
RS 485
cables
2 x RJ45 connectors
Modbus
VW3 A8 306TF03
Weight
kg
0.190
VW3 A8 306TF10
0.210
Without
cable
0.020
0.100
0.080
VW3 A8306RC
0.200
0.3
VW3 A8306R03
0.030
VW3 A8306R10
0.050
VW3 A8306R30
0.150
Ethernet 2
12
40
80
conneXium
Ethernet
499 NES 251 00
0.190
switch
(1) Compatible with SR3 B112BD featuring hardware version H1.0.01, available since June
2005.
(2) Can only be used in FBD language.
(3) Can only be used with "Zelio Soft 2" software version 2 V 4.1.
(4) Cable conforming to EIA/TIA-568 standard category 5 and IEC 1180/EN 50 173, class D.
For UL and CSA 22.1 approved cables, add the letter U at the end of the reference.
40
Reference
Characteristics:
pages 35 to 38
Functions :
pages 36 to 39
Dimensions, mounting :
page 41
Dimensions,
mounting
Communication
Rail mounting
70
57
52,5
35
100
35
27.5
90
108
27.5
35
44
Presentation, description :
pages 34 to 37
15
Characteristics:
pages 35 to 38
25
Functions :
pages 36 to 39
2 x 4
References:
page 40
41
Presentation,
description
536279
Presentation
Modular smart relays and analogue I/O extension modules
To improve performance and flexibility, Zelio Logic modular smart relays can be fitted
with analogue I/O extension modules with 10-bit resolution.
The inputs accept 0-10 V, 0-20 mA and Pt 100 type signals.
Using a Zelio Logic modular smart relay with 5 24 V supply in conjunction with an
analogue 4 I/O extension module makes it possible to obtain up to 30 I/O, including
8 analogue inputs and 2 analogue outputs.
The analogue I/O extension module must be connected to an SR3 666BD modular
smart relay with a 5 24 V supply.
Analogue I/O
extension modules
Description
1
524127
524128
Characteristics:
page 43
42
References, dimensions :
page 44
Schemes:
page 45
Characteristics
Conducted and
radiated emissions
Connection capacity
to screw terminals
SR3 XT43BD
UL, CSA, C-Tick, GL (pending)
EN (IEC) 61131-2 (open equipment)
Conforming to 73/23/EEC
Conforming to 89/336/EEC
Conforming to IEC/EN 60529
Conforming to IEC/EN 60664-1
Conforming to IEC/EN 61131-2
Operation
Storage
- 40... + 70
Immunity to electromagnetic
radiated fields
Immunity to fast transients in bursts
Immunity to shock waves
Radio frequency in common mode
Voltage dips and breaks (6)
Immunity to damped oscillation
waves
Conforming to EN 55022/11
(Group 1)
Flexible cable with cable end
mm2
IEC/EN 61000-4-3
Semi-solid cable
Solid cable
mm2
mm2
Tightening torque
N.m
Conversion
Isolation
Cabling distance
Protection
Application
Assignable inputs
Input range
Input impedance
Maximum non destructive value
Value of LSB
Input type
Resolution
Conversion time
Precision
at 25 C
at 55 C
Repeat accuracy at 25 C
Between analogue channel and supply
m
Against reversed polarity
Conversion
Isolation
Cabling distance
Built-in protection
Presentation, description :
page 42
8 0-10 V
8 0-20mA
IH and IJ
IH and IJ
8 0...10 V
8 0...20 mA
18 k
247
8 30 V
8 30 mA
9.8 mV
20
Common mode
10 bits on the input range
Smart relay cycle time
1%
1%
<1%
None
10 maximum, with screened cable
Yes
Pt100
IJ
- 25 C...125 C
0,15 C
Pt100 probe - IEC 751 3-wire
1.5 C
1.5 C
< 0.3 C
(QB, QC)
Output range
Type of load
Maximum load
Value of LSB
Resolution
Conversion time
Precision
8 0..0.10
Resistive
10
9.8
10 bits on the output range
Smart relay cycle time
at 25 C
1% of the full scale value
at 55 C
1% of the full scale value
< 1%
Repeat accuracy at 55 C
Between analogue channel and supply
None
m
10 maximum, with screened cable
Yes
Against short-circuits
(1) Except for configuration SR3 B111BD + SR3 MBU01BD + SR3 XT43BD
or SR3 B111BD + SR3 NET01BD + SR3 XT43BD class A (class B: work in progress).
References, dimensions :
page 44
mA
mV
Schemes:
page 45
43
References,
dimensions
SR3 XT43BD
Dimensions
6 rail
100
90
=
107,6
Mounting on 35 mm
59,5
35,5
25
Presentation, description :
page 42
44
Characteristics:
page 43
Schemes:
page 45
2x4
Reference
Weight
kg
SR3 XT43BD(2),(3)
0.110
Schemes
Pt100
0
0
0
1
1
(1)
Q1
IH IJ Pt 0V
Q2
Q3
QB
Q4
0V QC
0 - 20 mA
(1)
IH IJ Pt 0V
Presentation, description :
page 42
Characteristics:
page 43
References, dimensions :
page 44
45
Presentation
523083
Presentation
The communication products in the Zelio Logic range are primarily designed for
monitoring or remote control of machines or installations which operate without
personnel.
Examples:
1 monitoring of lift pumps, livestock premises (ventilation, food level, etc.),
refrigeration units, car-washes,
1 alarm in the event of failure of industrial or domestic heating boilers,
1 remote control of lighting: car parks, warehouses,
1 remote control and monitoring of escalators in large stores, in the transport sector,
1 refuse compactor full alert.
The communication range comprises:
1 a communication interface connected between a smart relay and a Modem,
1 Modems: GSM (1) or analogue (PSTN) (2),
1 Zelio Logic Alarm software.
Modem
communication interface
Remote station
Transmission
network
Communication
interface
Receiving equipment
5
GSM
Analogue
PSTN
or
Analogue
PSTN
Modem
or
GSM Modem
Zelio Logic
smart relay
6
9
Various combinations are possible between the types of Modem used on the Remote
station and the type of Receiving device (PC + Modems or GSM telephone).
The type of architecture selected will therefore depend mainly on:
1 whether or not an analogue telephone line is available,
1 whether or not it is necessary to send SMS messages.
see page 49.
(6) Global System Mobile.
(7) Public Switched Telephone Network.
Functions, setting-up:
pages 48 and 49
46
Characteristics:
pages 50 and 51
References:
page 52
Dimensions:
page 53
Connections:
pages 54 and 55
Presentation (continued)
description
Presentation (continued)
Smart relay (Remote station)
The smart relay, as on an independent machine or installation, is used for control (1).
It contains the application program created using Zelio Soft 2 software.
The smart relay may be selected from the various models in the Zelio Logic range:
1 for all supply voltages,
1 with 10, 12, 20 or 26 I/O (up to 40 I/O with discrete extension module),
1 with or without display,
1 with clock.
The firmware version of the smart relay must be V3 or above.
Modem communication interface (Remote station)
The Modem communication interface allows messages, telephone numbers and
calling conditions to be stored.
When the calling conditions are met, the messages, as well as any values to be sent,
are date-stamped and stored in the interface.
The Modem communication interface scales analogue values to the physical values
(degrees, bar, Pascal, etc.) required by the user.
535523
Modems
Either GSM or analogue PSTN type Modems can be used on both the Remote
station and PC type Receiving devices (when the PC is not fitted with an internal
Modem).
GSM Modem
In order to exploit all the capabilities associated with Modem communication, the
Modem(s) must be fitted with DATA type SIM cards. VOICE type SIM cards may be
used but some functions will not be available. See table on page 49.
535522
GSM Modem
Zelio Logic Alarm alarm management software (PC type Receiving device)
This software makes it possible to:
1 receive, classify and export alarm messages,
1 read or remotely force the status of program elements (inputs, outputs, control
relays, timing or counting values, etc.),
1 send control instructions (RUN, STOP, setting the time of the smart relay, etc.),
1 send specific instructions (modifying access rights, recipients, etc.).
Description
The communication interface Zelio Logic SR2 COM01 comprises:
1
3
4
Functions, setting-up:
pages 48 and 49
Characteristics:
pages 50 and 51
References:
page 52
1
2
3
4
5
6
Dimensions:
page 53
Connections:
pages 54 and 55
47
Functions
Functions
Sending of alarms
This function makes it possible to send an alarm message to a Receiving device.
When the calling condition is met, a message is sent to one or several telephone
numbers or e-mail addresses.
Types of message:
1 alarm message to a PC with Modem and Zelio Logic Alarm software,
1 SMS message (1) to a GSM telephone,
1 e-mail via SMS (1) (2).
Receipt of instruction
This function allows the status or the value of a program element to be modified from
the Receiving device.
The operator initiates the call using the Receiving device (PC or GSM telephone). It
is then possible to force the status of the discrete and/or analogue value of each of
the 28 messages.
Presentation, description :
pages 46 and 47
48
Characteristics:
pages 50 and 51
References:
page 52
Dimensions:
page 53
Connections:
pages 54 and 55
Functions (continued),
setting-up
Functions available depending on the hardware architecture and/or type of SIM card
Function
VOICE
VOICE N
Functions available
Functions not available
Nota : Instructions cannot be transmitted by e-mail.
(1) When using a GSM Modem on the PC side, the SIM card must have a DATA number.
Installation set-up
Setting-up of the installation or the machine to be monitored involves 2 steps:
Connection for programming the smart relay and the interface
Communication
interface
Smart relay
SR2 COM01
PC
After having powered-up the smart relay and the interface, the application program
can be transferred in order to simultaneously:
1 load the automation system program into the smart relay,
1 load the alarm conditions, messages and telephone numbers/e-mail addresses
into the interface.
This operation can also be carried out remotely using Transfer mode, after having
made the operating connections described below.
is
Smart relay
SR2 COM01
Communication
interface
Smart relay
GSM Modem
SR2 COM01
2
1
2
3
4
1
3
GSM Modem
SR2 COM01
Presentation, description :
pages 46 and 47
Characteristics:
pages 50 and 51
References:
page 52
Dimensions:
page 53
Connections:
pages 54 and 55
49
Characteristics
SR2 COM01
UL, CSA, C-Tick
Conforming to 73/23/EEC
Conforming to 89/336/EEC
C
C
N.m
Supply characteristics
Interface type
Nominal voltage
Voltage limits
Maximum ripple
Nominal current
V
V
8 12 V
8 24 V
Current peak on power-up
Power dissipated
Micro-breaks
Protection
Presentation, description :
pages 46 and 47
50
Permissible duration
Integrated
To be provided externally
Functions, setting-up:
pages 48 and 49
mA
mA
mA
W
SR2 COM01
8 1224
8 1028.8
5%
30
30
550
1.1
1 ms. repeated 20 times
Against reversed polarity
1 A fuse
References:
page 52
SR2 MOD01
SR2 MOD02
8 1030
8 5.532
140
70
9600
1.7
125
60
2100 on 5.5 V
1.5
Dimensions:
page 53
Connections:
pages 54 and 55
Characteristics (continued)
Specific to Zelio
Type of link
Compatibility
Only with Zelio Logic smart relays SR1 B11111 and SR2 E11111 version V3.1 and above
Isolation of
Com-Z connector
By 6 1780 V opto-coupler
By 6 1780 V opto-coupler
Specific to Zelio
Isolation of
Com-M connector
AT commands
AT commands
Processing characteristics
Data saved by the interface
Messages
Up to 28 messages
Telephone/e-mail details
and recipient profiles
Date and time
Presentation, description :
pages 46 and 47
Functions, setting-up:
pages 48 and 49
References:
page 52
Dimensions:
page 53
Connections:
pages 54 and 55
51
References
523083
For
use with
SR B
SR2 E
2 22222
22222
Supply
Reference
8 1224 V
SR2 COM01
(1)
Supply
voltage
8 1224 V
Reference
8 1224 V
SR2 MOD02
(2)
Weight
kg
0.200
Modems
Description
Analogue PSTN Modem
Type SIXNET VT-MODEM-5-WW,
including a telephone cable
(length 2 m)
SR2 MOD01
Weight
kg
0.265
SR2 COM01
535522
GSM Modem
Type WAVECOM FASTRACK M1306 B
dual band 900/1800 Mhz,
including:
2 a supply cable
(length 1.5 m),
2 fixing lugs for plate mounting,
2 a SUB-D 9/SUB-D 15 cable
(length 0.5 m),
2 an antenna with cable
(length 2 m).
0.445
SR2 MOD01
Software
535523
Description
Zelio Logic Alarm
Application
Medium
Compatibility
PC
CD-ROM
Windows 98,
NT4, 2000 and XP
Reference
SR2 SFT02
Weight
kg
0.200
Reference
Weight
Connection accessories
Description
SR2 MOD02
Composition/
Application
Length
m
SUB-D9/SUB-D9 1.8
SR1 CBL03
connectors
Between modem
and PC
Specific
0.5
SR2 CBL07
Zelio/SUB-D9
(3)
connector
Between
communication
interface and
modem
(1) Can only be used with "Zelio Soft 2" software version 2 3.1.
(2) Not recommended for North America or Japan
(3) Spare part (cable included with communication interface SR2 COM01).
523086
Connection cables
SR2 CBL07
Presentation, description :
pages 46 and 47
52
Functions, setting-up:
pages 48 and 49
Characteristics:
pages 50 and 51
Dimensions:
page 53
Connections:
pages 54 and 55
kg
0.110
0.050
Dimensions
Communication interface
SR2 COM01
100
90
59,5
107,6
2 x 4
60
72
Modems
SR2 MOD01 (Analogue PSTN modem)
70
80,5
2 x 4
106
31
118
33
27
54,5
5 x 7
25,5
73
88
101,2
111
Presentation, description :
pages 46 and 47
Functions, setting-up:
pages 48 and 49
Characteristics:
pages 50 and 51
References:
page 52
Connections:
pages 54 and 55
53
Connections
Connection schemes for connecting communication interface SR2 COM01 to the smart relay and the
Modem
SR B
1 12 or 24 V
Input
connections
(1)
(1)
I1 I2 I3 I4 I5 I6 IB IC
12-24VDC
SR2 COM01
(2)
(3)
COM-Z
COM-M
COM-M
(4)
STATUS
GSM or Analogue
PSTN Modem
Q1
Q2
Q3
Q4
(4)
Output
connections
SR2 MOD01
or
SR2 MOD02
SR B
1 12...24 V
2 24 V or
2 100240 V
Input
connections
(1)
(1)
I1 I2 I3 I4 I5 I6 IB IC
+
12-24VDC
SR2 COM01
(2)
(3)
COM-Z
COM-M
(4)
STATUS
Analogue PSTN or
GSM modem
Q1
Q2
Q3
Q4
(4)
Output
connections
SR2 MOD01
or
SR2 MOD02
Presentation, description :
pages 46 and 47
54
Functions, setting-up:
pages 48 and 49
Characteristics:
page 50 and 51
References:
page 52
Dimensions:
page 53
Connections (continued)
Zelio
Logic
Alarm
1 12...24 V
(1)
Analogue PSTN
Modem
(1) Cable for connection to the Transmission network (included with analogue PSTN modem).
(2) To be ordered separately.
GSM Modem
1 12...24 V
Zelio
Logic
Alarm
Antenna
(2)
(1)
GSM Modem
(1) Cable included with the Modem (length: 50 cm). The cable length can be increased using SR1 CBL03 (1.8 m).
(2) Antenna and cable included with GSM Modem.
Presentation, description :
pages 46 and 47
Functions, setting-up:
pages 48 and 49
Characteristics:
page 50 and 51
References:
page 52
Dimensions:
page 53
55
Selection guide
Analogue interfaces
Zelio Analog
Converters for thermocouples and Pt100 probes
Voltage/current converters
Product types
Input type
J (Fe-CuNi)
K (Ni-CrNi)
Input signal
Temperature range
Voltage
0...150 C
32...302 F
0...300 C
32...572 F
0...600 C
32...1112 F
Current
Voltage/Current
Rated
Outputs
0... 600 C
32...1112 F
0...1200 C
32...2192 F
RMT K80 BD
RMT K90BD
Output signal
Supply voltage
Built-in protection
Supply
Signalling
Conformity/Approvals
Conforming to standards
Approvals
Type
RMT J40BD
Pages
62
56
RMT J60BD
RMT J80BD
Voltage/current converters
- 40...40 C
- 40...104 F
-100...100 C
- 148...212 F
0...100 C
32...212 F
0...250 C
32...482 F
0...500 C
32...932 F
0...10 V
4...20 mA
Switchable:
0... 10 V/0...20 mA , 4...20 mA for the Universal Pt100 range RMP T 0BD
0...10 V or 4...20 mA for the Optimum Pt100 range RMP T 3BD
0...10 V or
4...20 mA
0...10 V; 10 V 0...50 V;
0...300 V;
0...500 V
8 or6 50/60 Hz
0...20 mA;
0...1.5 A;
4...20 mA
0...5 A; 0...15 A
8 or 6 50/60 Hz
Switchable:
0...10 V; 10 V/
0...20 mA;
4...20 mA
Switchable:
0...10 V/
4...20 mA;
0...20 mA
0...10 V or
0...20 mA or
4...20 mA
RMP T11BD
RMP T21BD
IEC 60947-1
RMP T31BD
RMP T51BD
RMP T71BD
RMC V60BD
RMC A61BD
62
57
Presentation
Analogue interfaces
Zelio Analog
Converters for thermocouples and Pt100 probes
Voltage/current converters
Presentation
The Zelio Analog range
The Zelio Analog range has been developed both to take account of the most
common applications and to ensure great simplicity of installation:
1 pre-set input and output scales, requiring no adjustment
1 outputs protected against reverse polarity, overvoltage and short-circuits
1 5 24 V power supply
1 sealable protective cover
1 rail mounting and screw fixing onto mounting plate
1 LED indicator on the front panel
1 input and output selector switches on the front panel
1 output with fallback value if no input signal is present (due to failure of a sensor,
for example).
108997
108999
RMT J40BD
Characteristics :
pages 60 and 61
58
RMT K90BD
References :
page 62
Dimensions :
page 63
Schemes :
page 63
Presentation (continued)
Analogue interfaces
Zelio Analog
109000
RMP T70BD
109002
RMC A61BD
108998
Description
Zelio Analog converters have the following on their front panel, depending on the
model:
1 Two terminals for 5 24 V supply connection
2 A 'Power ON' LED
3 Three input selector switches (depending on model)
4 An output selector switch (depending on model)
5 A sealable protective cover
6 A screw terminal block for inputs
7 A screw terminal block for outputs.
4
5
6
7
RMC L55BD
Characteristics :
pages 60 and 61
References :
page 62
Dimensions :
page 63
Schemes :
page 63
59
Characteristics
Analogue interfaces
Zelio Analog
Converters for thermocouples and Pt100 probes
Voltage/current converters
Environment characteristics
22222
Converter types
Conforming to standards
Product certifications
Degree of protection
22222
22222
RMT J/K
, RMP
, RMC
IEC 60947-1, IEC 60584-1 (IEC 60751, DIN 43760 for RMP1111)
UL, CSA, GL, 9
Housing
Terminal block
Flame resistance
Shock resistance
Vibration resistance
Immunity to EMC
Resistance to electrostatic discharge
Immunity to fast transient currents
Surge withstand
IP 50
IP 20
850 conforming to UL, IEC 60695-2-1
50 gn/11 ms conforming to IEC 68-2-27
5 gn (10...100 Hz) conforming to IEC 68-2-6
kV
kV
kV
kV
Disturbance
Radiated/conducted
Insulation voltage
Ambient air temperature around the device
Storage
Operation
Degree of pollution
Mounting
Connection
Tightening torque
C
C
mm2
Nm
-40...85 (-40...185 F)
Mounted side-by-side: 0...50 (32...122 F); 2 cm spacing: 0...60 (32...140 F)
2 conforming to IEC 60664-1
35 mm DIN rail, clip-on or fixed on mounting plate
2 x 1.5 or 1 x 2.5 cable
0.6...1.1
C
F
RMT J40BD
J (Fe-CuNi)
0...150
32...302
Specific characteristics
Types of converter for thermocouples
Input types
Thermocouple type to IEC 60584
Temperature range
Analogue output switchable to voltage or current
Voltage
Range
Minimum impedance of load
Current
Range
Maximum impedance of load
Built-in protection
Safety
Output state when no inputs are wired
or when input wire broken
Built-in protection
Signalling
Measurements
Accuracy
At 20 C
60
References :
page 62
0...600
32...1112
24 20 %, non isolated
40
60
Reverse polarity
Green LED (power on)
8V
Presentation :
pages 58 and 59
0...300
32...572
RMT K80BD
K (Ni-CrNi)
0...600
32...1112
0...10
100
0...20 ; 4...20
500
Reverse polarity, overvoltage ( 30 V) and short-circuit
Output predetermined according to type of output selected:
voltage = - 13 V
current = 0 mA
Rated
For voltage output
For current output
At 20 C
At 60 C
Temperature coefficient
Cold junction compensation
RMT J80BD
V
k
mA
Supply
Voltage
Maximum current
consumption
Repeat accuracy
RMT J60BD
mA
mA
RMT K90BD
0...1200
32...2192
Dimensions :
page 63
Schemes :
page 63
Characteristics (continued)
Analogue interfaces
Zelio Analog
Converters for thermocouples and Pt100 probes
Voltage/current converters
C
F
Analogue output
Output selection
Voltage
Current
Built-in protection
Safety
Supply
Voltage
Maximum current
consumption
Rated
For voltage output
For current output
8V
Built-in protection
Signalling
Measurements
Accuracy
At 20 C
Repeat accuracy
At 20 C
At 60 C
Temperature coefficient
Connection in 2-wire mode
Maximum resistance of cable
mA
mA
RMP T10/13BD RMP T20/23BD RMP T30/33BD RMP T50/53BD RMP T70/73BD
Pt100 - IEC 60751; DIN 43760 (2, 3, 4-wire)
- 40...40
- 100...100
0...100
0...250
0...500
- 40...104
- 148...212
32...212
32...482
32...932
0...10 V/0...20 mA, 4...20 mA switchable for RMP T10BD
0...10 V or 4...20 mA for RMP T13BD
100
500
Reverse polarity, overvoltage ( 30 V) and short-circuit
Output predetermined according to type of output selected:
voltage = - 13 V
current = 0 mA
24 20 %, non isolated
40
60
Reverse polarity
Green LED (power on)
200
RMC N22BD
870...10
RMC L55BD
870...10, 10
Current
mA
A
4...20
0...20 ; 4...20
Range
Minimum impedance of load
Range
Maximum impedance of load
V
k
mA
Specific characteristics
Types of voltage/current converters
Input types
Voltage
Analogue output
Output selection
Voltage
Current
Built-in protection
Safety
Supply
Voltage
Maximum current
consumption
Built-in protection
Signalling
Measurements
Accuracy
Rated
For voltage output
For current output
mA
mA
At 20 C
Repeat accuracy
At 20 C
At 60 C
Temperature coefficient
Presentation :
pages 58 and 59
References :
page 62
RMC V60BD
0...50; 0...300;
0...500
8 or 6 50/60 Hz
RMC A61BD
By cabling
Switchable
Switchable
By cabling
0...10
0...10; 10
0...10
0...10
100
4...20
0...20; 4...20
0...20; 4...20
0...20 4...20
500
Reverse polarity, overvoltage ( 30 V) and short-circuit
Output predetermined according to type of output selected:
voltage:
voltage:
voltage: < 0 V
<0V
- 10+ 10 V: -10 V current:
current:
0+ 10 V : 0 V
020 mA : 0 mA
< 4 mA
current:
420 mA : < 4 mA
020 mA : 0 mA
420 mA : 4 mA
8 24 20 %
non isolated
40
70
60
90
Reverse polarity
Green LED (power on)
Dimensions :
page 63
Schemes :
page 63
61
References
Analogue interfaces
Zelio Analog
108999
108997
RMT K90BD
109000
RMT J40BD
Type K
Temperature range
C
F
0150
32302
0300
32572
0600
321112
0600
321112
01200
322192
Switchable
output signal
Reference
RMT J40BD
Weight
kg
0.120
RMT J60BD
0.120
RMT J80BD
0.120
RMT K80BD
0.120
RMT K90BD
0.120
Temperature range
C
F
- 4040
- 40104
Pt100
2-wire, 3-wire
and 4-wire
- 100100
RMP T70BD
- 148212
0100
32212
0250
32482
0500
32932
Switchable
output signal
Reference
RMP T10BD
Weight
kg
0.120
RMP T20BD
0.120
RMP T30BD
0.120
RMP T50BD
0.120
RMP T70BD
0.120
109001
Temperature range
C
F
- 4040
- 40104
Weight
kg
0.120
0.120
0100
32212
0.120
0250
32482
0.120
0500
32932
0.120
Pt100
2-wire, 3-wire
and 4-wire
- 100100
RMP T13BD
Output signal
Reference
108996
Output signal
010 V or 420 mA
Reference
Weight
kg
0.120
RMC N22BD
Reference
Switchable:
RMC L55BD
010 V, 10 V,
020 mA, 420 mA
Switchable:
RMC V60BD
010 V, 0...20 mA,
420 mA
010 V or 0...20 mA RMC A61BD
or 420 mA
109002
108998
Output signal
01.5 A, 05 A, 015 A
8 or 6 50/60 Hz
Weight
kg
0.120
0.150
0.150
Connection accessories
Description
RMC L55BD
Presentation :
pages 58 and 59
62
RMC A61BD
Characteristics :
pages 60 and 61
Type
Sold in lots of
Dimensions :
page 63
Schemes :
page 63
Unit reference
Weight
kg
AB1 RRTP435U
0.025
AB1 RRTP435U2
0.015
Analogue interfaces
Dimensions,
mounting,
schemes
Zelio Analog
1
Dimensions, mounting
(1)
Panel mounting
2x4
78
78
(1)
25
80
90
RMT
90,5
45
31
90,5
83
51
Schemes
RMT J
RMP T 0BD
RMP T 3BD
2 mA
Vo
A1
(+) IP2
() IP1
A2
A1
IP2
IP3
IP4
IP2
IP3
IP4
Vo
OPG
OPG
A2
0V
22222
3-wire type
RL1 = RL2 = RL3
RL1 + RL2 200
RL1
IP1
4-wire type
RL1 + RL2 200
IP1
IP2
IP2
IP3
IP3
IP4
22222
RMC
RMC N22BD
RL2
IP4
RL3
IP3
RMC L55BD
A1
Vo
A2
1930 V
(1)
OPG
A2
V
0V
(1)
IP4
RL1
IP1
A1
0V
Vi
I
RL2
RMC V60BD
1930 V
A1
Ii
IPG
Io
OPG
IP2
RL2
(1)
(1)
Vo
A2
c0V
0V
420 mA
1930 V
IP1
A1
1930 V
Type
J or K
2 mA
c 1930 V
IP1
Ii
IPG
Vo
OPG
A2
1930 V
(1)
(1)
(1)
0V
V1
V2
V3
IPG
Vo
OPG
1930 V
A1
Vi
IPG
010 V
Io
OPG
A2
0V
RMC A61BD
A1
A2
1930 V
0V
(1)
(1)
(1)
I1
I2
I3
Icom
Vo
Io1
Io2
OPG
Presentation :
pages 58 and 59
Characteristics :
pages 60 and 61
(2)
(2)
(2)
1 The input, output and power supply lines must be kept away from the power
cables to avoid effects due to induced interference.
The input and output cables must be shielded as indicated in the schemes and must
be kept away from each other.
References :
page 62
63
Presentation,
description
ABL 8MEM11111
The ABL 8MEM/7RM power supply offer is designed to provide the DC voltage
necessary for the control circuits of automation system equipment consuming
8 7 to 60 W at 5, 12 and 24 V. Comprising six products, this range meets the needs
encountered in industrial, commercial, and residential applications. These modular
electronic switch mode power supplies provide a quality of output current that is
suitable for the loads supplied and compatible with the Zelio Logic range. Clear
guidelines are given on selecting the upstream protection devices which are often
used with them, and thus a comprehensive solution is provided that can be used in
total safety.
Modular Phaseo power supplies can be connected between phase and neutral
(N-L1) or between two phases (1) (L1-L2). They deliver a voltage that is precise
to 3%, whatever the load and whatever the type of line supply, within a range of
6 85 to 264 V. Conforming to IEC standards and UL, CSA and TUV certified, they
are suitable for universal use. The inclusion of overload and short-circuit protection
makes downstream protection unnecessary if discrimination is not required.
Due to their low power, Modular Phaseo power supplies consume very little harmonic
current and thus are not subject to the requirements of standard 61000-3-2
concerning harmonic pollution.
All Modular Phaseo power supplies have protection devices to ensure optimum
performance of the automation system with an automatic reset mode on elimination
of the fault.
These power supplies also have a cable run inside the unit so that the outputs can
be connected at the top or bottom of the product as required.
These power supplies are designed for direct mounting on 35 mm
rails, or on a
mounting plate using the retractable fixing lugs.
There are six references available in the Modular Phaseo range :
1 ABL8MEM24003
7W
300 mA
1 ABL8MEM24006
15 W
600 mA
1 ABL8MEM24012
30 W
1.2 A
1 ABL7RM24025
60 W
2.5 A
1 ABL8MEM05040
20 W
4A
1 ABL8MEM12020
25 W
2A
5 24 V
5 24 V
5 24 V
5 24 V
5 5V
5 12 V
Description
ABL 8MEM1111
7
ABL7RM24025
5
4
6
2
64
Characteristics
Technical characteristics
Power supply type
Certifications
Conforming to standards
ABL 8MEM24003
ABL 8MEM24006
ABL 8MEM24012
ABL 7RM24025
cULus 508, cCSAus (CSA22.2 n950-1), TUV 60950-1, 9, CTick
IEC/EN 60950-1, TBTS
IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61204-3, EN 55022 Class B
Safety
EMC
Input circuit
LED indication
Input values
No
Nominal voltage
Permissible voltage
V
V
Current consumption
Permissible frequencies
Max. current at switch-on
Power factor
Efficiency at nominal load
Dissipated power at nominal
load
Hz
A
Voltage (Uout)
Current
Power
Output voltage
Line and load regulation
Residual ripple - interference
UIn min. = 6 100 V
UIn min. = 6 230 V
Against short-circuits
Against undervoltage
Thermic
V
A
W
V
6 100240
6785264
87120250 (1)
0.25 (6 100 V)
0.18 (6 240 V)
4763
20
> 0.5
> 78%
2
6785264
0.4 (6 100 V)
0.25 (6 240 V)
0.65 (6 100 V)
0.4 (6 240 V)
1.2 (6 120 V)
0.7 (6 240 V)
90 during 1 ms
> 80%
3.8
> 82%
6.6
> 84%
11.4
1.2
30
2.5
60
Output circuit
LED indication
Nominal output values
Precision
Holding time
for I max.
Protections
mV
ms
ms
V
Green LED
8724
0.3
0.6
7
15
Ajustable from 22.8 to 28.8
3%
250
5 10
5 150
Permanent
Yes
200
< 19
Input
Output
On vertical plan
Series
Parallel
Operating temperature
Storage temperature
Maximum relative humidity
Degree of protection
Vibrations
Protection class conforming to VDE 0106 1
Dielectric strength 50 Hz
Input/output
during 1 min
Input fuse incorporated
Emission,
according to EN 61000-6-3
Radiation
Conducted on the power line
Harmonic currents
Immunity,
according to EN 61000-6-2
Electrostatic discharge
Radiated electromagnetic fields
Induced electromagnetic fields
Rapid transients
Surges
Primary outages
mm2
mm2
IEC/EN 61000-4-2
(4 kV contact/8 kV air)
Presentation:
page 64
References:
page 69
Dimensions:
page 69
Schemes:
page 69
65
Characteristics (continued)
Technical characteristics
Power supply type
Certifications
Conforming to standards
ABL 8MEM05040
ABL 8MEM12020
cULus 508, cCSAus (CSA22.2 n950-1), TUV EN 60950-1, 9, CTick
IEC/EN 60950-1, TBTS
IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61204-3, EN 55022 Class B
Safety
EMC
Input circuit
LED indication
Input values
No
Nominal voltage
Permissible voltage
V
V
Current consumption
Permissible frequencies
Max. current at switch-on
Power factor
Efficiency at nominal load
Dissipated power at nominal
load
Hz
A
Voltage (Uout)
Current
Power
Output voltage
Line and load regulation
Residual ripple - interference
UIn min.
V
A
W
V
6 100240
6785264 V
87120250 V (1)
0.55 (6 100 V)
0.35 (6 240 V)
0.6 (6 100 V)
0.35 (6 240 V)
4763
20
> 0.5
> 75%
6.7
> 80%
6.2
Output circuit
LED indication
Nominal output values
Precision
Holding time
for I max.
Protections
mV
ms
Against short-circuits
Against undervoltage
Thermic
Green LED
875
4
20
Adjustable from 4.75 to 6.25
3%
250
5 10
8712...15
2.1
25
Ajustable from 11.4 to 15.5
Permanent
Input
Output
On vertical plan
Series
Parallel
Operating temperature
Storage temperature
Maximum relative humidity
Degree of protection
Vibrations
Protection class conforming to VDE 0106 1
Dielectric strength 50 Hz
Input/output
during 1 min
Input fuse incorporated
Emission,
according to EN 61000-6-3
Radiation
Conducted on the power line
Harmonic currents
Immunity,
according to EN 61000-6-2
Electrostatic discharge
Radiated electromagnetic fields
Induced electromagnetic fields
Rapid transients
Surges
Primary outages
mm2
mm2
Description:
page 64
66
References:
page 69
Dimensions:
page 69
Schemes:
page 69
Characteristics (continued)
Output characteristics
Comportement sur courts-circuits et surcharges applicatives
The Phaseo power supplies are equipped with an electronic protection device.
On overload or short-circuit, the integrated protection stops the supply of current
before that the output voltage drops below 19 V.
The output voltage regains its nominal value on elimination of fault thus avoided any
intervention.
Derating
The ambient temperature is a determining factor which limits the power that an
electronic power supply can deliver continuously. If the temperature around the
electronic components is too high, their life will be significantly reduced.
The maximum ambient temperature for Phaseo power supplies is 55 C. Above this
temperature, derating is necessary up to a maximum temperature of 70 C max.
(except model ABL 7RM24025).
The graph below shows the power (in relation to the nominal power) that the power
supply can deliver continuously, according to the ambient temperature.
P/Pn (%)
100 %
30 %
- 25
-5
15
35
55
70
75
+
(1)
ABL 7RM
ABL 8MEM
ABL 7RM
ABL 8MEM
ABL 7RM
ABL 8MEM
ABL 7RM
ABL 8MEM
Parallel connection
(1)
2x
1 24 V/2 x I out
1 24 V/I out
Description:
page 64
References:
page 69
Dimensions:
page 69
Schemes:
page 69
67
Associations
Single-phase
100 to 240 V
Thermal-magnetic circuit-breaker
GB2 (IEC) (1)
C60N (IEC)
C60N (UL/CSA)
GB2 1107 (2)
24581
24517
ABL 8MEM05040
ABL 8MEM12020
ABL 8MEM24003
ABL 8MEM24006
ABL 8MEM24012
ABL 7RM24025
Fuse gG
2A
24582
24518
3A
(1) UL pending.
(2) Complete the reference 11 by :
- CB : for single-pole circuit-breaker with magnetic opening threshold 12 to 16 In.
- CD : for 1 pole protected and 1 pole switched circuit-breaker with magnetic opening threshold
12 to 16 In.
- DB : for 2-pole circuit-breaker with magnetic opening threshold 12 to 16 In.
- CS : for single-pole circuit-breaker with magnetic opening threshold 5 7 In.
68
3/L2
22
GB2 CS
1/L1
1/L1
GB2 DB
4/T2
1/L1
2/T1
Characteristics :
pages 65 to 67
22
2/T1
3/L2 (13)
2/T1
Description:
page 64
GB2 CD
4/T2 (14)
22
1/L1
GB2 CB
2/T1
22
References,
dimensions,
internal schemes
Secondary
Output
Nominal
voltage
power
Reset
Nominal
current
Conforming
to standard
EN 61000-3-2
(1)
Reference
No applicable
ABL 8MEM05040
0.195
No applicable
ABL 8MEM12020
0.195
ABL 8MEM24003
7
ABL 8MEM24006
7
ABL 8MEM24012
7
0.100
ABL 8MEM05040/12020/24012
8 24 V
7W
0.3 A
Automatic
No applicable
15 W
0.6 A
Automatic
No applicable
30 W
1.2 A
Automatic
No applicable
60 W
2.5
Automatic
No applicable
Weight
kg
ABL 7RM24025
0.100
0.195
0.255
ABL 8MEM24003/24006
Description
Clip-on labels
Used
100
LAD 90
Weight
kg
0.030
Dimensions
ABL 8MEM
a
54
54
36
36
54
72
a1
42
42
24
24
42
60
90
100
110
ABL 8MEM05040
ABL 8MEM12020
ABL 8MEM24003
ABL 8MEM24006
ABL 8MEM24012
ABL 7RM24025
44
59
a1
a
Internal schemes
Description:
page 64
+
+
ABL 8MEM05040/8MEM12020/8MEM24012/7RM24025
ABL 8MEM24001
Characteristics:
pages 65 to 67
69
A worldwide presence
Constantly available
1 More than 5 000 points of sale in 130 countries.
1 You can be sure to find the range of products that are right for you and which
complies fully with the standards in the country where they are used.
Technical assistance wherever you are
1 Our technicians are at your disposal to assist you in finding the optimum
solution for your particular needs.
1 Schneider Electric provides you with all necessary technical assistance,
throughout the world.
ART. 808501
www.telemecanique.com
Simply Smart !
Due to evolution of standards and equipment, the characteristics indicated in texts and images of this
document do not constitute a commitment on our part without confirmation.
Design: Schneider Electric
Photos: Schneider Electric
Printed by:
11 / 2006 - V2.0
DIA3ED2051002EN