Lead Free TypeTHHN/THWN-2 600 Volts for 90oC Dry & Wet Locations

APPLICATIONS
Type THHN/THWN-2 conductors
are primarily used in conduit for
services, feeder, and branch
circuits in commercial or industrial
applications as specified in the
Philippine Electrical Code (PEC) &
National Electrical Code (NEC).
When used as type THHN/THWN2, conductors are suitable for use
in wet or dry locations at
o
temperatures not to exceed 90 C
both dry and wet locations or not to
o
exceed 75 C exposed to oil or
coolant.
2

For 50mm 500mm , Cable tray


(CT) rated THHN/THWN-2 can be
installed in Cable Trays.

DESCRIPTION
Type THHN/THWN-2 is single
insulated conductor of solid or
stranded bare annealed high
conductivity
copper,
with
thermoplastic Lead free insulation
of PVC (Polyvinyl Chloride) and
protected by a nylon jacket;
designed to operate up to 600 volts
AC.

SPECIFICATIONS
The THHN/THWN-2 conductors
are designed according to local
and internationally recognized and
accepted standards:

ASTM: B3, B8

Underwriters
Laboratory:
Listed under file # E-55448 for
AWG Conductor sizes.

UL:83 Specification

PNS: 35 Specification

PEC
2000
Article
3.18
compliant for Cable tray

NEC Article 318 compliant for


Cable tray

CHARACTERISTICS AND
SPECIAL FEATURES

Designed to operate at a
maximum
conductor
o
temperature of 90 C both for
wet and dry locations.
Higher cable ampacity.
Available in six standard
colors (red, black, white,
green, yellow and blue).

Copper
Equivalent Conductor
AWG size Diameter

PNS
Size

Overall
Approx
Cable Cable w eight
Diameter
mm
kgs/km
2.6
22
3.0
33
3.8
55
5.1
88

Cable Ampacity++ Effective Impedance +++


Minimum
Dry and Wet Ohm to neutral per 305 M Bending
Locations
3 conductors in
Raduis
at 75oC/90oC
PVC
Steel 8 x Cable OD
Amperes
Conduit
Conduit
mm
25+
2.7
2.7
21
30+
1.7
1.7
24
40+
1.1
1.1
30
55
0.69
0.7
41

Standard
Packaging
Scheme

1.6 mm Sol
2.0 mm Sol
2.6 mm Sol
3.2 mm Sol

14 AWG
12 AWG
10 AWG
8 AWG

mm
1.6
2.0
2.6
3.2

2.0 mm2 Str


3.5 mm2 Str
5.5 mm2 Str
8.0 mm2 Str

14 AWG
12 AWG
10 AWG
8 AWG

1.8
2.3
2.9
3.6

2.8
3.3
4.1
5.5

24
37
58
96

25+
30+
40+
55

2.7
1.7
1.1
0.69

2.7
1.7
1.1
0.7

22
26
33
44

150m per box


150m per box
150m per box
100m per box

14 mm2 Str
22 mm2 Str
30 mm2 Str

6 AWG
4 AWG
2 AWG

4.6
5.7
6.7

6.5
8.1
9.0

147
232
311

70
90
115

0.44
0.29
0.19

0.45
0.3
0.2

52
64
72

150m per coil


150m per coil
150m per coil

38 mm2 Str
50 mm2 Str
60 mm2 Str
80 mm2 Str
100 mm2 Str

1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG

7.8
8.8
9.8
11.2
12.7

10.8
11.8
12.7
14.2
15.7

414
514
625
813
1,026

130
150
170
205
225

0.16
0.13
0.11
0.088
0.074

0.16
0.13
0.11
0.094
0.08

86
94
102
114
125

300 m per reel


300 m per reel
300 m per reel
300 m per reel
300 m per reel

125 mm2 Str


150 mm2 Str
175 mm2 Str
200 mm2 Str
250 mm2 Str

250 MCM
300 MCM
350 MCM
400 MCM
500 MCM

14.3
15.7
17.0
17.8
20.2

17.8
19.3
20.8
21.4
23.8

1,298
1,556
1,741
1,967
2,519

265
295
325
355
400

0.066
0.059
0.054
0.049
0.045

0.073
0.065
0.06
0.056
0.05

142
155
166
171
191

300 m per reel


300 m per reel
300 m per reel
300 m per reel
300 m per reel

300 mm2 Str


325 mm2 Str
375 mm2 Str
400 mm2 Str
500 mm2 Str

600 MCM
650 MCM
750 MCM
800 MCM
1000 MCM

22.3
22.9
25.0
25.5
28.2

26.9
26.9
29.6
29.7
32.2

2,964
3,218
3,677
3,974
4,809

447
470
500
515
580

0.042
0.04
0.037
0.036
0.032

0.048
0.047
0.044
0.043
0.04

215
215
237
237
258

300 m per reel


300 m per reel
300 m per reel
300 m per reel
300 m per reel

150m per box


150m per box
150m per box
100m per box

+Unless otherwise specifically permitted the over current protection shall both exceed 15 amperes for
2
2
2
2.0mm (1.6mm); 20 Amperes for 3.5mm (2.0mm) and 25 Amperes for 5.5mm as per PEC.
o
++Ampacity Based on 90 C not more than three current carrying conductors in conduit based on ambient
o
temperature of 30 C as PEC 2000.
o
+++Effective Impedance for three conductors in conduit 60 HZ, 75 C and 600 Volts at P.F. Multiplying
current by effective impedance gives a good approximation for line to neutral voltage drop.

Jacketed with nylon for mechanical


protection; greater resistance against
abrasion, resistance to petroleum byproducts, chemical agents and oils,
and termite resistant.
With sequential cable marker printed
on the cable surface for sizes 50mm2
2
up to 500mm to indicate the length of
the cable, act as cable usage
reference and for inventory control.
General Manager:

INSTALLATION
THHN/THWN-2 conductors can be installed
2
as follows: in conduit & raceways for 2.0mm
2
up to 500mm , or in cable trays for sizes
2
50mm up to 500mm2. It is important that the
installation instructions indicated by the
Philippine Electric Code, or National Electrical
Code, be followed to safeguard the safety of
people installing the product and eliminate
damage to the product due to improper
installation.