Professional Documents
Culture Documents
ACS714 Datasheet PDF
ACS714 Datasheet PDF
Description
Typical Application
+5 V
1
2
IP
IP+
VCC
IP+ VIOUT
8
7
VOUT
CBYP
0.1 F
ACS714
3
4
IP FILTER
IP
GND
6
5
CF
1 nF
ACS714-DS, Rev. 9
ACS714
Description (continued)
the conductive path are electrically isolated from the signal leads
(pins 5 through 8). This allows the ACS714 to be used in applications
requiring electrical isolation without the use of opto-isolators or
other costly isolation techniques.
The ACS714 is provided in a small, surface mount SOIC8 package.
Selection Guide
Part Number
Optimized Range, IP
(A)
Sensitivity, Sens
(Typ) (mV/A)
ACS714ELCTR-05B-T
185
ACS714ELCTR-20A-T
20
100
ACS714ELCTR-30A-T
30
66
ACS714LLCTR-05B-T
185
ACS714LLCTR-20A-T
20
100
ACS714LLCTR-30A-T
30
66
ACS714LLCTR-50A-T
50
40
TA
(C)
Packing*
40 to 85
Tape and reel, 3000 pieces/reel
40 to 150
Symbol
Notes
Rating
Units
Supply Voltage
VCC
VRCC
0.1
Output Voltage
VIOUT
VRIOUT
0.1
IIOUT(Source)
mA
IIOUT(Sink)
10
mA
IP
TA
1 pulse, 100 ms
100
Range E
40 to 85
Range L
40 to 150
TJ(max)
165
Tstg
65 to 170
Isolation Characteristics
Characteristic
Symbol
Notes
Rating
Unit
2100
VAC
VISO
VWFSI
354
VDC or Vpk
VWFRI
184
VDC or Vpk
* Allegro does not conduct 60-second testing. It is done only during the UL certification process.
TV America
Certificate Number:
U8V 06 05 54214 010
Parameter
Specification
ACS714
Hall Current
Drive
IP+
(Pin 1)
Sense Temperature
Coefficient Trim
Dynamic Offset
Cancellation
IP+
(Pin 2)
IP
(Pin 3)
Signal
Recovery
VIOUT
(Pin 7)
RF(INT)
Sense
Trim
IP
(Pin 4)
0 Ampere
Offset Adjust
GND
(Pin 5)
FILTER
(Pin 6)
Pin-out Diagram
IP+
VCC
IP+
VIOUT
IP
FILTER
IP
GND
Name
1 and 2
IP+
Description
3 and 4
IP
GND
FILTER
VIOUT
VCC
ACS714
COMMON OPERATING CHARACTERISTICS1 over full range of TA , CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
Units
4.5
5.0
5.5
10
13
mA
ELECTRICAL CHARACTERISTICS
Supply Voltage
VCC
Supply Current
ICC
CLOAD
VIOUT to GND
10
nF
RLOAD
VIOUT to GND
4.7
RPRIMARY
TA = 25C
1.2
tr
3.5
kHz
80
Nonlinearity
ELIN
1.5
Symmetry
ESYM
98
100
102
Bidirectional; IP = 0 A, TA = 25C
VCC
0.5
35
12
G/A
VIOUT(Q)
tPO
Magnetic Coupling2
Internal Filter Resistance3
RF(INT)
1.7
1Device
may be operated at higher primary current levels, IP, and ambient, TA , and internal leadframe temperatures, TA , provided that the Maximum
Junction Temperature, TJ(max), is not exceeded.
21G = 0.1 mT.
3R
F(INT) forms an RC circuit via the FILTER pin.
TA
Min.
Typ.
Max.
E range
40
85
Units
C
L range
40
150
Value
Units
RJL
C/W
RJA
Mounted on the Allegro 85-0322 evaluation board, includes the power consumed by the board
23
C/W
1Additional
2The Allegro
ACS714
x05B PERFORMANCE CHARACTERISTICS1 over Range E: TA = 40C to 85C, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Test Conditions
Min.
Typ.
Max.
180
185
190
mV/A
21
mV
mV/C
IP
Sens
Units
TA = 40C to 25C
0.26
TA = 25C to 150C
0.08
mV/C
TA = 40C to 25C
0.054
mV/A/C
TA = 25C to 150C
VOE
IP = 0 A
ETOT
IP =5 A, TA = 25C
0.008
mV/A/C
40
40
mV
1.5
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature, TJ(max),
is not exceeded.
2Percentage of I , with I = 5 A. Output filtered.
P
P
x05B PERFORMANCE CHARACTERISTICS1 over Range L: TA = 40C to 150C, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Electrical Output Voltage
Total Output Error2
Test Conditions
Min.
Typ.
Max.
185
mV/A
21
mV
mV/C
IP
Sens
VOE
ETOT
Units
TA = 40C to 25C
0.26
TA = 25C to 150C
0.08
mV/C
TA = 40C to 25C
0.054
mV/A/C
TA = 25C to 150C
0.008
mV/A/C
60
60
mV
IP =5 A, TA = 25C
1.5
IP =5 A, TA = 40C to 150C
IP = 0 A
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature, TJ(max),
is not exceeded.
2Percentage of I , with I = 5 A. Output filtered.
P
P
ACS714
x20A PERFORMANCE CHARACTERISTICS over Range E: TA = 40C to 85C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Test Conditions
Min.
Typ.
Max.
20
20
96
100
104
mV/A
11
mV
mV/C
IP
Sens
Units
TA = 40C to 25C
0.34
TA = 25C to 150C
0.07
mV/C
TA = 40C to 25C
0.017
mV/A/C
TA = 25C to 150C
VOE
IP = 0 A
ETOT
IP = 20 A, TA = 25C
0.004
mV/A/C
30
30
mV
1.5
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of I , with I = 20 A. Output filtered.
P
P
x20A PERFORMANCE CHARACTERISTICS over Range L: TA = 40C to 150C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Electrical Output Voltage
Total Output Error2
Test Conditions
Min.
Typ.
Max.
20
20
100
mV/A
IP
Sens
VOE
ETOT
Units
94
104
mV/A
11
mV
mV/C
TA = 40C to 25C
0.34
TA = 25C to 150C
0.07
mV/C
TA = 40C to 25C
0.017
mV/A/C
TA = 25C to 150C
0.004
mV/A/C
40
40
mV
IP = 20 A, TA = 25C
1.5
IP = 20 A, TA = 40C to 150C
IP = 0 A
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of I , with I = 20 A. Output filtered.
P
P
ACS714
x30A PERFORMANCE CHARACTERISTICS over Range E: TA = 40C to 85C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Test Conditions
Min.
Typ.
Max.
30
30
64
66
68
mV/A
mV
mV/C
IP
Sens
Units
TA = 40C to 25C
0.35
TA = 25C to 150C
0.08
mV/C
TA = 40C to 25C
0.007
mV/A/C
TA = 25C to 150C
VOE
IP = 0 A
ETOT
IP = 30 A , TA = 25C
0.002
mV/A/C
30
30
mV
1.5
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of I , with I = 30 A. Output filtered.
P
P
x30A PERFORMANCE CHARACTERISTICS over Range L: TA = 40C to 150C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Electrical Output Voltage
Total Output Error2
Test Conditions
Min.
Typ.
Max.
30
30
66
mV/A
IP
Sens
VOE
ETOT
Units
63
69
mV/A
mV
mV/C
TA = 40C to 25C
0.35
TA = 25C to 150C
0.08
mV/C
TA = 40C to 25C
0.007
mV/A/C
TA = 25C to 150C
0.002
mV/A/C
40
40
mV
IP = 30 A , TA = 25C
1.5
IP = 30 A , TA = 40C to 150C
IP = 0 A
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of I , with I = 30 A. Output filtered.
P
P
ACS714
x50A PERFORMANCE CHARACTERISTICS over Range L: TA = 40C to 150C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Optimized Accuracy Range
Sensitivity
Symbol
Sens
Noise
VNOISE(PP)
VOUT(Q)
Sensitivity Slope
Electrical Output Voltage
Total Output Error2
Test Conditions
IP
Sens
VOE
ETOT
Min.
Typ.
Max.
50
50
Units
A
40
mV/A
37.5
42.5
mV/A
4.5
mV
mV/C
TA = 40C to 25C
0.35
TA = 25C to 150C
0.08
mV/C
TA = 40C to 25C
0.007
mV/A/C
TA = 25C to 150C
0.002
mV/A/C
IP = 0 A, TA = 25C
40
40
mV
IP = 40 A , TA = 25C
1.5
IP = 40 A , TA = 40C to 150C
1Device
may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of I , with I = 40 A. Output filtered.
P
P
ACS714
Characteristic Performance
IP = 5 A, unless otherwise specified
10.30
10.25
10.20
10.15
10.10
10.05
10.00
9.95
9.90
9.85
9.80
9.75
-50
VCC = 5 V
10.6
10.5
10.4
10.3
10.2
10.1
-25
25
50
75
100
125
10.0
4.5
150
4.6
4.7
4.8
4.9
TA (C)
2.0
ELIN (%)
IOM (mA)
1.5
VCC = 5 V; IP = 0 A,
After excursion to 20 A
2.5
3.0
5.5
VCC = 5 V
0.4
0.3
0.2
3.5
4.0
0.1
4.5
5.0
-50
-25
25
50
75
100
125
0
50
150
25
25
TA (C)
186.5
186.0
185.5
185.0
184.5
184.0
183.5
183.0
182.5
182.0
181.5
181.0
50
Sens (mV/A)
6
4
2
0
2
4
6
25
25
75
50
100
125
150
25
25
TA (C)
125
150
75
50
100
125
150
TA (C)
200.00
190.00
3.5
Sens (mV/A)
VCC = 5 V
3.0
2.5
TA (C)
40
25
85
150
2.0
1.5
1.0
180.00
170.00
160.00
TA (C)
40
25
85
150
150.00
140.00
130.00
120.00
0.5
110.00
0
7 6 5 4 3 2 1 0
100.00
-6
-4
-2
IP (A)
0
Ip (A)
2520
0.20
2515
0.15
IP = 0 A
2505
2500
0.05
0
2495
0.05
2490
0.10
-25
25
50
TA (C)
75
IP = 0 A
0.10
IOUT(Q) (A)
2510
2485
-50
100
8
50
75
50
TA (C)
ETOT (%)
5.4
0.5
1.0
VIOUT (V)
5.3
0.6
0.5
VIOUT(Q) (mV)
5.2
4.0
5.0 5.1
VCC (V)
100
125
150
0.15
-50
-25
25
50
75
100
125
150
TA (C)
ACS714
Characteristic Performance
IP = 20 A, unless otherwise specified
9.7
10.4
9.6
10.2
10.0
9.5
ICC (mA)
VCC = 5 V
9.4
9.3
9.8
9.6
9.4
9.2
9.2
9.1
-50
-25
25
50
75
100
125
9.0
4.5
150
4.6
4.7
4.8
4.9
TA (C)
5.5
0.25
ELIN (%)
1.5
IOM (mA)
5.4
0.30
1.0
2.0
2.5
VCC = 5 V; IP = 0 A,
After excursion to 20 A
3.0
3.5
0.20
0.15
0.10
4.0
0.05
4.5
5.0
-50
-25
25
50
75
100
125
0
50
150
25
25
100.6
100.4
Sens (mV/A)
100.8
2
0
2
99.8
99.6
99.4
99.2
25
75
50
100
125
99.0
50
150
25
25
TA (C)
4.5
108.00
4.0
106.00
Sens (mV/A)
VCC = 5 V
3.0
TA (C)
40
20
25
85
125
2.5
2.0
1.5
1.0
0.5
0
25 20 15 10
100
125
150
10
15
104.00
102.00
100.00
98.00
96.00
94.00
92.00
20
90.00
25 20 15 10
25
IP (A)
5
0
Ip (A)
10
15
20
25
2525
0.25
2520
0.20
2515
IOUT(Q) (A)
0.15
2510
IP = 0 A
2505
2500
0.05
0
0.05
2490
0.10
-25
25
50
TA (C)
75
100
125
150
IP = 0 A
0.10
2495
2485
-50
75
50
TA (C)
5.0
3.5
150
100.0
6
0
125
100.2
25
100
8
50
75
50
TA (C)
TA (C)
ETOT (%)
5.3
0.5
VIOUT (V)
5.2
0.35
VIOUT(Q) (mV)
5.0 5.1
VCC (V)
0.15
-50
-25
25
50
75
100
125
150
TA (C)
10
ACS714
Characteristic Performance
IP = 30 A, unless otherwise specified
9.6
10.2
9.5
10.0
ICC (mA)
9.4
VCC = 5 V
9.3
9.2
9.8
9.6
9.4
9.1
9.2
9.0
8.9
-50
-25
25
50
75
100
125
9.0
4.5
150
4.6
4.7
4.8
4.9
TA (C)
0.45
0.5
0.40
1.0
0.35
1.5
0.30
ELIN (%)
IOM (mA)
2.0
VCC = 5 V; IP = 0 A,
After excursion to 20 A
3.0
0.10
0.05
25
50
VCC = 5 V
75
100
125
0
50
150
25
25
100
125
150
66.6
66.5
66.4
Sens (mV/A)
ETOT (%)
2
0
66.3
66.2
66.1
66.0
65.9
65.8
8
50
25
25
75
50
100
125
65.7
50
150
25
25
TA (C)
70.00
4.5
69.00
VCC = 5 V
3.0
TA (C)
40
20
25
85
125
2.5
2.0
1.5
1.0
0.5
20
10
150
10
20
67.00
66.00
65.00
TA (C)
40
25
85
150
64.00
63.00
62.00
61.00
60.00
30
30
20
10
IP (A)
0
Ip (A)
10
20
30
2535
0.35
2530
0.30
2525
0.25
2520
0.20
IOUT(Q) (A)
IP = 0 A
2515
2510
2505
0.10
0.05
0
2495
0.05
2490
0.10
-25
25
50
TA (C)
75
100
125
150
IP = 0 A
0.15
2500
2485
-50
125
68.00
Sens (mV/A)
4.0
0
30
100
5.0
3.5
75
50
TA (C)
VIOUT (V)
75
50
TA (C)
TA (C)
VIOUT(Q) (mV)
5.5
0.20
4.5
0
5.4
0.25
4.0
-25
5.3
0.15
3.5
5.0
-50
5.2
2.5
5.0 5.1
VCC (V)
0.15
-50
-25
25
50
75
100
125
150
TA (C)
11
ACS714
Characteristic Performance
IP = 50 A, unless otherwise specified
9.8
9.7
10.0
9.6
ICC (mA)
9.5
VCC = 5 V
9.4
9.3
9.2
9.8
9.6
9.4
9.1
9.2
9.0
8.9
-50
-25
25
50
75
100
125
9.0
4.5
150
4.6
4.7
4.8
4.9
TA (C)
0.50
0.5
0.45
1.0
0.40
1.5
0.35
ELIN (%)
IOM (mA)
2.0
VCC = 5 V; IP = 0 A,
After excursion to 20 A
3.0
0.10
4.5
0.05
25
50
75
100
125
0
50
150
25
25
125
150
39.10
6
Sens (mV/A)
39.05
4
ETOT (%)
100
2
0
39.00
38.95
38.90
38.85
6
8
50
25
25
75
50
100
125
38.80
50
150
25
25
TA (C)
45.00
4.5
44.00
VCC = 5 V
3.0
2.5
2.0
42.00
41.00
1.5
39.00
38.00
40
25
125
1.0
0.5
-20
-10
10
20
30
37.00
36.00
35.00
-40
40
-30
-20
-10
IP (A)
0
10
Ip (A)
20
30
40
IP = 0 A
IOUT(Q) (A)
2526
2523
2520
2517
2514
2511
2508
2505
2502
2499
2496
2493
2490
2487
-50
150
40.00
TA (C)
-30
125
TA (C)
40
25
150
43.00
Sens (mV/A)
4.0
0
-40
100
5.0
3.5
75
50
TA (C)
VIOUT (V)
75
50
TA (C)
TA (C)
VIOUT(Q) (mV)
5.5
0.20
0.15
5.4
0.25
4.0
-25
5.3
VCC = 5 V
0.30
3.5
5.0
-50
5.2
2.5
5.0 5.1
VCC (V)
IP = 0 A
0.30
0.20
0.10
0
0.10
0.20
-25
25
50
TA (C)
75
100
125
150
0.30
-50
-25
25
50
75
100
125
150
TA (C)
12
ACS714
{ [
100 1
[{
VCC / 5 V
100
VIOUT(Q)VCC / VIOUT(Q)5V
SensVCC / Sens5V
VCC / 5 V
Accuracy
Over $Temp erature
Accuracy
25C Only
Average
VIOUT
Accuracy
Over $Temp erature
Accuracy
25C Only
IP(min)
IP (A)
+IP (A)
Full Scale
IP(max)
0A
Accuracy
25C Only
Accuracy
Over $Temp erature
Decreasing VIOUT(V)
13
ACS714
Power-On Time (tPO). When the supply is ramped to its operating voltage, the device requires a finite time to power its internal
components before responding to an input magnetic field.
Power-On Time, tPO , is defined as the time it takes for the output
voltage to settle within 10% of its steady state value under an
applied magnetic field, after the power supply has reached its
minimum specified operating voltage, VCC(min), as shown in the
chart at right.
Rise time (tr). The time interval between a) when the device
reaches 10% of its full scale value, and b) when it reaches 90%
of its full scale value. The rise time to a step response is used to
derive the bandwidth of the device, in which (3 dB) = 0.35 / tr.
Both tr and tRESPONSE are detrimentally affected by eddy current
losses observed in the conductive IC ground plane.
Primary Current
I (%)
90
Transducer Output
10
0
t
tPO (s)
Rise Time, tr
Step Response
200
180
160
140
120
100
80
60
40
20
0
TA=25C
IP = 5 A
IP = 0 A
10
20
CF (nF)
30
40
Output (mV)
50
10000
15 A
Excitation Signal
100
10
1
0.01
1200
0.1
CF (nF)
10
100
1000
800
600
tr(s)
1000
400
200
0
0.1
10
CF (nF)
100
1000
tr (s)
3.5
5.8
17.5
73.5
88.2
291.3
623
1120
tr(s)
Noise(p-p) (mA)
1000
180
160
140
120
100
80
60
40
20
0
0.1
10
100
CF (nF)
14
ACS714
Clock/Logic
Low-Pass
Filter
Hall Element
Sample and
Hold
Amp
Typical Applications
+5 V
+5 V
VPEAK
CBYP
0.1 F
1
2
C2
0.1 F
VCC
IP+
IP+ VIOUT
IP
IP FILTER
IP
GND
R4
10 k
D1
U1
LT1178 1N914
R1
1 M
CF
1 nF
6
5
R2
33 k
VCC
IP+
IP+ VIOUT
IP
R2
100 k
8
7
4
C1
0.1 F
IP FILTER
IP
GND
VOUT
2
C1
1000 pF
R3
3.3 k
6
CF
0.01 F
LM321
RF
1 k
ACS714
3
R3
330 k
R1
100 k
Q1
2N7002
RF
10 k
ACS714
3
COUT
0.1 F
VOUT
CBYP
0.1 F
VRESET
+5 V
+5 V
CBYP
0.1 F
R1
33 k
CBYP
0.1 F
1
2
IP+
VCC
IP+ VIOUT
8
7
RF
2 k
ACS714
IP
3
4
IP FILTER
IP
GND
VOUT
6
5
R1
10 k
CF
1 nF
D1
1N4448W
1
2
A-to-D
Converter
IP
C1
IP+
VCC
IP+ VIOUT
8
7
VOUT
IP FILTER
IP
GND
4
3
ACS714
3
RPU
100 k
R2
100 k
6
5
CF
1 nF
Fault
2 U1
LMV7235
D1
1N914
15
ACS714
RINTFC
RF + RINTFC
VATT = VIOUT
+5 V
Pin 3 Pin 4
IP
IP
VCC
Pin 8
Allegro ACS706
Voltage
Regulator
To all subcircuits
0.1 MF
Filter
VIOUT
Pin 7
Dynamic Offset
Cancellation
Amp
Out
N.C.
Pin 6
Resistive Divider
Input
RF
Application
Interface
Circuit
Gain
Offset
CF
1 nF
RINTFC
Trim Control
GND
Pin 5
IP+
IP+
Pin 1 Pin 2
+5 V
VCC
Pin 8
Allegro ACS714
Hall Current
Drive
IP+
Pin 1
IP+
Pin 2
IP
Pin 3
Sense Temperature
Coefficient Trim
Buffer Amplifier
and Resistor
Dynamic Offset
Cancellation
Signal
Recovery
VIOUT
Pin 7
Input
Application
Interface
Circuit
Sense
Trim
IP
Pin 4
0 Ampere
Offset Adjust
RINTFC
GND
Pin 5
FILTER
Pin 6
CF
1 nF
16
ACS714
4.90 0.10
8
0
0.65
6.00 0.20
Branded Face
8X
SEATING
PLANE
0.10 C
1.27 BSC
1.27
0.40
0.25 BSC
0.51
0.31
5.60
1.04 REF
1.27
1.75
0.25
0.17
3.90 0.10
SEATING PLANE
GAUGE PLANE
NNNNNNN
TPP-AAA
LLLLL
1.75 MAX
0.25
0.10
17
ACS714
Revision History
Revision
Revision Date
Rev. 9
Description of Revision
Update product selection, rise time, isolation,
patents
18