You are on page 1of 44

damian.brazionis@tecnous.com.

ar

Introduccin a las
Fibras pticas

Fibras pticas
Tecnologa de comunicacin, desarrollada en los aos 70,
que funciona enviando seales pticas por pelos de vidrio
muy finos
Rayos de Luz

Transmisor

Fibra

Receptor

An optical fiber is composed of a very thin glass rod, which is


surrounded by a plastic protective coating. The glass rod contains two
parts, the inner portion of the rod (or core) and the surrounding
layer (or cladding). Light, which is injected into the core of the glass
fiber, will follow the physical path of that fiber due to the total
internal reflection of the light between the core and the cladding.

Fibras pticas

Core

Cladding

Plastic Coating

The composition of optical fiber

2 tipos

Singlemode

Multimode
50 or 62.5 m
125 m

250 to 900 m

250 to 900 m

125 m

9 to 10 m

Tipos de Fibras: MM (Multi Modo)


Numerosos rayos de luz (modos) son transportados
simultneamente a travs de la fibra.
Multimode Graded Index

Multimode Step Index (obsoleta)

n2
nA

n1

nB
n1>n2

Fibras Multimodo :
850 a 1300 nm
Cortas distancias
LAN / Industria

nA>nB

Tipos de Fibras: SM (Mono Modo)


Un solo rayo de luz (modo) es transportado a travs de las
fibras.

Fibras Singlemode :
Transmisin de alta velocidad
1260 a 1660 nm
Largas distancias
Telecom/CATV CWDM/DWDM - FTTx

Atenuacin
La atenuacin es la disminucin de la potencia de la seal
a lo largo del enlace de fibra ptica.

atenuacin (dB/km)

1ra Ventana
820-880nm

2da Ventana
1285-1330 nm

850

1300

3ra Ventana
1525-1575nm

1550

Long. de Onda (nm)

Atenuacin es expresada en dB/km.

Atenuacin Intrnseca
Scattering (Rayleigh) es la prdida de seal de luz desde el

ncleo de fibra causado por impurezas o cambios en el ndice de


refraccin de la fibra.
Impurezas
Light scattered

Explica hasta el 95% de la prdida total


Varia como Att = 1/()^4 para todos los tipos de fibra

Atenuacin Intrnseca
Absorcin: La luz es absorbida debido a las caractersticas
qumicas o a las impurezas naturales en el vidrio.
Si
O

Imperfecciones

O O
Si
Si
O

Si
O

Si

Cu

Si O2

Debido a estructura atmica del material-oxidrilo(OH) y otras


impurezas
Explica hasta el 5% de la prdida total
Picos alrededor de 950 nm, 1244 nm, y 1383 nm

Atenuacin Extrnseca
Microcurvaturas
Las prdidas por microcurvaturas ocurren debido a deformaciones
microscpicas de la fibra en la interface core-cladding
Microcurvaturas

Macrocurvaturas
Las prdidas por macrocurvaturas ocurren debido a curvas en la
fibra que son grandes en relacin al dimetro

Macrocurvatura

Atenuacin debido a las curvaturas es mayor a 1550nm/ 1625nm de lo


que es a 1310nm

Atenuacin

Bendings
atenuacin

Atenuacin (dB/km)

OH Absorption Peaks
950-1240-1380 nm

Impurity
Absorption

Rayleigh Scattering
1/4

850

IR Absorption

1300

Long. de Onda(nm)

1550

Conectores & Adaptadores

Tipos de Conectores
Conector FC
Frula cermica ( 2.5 mm)
Mecanismo a tornillo
Utilizado principalmente con fibras SM

Conector SC
Frula cermica ( 2.5 mm)
Mecanismo Push-Pull
Utilizado principalmente con fibras SM

Conector MU
Frula cermica ( 1.25 mm)
Mecanismo Push-Pull

Tipos de Conectores
Conector ST
Frula cermica ( 2.5 mm)
Mecanismo Twist-lock
Utilizado principalmente con fibras MM

Conector LC
Frula cermica ( 1.25 mm)
Mecanismo Push-Pull

Conector E2000
Frula cermica ( 2.5 mm)
Mecanismo Push-Pull con una tapa
protectora sobre frula

Contacto Areo / Contacto Fsico

Air gap (un par de micrnes)

La separacin causa problemas de


prdidas (prdida de insercin y
perdida de retorno)

Conector Physical Contact (PC) :

Contacto fsico

Solo una pequea porcin de


luz es reflejada

PC: Physical Contact (Contacto fsico)


SPC: Super Physical Contact (Sper contacto fsico)
UPC: Ultra Physical Contact (Ultra contacto fsico)

Efectos de Altas Reflexiones (ORL)


Si los valores de ORL son muy Altos (valores bajos en dB),
la luz pueden resonar en la cavidad del diodo laser,
causando inestabilidad.
Eleva el ruido en la transmisin
Reduce el OSNR
Incrementa la tasa de BER
Eleva la interferencia en la fuente de luz
Cambia la longitud de onda central y potencia de salida
Alta incidencia en daos del transmisor

Pulidos Angulares

20.qxd

through its core is determined by its numerical


aperture
(NA). by the core.
refracted and
is not captured
2

n1 sin i = n2 sin r

NA=sin0 = n1 -n2
2/5/07

Where n is the maximum angle of acceptance (that


0 is, the limit
between reflection and refraction), n1 is the core refractive index,i
and n2 is the cladding refractive index.

( Principios de transmisin )

4:58 PM

Page 5

Core
Full Acceptance
Cone

Cladding

n2
n1

Refraction of light

1.3.1.2 Reflection
Reflection is the abrupt change in direction of a light ray at an
1.3.1.1 Refraction
ninterface
between two dissimilar transmission media. In this case,
2
Refraction is the bending of a
ray of light at an interface between
the
light
ray
to thePage
media
0 If > 0, then the ray is1520.qxd
2/12/07 returns
4:53 PM
4 from which it originated.
fully
two dissimilar transmission media.
If a < 0, then the ray is reflected and remains in the core.
refracted and is not captured by the core.

n1

i = r

n1 sin i = n2 sin r

The injection of light into a fiber

n2

The full acceptance


cone is defined as 2n.

n1

n2

n1

1.3.1 Light Propagation


r
The propagation
of a ray of light in optical fiber follows
Snell1.3 Transmission
Principles
Descartes law. A portion of the light is Reflection
guidedof through
the optical
light A ray of light enters a fiber at a small angle . The capability
fiber when injected into the fibers full acceptance(maximum
cone.
acceptable value) of the fiber cable to receive light

Refraction of light

1.3.1.2 Reflection
Reflection is the abrupt change in direction of a light ray at an
interface between two dissimilar transmission media. In this case,
the light ray returns to the media from which it originated.
If a < 0, then the ray is reflected and remains in the core.
i = r

through its core is determined by its numerical aperture (NA).


2

NA=sin0 = n1 -n2

Where n is the maximum angle of acceptance (that is, the limit


between reflection and refraction), n1 is the core refractive index,
and n2 is the cladding refractive index.
n2

Core

Cladding

Conectores PC/APC
El ngulo reduce la cantidad de luz reflejada en la
interface del conector.
Conector Angled Physical Contact (APC) :

5 to 15

Angled Surfaces Contact

PC: Physical Contact (Contacto fsico)


APC: Angled Physical Contact (Contacto fsico angular )
NO CONECTAR PC CON APC YA QUE SE DAA LA
INTERFAZ DE FIBRA

Fuentes de Luz
Son los elementos encargados de inyectar
una seal ptica en la fibra

LED: Light Emitting Diode

LD: Laser Diode

DFB: Distributed Feedback


FP: Fabry-Perot

Mediciones bsicas en
Fibra ptica

Mediciones bsicas de FO

Perdida de Insercin
Perdida de Retorno ptico
Reflectometra ptica (OTDR)

Perdida de Insercin
Medicin de la perdida de insercin con una fuente de luz laser y un medidor
de potencia
PERMITE CONOCER LA ATENUACION DE LA FO
1) Ref Power: -5dBm
Light
Source

Power
Meter

0dB 2) Zero Ref


3) 0dB

Medicion de Referencia

Light
Source

Power
Meter

-4.5dB

Medicion de Perdida de insercion

Link Loss
-4.5dBr

Prdida de Retorno ptico


PERMITE CONOCER LA PORCION DE LA LUZ EMITIDA QUE ESTA
SIENDO REFLEJADA NUEVAMENTE HACIA LA FUENTE

PPC

PAPC

PAPC

PAPC

Light
Source

Photodiode

PF

PF

PT

PF
PT: Output power of the light source
PAPC: Back-reflected power of APC connector

ORL (dB) = 10.Log

>0

PPC: Back-reflected power of PC connector


PF: Backscattered power of fiber
PB: Total amount of back-reflected power

Reflectometra ptica - OTDR

FUNCIONAMIENTO DE UN OTDR

El instrumento emite un impulso por la fibra

A medida que la luz viaja por la fibra, parte


de ella es difundida de regreso debido a la
difusin normal en el medio

Buena parte de la energa del impulso se


refleja en el extremo opuesto de la fibra
(debido a la diferencia entre los ndices de
refraccin del vidrio y del aire)

La luz reflejada y la luz difundida de regreso


son absorbidas por otros puntos de la fibra,
como empalmes y conectores

Reflectometra ptica - OTDR


FUNCIONAMIENTO DE UN OTDR

midiendo el tiempo entre la emisin del impulso y las reflexiones en empalmes,


conectores y final de la fibra, es posible medir la distancia a los puntos de reflexin

el instrumento indica grficamente la distancia y la atenuacin de cada punto de reflexin

midiendo la reduccin de la potencia de la luz desde la emisin del impulso hasta el


regreso de la reflexin final, es posible calcular la atenuacin por unidad de longitud

Entonces un OTDR Permite:

Medicin de impulsos
Medicin de la potencia retro-esparcida y reflejada (muestreo)
clculo de la atenuacin hacia adelante
Medicin del tiempo de propagacin
clculo de la distancia
Localizacin de Fallas

Traza OTDR

El OTDR muestra un mapa detallado del enlace de fibra


Perdida de conectores y empalmes
Reflectancia
Distancias

OTDR Definiciones
RANGO DINMICO

Parmetro importante de un OTDR


Determina la mx. longitud de fibra observable por el OTDR, y por ende la eficacia de
este en la red.

Es una medida de sensibilidad del instrumento ( se mide en dB)

A mayor rango dinmico, mejor deteccin de eventos

OTDR - Definiciones
ZONA MUERTA

El OTDR debe detectar seales mucho ms tenues que la inyectada por l


El fotodiodo detector se saturar cuando las reflexiones sean muy grandes
Por esto, requiere un tiempo de recuperacin para salir de la saturacin, donde no
detectar reflexiones.
Asi, la zona muerta, estar dada por el tiempo de pulso ms el tiempo de recuperacin
A menor zona muerta, mejor el OTDR y la posibilidad de detectar eventos.

OTDR - Definiciones
ZONA MUERTA DE ATENUACIN

Indica la distancia minima desde un evento reflectivo (par de conectores, empalme


mecnico) luego de la cual es posible detectar un evento no-reflectivo (empalme por
fusin, atenuacin)

La zona muerta de atenuacin depende del ancho del pulso, la distancia al evento, la
reflectancia del primer evento y su perdida.

Definicin

D < ADZ
(no se puede ver el empalme)

D > ADZ
(se puede ver el empalme)

OTDR Definiciones
ZONA MUERTA DE EVENTOS

Indica la distancia minima en la que dos eventos reflectivos (par de conectores, empalme
mecnico) pueden ser distinguidos.

Si bien pueden distinguirse dos eventos, no se puede identificar la perdida individual de


cada uno

La zona muerta de eventos depende del ancho del pulso

D < EDZ

D > EDZ

(no se puede separar los eventos)

(se puede ver el 2do evento)

OTDR Seleccin del ancho de pulso

Controla la cant. de luz


inyectada en la fibra

Ancho de pulso mas grande

Mayor distancia
Mayor zona muerta

Ancho de pulso mas chico

Menor distancia
Reduccin de la zona muerta

Interpretacin de los resultados

Eventos

Final de Fibra
Macrobending

Conector

GANANCIA??
Fusin

Prdidas de insercin y retorno


Evento Reflexivo

Conector
Tpico: -30/-50 dB
Prdida de Retorno
enmienda mecnica
Tpico: -50/-60 dB

Conector
Tpico: 0,5dB
Prdida de Insercin
enmienda mecnica
Tpico: 0,2 dB

Prdidas de retorno
Prueba de Prdida de Retorno en Conector
Nivel de Potencia
inyectado

Reflectancia

A
B
dB
km

Reflectancia aire / silicio = -14 dB

nivel de Potencia
Recibida

Ex: Conector A= -50 dB


Conector B= -30 dB

Valores tpicos
Valores de Prdida nos Conectores
atenuacin
Tecnologa

Conectores

Contacto Fsico
PC

ST, SC, FC,


DIN, E2000

Angled
Physical
Contact - APC
(Monomodo
somente)

FC/APC, SC/APC,
ST/APC

Tpico

(enmienda por fusin


<0.1dB)
< 0.5 dB/ 0.7 dB<

< 0.5 dB

Reflectancia
Tpico

(Transicin Fibra / aire


-14 dB)
< -30 dB/-50 dB<

< -55 dB/-75 dB <

Ganancia en una FO?

Pequeas diferencias en los coeficientes de


reflexin entre dos FO, pueden hacer que el
OTDR muestre que el empalme tenga
ganancia.

Anlisis bidireccional

Anomalas de Fantasmas - Ghosts

Los OTDRs JDSU pueden detectar y quitar este efecto de la traza

Anomalas de Fantasmas - Ghosts

Ghost

Verificacin de limpieza/ integridad


PatchCord
Inspeccionar el patchcord nos permite
saber que el 50% de la conexin esta
correcta.
- Inspeccionar solo el PATCHCORD es
un ERROR frecuente en FO. Se est
omitiendo la mitad de la conexin.
- En la mayora de los casos en redes
FTTx la fibra estar ACTIVA.

Verificacin completa - Sondas digitales

Propuesta para un trabajo profesional


Se recomienda seguir el proceso INSPECCIONAR ANTES DE CONECTAR
para asegurar que la superficie del conector est limpia antes realizar la
conexin.

Gracias por su atencin!


damian.brazionis@tecnous.com.ar
TECNOUS SA.
Tel. +54 11 5368 4400
Caseros 824
(C1152AAR) Buenos Aires
Argentina