You are on page 1of 24

Servicios acsticos

SBT

Aldo CULASSO
BAKER ATLAS NEUQUN
Marzo 2009

The Best Choice

CEMENTACIN
Para qu se cementa el casing?

Brinda un soporte mecnico y proteccin al casing en caso de colapso,


corrosin o dao en las perforaciones siguientes.

Asla hidrulicamente distintas zonas permeables y restringe el flujo en


el espacio casing-formacin.

Para qu evaluar el cemento?

Determinar la efectividad de la adherencia del cemento en el espacio


anular entre el casing y la formacin.

Identificar intervalos con zonas aisladas.

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

DATOS TCNICOS

Maximum Temperature . . . . . . . 350 F (177 C)


Maximum Pressure . . . . . . . . . . 20,000 psi (1406 kg/cm )
Minimum Casing ID . . . . . . . . . . 4.0 in. (101.6 mm)
Maximum Casing ID . . . . . . . . . 15.5 in. (393.7 mm)
Tool Diameter . . . . . . . . . . . . . . 3.38 in. (85.7 mm)
Maximum Logging Speed . . . . 35 ft/min (10.7 m/min)
Measurement Range. . . . . . . . . 0-22 dB/ft Compensated attenuation
Absolute Accuracy . . . . . . . . . . 1.0 dB/ft or 10 of log value
Repeatability . . . . . . . . . . . . . . . 1.0 dB/ft or 10 of log value
Vertical Resolution . . . . . . . . . . 0.25 ft (7.62 cm) Normal Presentation averages
data over 3 ft
Radial Resolution . . . . . . . . . . . 60 degrees
Depth of Investigation . . . . . . . . 2 in. (5.08 cm)
Detector Type
VDL . . . . . . . . . . . . . . . . . . . . . 20 kHz Piezo-electric cylinder
Pads. . . . . . . . . . . . . . . . . . . . . 100 kHz Piezo-electric Stack
Pad Force. . . . . . . . . . . . . . . . . 50 lbs (22.7 kg)

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

INTRODUCCIN
Mide cuantitativamente la integridad en 6 segmentos angulares en el casing.
Doce transductores estn montados en 6 patines (pads), que se ponen en contacto con el interior del casing
para proveer atenuaciones compensadas.
No depende de la sensibilidad de los detectores ni de la potencia de los transmisores.
No es sensible a fluidos pesados, gas, formaciones rpidas, temperatura, presin o moderada
descentralizacin, puede medir incluso sin fluido en el pozo con dificultades.
Se comunica con el sistema de superficie a travs de la electrnica 1633EA.

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

PRINCIPIO DE FUNCIONAMIENTO (Subciclos)

Subciclo 1:

Dispara Tx del pad 1.

Se registran receptores en pads 2 (near) y 3


(far).
Subciclo 2:

Dispara Tx del pad 4.

Se registran receptores en pads 3 (near) y 2


(far).
Las 4 amplitudes se combinan para calcular una
medida de atenuacin compensada.

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

PRINCIPIO DE FUNCIONAMIENTO (SPREADING LOSES)

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

STEERED TRANSDUCERS

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

POSICION DE LOS SWITCHS DEL LCP

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

VENTANAS DE CONTROL

ECLIPS MEMORY
TOOL
TABLE

SURFACE
TABLE

1 3 2
TOOL

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

VENTANAS DE CONTROL

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

10

CEMENTO COMPRESIN

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

11

Compressive Strength = 3500 psi

Compressive Strength = 200 psi

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

12

SUBCICLE CONTROL

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

13

DIGITISED WAVEFORM

200
4

7
7

250

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

14

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

15

CURVAS

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

16

CURVAS

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

17

INTERPRETACIN

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

18

CALIBRACIN / VERIFICACIN
Relative Bearing Calibration/Verification

Se calibran los cambios de los acelermetros cuando es girada 60.

SBT Pad Calibration/Verification


Se utiliza como control de calidad y no afecta las curvas del registro.
Receiver noise levels: debe ser < 10.
Pad sensitivities: debe ser > 50.

SBT Normalization

Las curvas de atenuacin deben ser comparadas con el promedio de todas


las atenuaciones a lo largo de un intervalo.
Los factores se calculan en dB/ft al final de un registro.
Se utiliza como control de calidad.
Los 6 factores deberan tener un promedio similar.
Se deben obtener como mnimo 1600 muestras (122m @ 4 spf).
Los factores de normalizacin deben ser menores a 1dB/ft.

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

19

VDL
El VDL se obtiene a travs de un espaciamiento de transmisor y
receptor de 5 ft.
Se observa la onda completa.
Se observan los arribos de caera, de formacin y de fluido.
Uso primario para la evaluacin de la adherencia del cemento a la
formacin.
El VDL sub va ubicado en la parte inferior del string.

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

20

VDL

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

21

VDL

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

22

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

23

The Best Choice

Efficiency Data Accuracy People-oriented Service


Proprietary Information

Baker Atlas

24

You might also like