1.50
Voltage
Delta Vo ltage
1.45
1.40
Heavy Drain (505 mA )
1.35
0
20
40
60
80
100
120
140
Time (Milliseconds)
(fig. 1)
The typical effective resistances of fresh
Energizer alkaline cylindrical batteries (using a 5
mA stabilization drain followed by a 505 mA 100
millisecond pulse) will be approximately 150 to
300 milliohms, depending on size.
Page 1 of 2
TECHNICAL BULLETIN
Battery Internal Resistance
December 2005
IR (ohms)
Version 1.1.0
.8
.6
.4
.2
.0
-40
-20
20
40
Temperature (C)
(fig 2.)
In summary, internal resistance can be
calculated based on the voltage drop of the
battery under a known load. Results will be
affected by technique, settings and
environmental conditions. The internal
resistance of a battery should be viewed as a
general guideline and not as a precise value
when applying it to the expected voltage drop in
a specific application.