Abstract This report shows a detailed analysis of the steadystate response of the passive circuit elements, as are resistors
(energy dissipation elements), capacitors and inductors (energy
storage elements). There is an emphasis on the amplitude and
phase variations presented according to each element. To achieve
that, were designed three circuits: series RC, RL and RLC, using
phasors, impedances, and Kirchhoffs Laws in the frequency domain. These circuits were supplied by signal generator (sinusoidal
function with medium-high frequency) and allow us to visualize and
measure some parameters of the wave forms obtained, including
the phase shift between the input signal (generator voltage) and
the resistor, capacitor or inductor voltage and current. The voltage
signals as a function of time, were observed on the oscilloscope,
that also enable us to get the Lissajous curve; providing us two
different methods to find phase shifts. Finally were compared the
wave forms obtained in the laboratory with the theoretical expected
functions, and was determined the error to each case. We get
the expected results, the wave forms correspond with theoretical
functions, and the phase variations errors were due to the low
accuracy of the oscilloscope measures. These results validate the
theoretical methods to analyze AC circuits, and these exhibit us
the real main characteristics of the different circuit elements when
those are exposed to AC signals, that were commonly used in the
transmission and generation systems of electrical power.
Index TermsImpedance, Phasor, Steady-State Response, Shift
Phase.
I.
I NTRODUCCIN
Figura 1. Circuito RC
Figura 2. Circuito RL
tretardo
360
T
Lissajous = arcsin
Y0
YM
[]
(1)
[]
(2)
(3)
VL = IL jL = IL L + 90
(4)
VC = IC (j
1
1
) = IC
90
C
C
(5)
III-A1. Circuito RC: Como se ha mencionado en la seccin anterior, el circuito RC que se utiliz es el de la Figura
1. El ngulo entre la tensin y la corriente que pasa a travs
de la capacitancia ha sido medido con ayuda del osciloscopio, analizando los resultados en pantalla y condensando la
informacin de la seccin 4.1 en la Figura 6, se estimaron los
valores de las divisiones internas del display del dispositivo
de medicin, prosiguiendo de esta manera se pudo obtener la
diferencia en grados entre el pico de tensin de entrada y el
pico de tensin en la capacitancia (Figura 8 de la seccin 4.1)
y la diferencia en grados entre el pico de tensin de entrada y
el pico de tensin en la resistencia equivalente (Figura 12 de
la seccin 4.1).
360
= 0,4
= 19,2
7,5
360
= 76,8
7,5
(6)
(7)
(8)
360
= 38,4
7,5
(10)
360
= 43,2
7,5
(11)
(12)
8,6
Yo
) = arcsin(
) = 61,35
YM
9,8
(14)
Yo
4,5
) = 152,67
) = arcsin(
YM
9,8
(15)
Ahora se calcula el desfase para la tensin en el condensador, se analiza la Figura 27 de la seccin 4 y queda:
V InV C = arcsin(
Yo
4,7
) = 28,66
) = arcsin(
YM
9,8
(16)
(17)
(18)
IV-A.
Circuito RC
III-E. Coinciden las magnitudes y ngulos de fase obtenidos experimentalmente con los valores tericos?
Aunque los resultados no son exactamente los mismos, el
error existente es bajo, por lo que los resultados obtenidos
en teora son muy buenos y nos permiten predecir con gran
fiabilidad los resultados que se obtendrn en el laboratorio o
ms importante an, en una aplicacin industrial, cientfica o
comercial.
Tomando como ejemplo los datos obtenidos experimentalmente y los valores tericos para el circuito RC, y que
se pueden encontrar en la seccin de anlisis de resultados
(Cuadro 1 y Cuadro 2), se obtiene un error de:
6,1158 4,8
| 100 = 21,51 %
(19)
6,1158
Que es el error que se presenta en el valor experimental
medido de la magnitud de la tensin en la resistencia equivalente con respecto al valor encontrado con ayuda de la teora.
As mismo:
EM = |
52,1053 52,1937
| 100 = 0,17 %
(20)
52,1053
Que corresponde al error entre los desfases para las mismas
tensiones en su valor experimental y terico.
El resto de clculos correspondientes al error en magnitud
y fases, tanto en valores estimados en el dominio del tiempo
como por el mtodo de curva de Lissajous estn consignados
en la seccin de anlisis y permiten corroborar que el error
que se presenta es en general bajo.
EF = |
IV. R ESULTADOS
Para la obtencin de las formas de onda de corriente y
tensin en los diferentes elementos del circuito se utilizaron
los siguientes equipos: Generador de Seales GW Intek GFG8215A (Impedancia de Salida Nominal 50 ), Multmetro
Fluke 112 True RMS, Osciloscopio - HITACHI V-252. Se
obtuvieron las formas de onda en funcin del tiempo y las
curvas de Lissajous para la resistencia equivalente, condensador e inductancia respectivos a cada circuito diseado. En las
grficas en funcin del tiempo se presenta la seal de entrada
(tensin del generador de seales) y la funcin obtenida
para determinado elemento . Se incluyen las imgenes de las
simulaciones realizadas en Multisim.
IV-B.
Circuito RL
IV-C.
Circuito RLC
10
11
V.
A NLISIS DE R ESULTADOS
12
V-A.
Circuito RC
13
Cuadro II
R ESULTADOS O SCILOSCOPIO EN FUNCIN DEL TIEMPO C IRCUITO RC
Cuadro III
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS C IRCUITO RC
Cuadro I
R ESULTADOS T ERICOS C IRCUITO RC
Cuadro IV
R ESULTADOS O SCILOSCOPIO EN FUNCION DEL TIEMPO S IMULACIN
C IRCUITO RC
Cuadro V
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS S IMULACIN
C IRCUITO RC
14
Cuadro VIII
R ESULTADOS O SCILOSCOPIO EN FUNCIN DEL TIEMPO C IRCUITO RL
Cuadro VI
R ESULTADOS DE E RROR R ELATIVO C IRCUITO RC
Cuadro IX
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS C IRCUITO RL
V-B.
Circuito RL
Cuadro VII
R ESULTADOS T ERICOS C IRCUITO RL
Cuadro X
R ESULTADOS O SCILOSCOPIO EN FUNCION DEL TIEMPO S IMULACIN
C IRCUITO RL
Cuadro XI
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS S IMULACIN
C IRCUITO RL
Cuadro XII
R ESULTADOS DE E RROR R ELATIVO C IRCUITO RL
V-C.
15
Cuadro XIV
R ESULTADOS O SCILOSCOPIO EN FUNCIN DEL TIEMPO C IRCUITO RLC
Circuito RLC
Cuadro XV
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS C IRCUITO RLC
Cuadro XIII
R ESULTADOS T ERICOS C IRCUITO RLC
Cuadro XVI
R ESULTADOS O SCILOSCOPIO EN FUNCION DEL TIEMPO S IMULACIN
C IRCUITO RLC
Cuadro XVII
R ESULTADOS O SCILOSCOPIO C URVA DE L ISSAJOUS S IMULACIN
C IRCUITO RLC
Cuadro XVIII
R ESULTADOS DE E RROR R ELATIVO C IRCUITO RLC
16
Al no disponer de un instrumento que analice directamente la corriente en funcin del tiempo para un circuito
fsico es necesario recurrir a la relacin de la misma
con la tensin en la resistencia mediante la ley de Ohm,
que para elementos puramente resistivos no presenta un
desplazamiento en el ngulo de fase con respecto a la
referencia propuesta, todo esto para obtener el desfase
neto que se presenta en la corriente para un circuito RLC
serie y as poder calcular el desfase con respecto a la
tensin en cada uno de los elementos.
Las curvas de Lissajous nos permiten medir los desfases
de una manera mas sencilla y con mayor exactitud. Sin
embargo es imposible determinar el signo del desfase
(adelanto - atraso), por lo que se requiere de las curvas
en funcion del tiempo para esto.
R EFERENCIAS
VI.
C ONCLUSIONES
El osciloscopio permite medir los desfases y las amplitudes de seales continuas en el tiempo provenientes de
voltajes presentes en los diferentes elementos de circuito.
Sin embargo debido a la resolucin de las imgenes
obtenidas, y sumando la incertidumbre ocasionada por
la percepcin de la persona que est interpretando la
informacin mostrada en pantalla los resultados pueden
presentar una baja exactitud y producir errores significativos en las mediciones.
Al medir con los dos canales del osciloscoipio es importante considerar que las tierras de ambos canales estn
acopladas (internamente), por lo tanto si los elementos
donde se desea medir no comparten la misma tierra en
el circuito es probable que en conexin de uno de los dos
canales ocasione la omisin de uno o varios elementos
en el circuito puesto que aterriza uno de los nodos,
obteniendo una curva erronea en el o los elementos que
se queran analizar.
Cuando se toma el desfase de la seal de entrada como el
ngulo de referencia y se realizan transformaciones hacia
el dominio de la frecuencia con fasores la complejidad en
el anlisis del desfase en cada uno de los componentes
se ve reducido de manera considerable puesto que se
trabaja con operaciones algebraicas y con conceptos que
evidencian transparentemente las magnitudes y desfases
en los parmetros en lugar de tener que trabajar con
ecuaciones diferenciales, adems de poder reducir el
circuito con mayor facilidad a uno equivalente RLC serie
o paralelo, en caso de que esto sirva para la obtencin
de la funcin de transferencia deseada.