You are on page 1of 77

Internal

OWF001202 HLR9820
SAU Hardware & Local
office Data
ISSUE 2.2

HUAWEI TECHNOLOGIES CO., LTD.

www.huawei.com

All rights reserved

Introduction
z

Hardware data configuration is the first step of SAU data


configuration.

After this course, trainees will understand HLR9820 hardware


in-depth.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

Upon completion of this course, you


will be able to:
> Master the hardware& local office
data configuration.
> Master all the logical NO. principle.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

Chapter 1 Basic concepts


Chapter 2 Data configuration
Chapter 3 Relative maintenance command
Chapter 4 Configuration example

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

Where is the data configured?


HLR9820 data works for:
z

SAU (Signaling Processing)

HDU (MAP Services Processing)

The data is configured in:


z

LMT (For SAU)


> Hardware Data
> Local Office Information
> Signaling Data

SMU Client (For HDU)


> Global Data

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

Chapter 1 Basic concepts


1.1 Elements and position
1.2 Module
1.3 Preparations
1.4 Data config. sequence

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

Elements and position


z

Module structure

HLR9820
Cabinet

Frame

Cabinet

Board
HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Frame

Page 7

Board

Elements and position


z

Cabinet

HLR9820 has 1 or 2 cabinets.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 8

Elements and position


z

Frame and board


SAU has two kinds of frames:
basic frame and expansion frame.
There are 1 basic and two
W
C
S
U

W
C
S
U

W
C
C
U

W
E
P
I

W
E
P
I

W
C
C
U

W
B
S
G

W
B
S
G

W
S
M
U

W
S
M
U

W
I
F
M

P
S
M

W
I
F
M

P
S
M

Front
3 4 5

6 7

8 9

10 11 12 13 14 15 16

17

18

Back
WW
S H
I S
U C

W
S
I
U

W
S
I
U

W
B
F
I

W
B
F
I

W
C
K
I

W
C
K
I

expansion frames in full


configuration.
Only IBM solution has expansion
frame. It depends on numbers of

P
S
M

P
S
M

subscriber.
Front board and back board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 9

Elements and position


zType

and function of the boards


Front board

Back board

WSMU

System Management Board

WSIU

System Interface Board

WCCU

Call Control Board

WEAM

E1 ATM forward

WEPI

ATM Interface Board

WCSU

Call Control and Signaling


Processing Board

WEPI

E1 Interface Board

WBSG

Broadband Signaling
Processing Board

WIFM

IP Transferring Module Board

WBFI

Back Far End Interface


Board

WALU

Alarm Board

PSM

Power Supply Board

PSM

Power Supply Board

WHSC

Hot-swap Control Board

WCKI

Clock Interface Board

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Elements and position

Number of devices

To help in recognizing all categories of module components, it is


necessary to number those of the same category uniformly.
Shelf number
zTo recognize individual shelves easily, each shelf is
given a number, called shelf number.
zThe shelf with the basic frame is numbered as Shelf 0.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 11

Elements and position


z

Number of devices

Frame number
zThe system can support ten frames at most, numbering
from 0 to 9.
zThe basic frame in the integrated configuration shelf is
numbered as Frame 0.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Elements and position


The 8-bit Dual Inline Package (DIP) S3 of SIU is provided
for setting frame numbers. The corresponding setting
table is shown in follow
DIP
Frame No.

on

on

on

on

on

on

on

on

on

on

on

on

on

on

on

off

on

on

on

on

on

on

off

on

on

on

on

on

on

on

off

off

on

on

on

on

on

off

on

on

on

on

on

on

on

off

on

off

on

on

on

on

on

off

off

on

on

on

on

on

on

off

off

off

on

on

on

on

off

on

on

on

on

on

on

on

off

on

on

off

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Elements and position

Slot number
Slot number is used to identify the slot of a specific
board that is inserted into a frame.
Each frame contains 21 slots at most (No. from 0 to 20)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Chapter 1 Basic concepts


1.1 Elements and position
1.2 Module
1.3 Preparations
1.4 Data config. sequence

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Module
z

Module number

Module number is set according to the type of the board


and is numbered from 2.
Modules of the same board are numbered uniquely. Here
are the numbering rules:
zWSMU Module number: 2~21
zWCCU/WCSU Module number: 22~101
zWEAM/WIFM/WBSG Module number: 132~211

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 16

Chapter 1 Basic concepts


1.1 Elements and position
1.2 Module
1.3 Preparations
1.4 Data config. sequence

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 17

Preparations
Before the data configuration, you should know
z

The networking and configuration conditions

The requirements put forward during engineering design


stage

The local office information (SPC/HLR No./CC etc.)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Common MML commands


Command

Function

ADD

Add database data

MOD

Modify database data

RMV

Delete database data

LST

Query database data

DSP

Query status of related equipment and resource

SET

Set data or status

LOF

Start offline mode

LON

Start online mode

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Offline
If it is the initial data configuration for the deployment:
Command or step

Function

LOF

Start the offline mode

SET CWSON: SWT=OFF

Set the alarm output switch of the current workstation


to OFF

SET FMT: STS=OFF

Set format status to OFF

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Online
After that, how to load the data to switch?
Command or step

Function

LON

Start the online mode

SET CWSON: SWT=ON

Set the alarm output switch of the current workstation to ON

SET FMT: STS=ON

Set format status to ON

FMT

Format all data of all modules

Loading data in power-down status

Remove two Wireless System Management Units (WSMUs) to


simulate equipment power-down and then load data.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Chapter 1 Basic concepts


1.1 Elements and position
1.2 Module
1.3 Preparations
1.4 Data config. sequence

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

HLR9820 Data Configuration Sequence


Start

Configure hardware data

Configure local office information

Configure signaling data

End

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

Questions

HUAWEI TECHNOLOGIES CO., LTD.

Whats the numbering principle of shelf,


frame, board?

Which board has module number?

Can boards in same module exist in


different frames?

Whats the difference of online and offline


mode?

All rights reserved

Page 24

Chapter 1 Basic concepts


Chapter 2 Data configuration
Chapter 3 Relative maintenance command
Chapter 4 Configuration example

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Chapter 2 Data configuration


2.1 Configuration Flow
2.2 Data configuration

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Configuration Flow
Add
AddShelf
Shelf
Set
SetLocal
LocalOffice
Office
Information
Information

Add
AddFrames
Frames
Add
AddBoards
Boards
Add
AddWCSU
WCSU
Add
AddWEPI
WEPI

Add
AddWCKI
WCKI

Add
AddWCCU
WCCU

Conf.
Conf.MEM
MEM

Conf.
Conf.clock
clockMode
Mode
Add
AddWIFM
WIFM

Conf.
Conf.E1
E1

Clock
ClockRefer.
Refer.

HUAWEI TECHNOLOGIES CO., LTD.

Conf.
Conf.CPC
CPC
All rights reserved

Conf.
Conf.FE
FE
Page 27

Configuration Flow for ATM


Add
AddShelf
Shelf
Set
SetLocal
LocalOffice
Office
Information
Information

Add
AddFrames
Frames
Add
AddBoards
Boards
Add
AddWEAM
WEAM

Add
AddWCCU
WCCU

Add
AddWEPI
WEPI

Clock
ClockRefer.
Refer.

Add
AddWCKI
WCKI

Conf.
Conf.MEM
MEM

Conf.
Conf.clock
clockMode
Mode

Conf.
Conf.E1
E1

HUAWEI TECHNOLOGIES CO., LTD.

Conf.
Conf.IMA/UNI
IMA/UNI
All rights reserved

Page 28

Conf.
Conf.PVC
PVC

Chapter 2 Data configuration


2.1 Configuration Flow
2.2 Data configuration

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

Commands
z
z
z

Adding IMA group

Adding IMA link

Adding UNI link

Adding PVC link

Adding Shelf
Adding Frame
Adding Board

Adding E1

Setting Clock Mode

Adding Board Clock Reference Source

Adding FE Configuration

Adding MEM Configuration

Set Local Office Information

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Shelf/Frames/Boards
z

Relationship

ADD SHF
[Shelf Number]
[Location Title]
[Position
Number]
[RoW Number]
[Column
Number]

HUAWEI TECHNOLOGIES CO., LTD.

ADD FRM
[Frame Number]
[Shelf Number]
[Position
Number]

All rights reserved

ADD BRD
[Frame Number]
[Slot Number]
[Location]

Page 31

Shelf/Frames/Boards
z

Add Shelf

For HLR9820 SAU, there is only one shelf. The number always is 0.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Shelf/Frames/Boards
zAdd

Frames
For SUN solution, there is only one frame. The frame
number is always 0.
For IBM Solution, there are three frames at maximum
configuration. The frame number are from 0 to 2.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

Shelf/Frames/Boards
z

Add Boards
> Before adding the boards, the frame and shelf to which the
boards belong must have already been added.
> WSMU/WALU/PSM will be added automatically after the
frame has been added.
> If parameters need to be modified, please delete the board
at first then add it again.
> Two pieces of CPC will be added automatically after the
WCSU has been added.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

Add E1
z

Configure the WEPI if the module needs to process the SS7.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

Set Clock Mode


z

Only for TDM/ATM networking

SET CKICFG: CL=LEVEL2, WM=MANUAL, MCS=LCK1;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 36

Board Clock Reference Source


z

Only for TDM/ATM networking

After configuring clock mode

Parameter indicate the physical position:


Frame No.
Slot No.
E1 No.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 37

Add FE configuration
z

Function:
> WIFM/WBFI is the interface between SAU and IP network.
They process MAC and IP protocol.
> WIFM deliver IP package to WBSG.
> We need setup FE (Fast Ethernet) interface for signaling
traffic.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 38

Add MEM configuration

Function:
z

Setup the connection between SAU and HDU

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 39

Hardware Connection
MODULE

WCSU/WCCU

WCSU/WCCU

HUAWEI TECHNOLOGIES CO., LTD.

W
H
S
C
0

W
H
S
C
1

L
A
N
S
W
I
T
C
H

HDU
1#

L
A
N

HDU

S
W
I
T
C
H

All rights reserved

2#

Page 40

MEM Configuration
Command
z

ADD MEMCFG
> Module: Module No. of WCCU/WCSU.
> Local IP address: IP of WCSU. it is defined by this command.
> Remote IP address: IP of HDU. Come from HDU.
> Remote Port: IP port of HDU, always be 16500.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 41

Add IMA group


Command
z

ADD IMAGRP
> WEAM Module: Module No. of .WEAM
> IMA Group No.: Number of IMA group, ranging from 0 to 7.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 42

Add IMA link


Command
z

ADD IMALNK
> WEAM Module: Module No. of WEAM
> IMA Group No.: Number of IMA group, ranging from 0 to 7.
> IMA link port no: Number of the E1 port added to the IMA group

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 43

Add UNI link


Command
z

ADD UNILNK
> WEAM Module: Module No. of WEAM
> UNI link port no: Number of the E1 port added to the IMA group

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 44

Add PVC link


Command
z

ADD PVCLNK
> PVC link number: Number of the global PVC links
> VPI: Virtual path identifier (VPI)
> VCI: virtual channel identifier (VCI)
> Signal distribution module number:
> Signal handle module number:
> IMA group number:
> UNI port number:

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 45

Set Local Office Information


Command
z

Set OFI
> Signaling point code (SPC)
> Signaling network where the local office resides (NI)
> Network Structure
> Whether the local office is a signaling transfer point (STP)

Add OFI
> Signaling point code (SPC)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 46

Questions
z

Whats the sequence for hardware data conf.?

Which board will be added automatically after a


frame has been added?

How to make the data active in switch after we


configure the data offline?

What conditions are needed for E1 configuration?

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 47

Answer
z

1 Add shelf-> Add frame-> Add board->others

2 WSMUWALUPSM

Use FMT to format data. Use LON to set online. Then


load it.

We need add WCSU and WEPI at first.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 48

Chapter 1 Basic concepts


Chapter 2 Data configuration
Chapter 3 Relative maintenance command
Chapter 4 Configuration example

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 49

Chapter 3 Relative maintenance command


3.1 Query Hardware
3.2 Query clock reference
3.3 Query E1/CPC configuration
3.4 Query IP link
3.5 Query IMA/UNI link
3.6 Query Port Status
3.7 Query Local Office

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 50

Query The Hardware


z

LST SHF

Example:
z

LST FRM

Example:
z

LST SHF: SN=0;

LST FRM: FN=0, SN=0;

DSP FRM

Example:

DSP FRM: FN=0;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 51

Query The Hardware


z

LST BRD

Example:
z

LST BRD: FN=0, SN=0, LOC=FRONT;

DSP BRD

Example:

DSP BRD: FN=0, SN=0, PSN=FB;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 52

Query clock reference


z

LST CKICFG

Example:
z

DSP CLKPH

Example:
z

LST CKICFG:;

DSP CLKPH: FN=0;

DSP BRD (Query status of clock reference)

Example:

DSP BRD: FN=0, SN=13, PSN=BB;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 53

Query E1/CPC configuration


z

LST EPICFG

Example:
z

DSP BRD

Example:
z

DSP BRD: FN=0, SN=0, PSN=BB;

Display E1 status

Example:
z

LST EPICFG: FN=0, SN=0;

DSP PORT: FN=0, SN=0, PT=E1, E1PN=2;

LST CPCCFG

Example:

LST CPCCFG: FM=22, LOC=UPMC;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 54

Query IP link
z

List FE configuration

Example:
z

LST FECFG: MN=134;

Display FE status

Example:

DSP PORT: FN=0, SN=10, PT=FE, FEPN=2;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 55

Query IMA/UNI link


z

List IMA link configuration

Example:
z

LST IMALNK: MN=132, IGN=1, IPN=0;

Display IMA link status

Example:

List UNI link configuration


Example:

DSP IMALNK: MN=132, IGN=1, IPN=0;

LST UNILNK: MN=133;

Display UNI link status


Example:

LST UNILNK: MN=133;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 56

Query Port Status (MEM FE)


To check connection between SAU and HDU
z

List MEMFE link configuration

Example:
z

LST MEMCFG: MN=22;

Display MEMFE link status

Example:

DSP MEMFE: MN=22;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 57

Query Local Office Information


z

List local office information

Example:

LST OFI;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 58

Questions
z

Whats the difference between LST and DSP?

Which command is to check current clock reference?

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 59

Answer
z

LST is for query static data; DSP is for query the status of
frame/board etc.

DSP BRD is used to check current clock reference. (Board is


active WCKI)

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 60

Summary

HUAWEI TECHNOLOGIES CO., LTD.

After hardware data


configuration, please load it to
switch. Then query whether the
status of hardware is normal.

All rights reserved

Page 61

Chapter 1 Basic concepts


Chapter 2 Data configuration
Chapter 3 Relative maintenance command
Chapter 4 Configuration example

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 62

Example for hardware


z

IP address of WIFM: 191.169.100.10;

Mask: 255.255.0.0;

Gateway: 191.169.1.2

A
M

10

11

12

13

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

14

15

16

Page 63

17

18

19

20

Example
Item
Signaling
point
Mobile
network
information

MAP
information

Configuration data
Network Identify

Network structure

SPC

National

24bits

EE0

Local GT

Country code

Area code

8613807550000

86

755

Support of USSD
function value

MAP version 0902620

Not support CAMEL


phrase 1

Maximum times of
Call Forward

True

False

False

Support of Message
waiting information

Cancel SC

Repetition times of
ALERT_SC fail

Forwarded area
limitation

True

False

NORESTRICTION

Number structure
limitation

MAP version

Anytime interrogation
support

Support of PSI value

NORESTRICTION

GSM PHASE2

True

True

Support of GPRS short


message
True

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 64

Example for hardware


z

1 set offline mode

Offline
-----------------------LOF:;
Turn off alarm switch
-----------------------SET CWSON: SWT=OFF;
Turn off format switch
------------------------

SET FMT: STS=OFF


HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 65

Example for hardware


z

2 Add Hardware

Add shelf
-----------------------ADD SHF: SN=0, LT="HW_TC", PN=0, RN=0, CN=0;
Add frame
-----------------------ADD FRM: FN=0, SN=0, PN=2, CF=YES;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 66

Example for hardware


Add WCSU board
-----------------------ADD BRD: FN=0, SN=0, LOC=FRONT, BT=WCSU, MN=22, ASS=1;
Add WEAM board
-----------------------ADD BRD: FN=0, SN=4, LOC=FRONT, BT=WEAM, MN=140,
LNKT=LINK_2M;
ADD BRD: FN=0, SN=5, LOC=FRONT, BT=WEAM, MN=141,
LNKT=LINK_2M;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 67

Example for hardware


Add WEPI board
-----------------------ADD BRD: FN=0, SN=0, LOC=BACK, BT=WEPI;
ADD BRD: FN=0, SN=1, LOC=BACK, BT=WEPI;
ADD BRD: FN=0, SN=4, LOC=BACK, BT=WEPI;
ADD BRD: FN=0, SN=5, LOC=BACK, BT=WEPI;
Add WIFM board
-----------------------ADD BRD: FN=0, SN=10, LOC=FRONT, BT=WIFM, MN=132, ASS=11;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 68

Example for hardware


Add WCCU board
-----------------------ADD BRD: FN=0, SN=2, LOC=FRONT, BT=WCCU, MN=23, ASS=3;
Add WBSG board
-----------------------ADD BRD: FN=0, SN=12, LOC=FRONT, BT=WBSG, MN=133;
ADD BRD: FN=0, SN=13, LOC=FRONT, BT=WBSG, MN=134;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 69

Example for hardware

Add WCKI board


-----------------------ADD BRD: FN=0, SN=13, LOC=BACK, BT=WCKI;
ADD BRD: FN=0, SN=15, LOC=BACK, BT=WCKI;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 70

Example for hardware


z

3Configure E1/CPC/FE/ATM data

Configure E1 info
-----------------------ADD EPICFG: FN=0, SN=0, LC=CLK_8KA, E0=CRC4, E1=DF,
E2=DF, E3=DF, E4=DF, E5=DF, E6=DF, E7=DF, BM=BALANCE;
Configure CPC info
-----------------------MOD CPCCFG: FM=22, LOC=UPMC, LTYPE=LINK_64K;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 71

Example for hardware


Configure clock reference
-----------------------------SET CKICFG: CL=LEVEL2, WM=AUTO, B1P=L1, B2P=L2,
L1P=L3, L2P=L4, B1CST=CLK_2M, B2CST=CLK_2M;
Configure clock from E1
-----------------------------ADD BOSRC: FN=0, SN=0, EN=2;

Configure FE
-----------------------ADD FECFG: MN=132, IP="191.169.100.10", MSK="255.255.0.0",
DGW="191.169.1.2";

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 72

Example for hardware


Configure IMA link
-----------------------ADD IMAGRP: MN=140, IGN=0, IID=0, IVR=VER1.1;
ADD IMALNK: MN=140, IGN=0, IPN=0;
Configure PVC link
-----------------------ADD PVCLNK: PLN=0, VPI=2, VCI=4, SDMN=140, SHMN=133,
BT=IMA;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 73

Example for hardware


z

4: Set Local Office Data

Online
-----------------------SET OFI: OFN="HLR-TEST", LOT=CMPX, NN=YES, SN1=NAT,
SN2=NAT, SN3=NAT, SN4=NAT, NPC=EE00", NNS=SP14, STP=NO,
LAC=K755, LNC=K86, LOCGT=861380755", NETTYPE=GSM/PSTN;

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 74

Example for hardware


z

5: Format the data, load it


Online
-----------------------LON:;
Turn on alarm switch
-----------------------SET CWSON: SWT=ON;
Turn on format switch
-----------------------SET FMT: STS=ON;
Format the data
-----------------------FMT:;
Load the module one by one

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 75

Summary

After finish hardware data, trainees need


master the basic concepts of hardware.

Trainees need understand the steps of


SAU hardware data configuration

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 76

Thank You
www.huawei.com

You might also like