GUE, GUB Junction Boxes

6F

Ordering Information

Table 1/Arrangements of Drilled and Tapped Conduit Openings


For other arrangements, send sketch and complete description

108

109

Conduit opening arrangements


shown in the illustration should
meet the majority of
requirements.
These GUB junction boxes will
be supplied with drilled and
tapped openings up to the
maximum size and number
shown in Table 2.

110

111

Table 2/Maximum Size & No. of Drilled & Tapped Holes


Cat. #

Top & Bottom (bb)


1
2
3

GU
GUE
GUB01
GUB02
GUB06
GUB08
GUB03
GUB04
GUB01110
GUB15151

1
2
2
2
2
2
2
2
2
5

1
1
112
2
2
2
2
2
2
4

1
2
2
2
2
2
2
2
2
5

1
1
114
112
112
112
2
2
2
4

1
2
2
2
2
2
2
2
2
4

1
1
114
112
112
112
2
2
2
4

Group D*

Group C
GU
GUE
GUB01
GUB02
GUB06
GUB08
GUB03
GUB04
GUB01110
GUB15151

Group B
GU
GUE
GUB01
GUB02
GUB06
GUB08
GUB03
GUB04
GUB01110
GUB15151

34

1
1
1
112
112
2
312

34
34
34

1
1
112
212

12
34
34
34

114
114
2
3

34
34

114
2

12
34
34
34

114
114
2
312

34
34

114
212

Each Side (aa)


1
2
3
1
2
2
2
2
2
2
2
2
5

1
1
112
2
2
2
2
2
2
4

1
2
2
2
2
2
2
2
2
5

1
1
114
2
2
2
2
2
2
4

1
2
2
2
2
2
2
2
2
4

1
1
114
2
2
2
2
2
2
4

1
112
112
112
2
2
2
4

12

114
114
114
112
112
2
312

12

114
114
114
112
112
2
312

Table 3/Drilled & Tapped Holes


Size
12
34
1
114
112
2
212
3
312
4
none

STIBOINFO((CRH:MAIN:6F:121))
CH0 6 F - 1 1

12

1
1
1
114
114
2
3

12
12
12

1
1
2
212

12
12
12

1
1
2
212

Back
1

3
2
1
34
2
2
4
4
6
6

1
1
34
34
2
2
4
4
6
6

34

34

34

34

2
2
312
312
4
6

2
2
3
3
312
6

3
2
34
34
2
2
4
4
6
6

1
1
34
34
2
2
312
312
6
6

34

34

34

34

2
2
212
212
4
6

112
112
212
212
312
5

3
2
34
34
2
2
4
4
4
4

1
1
34
34
2
2
312
312
4
4

34

34

34

34

34
34

34
34

34
34

2
2
212
212
4
4

34
34

34
34

34
34

112
112
212
212
4
4

* Group D chart is based on use of staggered unions. If


adjacent unions are desired, additional spacing may be
necessary.

Symbol
A
B
C
E
F
G
H
J
K
L
0

Sidewall and top and bottom sizes are based on all


openings being in line.
Backwall sizes are based on: two per side diagonal
corners; four per side one in each corner; three per side
triangular pattern with two on adjacent corners on long wall
and third in center of opposite long wall.

Conduit seals are required within 112 of all conduit


entrances for Class I, Group C hazardous locations.
Conduit seals are required within 112 of all conduit
entrances for Class I, Group B hazardous locations.

NOTE: For conduit liner ordering information, see page 138.

Copyright 2002 Cooper Industries, Inc.

PDFINFO

121

Zoom: 100

You might also like