2 Technical specifications:
Dimmer outputs:
- 3 Dimmer outputs (Short-circuit protected)
(6way TB)
Relay outputs:
- 2 Relay Outputs
(4way TB)
Light On/Off:
- 5 Contact inputs to control dimmers and relays
(4way TB)
DS_YCS-230V_2.0.doc
Page 1 of 4
Max 4A each
Max: 6A 110-250Vac
01.08.2012
Datasheet
YCS-230V Cabin Control Unit
Fan Coil Output (YCS-230F version only):
- 1 A/C Fan output and 1 Valve output
(4way TB)
Max: 6A 110-250Vac
Dimmer outputs:
- 2 Dimmer outputs (Short-circuit protected)
(4way TB)
Network:
- Lantic Link (for interconnecting LCD touch panels,
YCS server, CCS relays other YCS-230s)
- Optional DALI link (for controlling DALI compatible devices)
Power Inputs:
- Separate power inputs for Dimmers, Relays and Heater/Fan Coil
Maximum ambient temperature:
Standby power consumption with one LCD panel:
~15W.
Maximum power consumption @115VAC (full load on all outputs):
feeds)
Maximum power consumption @230VAC (full load on all outputs):
feeds)
Mains supply: Internal selection between
Maximum heat generation:
Net Weight: model YCS-230H+YCS230F+YCS230-D5:
RS-485
(3 x 2way TB)
<40 C/104F
~3200W. (3 supply
~5800W. (3 supply
115VAC & 230VAC.
~50W.
2.6 kg.
Product Description
1512
1513
1514
1517
DS_YCS-230V_2.0.doc
Page 2 of 4
01.08.2012
Datasheet
YCS-230V Cabin Control Unit
Bottom View:
Top View:
4 Mounting dimensions
DS_YCS-230V_2.0.doc
Page 3 of 4
01.08.2012
Datasheet
YCS-230V Cabin Control Unit
5 Mounting suggestion
6 DALI interface
The Dali Link is a two wire interface for third party dimmer modules. The Dali Link is located on PL15 on the YCS unit.
It is mandatory that an external +24V power supply is connected as displayed in below example.
DS_YCS-230V_2.0.doc