You are on page 1of 2

Step 1 - Traffic Balance between 3G Layers

MOD UCELLSELRESEL: CellId=high load cell, IdleSintersearch=6;


MOD UINTERFREQNCELL: RNCId=XXXX, CellId=High load cell, NCellRncId=XXXX,
NCellId=Low load Cell, SIB11Ind=TRUE, IdleQoffset1sn=0, IdleQoffset2sn= -5;
Parameter Name
UCELLSELRESEL
UINTERFREQNC
ELL
UINTERFREQNC
ELL
UINTERFREQNC
ELL

Sub Parameter
IdleSintersearc
h

Value

SIB11Ind

TRUE

IdleQoffset1sn
IdleQoffset2sn

SE Parameter Baseline

0
5

MOD UINTERFREQNCELL: RNCId=XXXX, CellId=low load cell, NCellRncId=XXXX,


NCellId=high load Cell, SIB11Ind=TRUE, IdleQoffset1sn=0, IdleQoffset2sn=3;
Parameter Name
UINTERFREQNC
ELL
UINTERFREQNC
ELL
UINTERFREQNC
ELL

Sub Parameter

Value

SIB11Ind

TRUE

IdleQoffset1sn
IdleQoffset2sn

0
3

Note (The load in the same sector can be adjusted. M2000 1 min monitoring can be
used to analyse the load balancing has been triggered) .

Step 2 - Reduce Pilot power to 5% of the maximum power


LST UPCPICH: CellId=xxxxx; (To check CPICH Usually CPICH is around 360)
MOD UCELL: CellId=xxxxx, PCPICHPower=330;
Parameter Name

Value

PCPICHPOWER

330

Trigger when cells have been detected as bad access performance due to
resource limitation. RRC Congestion rate is more than 10% and CS blocking rate
is more than 5%.

Reduce pilot power to 5% of maximum power gradually in step size of 1db.

Note (When reducing the CPICH all the cells (layers) in the sector have to be on same
level for example if degradation is observed on 209682_SurryHillsNorth_MO_U21A_3
and CPICH has to be reduced it will be done for both carriers
209682_SurryHillsNorth_MO_U21A_3 and 209682_SurryHillsNorth_MO_U21B_3.

Step 3 - Traffic Shifting From 3G-2G


MOD UCELLSELRESEL: CellId=xxxxx, SsearchRat=3;
SET GCELLCCUTRANSYS: IDTYPE=BYID, CELLID=***, FDDQMIN=5;
executed on the BSC MML)
Parameter Name

Sub Parameter

UCELLSELRESEL

SsearchRat

Value
3

SE Parameter Baseline
1

(2G Command have to be

GCELLCCUTRANS
YS

FDDQMIN

Step 4 Push More traffic from 3G - 2G


MOD UCELLSELRESEL: CellId=xxxxx, SsearchRat=4;
MOD UCELLINTERRATHOCOV: CellId=*****, InterRATCSThd2DEcN0=-10,
InterRATCSThd2FEcN0=-8;
SET GCELLCCUTRANSYS: IDTYPE=BYID, CELLID=***, FDDQMIN=3;

(2G Command have to be

executed on the BSC MML)


Parameter Name

Sub Parameter

UCELLSELRESEL
UCELLINTERRATH
OCOV
UCELLINTERRATH
OCOV

SsearchRat
InterRATCSThd2D
EcN0
InterRATCSThd2F
EcN0

GCELLCCUTRANSY
S

FDDQMIN

Valu
e

SE Parameter
Baseline

-10

-12

-8

-10

Works great with GSM co-site can also be implemented on the tier 1 neighbours than
other GSM neighbouring cells can be changed according to the congestion.

Step 5 - Modify the minimum of cell access EcIo


LST UCELLSELRESEL:CELLID=XXXX; (Base line values, Min quality level = -18 and Min Rx
level = -58)
MOD UCELLSELRESEL: CellId=XXXXX, QualMeas=CPICH_ECNO, Qqualmin=-14, Qrxlevmin=52;
Parameter Name
UCELLSELRESE
L
UCELLSELRESE
L
UCELLSELRESE
L

Sub Parameter
QualMeas

Value
CPICH_EC
NO

Qqualmin

-14

Qrxlevmin

-52

Note (The modification should be according to distance between SE areas to the


related site, only the very near Main SE site can be modified. Otherwise, it will impact
the user experience. This parameter should only be implemented as a last resort and
extreme values can be changed to Qrxlev = -50, Qqualmin=-14.

You might also like