Alt 1: WARNING: 10 required coil(s) found with either their capacity set to zero
or scheduled off for the entire year!
Alt 1: **Note: In Trace some systems have preheat or reheat coils which, in re ality, are handled by a single main heating coil. Alt 1: **For these system types, the preheat or reheat capacity override and s chedule refer to the functional mode of the Alt 1: **of the main heating coil, not a physical coil, so errors may occur in the simulation if you try to delete them. Alt 1: Alt 1: Sys 1: "AHU-1 KITCHEN DINING LEVEL 01" has detected 2 needed reheat and/ or preheat coils that have been deleted! Alt 1: The Preheat Coil for this system has its capacity set to zero! Alt 1: The Reheat Coil for this system has its capacity set to zero! Alt 1: Sys 2: "AHU-4 BLD A LEVEL 02 & 03 W" has detected 2 needed reheat and/or preheat coils that have been deleted! Alt 1: The Preheat Coil for this system has its capacity set to zero! Alt 1: The Reheat Coil for this system has its capacity set to zero! Alt 1: Sys 3: "AHU-5 BLD A LEVEL 02 & 03 E" has detected 2 needed reheat and/or preheat coils that have been deleted! Alt 1: The Preheat Coil for this system has its capacity set to zero! Alt 1: The Reheat Coil for this system has its capacity set to zero! Alt 1: Sys 4: "AHU-2 IT OFFICES LEVEL 01" has detected 2 needed reheat and/or p reheat coils that have been deleted! Alt 1: The Preheat Coil for this system has its capacity set to zero! Alt 1: The Reheat Coil for this system has its capacity set to zero! Alt 1: Sys 5: "AHU-3 ONE STOP LEVEL 02" has detected 2 needed reheat and/or pre heat coils that have been deleted! Alt 1: The Preheat Coil for this system has its capacity set to zero! Alt 1: The Reheat Coil for this system has its capacity set to zero! Alt 1: