You are on page 1of 19

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Sizing and Rating of Trays


and Packing
Advanced Distillation with Aspen Plus

2002 AspenTech. All Rights Reserved.

Lesson Objectives
Learn about:
- Tray Efficiencies
- Sizing (Design) of Trays and Packing
- Rating of Trays and Packing

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-1

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

RadFrac Efficiencies
Efficiency type
- Overall efficiency
- Vaporization efficiencies
- Murphree efficiencies

Can be specified
- Overall
- By stage
- For column sections
- For individual components

2002 AspenTech. All Rights Reserved.

Overall Efficiency
Direct conversion of actual trays to theoretical plates.
Not directly input to model; instead Overall Efficiency
sets the number of stages in the RadFrac block.
Example:
- Column with condenser, reboiler and 30 trays
- At 70% efficiency, 30 trays = 21 theoretical stages
- Add stages for condenser and reboiler => 23 total

Most common, but least flexible method.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-2

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Vaporization Efficiency
At equilibrium:
With efficiency:

Ki ix
i K i ix

Efficiency should be different for different components.


As decreases, the vapor pressure must increase which
means that the temperature must increase.
Using vaporization efficiency alters the T profile and this
may alter relative volatility.
In general it is better to use Murphree efficiencies.

2002 AspenTech. All Rights Reserved.

Murphree Efficiency

Eff

M
i, j

y
i, j i, j 1

y
K i, j x
i, j i, j 1

Strictly, this is a Murphree vapor efficiency.


Subscripts are i for components and j for stages.
Many correlations exist for Murphree efficiencies

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-3

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Specifying Efficiencies in the Column


RadFrac Efficiencies Options sheet
Do not specify efficiencies in both the column and in the tray
rating forms

2002 AspenTech. All Rights Reserved.

The Problem with Efficiency


Efficiencies vary enormously - they can be under 10% or over
100%.
Efficiencies vary with composition, with purity, and with
location in the column.
Efficiencies are different for different components.

Next to physical properties, this is the most important


thing to know to successfully model a column.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-4

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Determining Column Efficiency


Previous experience.
- Be sure experience is comparable

Generalized correlations.
Fit to plant data.
- Use Data-fit to regress Murphree efficiency to data

RateFrac can be used to calculate efficiencies.


- RateFrac calculates actual separation
- Efficiency backed out from calculated compositions

Vendor packages.
2002 AspenTech. All Rights Reserved.

HETP
Comments similar to those for tray efficiency
- It is important
- It is hard to know well

RateFrac can be used to calculate HETP.


- RateFrac calculates actual separation for specified height of

packing
- Separation is converted to NTU, and NTU to HTU

Use of vendor data is common.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-5

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Sizing and Rating for Trays and Packing (1)


Aspen Plus has extensive capabilities to size, rate, and
perform pressure drop calculations for trayed and
packed columns.
The calculations are based on vendor-recommended
procedures when available. When vendor procedures
are not available, well-established literature methods are
used.
You can use the computed pressure drop to update the
column pressure profile.

2002 AspenTech. All Rights Reserved.

Sizing and Rating for Trays and Packing (2)


Rating Mode
- Specify column section diameter and other tray or packing

details.
- Model calculates performance and hydraulic information such

as flooding approach, downcomer backup, and pressure drop.

Sizing Mode
- Model determines column diameter to satisfy the flooding

approach or pressure drop* specified for each stage. The


largest diameter is selected.

*pressure drop specification valid for packed columns only

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-6

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Sizing and Rating for Trays and Packing (3)


For sizing and rating calculations, column is divided into
sections
- Each section can have a different tray type, packing type, and

diameter.
- The tray details can vary from section to section.
- A column can have an unlimited number of sections.
- You can size and rate the same section with different types of

trays and packing.

2002 AspenTech. All Rights Reserved.

Sizing and Rating for Trays and Packing (4)


Aspen Plus calculates sizing and performance
parameters such as:
- Column diameter
- Flooding approach or approach to maximum capacity
- Downcomer backup
- Pressure drop

These results are based on:


- Column loadings (vapor and liquid traffic)
- Tray geometry or Packing characteristics
- Transport properties

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-7

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Sizing and Rating for Trays and Packing (5)


Use the following Tray/Packing forms to enter
specifications:
- Tray Sizing
- Tray Rating
- Pack Sizing
- Pack Rating

These capabilities are available in the following column unit


operation models:
- RadFrac
- MultiFrac
- PetroFrac

2002 AspenTech. All Rights Reserved.

Example: RadFrac Tray Rating


Using the MEG column example, add tray rating
calculations for the following configured trays:
All Bubble Cap Trays
One pass tray
Tray Spacing: 2 ft
Diameter: 5 ft
Cap diameter: 3 in

FILENAME: EX1B-MEG-COL-TRAYRATE.BKP
2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-8

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Tray Types
You can choose from the following five commonly-used tray
types:
- Bubble caps
- Sieve
- Glitsch Ballast

- Koch Flexitray

- Nutter Float Valve

2002 AspenTech. All Rights Reserved.

Packing Types
Aspen Plus can model a variety of random packings.
You can also use any of the following types of structured
packings:
- Goodloe

- Glitsch Grid

- Norton Intalox Structured Packing


- Sulzer BX, CY, Mellapak, and Kerapak
- Super-Pak and Ralu-Pak
- Koch Flexipac, Flexeramic, Flexigrid

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3-9

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Trays (1)
When specifying Weir heights, cap positioning, and number of
valves:
For Specify
One-pass tray A single value
Two-pass tray

Up to two values, one for each panel


A and B

Three-pass tray

Up to three values, one for each panel


(A, B and C)

Four-pass tray

Up to four values, one for each panel


(A, B, C and D)

2002 AspenTech. All Rights Reserved.

Trays (2)
The values for the number of caps and number of valves
applies for each panel. For example, two -pass trays
have two A panels for tray AA, and two B panels for tray
BB. Therefore, the number of caps per panel is the
number of caps per tray divided by two. Similar
consideration is necessary for three- and four -pass trays.
If you specify only one value for multi-pass trays, that
value applies to all panels.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 10

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Trays (3)
When specifying downcomer clearance and width:
For Specify
One-pass tray A single value for the side downcomer
Two-pass tray

Up to two values, one for the side


downcomer, one for the center
downcomer

Three-pass tray

Up to two values, one for the side


downcomer, one for the off-center
downcomer

Four-pass tray

Up to three values: one for the side


downcomer, one for the center
downcomer, and one for the off-center
downcomer

2002 AspenTech. All Rights Reserved.

One Pass Tray

Outlet Weir Length

Column Diameter

DC-WTOP
WEIR-HT
DCWBOT

DC-HT

DC-CLEAR

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 11

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Two Pass Tray

Outlet Weir Length

Column Diameter

CTR. DC

DC-WTOP

CTR. DC
Below

~
DCWBOT

Panel A

WEIR-HT
DC-HT
DCWTOP

DC-CLEAR

Tray AA
Side
Downcomer

Panel B Tray BB
DC-HT

DCWBOT

Center
Downcomer

DC-CLEAR

~~

~ ~
2002 AspenTech. All Rights Reserved.

Three Pass Tray

Outlet Weir Length

Column Diameter
OFF-CTR.DC

OFF-CTR.DC
DC-WTOP

DC-WTOP

WEIR-HT
DC-HT

Panel A. B. C.
DCOF
DC-WBOT

DC-

DC-WTOP

CLEAR

Panel C. B. A.

Panel A. B. C.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 12

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Four Pass Tray

Outlet Weir Length

Column Diameter
OFF-CTR.DC OFF-CTR.DC

SIDE DC

CTR.DC
DC-WTOP

DC-WTOP

WEIR-HT
DC-HT

Panel A. B.
DC-WBOT

DC-

CLEAR

DC-WBOT

C
DCOF

Panel C. D.

Panel A. B.

2002 AspenTech. All Rights Reserved.

Specifying Efficiencies in Tray Rating (2)


If specifying Murphree or Vaporization efficiency, each stage in
RadFrac corresponds to one actual tray. Calculated pressure drops will
be correct.
If using Overall efficiency, each stage in RadFrac will correspond to
more than one physical tray. To calculate the column pressure drop,
the assumed overall efficiency must be specified on the Tray Rating
Design/Pdrop sheet.
Specify efficiency on either the Efficiencies form or on the Tray
Rating form but not both.

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 13

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Specifying Efficiencies in Tray Rating (2)


Specified on Tray Rating Design/Pdrop sheet when column
simulation is based on overall efficiency.

2002 AspenTech. All Rights Reserved.

Example: RadFrac Pack Sizing (1)


Working with EB/Styrene example, add Packed Column Sizing
information:
Packing Type

Norton IMTP 2 in.

HETP

1.5 ft.

Approach to Flooding

80%

Maximum Pressure Drop

55 torr

FILENAME: EX1A-EBSTRYRENE-PACKSIZE.BKP

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 14

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Example: RadFrac Pack Sizing (2)


Packed Column Sizing Input:

2002 AspenTech. All Rights Reserved.

Example: RadFrac Pack Sizing (3)


Packed Column Sizing Input:

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 15

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Example: RadFrac Pack Sizing (4)


Packed Column Sizing Input:

2002 AspenTech. All Rights Reserved.

Example: RadFrac Pack Sizing (5)


Packed Column Sizing Results:

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 16

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Example: RadFrac Pack Sizing (6)


Packed Column Sizing Results:

2002 AspenTech. All Rights Reserved.

Workshop 2A: HCL Column Rating (1)


Use Workshop 1, perform tray rating. Tray details:
Tray type
Nutter float Valve BDH
Number of passes
2
Column diameter
7 ft.
Actual number of trays
66
Tray spacing
1.5 ft.
Tray efficiency
0.5
Weir height
2 in.
Valve density
12/sq.ft.
Downcomer clearance
1.5 in.
Side downcomer width
8.7 in.
Center downcomer width
7.1 in.
FILENAME:WS2A-HCLCOL-RATE.BKP

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 17

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Workshop 2A: HCL Column Rating Results (2)


Condenser Duty
Reboiler Duty
Maximum flooding factor
Maximum DCBA
Predicted P drop

-9.837 MMBtu/hr
10.927 MMBtu/hr
0.329 (Stage 2)
0.384 (Stage 32)
5.65 psi

2002 AspenTech. All Rights Reserved.

Workshop 2A: HCL Column Rating Results (3)

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 18

Aspen Technology, Inc.

Advanced Distillation with Aspen Plus

Sizing and Rating of Trays and Packing

Workshop 2B: Increased Throughput (1)


Sensitivity Analysis
Study the effect of an increase in flow rate
on the flooding approach and downcomer/
backup tray spacing. Consider increases of
5 to 50%. Use a Multiplier block to handle the
feed variation.

HCL-PROD

HCL-COL

FEEDA

FEEDB
MULT
VCM-EDC

FILENAME:WS2B-HCLCOL-FLOW.BKP
2002 AspenTech. All Rights Reserved.

Workshop 2B: Increased Throughput (2)


Results:

2002 AspenTech. All Rights Reserved.

2002 AspenTech. All Rights Reserved.

3 - 19

Aspen Technology, Inc.

You might also like