Professional Documents
Culture Documents
Lesson Objectives
Learn about:
- Tray Efficiencies
- Sizing (Design) of Trays and Packing
- Rating of Trays and Packing
3-1
RadFrac Efficiencies
Efficiency type
- Overall efficiency
- Vaporization efficiencies
- Murphree efficiencies
Can be specified
- Overall
- By stage
- For column sections
- For individual components
Overall Efficiency
Direct conversion of actual trays to theoretical plates.
Not directly input to model; instead Overall Efficiency
sets the number of stages in the RadFrac block.
Example:
- Column with condenser, reboiler and 30 trays
- At 70% efficiency, 30 trays = 21 theoretical stages
- Add stages for condenser and reboiler => 23 total
3-2
Vaporization Efficiency
At equilibrium:
With efficiency:
Ki ix
i K i ix
Murphree Efficiency
Eff
M
i, j
y
i, j i, j 1
y
K i, j x
i, j i, j 1
3-3
3-4
Generalized correlations.
Fit to plant data.
- Use Data-fit to regress Murphree efficiency to data
Vendor packages.
2002 AspenTech. All Rights Reserved.
HETP
Comments similar to those for tray efficiency
- It is important
- It is hard to know well
packing
- Separation is converted to NTU, and NTU to HTU
3-5
details.
- Model calculates performance and hydraulic information such
Sizing Mode
- Model determines column diameter to satisfy the flooding
3-6
diameter.
- The tray details can vary from section to section.
- A column can have an unlimited number of sections.
- You can size and rate the same section with different types of
3-7
FILENAME: EX1B-MEG-COL-TRAYRATE.BKP
2002 AspenTech. All Rights Reserved.
3-8
Tray Types
You can choose from the following five commonly-used tray
types:
- Bubble caps
- Sieve
- Glitsch Ballast
- Koch Flexitray
Packing Types
Aspen Plus can model a variety of random packings.
You can also use any of the following types of structured
packings:
- Goodloe
- Glitsch Grid
3-9
Trays (1)
When specifying Weir heights, cap positioning, and number of
valves:
For Specify
One-pass tray A single value
Two-pass tray
Three-pass tray
Four-pass tray
Trays (2)
The values for the number of caps and number of valves
applies for each panel. For example, two -pass trays
have two A panels for tray AA, and two B panels for tray
BB. Therefore, the number of caps per panel is the
number of caps per tray divided by two. Similar
consideration is necessary for three- and four -pass trays.
If you specify only one value for multi-pass trays, that
value applies to all panels.
3 - 10
Trays (3)
When specifying downcomer clearance and width:
For Specify
One-pass tray A single value for the side downcomer
Two-pass tray
Three-pass tray
Four-pass tray
Column Diameter
DC-WTOP
WEIR-HT
DCWBOT
DC-HT
DC-CLEAR
3 - 11
Column Diameter
CTR. DC
DC-WTOP
CTR. DC
Below
~
DCWBOT
Panel A
WEIR-HT
DC-HT
DCWTOP
DC-CLEAR
Tray AA
Side
Downcomer
Panel B Tray BB
DC-HT
DCWBOT
Center
Downcomer
DC-CLEAR
~~
~ ~
2002 AspenTech. All Rights Reserved.
Column Diameter
OFF-CTR.DC
OFF-CTR.DC
DC-WTOP
DC-WTOP
WEIR-HT
DC-HT
Panel A. B. C.
DCOF
DC-WBOT
DC-
DC-WTOP
CLEAR
Panel C. B. A.
Panel A. B. C.
3 - 12
Column Diameter
OFF-CTR.DC OFF-CTR.DC
SIDE DC
CTR.DC
DC-WTOP
DC-WTOP
WEIR-HT
DC-HT
Panel A. B.
DC-WBOT
DC-
CLEAR
DC-WBOT
C
DCOF
Panel C. D.
Panel A. B.
3 - 13
HETP
1.5 ft.
Approach to Flooding
80%
55 torr
FILENAME: EX1A-EBSTRYRENE-PACKSIZE.BKP
3 - 14
3 - 15
3 - 16
3 - 17
-9.837 MMBtu/hr
10.927 MMBtu/hr
0.329 (Stage 2)
0.384 (Stage 32)
5.65 psi
3 - 18
HCL-PROD
HCL-COL
FEEDA
FEEDB
MULT
VCM-EDC
FILENAME:WS2B-HCLCOL-FLOW.BKP
2002 AspenTech. All Rights Reserved.
3 - 19