500mW LED Bulb Testing

Setup We have provided 220 Volts AC Input to the SPEA-1 source and connects
the 0.5W led bulb at load. Micro SD Card is inserted in SPEA-1. For real time data
viewing we have connected SPEA-1 to the software through USB

Image 1
We have taken a 0.5 Watt led bulb for Testing. To view connection diagram Click here
http://embuilt.com/tech/products/spea-1/spea1connectiondiagram.

Image 2
In the above Image Vrms, Arms, W, VTHD, ATHD, and serial no is showing. SPEA-1 is in
production mode. As per image in display column 1 Vrms is 221.4Volts, Arms is
14.43mAand Watt is 0.332 watt. In Display column 2 VTHD% is 1.2 and AmpTHD% is
19.7.
In the lower display serial no of testing model shows which is 1124. THD TYPE LEDs
and PERCENT LEDs are OFF. This also shows that SPEA-1 is in production mode. (Mode
has been discussed on HOME page). You can also view more information on SPEA-1
Details .

Image 3
In the above image SPEA-1 is in R&D mode.In display column 3, Left side shows
harmonics value/Percent and right side shows serial no or level of harmonics. Last
display so Harmonics is showing in place of Serial No. Harmonics type is Voltage and
image shows the value of 3rd harmonic.

Image 4
In the above image after pressing Mode button Average values of Voltage and Current
are showing.

Image 5

In above Image Peak values of Voltage and current shows.

Image 6
In the above image Crest factor of Voltage and current shows.

Image 7
In the above image Form Factor of voltage and current shows.

Image 8
In the above image Power factor shows in display 3.In the above image Frequency is
shows in display 3.

Image 9
In the above display Watt hour reading shows. Watt hour read can be reset using
button.

Image 10
In the above display Value of 3rd Harmonic of Ampere shows.