Calculation For Reinforced Pad
Calculation For Reinforced Pad
Page 1 of 4
Type : Lease.
EXCLUSIONS
(1) Packaged Equipment Piping. Piping which interconnects individual pieces or stages of
equipment within a packaged equipment assembly shall be in accordance with B31.3, except that
packaged refrigeration piping may conform to either B31.3 or B31.5.
(2) This Calculation Method excludes the following:
Piping systems designed for internal gage pressures at or above zero but less than 15 psi (103 kP)
http://www.copcoltd.com/soft/mecheng07/rob3.htm
6/18/2011
Page 2 of 4
provided the fluid handled is nonflammable, nontoxic, and not damaging to human tissue as defined in
para 300.2, and its design temperature is from -20F (-29C) through 366F (186C);
power boilers in accordance with BPV Code Section I and boiler external piping which is required to
conform to B31.1;
tubes, tube headers, crossovers, and manifolds of fired heaters, which are internal to the heater
enclosure;
pressure vessels, heat exchangers, pumps, compressors, and other fluid handling or processing
equipment, including internal piping and connections for external piping;
piping located on company property which has been set aside for pipelines conforming to B31.4 or B31.8
or applicable governmental regulations;
plumbing, sanitary sewers, and storm sewers; and
fire protection systems constructed in compliance with insurance underwriters' or other recognized fire
protection engineering standards.
Notes:
- This method applies ASME CODE B31.3 para.304.1.2 (a) "Pressure Design of Metallic Components".
- For t>=D/6 (t:Required thickness of the pipe, D:Outside Diameter of the pipe), Calculation of pressure
design thickness for straight pipe requires special consideration of factors such as theory of failure, and
thermal stress.
- This method is not applicable for high Pressures. (High Pressure: Pressure in excess of that allowed by the
ANSI B16.5 Class 2500 rating for the specified design temperature and material group).
http://www.copcoltd.com/soft/mecheng07/rob3.htm
6/18/2011
Page 3 of 4
your name
Company :
Date :
01
Client :
APR
2002
Case :
Reference :
UNITS
F
Ferritic Steels
in
in
http://www.copcoltd.com/soft/mecheng07/rob3.htm
6/18/2011
Page 4 of 4
Material :
Allowable Stress :
psi
Allowable Stress :
psi
Branch features
Outside diameter of Branch
(Db) :
Nominal Thickness ( ) :
in
in
Material :
Allowable Stress :
psi
Allowable Stress :
psi
Corrosion Allowance :
0.0625
in
Erosion Allowance :
Mechanical Allowances :
in
in
0.85
(0.0 - 1.0)
90
deg. (0 - 90)
psi
refresh
http://www.copcoltd.com/soft/mecheng07/rob3.htm
6/18/2011