KUWAIT OIL COMPANY (K.S.C.) @ if i NGINEERING iC} RAWING iJ RACTICE lI ODE 49 Engineering Group | November,2007 DOC.No.EG-DO-C-001 PAGE 1 OF 109 REV.0 (Spgs) Cig dats a5 cs KUWAIT OIL COMPANY (K:.S.C.) ENGINEERING DRAWING PRACTICE CODE DOC. No. EG-DO-C-001 Engineering Group Design Team \ ISSUED AS 11-11-07 | ENGINEERING ‘GROUP CODE ENGINEERING GROUP. DESIGN TEAM (DRAWING OFFICE) 1. QQ.ad: ie Shia [tbrahim Al-Awadhi ‘Amina Rajab Yousuf Ahmad All Rev pate | DESCRIPTION PREPARED BY SNR. ENGINEER (ORAWING OFFICE) TEAM LEADER (DESIGN TEAM) MANAGER (ENGINEERING GROUP} DOC.No.EG- DO-C-001 PAGE 2 OF 109 REV.0 TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 SCOPE 3.0 GENERAL DRAFTING PRACTICE 34 3.2 33 34 35 3.6 37 38 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 Presentation General Piping Guidelines General Dimensioning Guidelines Colour Coding for checking Dimensioning Samples Drawing Scales Graphic Scales Location Plan Key Plan Section Indicators North Arrow Layouts, Surveys, Site and Location Plans Piping and Civil Drawings (Other than those for Buildings) Architectural and Associated Plans Isometric and North Arrow Nozzle Orientation Orthographic Projection 3.17.1 Plan 3.17.2. Elevation 4,0 KOC DRAWING NUMBERING SYSTEM 4a 42 43 44 General KOC P&ID Numbering System Equipment Numbering System Line Numbering System DOC.No.EG-DO-C-001 PAGE 3 OF 109 REV.O 6.0 7.0 TABLE OF CONTENTS DRAWING FRAMES & TITLE BLOCK 5.1 Specimen of Drawing Frames & Title Block 5.2 Drawing Title Panel (KOC) 5.3. Folding of Drawings CAD LAYER SPECIFICATIONS 6.1 Piping and Instrumentation 6.2 Piping 6.3 Electrical 6.4 Civil / Architectural 6.5 Heating Ventilation & Air Conditioning LINE CHARACTERISTICS 7A Piping drawing 7.2 Piping & Instrument Diagrams, Process Flow Diagrams and Signal lines SYMBOLS & ABBREVIATIONS 8.1 Piping and Instrument Diagram (P & ID) Symbols 8.1.1 Equipment Identification Prefixes 8.1.2 Fluid Designation 8.1.3 _ Insulation Designation (For Piping/Equipment) 8.1.4 Line Continuations 8.1.5 Instrument Tag Number Identification / Instrument Identification 8.1.6 __ Instrument Line Symbols 8.1.7 __ Instrument Symbols (Local) 8.1.8 Local/Local Panel / Packaged Unit Panel 8.1.9 Distributed Control System 8.1.10 Programmable Logic Controllers 8.1.11 Scada System DOC.No.EG-DO-C-001 PAGE 4 OF 109 REV.0 1.13 1.14 1.15 1.16 1.17 1.18 oan nna a ow 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1,28 1.29 1.30 DD a nnnn nna ow 8.1.31 TABLE OF CONTENTS Miscellaneous Level Instruments Temperature Instruments Pressure Instruments Flow Instruments Miscellaneous Symbols For P&ID Valves For Piping & Instrument Diagram Equipment a) Vessels b) Filters c) Tanks d) Heat Exchangers e) Pumps f) Mixing Devices 9) Compressors/ Blowers/Fans/ Ejectors h) Drivers J) P&ID Abbreviations k) Instrument identification letters Instrument Valves for P8ID Instrument Valves for P&ID (Safety) Typical Instrument Connections Typical Shutdown & Vent Valves Safety Blowdown Valve, Emergency Shutdown Valve Motor Operated Valves Motor Instrumentation Sample Connection Arrangements Injection & Sample Nozzle Corrosion Coupon Typical Pump Casing Vents & Drains on Suction Discharge Lines & Base Plate Drains Standard Hydrant & Fire Engine Suction Riser DOC.No.EG-DO-C-001 PAGE 5 OF 109 REV.0 8.2 8.3 84 85 8.6 8.7 8.8 8.9 8.10 TABLE OF CONTENTS Piping Symbols 8.2.1 8.2.2 8.2.3 8.2.4 Piping Fittings Valves Type of Operators for Valves Type of Pipe Supports Piping Abbreviations Piping Legends Electrical Symbols 8.5.1 8.5.2 8.5.3 8.5.4 8.5.5 8.5.6 8.5.7 8.5.8 Power Schematic and Single Line Diagram Lighting Telecommunication Fire Alarm System Earthing Building Relays and Metering Electrical Abbreviations Civil / Architectural Symbols 8.7.1 8.7.2 8.7.3 8.7.4 8.7.5 8.7.6 8.7.7 General Doors Windows Kitchen & Toilet Materials Walls Miscellaneous Civil / Architectural Abbreviations HVAC Symbols HVAC Abbreviations DOC.No.EG-DO-C-001 PAGE 6 OF 109 REV.O TABLE OF CONTENTS 9.0 PRINT ROOM OPERATING PROCEDURES 9.1 Introduction 9.2 Reservation of Drawing Numbers 9.2.1 Drawing Number Reservation Form for KOC 9.3 Drawing Registration 9.3.1 Drawing Registration Form for KOC 9.3.2 Drawing Revision Form for KOC 9.3.3 Drawing Print Request Form for KOC / Contractor 9.4 Micro Filming by KOC Print Room 9.4.1 Aperture Card Preparation 9.4.2 Reduction Ratio 9.4.3. Section Filming 9.4.4 Frame Spacing 9.4.5 Center Mark, Cutting Mark & Scale 9.4.6 Positioning of Drawing a) Lens Resolution b) Exposure and Developing ¢) Film Mounting d) The Aperture Card ) Contractor Drawing Number 9.5 Revision Procedure on KOC Drawings 10.0 AS BUILT DRAWINGS 10.1 As Built Drawing Submittal 10.2 As Built Drawing Approval Stamp 10.3 As Built Drawing Sheet Sizes 10.4 As Built Drawing Title Panel 10.5 As Built Drawing Specifications DOC.No.EG-DO-C-001 PAGE 7 OF 109 REV.O 1.0 1. 1.2 13 14 21 2.2 2.3 3.1 INTRODUCTION The Engineering Drawing Practice Code (EDPC) amalgamates and updates the various requirements covered in various existing documents. The Code aims to * Bring uniformity in Mechanical, Electrical, Civil, Process and Instrumentation discipline drawings. * Provide quick reference to pre designed standard and laying down good design drawing process to work more effectively. * Assist users to read the drawings by giving fixed set of conventions in preparation of drawings. * Standardize as much possible of engineering works for projects handled by Engineering Group and Contractors. This code is for use by Kuwait Oil Company (KSC) and its Contractor, This issue of Engineering Drawing Practice Code (EDPC) supersedes the following existing KOC documents : + Engineering Drawing Office Practice Code, issued earlier. * Standards Specification for Contractor Drawings (Issue dated 25th May 1998) * The above documents are superseded and withdrawn. SCOPE This code specifies the requirements for preparation of Engineering Drawings for KOC Facilities in Kuwait. The procedure for initiation, numbering, approval and revision of drawings generated by KOC and Contractors are covered in this code. This Code also specifies the print room operating procedures. GENERAL DRAFTING PRACTICE Drawings and diagrams shall comply with the requirements of Engineering Drawing Practice Code. Presentation a) Third angle orthographic projection shall normally be used. b) Section planes shall be clearly shown. c) Elevations and sections shall be correctly orientated when viewed from the bottom or right hand edge of the drawing. DOC.No.EG-DO-C-001 PAGE 8 OF 109 REV.0 3.2 d) Isometric projections may be used for sub-assemblies of piping e) Perspective may be used to give an artists impression of the finished building or installation. f) Views and sections shall be chosen so as to present information clearly with the minimum number of views. So that information is not repeated. 9) For any equipment or detail which appears in the plan but is omitted in the section or elevation, for clarity a statement of this meaning should be added under the section name General Piping Guidelines a) All Piping will clearly indicate all Clearances, Intersections, Anchors, Guides, Piping Supports, Spring and Rod, Hangers and Connections to Associated Equipment. b) Piping Drawings will show Dimensions in mm and Levels in Metres. ¢) A Co-ordinate will locate all Equipment such as Vessels, Tanks, Exchangers, Pumps, Pipe Racks and Buildings. Piping will be Dimensioned from these Co-ordinates where possible. d) Pipe 12" and under will be drawn Single Line. Double line Piping will be used for Lines 14" and Larger. ) Each Line on the Piping Arrangement Drawings will be marked to show Flow Direction & the Line Size, Fluid Designation, Line Number, Line Class and Insulation Designation if Insulation is needed. DOC.No.EG-DO-C-001 PAGE 9 OF 109 REV.O 3.3 General Dimensioning Guidelines a) All dimensions on a drawing shall use the same unit. b) Dimensions shall normally be in millimetres, Co-ordinates, Levels and survey dimensions shall normally be in metres. If other units are required they shall be clearly stated on each drawing within brackets. c) The abbreviation symbols for Diameter, Radius and Square shall precede the figure e.g. 012 or D12, R85 and 030. d) Where equipment or material is sized in Imperial units the metric conversion shall be given in brackets, the Imperial size shall not be normally given. ) Nominal pipe sizes and valve bores should be given in Imperial units unless otherwise requested f) Fractions of millimetres shall be avoided where possible, except these are machining tolerances, sheet thickness and wire diameters, 9) Asa minus sign is easily misread, a suitable datum shall be taken as TBM (temporary bench mark) such that all levels are positive. This bench mark shall be clearly indicated on the drawing or diagram when necessary, The bench mark shall be related to the ordnance survey or chart datum. h) Normally separate drawings should be made for different types of work. For example the following should be on separate drawings Mechanical works, Civil works, Electrical works, Air conditioning, Plumbing, Fire fighting and Pipe spools which are to be prefabricated. 3.4 Colour Coding for Checking Colours used for checking shall have the following meanings: Blue - Deletions and inaccuracies Red - Additions Green - Correct Comments not implying inaccuracy like instruction to draughtsman should be marked up in pencil. All irrelevant notes, like calculations, sketching. ..etc. should't be marked up on the check print. DOC.No.EG-DO-C-001 PAGE 10 OF 109 REV.O 3.5 3.6 3.7 Dimensioning Samples 27.50 pu Drawing Scales a) The Following metric scales are preferred in laying out the drawing contents, ait 1:10 1:50 1:500 1:2500 1:40 4:2. 1:20 1:1001:10001:5000 1:33 1/3 1:5 1:25 1:200 1:2000 b) All layout and general arrangement drawings shall be drawn to scale. The scale shall be indicated in the scale section of the title block. ©) If for reason of clarity more than one scale is used, the scale used will be clearly indicated below each view or detail and the text as ‘AS SHOWN’ shall be printed in the scale section of the title d) For schematic drawings (e.g. P & ID's), the word 'NONE" shall be printed in the scale section of the title block, e) On scaled drawings where for reasons of clarity the physical dimensions are drawn "Not To Scale" the dimension shall be annotated below the dimension text thus (NTS) Graphic Scales SS GRAPHIC SCALE 1:500 a) Graphic Scales shall be placed above the Title Block. b) Graphic Scales shall be shown in all scaled drawings. DOC.No.EG-DO-C-001 PAGE 11 OF 109 REV.0 3.8 3.9 Location Plan a) Location Plan shall be placed above the Graphic scales/Title block. b) Location Plan for Plant/Facilities approaching road maps shall be indicated on the drawing wherever necessary. Key Plan a) Key Plan shall be placed above the Graphic scales/Title block b) The subject area of the particular drawing is to be hatched for clarification. 3.10 Section Indicators a& 3.11 North Arrow a) ANorth point shall appear on every plan and shall be designated True, Refinery or Plant Grid b) The North arrow shall take the form shown in option 1, 2 or 3. ‘TOP RIGHT HAND CORNER OF DRAWING SPACE 12 43 25 re PLANT TRUE /\ 6 25 \) 3 |_25__| WN) Option-1 Option-2 Option-3 3.12 Layouts, Surveys, Site and Location Plans a) The true or Grid North shall point to the top of the sheet see Option 1 & 2. b) Double arrows giving the relationship between True and Site or Plant Grid Norths shall be used on layouts and Surveys only see Option 3; for surveys, the angle of variation should be added. DOC.No.EG-DO-C-001 PAGE 12 OF 109 REV.0 3.13 3.14 3.15 3.16 Piping and Civil Drawings (Other than those for Buildings) The orientation of all piping plans and civil arrangement plans shall be the same as Plant Layout. Plans for sub-assemblies and Layout part plans must have the same orientation as the main plan layout. Architectural and Associated Plans a) On building plan the main entrance is normally shown towards the bottom of the drawing sheet. The north arrow shalll be added to the plan showing its true position. i.e. North arrow may be shown towards the bottom of the drawing sheet. b) All other plans relating to the same building should have the same orientation e.g. RC foundation, drainage, plumbing and power and lighting c) Ifa Site or Location plan is added to the same drawing sheet as the ‘working drawing’ then the Site or Location plan shall have the same orientation as the Site Layout Isometric and North Arrow The directional symbol on the pipeline isometric sheet /detail shall be shown as in Option 1 or 2 TOP RIGHT HAND CORNER OF ISOMETRIC SHEET / DETAIL Option-1 Option-2 DIAMETER OF ISOMETRIC ELLIPSE TO BE 20mm Nozzle Orientation The north arrow on vessel drawings contains designation of 0° for 90 © for "E", 180° for "S" , 270° for "W" and the orientation of a nozzle in plan is determined by this method DOC.No.EG-DO-C-001 PAGE 13 OF 109 REV.0 3.17 Orthographic Projection FUTURE TANK 11000 HIGH NEW TANK "B" 6000 HIGH 3.17.1 Plan TANK "E" TANK "D" qo I EXTENSION LL 3000 HIGH Lp a tha 1 [-—TANK "D* 3.17.2 Elevation BLOCK 'F L | T a. The full ine of Tank C is taken through the future extension of Block F and the Existing Tank E. b. Tank E is carried in front of Tank C since E is in front of C but is stopped at Block F since E is behind F. c. Tank Cis shown in a short-dash line behind Tank D but not behind both Block F and Tank D. This convention sets a limit to the extent of the hidden edges and in certain cases gives added information in the view, e.g. from the elevation alone Tank B is seen to be directly behind Block F and also behind Tank C. d. Tank A is stopped at Tank C and at the outline of Tank E since A is behind in each case. e. Edges of future or existing items that are behind other outlines should not be shown. DOC.No.EG-DO-C-001 PAGE 14 OF 109 REV.0 4.0 KOC DRAWING NUMBERING SYSTEM 4.1 General Facilities/Location/Area Codes SC] worrw area ractumies JOMTON ST soura area raciuiries _ POCATON 1 | North Kuwait Area / 217 1_| Burgan Area 050 Umm Arnish Comp 2 [Explosive Store 236 Z| Gathering Center ~ 5 3s] 3 [Gathering Center 03 403 57 Gathering Center=23 573 | | Gathering Center 04 404 4 [Gathering Genter=24 + | ~s74[ 5 | Gathering center =05 =| a5 5 | Gathering Center - 25 575 6 _| Gathering Center - 06 406 6 | Gathering Center - 26 * 576 7_| Gathering Center - 07 407 7_| Gathering Center - 190 (Water) 617 8 _| Gathering Center - 08 408 8 | Booster Station - 130 591 9_| Gathering Center - 12 412 5 [Booster Station= 131 $93. 10 | Gathering Center= 13 413 10 [Genial econ Pring Faces (HPF)| 626 | 11. | Gathering Center14» | 14 Ti [Sea Wier Tretment Pare SWF) | 217 | 12 | Gathering Center 27 356 15 | Booster Station 140 582 1 [Booster station = 150 382 i [Wat io3 16 | Gas Injection Plant 332 Sc] easrarearaciumies JOMION ST west anearacturries _ fOCATON [aimed es O51_|-1 | West Kiwait rea 730 2 | Gathering Center 07 40i| 2 [ Abduliya & Saka Water Station [049 5" Gathering Genter 02 402-3 | Gathering Center “16 516 4 [athering Genter 08 4094 | Gathering Center=17 518 5__| Gathering Center - 10 410 5 | Gathering Center - 18 * 519 6 _| Gathering Center - 11 411 6 _| Gathering Center - 27 577 7_| Gathering Center - 19 555 7_| Gathering Center - 28 578 8 _| Gathering Center - 20 555 8 | Booster Station - 170 620 9_| Gathering Center - 22 557 9 _| Minagish Water Injection Plant 217 0" Chiled Water Piant-A 7 psc rere 11_| Chilled Water Plant - B 178 No. GENERAL CODE [Mina & Marine 350_|-1 | Common fora GCs O70 15 [North Tank Farm 270] >| Standard 015 1 [South Tank Farm 279-3 [Wel Read mG 15 [North Fer 12k [4 [Cathodic ProFeCON 35 16 [South Per 128 [5 [Ges tne 418 17_| Ahmadi Hospital 098 6 _| Pipe Line Services 615 18 | Industrial Area 031 7_| Crude Oil Transit Line 105 15 [ Shuaiba area 5688 [Sub Staton 097 20" KPc Building 301 | 9 [Police Head Quarter 662 3 | A-Tameer Buiaing 650] 10" Rosa 2 1 [Traq Kawai Gas Une 62 i | Water Line 106 NOTES: + GATHERING CENTER'S 5,12,13,14,18,24 & 26 ARE ABANDONED. DOC.No.EG-DO-C-001 PAGE 15 OF 109 REV.0 LOCATION CODE SERIAL NO./SEQUENTIAL NO. “TL _[ (SEQ 000-00-000 | _piscrpuine cove DISCIPLINE DRAWING ‘CODE TYPE DESCRIPTION on General Layout | Plot Plan, Data Sheets, Charts, Specification 2 civil Building, Foundation, Car Park, Roads, Fences, Architectural, Doors, Windows 03 Structure | Steel Works, Concrete, Masonry, Carpentry, Cellings, Roof 04 Piping _| All Type of Piping os Mechanical & | Equipment, Rotating Equipment, Compressors, Pumps, Drivers, Process _| Blowers, Blenders, Mixers, P & ID's, Flow Diagrams, HVAC 06 Tank & Vessels | Pressure Vessels, Columns, Storage Tanks o Electrical | Telecom, Earthings, Cathodic Protections, Motors, Generators, Transformers, Converters os instrumentation] Control Valves, Indicators, Instrument Panels, Alarms, Measuring Equipment, Pneumatic Tubing 4.2 P&ID Numbering System 407-5-316 FACILITY/AREA CODE 7 DISCIPLINE CODE SEQUENTIAL NUMBER 4.3. Equipment Numbering System 25-G-101A PLANT NUMBER EQUIPMENT IDENTIFICATION PREFIX TRAIN=1,2,3, ETC. (COMMON=0) SEQUENTIAL NO. PARALLEL/STANDBY/SPARE UNITS(A,B,C,ETC.) 4.4 Line Numbering System 16"-PL-1090-C15A-HC LINE SIZE FLUID DESIGNATION LINE NUMBER LINE CLASS (REFER PIPING MATERIAL SPEC.) INSULATION DESIGNATION DOC.No.EG-DO-C-001 PAGE 16 OF 109 REV.0 5.0 DRAWING FRAMES & TITLE BLOCK 5.1 Specimen of Drawing Frames & Title Block Er ALL 210 AO 15 841 G ARROW fim] S| a 1189 ALL 210 es a 15, Al+ 686 970 ALL 210, | A3 al = 420 210 210 Al al 594 i 15 ime] * 841 {| Bf 594 DOC.No.EG-DO-C-001 PAGE 17 OF 109 REV.O 5.2 Drawing Title Panel (KOC: All KOC drawing shall have the standardized drawings title panel as shown. KUWAIT OIL CO. epg SI Da ES 2 K. S.C. core ‘AREA / LOCATION PROWECT TITLE PROJECT TITLE DRAWING TITLE DRAUGHT DESON APPROVALS ome [Brn vane am | wane Seunne | oeseunon | oe [eeena/wn| ae [sna cae fercra.none| save [seonse| cae SCALES Peawne [SHEET No. | REV. 5.3. Folding of Drawings AO 841 x 1189 33" x 47" AL + 686 x 970 27" x 38" AL 594 x 841 23" x 33" AQ 420 x 594 t 16.5" x 23" ! i AB 297 x 420 11.7" x 16.5" Ad 210 x 297 8.3" x 11,7" DOC.No.EG-DO-C-001 PAGE 18 OF 109 REV.0 6.0 CAD LAYER SPEC! 6.1 Piping and Instrumentation ;ATIONS DESCRIPTION CAD LAYER | COLOUR No.| COLOUR NAME | _LINE TYPE PIPELINE PIPE 7 BLACK EQUIPMENT EQ 7 BLACK FITTINGS FIT 6 MAGENTA TEXT TXT 3 GREEN INSTRUMENT/PLANT AIR TA/UTA 11s 115 MISCELLANEOUS MISC 21 21 INST.CABLE INST 234 234 PNEUMATIC SIGNAL PNEW rm 1 PPB FENCE FENCE 1 RED eo DATA AND CONTROL CABLE pec 1 RED a HYDRAULIC SIGNAL HS 40 40 — CAPILLARY TUBING cr 4 CYAN So ELECTRICAL SIGNAL ES 1 RED BCS SOFTWARE OR oes 5 aue | —o—o— TELEMETRY SIGNAL Ts 3 GREEN -~<>-- GRIDS GRID 8 GRAY VIEW PORTS vp 7 BLACK MATCHLINE ML 7 BLACK — 6.2 Piping DESCRIPTION CAD LAYER | COLOUR No.| COLOUR NAME | LINE TYPE EQUIPMENT EQ 7 BLACK CRUDE OIL WET cRW 14 14 CRUDE OIL DRY CRD 44 44 LP GAS LP 40 40 HP GAS HP 40 40 FUEL GAS FUEL 40 40 LEAN GAS LEAN 40 40 CONDENSATE COND 30 30 DOC.No.EG-DO-C-001 PAGE 19 OF 109 REV.0 6.2 Piping (Cont'd) DESCRIPTION CAD LAYER | COLOUR No.| COLOUR NAME | LINE TYPE CHEMICAL/GLYCOL CHEM/GLY 3 GREEN FRESH WATER FRW 5 BLUE BRACKISH WATER BRW 4 CYAN FIRE FIGHTING WATER FFW 1 RED DRAINAGE/BLOW DOWN DRN 6 MAGENTA DIMENSIONS DIM 7 BLACK TEXT Tx 3 GREEN MISCELLANEOUS MISC 21 21 —_— — LINE 100/ RELIEF LINE L100 13 13 LINE 80 L80 210 210 FLARE / FLARE LINE FL 31 31 — — NITROGEN N2 46 46 DIESEL DSL 200 200 INSTRUMENT/PLANT AIR TA/UTA 115 115 FLOW LINE FLOW LINE 3 GREEN FENCE FENCE 1 RED See el BUND WALL Bw 1 RED a ASPHALT ROAD ASR 5 BLUE ——— RIG ROAD RGR 5 swe | -—-——— TRACK ROAD TR 5 awe | -———— OIL WELL ow 7 WHITE + WATER WELL ww 6 MAGENTA + CABLE MARKER cM 7 WHITE . FIRE HYDRANT FH 1 RED e CRASH BARRIER cB 1 RED e GRIDS GRID 8 GRAY OIL LAKE OL 1 RED OIL FIELD OF 8 GRAY VIEW PORTS ve 7 BLACK MATCHLINE ML 7 BLACK DOC.No.EG-DO-C-001 PAGE 20 OF 109 REV.O 6.3 Electrical POWER CABLE CABLE 1 RED BAe COMER EnTINGTAPE | _—EBaRE | __74 74 PVC SHEATHED EARTHING CABLE] ECAB 74 74 BUSBAR BUSBAR 3 GREEN EQUIPMENT ea 7 BLACK TELEPHONE CABLE Tee 208 24 | CATHODIE PROTECTION car 124 124 ELECTRIC OVERHEAD CABLE] EOC 1 neo | GROUND BED 5 1 = 3 SRANSFORMER Recrifier | TCPR 5 uve SUBSTATION 3 &_|_wacenTa TRANSFORNER Tease | 6 (| MAGENTA OVER HEAD LINE POLE / PYLON 4 CYAN © MISCELLANEOUS wise 2 2 VIEW PORTS VP. 7 BLACK 6.4 Civil/Architectural DESCRIPTION CADLAVER [COLOUR No] COLOUR NAME | LINE TPE concaere cone 1 = EXTERNAL WALL X-WALL 1 GREEN TORET S BATH = &__| MAGENTA aa eee crix & | _Nacenra WINDOW WIN 5 BLUE STRUCTURAL BARS S-BAR 8 8 ANGLE BARS (bans 3 GREEN DOC.No.EG-DO-C-001 PAGE 21 OF 109 REV.O 6.4 Civil/Architectural (Cont'd) =e a a CRASH BARRIER cB 1 RED e vores a Sma ROAD we ee ESSE — wee ene es . toe 6.5 Heating Ventilation & Air Conditioning DESCRIPTION CAD LAYER | COLOUR No.| COLOUR NAME | LINE TYPE HVAC EQUIPMENT H-EQ 5 BLUE SUPPLY AIR DUCT SUPPLY 6 MAGENTA, RETURN AIR DUCT RETURN 30 30 SUPPLY AIR DIFFUSERS S-DIFFUSER 1 RED RETURN AIR DIFFUSERS R-DIFFUSER 4 CYAN HVAC REFRIGERANT PIPE H-PIPE 8 GRAY HVAC DATA H-DATA 3 GREEN HVAC UNIT H-UNIT 14 14 HVAC TEXT HOTXT 3 GREEN WALL HAWALL 7 BLACK VIEW PORTS ve 7 BLACK MISCELLANEOUS. MISC 21 24 = MATCHLINE ML 7 BLACK DOC.No.EG-DO-C-001 PAGE 22 OF 109 REV.O 7.0 LINE CHARACTERISTICS 7.1 Piping Drawing DESCRIPTION WITT [une vee SYMBOL corer ne el EXISTING PIPING ABOVE GROUND DEFAULT | CONTINUOUS: SERRA SMP [cena fon | —— — — FUTURE PIPING DEFAULT | CENTER 2 FUTURE OUTLINE OF FUTURE FACILITIES DEFAULT | CENTER 2 FUTURE 7.2. Piping and Instrument Diagrams, Process Flow Diagrams & Signal Lines DESCRIPTION WTR [une nee SYMBOL NEW PROCESS LINE 0.40 | CONTINUOUS EXISTING LINE DEFAULT | CONTINUOUS AUXILIARY LINE (MINOR PROCESS/UTILITY) | DEFAULT ™| PHANTOM 2 | —— — — — FUTURE LINE DEFAULT | CONTINUOUS | —»—»—»—»—s BATTERY LIMIT 0.70 | PHANTOM? | —— — — — LIMIT OF VENDOR SCOPE OF SUPPLY peraut | centerR2 | —— — —— INSTRUMENT AIR (PNEUMATIC SIGNAL) DEFAULT * | CONTINUOUS A INSTRUMENT LIQUID (HYDRAULIC SIGNAL) | DEFAULT * | CONTINUOUS | 4. —_.— ELECTRICAL SIGNAL DEFAULT *| HIDDEN — ELECTRO MAGNETIC OR SONIC DEFAULT *| CONTINUOUS |) 2a — INSTRUMENT CAPILLARY TUBING perautt *| CONTINUOUS | —%——x——x NOTE: * FOR NEW WORK LINE WIDTH SHALL BE 0.30 mm DOC.No.EG-DO-C-001 PAGE 23 OF 109 REV.O 8.0 SYMBOLS & ABBREVIATIONS 8.1 Piping and Instrument Diagram (P & ID) Symbols 8.1.1 Equipment Identification Prefixes A AGITATOR/MIXER, L FILTERS/COALESCERS c COLUMNS, SEPARATORS, DRYERS. N INSULATION >| Tanks P| ELECTRICAL EQUIPMENT E_|_HEAT TRANSFER EQUIPMENT Rr | BUILDINGS EP EVAPORATION POND SCRAPER LAUNCHER/RECEIVER F FIRED HEATERS, FLARE STACKS, BURN PIT sp ‘SPECIALTY ITEM PUMPS (DRIVERS:GM=MOTOR, © GT TURBINE, GE=ENGINE) su SUMP H VACUUM EQUIPMENT MATERIAL HANDLING EQUIPMENT HP | HOLDING POND VESSEL/DRUM INSTRUMENT AND COMMUNICATION >| ouement w | WASTE WATER TREATMENT UNITS COMPRESSORS, BLOWERS, FANS | (DRIVERS: KM=MOTOR, KT=TURBINE, KE=ENGINE)| 7 PACKAGES 8.1.2 Fluid Designation AA | AERATION AIR FG | FUEL GAS, PILOT Gas at_| INSTRUMENT AIR GH | RICH GLYCOL ap | PLANT AIR GI_| _ INERT GAS (NITROGEN) 8D | BLOWDOWN AND RELIEF GN | NATURAL GAS crD | CRUDE DRY cp | PURGE GAS crw | CRUDE WET cy | LEAN GLYCOL ‘cw | CONTAMINATED WATER IN. | INJECTION CHEMICAL DC | CHEMICAL DRAIN KP | PROCESS CHEMICAL DD | DEDICATED DRAIN oF | FUEL OIL (DIESEL) DH OILY DRAIN (OPEN) OH HYDRAULIC OIL DO | OPEN DRAIN (WATER) OL | LUBE OIL AND SEAL OIL, DP. PRESSURIZED DRAIN PC PROCESS CONDENSATE DR | STORM DRAIN Pe | PROCESS EFFLUENT ss SANITARY SEWER PG PROCESS GAS/VAPOUR EG EXPORT GAS PL PROCESS LIQUID ES | ELECTRIC POWER SUPPLY RF | REFRIGERANT Fe | FIRE FOAM va | VENT To ATMOSPHERE DOC.No.EG-DO-C-001 PAGE 24 OF 109 REV.0 8.1.2 Fluid Designation (Cont'd) vt | VESSEL TRIM XC | CORROSION INHIBITOR we | COOLING WATER SUPPLY xD | ANTI-FOAM WF FIRE WATER XE | DEMULSIFIER wo | POTABLE WATER xF__| COAGULANT wo | _OILy WATER xG_| FOAM we PRODUCED WATER/FORMATION WATER | XH | OXYGEN SCAVENGER wr | COOLING WATER RETURN xI ACID ws SEA WATER xd CAUSTIC wr TREATED WATER XK | SOLVENT wu | UTILITY WATER xt | BIOCIDE ww | WELL WATER (BRACKISH) xM__| HYPO CHLORITE XA METHANOL XN | POLYELECTROLITE XB SCALE INHIBITOR vr | VAPOR 8.1.3 Insulation Designation (For Piping/Equipment) ACOUSTIC FA FIREPROOF & ACOUSTIC COLD Ha | HOT ACOUSTIC cA COLD ACOUSTIC Hc | HEAT CONSERVATION csa | COLD & SPECIAL ACOUSTIC HSA | HOT & SPECIAL ACOUSTIC eT ELECTRICAL TRACING PP. PERSONNEL PROTECTION ETA | HEAT & ACOUSTIC W/ELECTL TRACING | SA | SPECIAL ACOUSTIC 8.1.4 Line Continuations P&ID NO. PKK HOS > LINE ENTERING/LEAVING P&ID. FLUID DESIGNATION/DESTINATION/ORIGIN (NOTE 1) > 2-WAY FLOW xx XX-FLUID DESIGNATION (APPLICABLE TO DRAIN, RELIEF, VENT, P&ID NO. VENT, BLOWDOWN AND OTHER UTILITIES WHERE SEPARATE Pato No DISTRIBUTION P&ID PLANNED FOR) ! NOTE: 1 SHOW FLUID NAME AND ITEM NO, OF DESTINATION OR ORIGIN. EXAMPLE: HP DRY CRUDE TO HP SEPARATOR 407-C-001 DOC.No.EG-DO-C-001 PAGE 25 OF 109 REV.O 8.1.5 Instrument Tag Number Identification / Instrument Identification INSTRUMENTS ARE IDENTIFIED FOR LEVEL, FLOW, PRESSURE AND TEMPERATURE ETC. AS FOLLOWS: (EXAMPLE FOR LEVEL) LSHH-1111A LSHH LEVEL SWITCH HIGH HIGH USH LEVEL SWITCH HIGH INSTRUMENT IDENTIFICATION LT LEVEL TRANSMITTER LC LEVEL CONTROLLER TRAIN=1,2,3, ETC. (COMMON=0) u LEVEL INDICATOR LG LEVEL GAUGE SEQUENTIAL NUMBER USL LEVEL SWITCH Low ‘SUFFIX (OPTIONAL) USLL LEVEL SWITCH Low Low LAHH LEVEL ALARM HIGH HIGH (TYPICAL) 8.1.6 Instrument Line Symbols A A AF - PNEUMATIC SIGNAL tt HYDRAULIC SIGNAL, oO CAPILLARY TUBING ELECTRICAL —o—o— DCS SOFTWARE OR FIRMWARE LINK —- === TELEMETRY SIGNAL oa ELECTROMAGNETIC/SONIC SIGNAL 8.1.7 Instrument Symbols (Local) LOCALLY MOUNTED INSTRUMENT INSTRUMENTS SHARING COMMON HOUSING LOCALLY MOUNTED INSTRUMENT (FUTURE) LOCALLY MOUNTED INSTRUMENT (EXISTING) LOCALLY MOUNTED FOUNDATION FILEDBUS, COMPLIANT INSTRUMENT LOCALLY MOUNTED PROFIBUS DP COMPLIANT INSTRUMENT, DOC.No.EG-DO-C-001 PAGE 26 OF 109 REV.0 8.1.8 Local/Local Panel/Packaged Unit Panel OQ PILOT LIGHT LOCAL PLE PROGRAMMABLE LOGIC OR SEQUENCE CONTROL FIELD MOUNTED PROGRAMMABLE LOGIC OR SEQUENCE CONTROL ACCESSIBLE TO OPERATOR AT AUXILIARY LOCATION PANEL OR SYSTEM INST. IN AUXILIARY ROOM OR CONTROL ROOM OW REAR OF PANEL OR BLIND INSTRUMENT SYSTEM IN AUXILIARY ROOM OR CONTROL ROOM PILOT LIGHT PANEL MOUNTED q INSTRUMENT LOCATED IN LOCAL GAUGE BOARD PILOT LIGHT LOCAL PANEL MOUNTED INSTRUMENT LOCATED ON LOCAL PANEL ONE OR TWO DIGIT NUMBER SHALL BE USED TO IDENTIFY SPECIFIED LOCAL PANEL p|p INSTRUMENT LOCATED REAR OF LOCAL PANEL ONE OR TWO DIGIT NUMBER SHALL BE USED TO IDENTIFY SPECIFIED LOCAL PANEL 8.1.9 Distributed Control System DCS VDU DISPLAYED INSTRUMENT IN CENTRAL CONTROL ROOM oR DCS VDU DISPLAYED INSTRUMENT IN CENTRAL CONTROL ROOM TREND OR SEQUENCE RECORDER FIRST CHARACTER DEFINED BY LOOP TYPE DCS VDU DISPLAYED SOFTWARE ALARM DCS VDU DISPLAYED INPUT ALARM HARD WIRED OR SERIAL LINK DCS LOGIC NORMALLY ACCESSIBLE TO OPERATOR (XXX LOGIC DIAGRAM SHEET NUMBER) DCS LOGIC NOT NORMALLY ACCESSIBLE TO OPERATOR (XXX LOGIC DIAGRAM SHEET NUMBER) DOC.No.EG-DO-C-001 PAGE 27 OF 109 REV.0 8.1.10 Programmable Logic Controllers pic PROGRAMMABLE LOGIC OR SEQUENCE CONTROL ACCESSIBLE t TO OPERATOR (YYY PLC NUMBER) w (XX LOGIC DIAGRAM SHEET NUMBER) Pica PROGRAMMABLE LOGIC OR SEQUENCE CONTROL NOT ACCESSIBLE TO OPERATOR (YYY PLC NUMBER) (XXX LOGIC DIAGRAM SHEET NUMBER) ESD NORMALLY ACCESSIBLE TO OPERATOR (Y SHUTDOWN LEVEL) V7 vex (Xxx ESD LOGIC DIAGRAM SHEET NUMBER) a ESD NOT NORMALLY ACCESSIBLE TO OPERATOR Y|Xxx. (Y SHUTDOWN LEVEL) (XXX ESD LOGIC DIAGRAM SHEET NUMBER) -_- INPUT TO SHUTDOWN SYSTEM WITH S/D LEVEL (Y) —_—o OUTPUT FROM SHUTDOWN SYSTEM WITH S/D LEVEL (Y) 8.1.11 SCADA System REMOTE TERMINAL UNIT(SCADA) 8.1.12 Miscellaneous XJAIMAEIMEA FUNCTION INSTRUMENT RELAY SQUARE ROOT ADD OR TOTALISE SUBTRACT BIAS HIGH SELECT LOW SELECT MULTIPLY DIVIDE INTEGRAL FUNCTION SET POINT LIMITS OTHER FUNCTIONS AS PER 1.5.A. ‘TRANSDUCER (I/P, E/P, E/I, P/I) RATIO PROPORTION FUNCTION DOC.No.EG-DO-C-001 PAGE 28 OF 109 REV.O 8.1.12 Miscellaneous (Cont'd) OR GATE AND GATE Oe INTERLOCK GATE (ARROW DENOTES DIRECTION OF LOGIC) 3 WAY PNEUMATIC HAND SWITCH IS 4 WAY PNEUMATIC HAND SWITCH 8.1.13 Level Instruments i LEVEL SWITCH LEVEL TRANSMITTER EXTERNAL FLOAT TYPE (TRANSMITTERS/CONTROLLERS/GAUGE GLASSES) uw DIFFERENTIAL TYPE LEVEL INDICATING TRANSMITTER, afaliia|a INTERNAL FLOAT TYPE LEVEL INSTRUMENT A ié GB LEVEL GLASS (ILLUMINATED) 8.1.14 Temperature In: struments. Te XXX-RTD, T.C.(TYPE K) ETC. 8.1.15 Pressure Instruments PRESSURE INDICATING TRANSMITTER alta CHEMICAL/DIAPHRAGM SEAL DOC.No.EG-DO-C-001 PAGE 29 OF 109 REV.O 8.1.16 Flow Instruments FLOW TRANSMITTER (ORIFICE PLATE) SENIOR ORIFICE FITTING FLOW TRANSMITTER (VENTURI, DALL OR FLOW NOZZLE) + RESTRICTION ORIFICE oF “IN LINE" TYPE FLOW METERS (TARGET - TGT) (MAGNETIC FLOW -MAG) (CORIOLIS - COR) (THERMAL MASS FLOW -TMF) (ULTRASONIC FLOW - ULT) (VORTEX FLOW - VOR) POSITIVE DISPLACEMENT INDICATING METER WITH INTEGRATOR TURBINE METER © VARIABLE AREA METER (ROTAMETER) te Ot RO © FQL © © ©; FLOW TRANSMITTER (PITOT TUBE/ANNUBAR) VORTEX FLOW TRANSMITTER, FLOW STRAIGHTENING VANES DOC.No.EG-DO-C-001 PAGE 30 OF 109 REV.0 8.1.17 Miscellaneous Symbols for P&ID SPEC. BREAK/LINE NUMBER BREAK FLANGES == _| CHaticeinsucation Limit AG_,_UG_ | ABOVEGROUND/UNDER |_| tino tance feotreo) j-US_ | ABOVESROUNDIUNDER 7 —_ | INSULATION AND | INSULATING FLANGE f ELECTRICAL TRACING 3 — J insutarion —-H-—_| Removaste soot ee (e.g. PERSONNEL PROTECTION) SPECTACLE BLIND 4 BARRED TEE _f (CLOSED) ———1 | weww cap SPECTACLE BLIND (OPEN) —}-— HAMMER/PADDLE SCREW CAP FL | ganissarraote ——1 | rue ——_jL__ | rine spacer erxa" ——— | concentric repucer ty _| verve STRAINER era" Y-TYPE STRAINER WITH i | eccentric reoucer S 1/2" VALVE NORMALLY nc CLOSED AND PLUGGED. LINE JOINED WITH = ee — =} | rrvee strainer uw SILENCER ———_ | FEMALE HOSE CONNECTION FLAME ARRESTOR MALE HOSE CONNECTION WITH CAP INSTRUMENT FILTE ER 2% LINE (2% SLOPE MINIMUM) SIGHT GLASS EXPANSION BELLOWS ro FLEXIBLE HOSE , IN LINE FILTER — TUNDISH WITH SAND Ye quNol T TRAP VB VORTEX BREAKER. C ATMOSPHERIC VENT DEMISTER PAD/WIRE ATMOSPHERIC VENT CY MESH SCREEN ~ WITH MESH SCREEN DOC.No.EG-DO-C-001 PAGE 31 OF 109 REV.0 8.1.17 Miscellaneous Symbols for P&ID (Cont'd) TIE-IN NUMBER (0X TIE-IN NUMBER) (YYY PLANT NUMBER) VENDOR TIE-IN POINT PULSATION DAMPER DUPLEX STRAINER CONE TYPE T-TYPE STRAINER (TEMP.) STRAINER (TEMP.) >| he] <>] | BREATHER CAP ANALYZER 49] |i BLOWER INLET SILENCER | —————— | _ NEW PROCESS LINE BLOWER INLET ‘AUXILIARY LINE FILTER SILENCER — (UTILITY) Za STATIC MIXER, —_ EXISTING LINE DISTRIBUTOR/SPRAY ano 39 NOZZLE FUTURE LINE BATTERY LIMIT EXHAUST HEAD _ ___ | LIMIT OF veNDors scope SPECIAL PIPING ITEM (XXX ITEM NUMBER) OF SUPPLY UTILITY STATION WiAIN W-WATER, A-AIR, Gc) SAMPLE CONNECTION N-NITROGEN DF-DRINKING FOUNTAIN, DA SS-SAFETY SHOWER VESSEL INSULATOR EW-EYE WASH YY TUNDISH DOC.No.EG-DO-C-001 PAGE 32 OF 109 REV.0 8.1.18 Valves for Piping and Instrument Diagram GATE VALVE Ded GLOBE VALVE CHECK VALVE Pro. BUTTERFLY VALVE BALL VALVE PLUG VALVE NEEDLE VALVE DIAPHRAGM VALVE ANGLE VALVE 3-WAY VALVE FLOAT OPERATED VALVE 4-WAY VALVE CHOKE VALVE EQUALISING VALVE ON MAIN BODY Bes} & | 707) ¥¢/o] zx RECIRCULATION VALVE DRAIN VALVE ON MAIN BODY rok [AX |e OX|X) |S 8.1.19 Equipment a) Vessels VERTICAL VESSEL (WITH DEMISTER) ( HORIZONTAL VESSEL HORIZONTAL VESSEL (WITH BOOT) =| SCRAPER LAUNCHER/RECEIVER TRAY TOWER PACKED COLUMN b) Filters FILTER(CARTRIDGE) COALESCING FILTER (CARTRIDGE) REV.0 PAGE 33 OF 109 DOC.No.EG-DO-C-001 c) Tanks OPEN TANK FLOATING ROOF TANK CONE ROOF TANK oo) DOME ROOF TANK RECTANGULAR TANK CYLINDRICAL TANK d) Heat Exchangers iS 4 Ht &) 8 bl | & SHELL & TUBE EXCHANGER, GENERAL DOUBLE PIPE PLATE HEAT EXCHANGER(PFD) EXCHANGER EXCHANGER, Cs | 2 KETTLE TYPE ELECTRIC AIR COOLER AIR COOLER EXCHANGER HEATER (INDUCED DRAFT) (FORCED DRAFT) PeeeeeeeeeD ——" HEATER AIR COOLER HEATER (WITH AUTOMATIC LOUVERS) (DIRECT FIRED) (INDIRECT FIRED) e) Pumps rot CENTRIFUGAL PUMP RECIPROCATING PUMP SUBMERSIBLE PUMP (MOTOR DRIVEN) (MOTOR DRIVEN) (MOTOR DRIVEN) a oe He +H he INUNE CENTRIFUGAL INLINE CENTRIFUGAL BARREL PUMP PUMP (MOTOR DRIVEN) PUMP (TURBINE DRIVEN) (AIR DRIVEN) DOC.No.EG-DO-C-001 PAGE 34 OF 109 REV.0 e) Pumps (Cont'd) —R {9 t mp n™ LIQUID RING, SLIDING VANE VACUUM PUMP GEAR PUMP ROTARY SCREW PUMP (MOTOR DRIVEN) (MOTOR DRIVEN) (MOTOR DRIVEN) cl i ee a 1H H ¢ VERTICAL PUMP CANNED PUMP SUMP PUMP METERING PUMP (MOTOR DRIVEN) (MOTOR DRIVEN) (MOTOR DRIVEN) (MOTOR DRIVEN) f) Mixing Devices ™ ct L “ CHEMICAL LOADING PUMP MIXER/AGITATOR (AIR DRIVEN) g) Compressors/Blowers/Fans/Ejectors CENTRIFUGAL BLOWER/FAN (MOTOR DRIVEN) CENTRIFUGAL LL compressor wins -G- _wecrorveoucton GEAR AND TURBINE) CENTRIFUGAL RECIPROCATING COMPRESSOR 4 + 4 { COMPRESSOR (WITH INTERSTAGE (4H = (MOTOR DRIVEN WITH cooLiNe) INTERSTAGE COOLING) 4 { SCREW i COMPRESSOR (MOTOR DRIVEN) h) Drivers i] ELECTRIC MOTOR SE] __ DIESEL ENGINE A] PNEUMATIC MOTOR TURBINE GAS ENGINE DOC.No.EG-DO-C-001 PAGE 35 OF 109 REV.0 j) P & ID Abbreviations * SUPPLIED BY VENDOR ew EYE WASH aC AIR TO CLOSE FB FULL BORE AF AIR FAIL FC FAIL CLOSE AG ABOVE GROUND FF FLAT FACE a0 AIR TO OPEN Fac | FIRE & GAS SAFETY SYSTEM ov | AIR OPERATED VALVE FO FAIL OPEN Apc | AUTOMATIC PUMP START FL FAIL LOCKED IN POSITION arm | ATMOSPHERE FLG FLANGE BDV BLOWDOWN VALVE GB LOCAL GAUGE BOARD: BS&W BASIC SEDIMENT AND WATER GO GEAR OPERATED cA CORROSION ALLOWANCE Gov GAS OPERATED VALVE cc CORROSION COUPON HH HAND HOLE cLD CLOSED DRAIN HOA HAND-OFF-AUTOMATIC co CLEAN OUT 1D INSIDE DIAMETER csc | CAR SEAL CLoseD KP KILOMETER POST cso | CAR SEAL OPEN uc LOCKED CLOSED Dcs_ | DISTRIBUTED CONTROL SYSTEM uep LOCAL CONTROL PANEL DIAG | DIAGRAM Lo LOCKED OPEN DP DESIGN PRESSURE max | MAXIMUM oT DESIGN TEMPERATURE MIN | MINIMUM pwe | DRAWING MoS | MAINTAINED OVERRIDE SWITCH EIN EQUIPMENT IDENTIFICATION NUMBER} MOV | MOTOR OPERATED VALVE gL ELEVATION Mw MANWAY ESD | EMERGENCY SHUTDOWN Mc MANUAL CONTROL espv | EMERGENCY SHUTDOWN VALVE Mcc | MOTOR CONTROL CENTER DOC.No.EG-DO-C-001 PAGE 36 OF 109 REV.O j) P & ID Abbreviations (Cont'd) NB | NOMINAL BORE so | STEAM OUT Nc | NORMALLY CLOSED sp | SET POINT NLL NORMAL LIQUID LEVEL SSLS | SEQUENCING AND SHUTDOWN LOGIC SYSTEM] NNF NORMALLY NO FLOW S/S | VESSEL SEAM TO SEAM nts | NOT TO SCALE sTD | STANDARD oD OUTSIDE DIAMETER TC TEST CONNECTION op | OPERATING PRESSURE TDS | TOTAL DISSOLVED SOLIDS OT | OPERATING TEMPERATURE TEMP) TEMPORARY PDLC | PAD-LOCKED CLOSED THK | THICKNESS PDLO | PAD-LOCKED OPEN TMR | TRIPLE MODULAR REDUNDANT PFD PROCESS FLOW DIAGRAM TSO | TIGHT SHUT-OFF PLC | PROGRAMMABLE LOGIC CONTROLLER | TSS | TOTAL SUSPENDED SOLIDS PO PUMPOUT T/T VESSEL TANGENT TO TANGENT pro) | PROJECT TYP. | TYPICAL Rev | REMOTE BLOCK VALVE uc | UTILITY CONNECTION RF | RAISED FACE us | UNDERGROUND RO | RESTRICTION ORIFICE US | UTILITY STATION ROV | REMOTE OPERATED VALVE vac | VACUUM SBDV | SAFETY BLOWDOWN VALVE VB | VORTEX BREAKER sc | SAMPLE CONNECTION vr | VESSEL TRIM spv | SHUTDOWN VALVE wo | WASH ouT syo | sHuTDOwN wT | WALL THICKNESS sHT | SHEET BF | BLIND FLANGE sc | SPECIFIC GRAVITY AS | AIR SUPPLY SN ‘SITE NUMBER RTRP| REINFORCED THERMOSETTING RESIN PLASTIC vou | VISUAL DISPLAY UNIT SCADA) SUPERVISORY CONTROL & DATA ACCUSATION| DOC.No.EG-DO-C-001 PAGE 37 OF 109 REV.0 k) Instrument Identification Letters FIRST LETTER SUCCEEDING LETTERS MEASURED OR DISPLAY ouTuT initiating variasle | MOPIFIER | euncrion FUNCTION MODIFIER a | anavysis ALARM 8 | BURNER, FLAME couron [USER'S CHOIce __|USER'S CHOICE cc | Conoucriviry (ELECTRICAL) CONTROL p | DENSITY OR DIFFERENTIAL SPECIFIC GRAVITY PRIMARY = | VOLTAGE (EMF) PRIMARY F | FLow RATIO (FRACTION) G | GAUGING IGAUGE GLASS H. | HAND (MANUALLY INITIATED)] HAND HIGH, OPEN 1 | CURRENT (ELECTRICAL) linpicaTe 3 | POWER SCAN TIME RATE OR k | TIME OR TIME SCHEDULE] IE RATE CONTROL STN. uf uever LIGHT (PILOT) Low, CLoseo ™_| MOISTURE MONITORING N | CORROSION luser's choice [USER'S CHOICE _ [USER'S CHOICE , ORIFICE ° USER'S CHOICE (RESTRICTION) P | PRESSURE OR VACUUM POINT (TEST CONNECTION) INTEGRATE [INTEGRATE @ | QUANTITY OR EVENT — lop ToTaLize [oR TOTALIZE RECORD T R | RADIATION RECORD” | SPEED OR FREQUENCY [SAFETY system —_|SwITcH SELECTOR 7 | TEMPERATURE TRANSMIT u_| MULTI VARIABLE MULTI FUNCTION) MULTI FUNCTION MULTI FUNCTION y | visration VALVE, DAMPER MECHANICAL ANALYSIS OR LOUVER w | WEIGHT OR FORCE WELL x | SPECIAL VARIABLE X AXIS lUNcLASSIFIED| UNCLASSIFIED —_|UNCLASSIFIED| Y_[ USER'S CHOICE Y AXIS RELAY OR COMPUTE| DRIVER, ACTUATOR OR z | POSITION DIMENSION |Z AXIS. UNCLASSIFIED ContROu DOC.No.EG-DO-C-001 PAGE 38 OF 109 REV.0 8.1.20 Instrument Valves for P & ID ae HAND CONTROL VALVE MOTOR OPERATED VALVE (BALL) LOCALLY OPERATED OK CONTROL VALVE WITH DIAPHRAGM ACTUATOR. FAILURE MODE (FO, FC, FL) PISTON ACTUATED VALVE (AIR/GAS OPERATED) 2-WAY SOLENOID VALVE CONTROL VALVE WITH HAND DIAPHRAGM ACTUATOR FC 2-WAY SOLENOID VALVE (ENERGISE TO OPEN) ve] CONTROL VALVE WITH DIAPHRAGM ACTUATOR AND ATTACHED SIGNAL CONVERTER. 2-WAY SOLENOID VALVE WITH MANUAL RESET SELF CONTAINED PRESSURE REDUCING REGULATOR WITH HANDWHEEL, ADJUSTABLE SET POINT TIME DELAY XX SECONDS 2-WAY SOLENOID WITH TIME DELAY TRIP & MANUAL RESET PRESSURE-REDUCING REGULATOR WITH EXTERNAL PRESSURE TAP 3-WAY SOLENOID VALVE CONTROL VALVE WITH HAND WHEEL DIAPHRAGM ACTUATOR WITH POSITIONER & SOLENOID VALVE) ON S/D DUTY (CONTROL SIGNAL INPUT) ANY VALVE, FAIL LOCKED (POSITION DOES NOT CHANGE) DIAPHRAGM ACTUATOR WITH POSITIONER (CONTROL SIGNAL INPUT) 7) ANY VALVE, FAIL, INDETERMINATE DOC.No.EG-DO-C-001 PAGE 39 OF 109 REV.O 8.1.20 Instrument Valves for P & ID (Cont'd) THREE WAY VALVE, ‘e SELF CONTAINED BACK (FAIL OPEN TO PATH A-C) —4 [4 | PRESSURE REGULATOR la FOUR WAY VALVE, (FAIL OPEN] [Ay BACK PRESSURE REGULATOR c B TO PATHS A-C AND D-8) WITH EXTERNAL | PRESSURE TAP MOTOR OPERATED VALVE (GATE) LOCALLY OPERATED 8.1.21 Instrument Valves for P & ID (Safety) sy) PRESSURE SAFETY VALVE OL, THERMAL SAFETY VALVE PRESSURE RELIEF/VACUUM RUPTURE DISC BREAKER VALVE (FOR TANKS) 1 (PRESSURE RELIEF) M RUPTURE DISC (VACUUM BREAKER) DOC.No.EG-DO-C-001 PAGE 40 OF 109 REV.O 8.1.22 Typical Instrument Connections 8.1.22.a Pressure Instrument Connections (For Notes See Page No.42) TYPE DETAIL P&I D REPRESENTATION SINGLE PRESSURE INSTRUMENTS, 2" inst a ‘LPIPING Pe MULTIPLE PRESSURE INSTRUMENTS. 3a" INST PIPING 8.2.22.b Dp Instrument Connections (For Nates See Page No.42) TYPE DETATL P&I D REPRESENTATION LEVEL PIPING L_INST 1 8.2.22.c Temperature Instrument Connections (For Notes See Page No.42) TPE DETAIL P&I D REPRESENTATION Te TEMPERATURE oo aw ‘TEMPERATURE La DOC.No.EG-DO-C-001 PAGE 41 OF 109 REV.0 8.1.22.d Level Instrument Conections (For Notes See Page No.42) Level Switches, Level Gauges, External Float (but Not DP Cells) TYPE DETAIL P&I D REPRESENTATION LEVEL SWITCH vent Xue SH 2 ist eine [inst (3/4 PIPING RAIN = LEVEL GAUGE VENT nw {> leet, |_insr Ist 3/0" DRAIN foreiNG DOC.No.EG-DO-C-001 PAGE 42 OF 109 REV.O 8.1.22.e Control Valve Manifold Conections (See Notes) PRESSURE whue ween T t t Det Det NOTES: 1. a, INSTRUMENT CONNECTIONS ARE TYPICAL ONLY. DETAILS SHALL BE MODIFIED ‘TO MATCH RELEVANT PIPING SPECIFICATION. ONLY LINE CLASS PIPING VALVES WILL BE SHOWN ON P8ID'S. FOR INSTRUMENT ISOLATION VALVES REFER TO INSTRUMENT HOOK-UP DRAWINGS. b, MEASUREMENT AND CONTROL INSTRUMENT SHALL BE INDEPENDENT OF SAFTEY INSTRUMENTS. c, ALL SHUTDOWN SWITCHES FOR PROCESS PARAMETERS SHALL HAVE INDEPENDENT TAPPING FOR EACH OF THEM d, ALL INSTRUMENT CONNECTIONS AT HIGHER PRESSURE (CLASS 900 & ABOVE) ‘SHALL BE PROVIDED WITH DOUBLE INSOLATION VALVES. 2. a. HYDROCARBON VENTS AND DRAINS FROM LEVEL INSTRUMENTS & CONTROL VALVES SHALL BE CONNECTED TO THEIR RESPECTIVE DISPOSAL SYSTEMS. b. TYPICAL LEVEL BRIDLE SHOWING ISOLATION VALVES, VENTS & DRAINS. ALL DETAILS TO BE MODIFIED TO MATCH TO RELEVANT PIPING SPECIFICATION. LINE CLASS VALVES ARE INDICATED, INSTRUMENT VALVES ARE NOT SHOWN. c, LEVEL SWITCHES TO HAVE SEPARATE VESSEL NOZZLES WHEN INTERLOCKED WITH ESD SIGNALS, 3. SHOW BALL VALVE FOR HYDROCARBON SERVICE. SHOW GATE VALVE FOR NON-HYDROCARBON SERVICE. DOC.No.EG-DO-C-001 PAGE 43 OF 109 REV.0 8.1.22.f _ Level Bridle Presentation (For Note-2 See Page No.42) TYPICAL LEVEL BRIDLE DETAIL P&I D REPRESENTATION LEVEL BRIDLE WITH STAND PIPE vent VENT Sap VesseL En De OR . TANK ‘ * vesset & oR 2 TANK 344 pe SRN ype oun bn our TOTTORI us INSTRUMENT CONNECTION i “UG A, LEVEL GAUGE (16) 1 heal 8. LT (O/P CELL TYPE) : 3/4” C. LT (DISPLACEMENT TYPE) : 2 ERNAL TYPE) : 1" (INSTRUMENT VALVES ARE NOT SHOWN) LEVEL BRIDLE WITHOUT STAND PIPE vent, we z + * >—_ VESSEL OR “ TANK vessel a . OR TANK 2 = i oS DRAIN 1/2 + INSTRUMENT CONNECTION Lf a A LEVEL GAUGE (LG): 1" | “ 8. Lr (O/P CELL TPE) 13/8" ne a €. LT (DISPLACEMENT TYPE) : 2 TTT TT “ts D. LS (EXTERNAL TYPE): 1 o2 -.G Lif) (INSTRUMENT VALVES ARE NOT SHOWN) DOC.No.EG-DO-C-001 PAGE 44 OF 109 REV.0 8.1.23 Typical Shutdown and Vent Valves 8.1.23.a Double Acting ESD Actuator TYPICAL INSTRUMENT AIR HOOK-UP'S FOR ALL ‘SHUTDOWN/VENT VALVES (NOTE 1) PAD [Patt AL KE aA Ay =) — —- a S/D ¥ I VENT * 8,1.23.b Single Acting ESD Actuator im) | Zs ADA At * CHANGE SYMBOL FOR DCS BASED LOGIC TO SUIT NoTI 1. SINGLE OR DOUBLE ACTING ACTUATOR TO BE SELECTED IN ACCORDANCE WITH REQUIRED VALVE OPENING/CLOSING SPEED AND TORQUE. DOC.No.EG-DO-C-001 PAGE 45 OF 109 REV.0 8.1.24 Safety Blow Down Valve, Emergency Shutdown Valve 8.1.24.a Safety Blow Down Valve Controlled By ESD Logic DETAILS PID REPRESENTATION wy fos [a | 4 ! ® | ® . ' ® a ! NX @) bi ven} Koo \ 5 a) Le wore? root AL >| 1 1 ‘SBDV “pe dy mn a Oh NOTES 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT AIR ACCUMULATOR. DOC.No.EG-DO-C-001 PAGE 46 OF 109 REV.0 8.1.24.b Emergency Shut Down Valve Controlled By ESD Logic DETAILS P&ID REPRESENTATION IND, RESET START ACCEPTED Hs xoxe oI Not / os 7 Nore 1 e222! READY FOR RESET = HS \RESET XC CLOSE OPEN : “Fie XXX = LOOF zc) / z10 20) 900K 7 7 t t P NUMBER esov Xxx NOTES 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT AIR ACCUMULATOR. DOC.No.EG-DO-C-001 PAGE 47 OF 109 REV.0 8.1.24.c ESDV-Controlled by ESD Logic and Process Interrupt Logic DETAILS P&ID REPRESENTATION IND. RESET READY FOR START ACCEPTED RESET 5) ai = meas / S ates ' ae) b c10se ope 8 As ze | [210 note 2 esov 20x XXX = LOOP NUMBER NOTES 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT ‘AIR ACCUMULATOR. 3. PROCESS INTERRUPT LOGIC SIGNAL. DOC.No.EG-DO-C-001 PAGE 48 OF 109 REV.0 8.1.24.d ESDV-Controlled by ESD Logic and Compressor Anti-surge Control P&ID REPRESENTATION DETAILS IND, _RESET READY FOR START ACCEPTED RESET Hs ue cas 00 2D, yore) XRD! oe t ' Process / oe INTERRUPT Nt XXX = LOOP NUMBER NOTES ‘AIR ACCUMULATOR. 3. PROCESS INTERRUPT LOGIC SIGNAL. 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT DOC.No.EG-DO-C-001 PAGE 49 OF 109 REV.0 8.1.24.e Emergency Shut Down Valve Controlled by ESD Logic and ESD Logic Output. DETAILS P&ID REPRESENTATION RESET READY FOR RESET IND, HS. XC 1 Hl ' ' « 1 wn) oN I 8 open ® g™ [20 Be sv F etose ol a XXX, “fe tof XXX = LOOP NUMBER (21222) NOTE 1 NOTES 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT ‘AIR ACCUMULATOR. DOC.No.EG-DO-C-001 PAGE 50 OF 109 REV.0 SBDV-Controlled by ESD Logic and Compressor Start-up Control 8.1.24.F DETAILS P&ID REPRESENTATION AvRABLE CLOSE o7eN process oe neeaeust . ‘AIR ACCUMULATOR. 3. PROCESS INTERRUPT LOGIC SIGNAL. OPEN Nore 3 N 210 N Note 1 ‘ 20K © xsv w - ® 208 5) - © NoTE 2 AL 200K = LOOP NUMBER NOTES 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX 2. ALL BLOWDOWN VALVE & ESDVS TO BE PROVIDED WITH A DEDICATED INSTRUMENT DOC.No.EG-DO-C-001 PAGE 51 OF 109 REV.0 8.1.24.9 Motorized Valve with ESD Logic Output DETAILS P&ID REPRESENTATION OPENS cuose|"Hs NOTE 1 LOCAL/OFF f Or 0 t NOTE 1 1 LocaLy’ " REMOTE XXX = LOOP NUMBER NOTE: 1. FOR PROCESS SHUTDOWN LOGIC REFER TO CAUSE AND EFFECT MATRIX DOC.No.EG-DO-C-001 PAGE 52 OF 109 REV.0 8.1.24.h Motorized Valve DETAILS P&ID REPRESENTATION oren| “us aap 71 ' ' I ' ' I { cose ws) oo ' OPEN “HS \ Yoon I stois\ 1 \wosy i cose Hs) | Sor" 1s oven ' zc) a0.) \ a LOCAL/OFF 20%) 9006) G0 REMOTE (HS 7 7 ¥ t KG i 1 1 REMOTE Soe ' 20K \ 900 = LOOP NUMBER DOC.No.EG-DO-C-001 PAGE 53 OF 109 REV.0 8.1.25 Motor Operated Valves 8.1.25.a Typical Mov Circuit-local Operation RED RED GREEN GREEN JOPEN OPEN] [ores ‘STOP fe OSE |CLOSE CLOSE i I I I if I I I i | ' it I tite _4 ALL INSTRUMENTS TO CARRY THE SAME TAG NUMBER AS CORRESPONDING MOV'S. 8.1.25.b Remote Operated Valve DETAILS P&ID REPRESENTATION OPEN REMOTE Hs ue KR), OOK, Close OPEN zc) | z10 cLose Hs 2008, Rov XXXX px XXXX = LOOP NUMBER (notes 1,2) NOTES 1. DURING REMOTE OPERATION CONTINUOUS DEPRESSING OF OPEN OR CLOSE SOFT PUSH BUTTON ON DCS OPERATOR INTERFACE CAUSE VALVE TO TRAVEL. RELEASE OF SOFT PUSH BUTTON LEVELS VALVE IN LAST POSITION. 2. TYPE OF VALVE SHALL BE AS SHOWN ON RESPECTIVE P&ID. DOC.No.EG-DO-C-001 PAGE 54 OF 109 REV.O 8.1.26 Motor Instrumentation NOTE 2 RUNNING DUTY/STANDBY buat °-°-°—" fag} 2-2-0] SELECT STOPPED. MOTOR UL START avaitaste O° : UL) NOTEL => 6 REMOTE = $ UA I 6 00K i Furr ° STOP WAN. 0-0-0 Gs -0-0-0-0-f HS EMERG. stop 2 |i A) NOTE 1 + LoGic HARDWARE Xm) £805 (ESD, SSLS, OR DCS) ¥ 4 RELAY INTERFACE PANEL ' 4 mee _.| motor STARTER 7 {UBSTATION! (NOTES 4,5 i MOTOR NOTE 3 LOCAL CONTROL PANEL OR STATION 711 to LOCAL/OFF/REMOTE STOP START NOTES: 1. XXXX = LOOP NUMBER 2. DUTY SELECT & REMOTE/LOCAL SWITCHES REQUIRED ONLY WHEN AUTO-START OF STAND BY MOTOR IS SHOWN ON RESPECTIVE P&JD DIAGRAM 3. EACH MOTOR DOES NOT NECESSARILY NEED ALL THESE FEATURES, AND MAY REQUIRE OTHERS. REFER ELECTRICAL DWGS. AND P&ID FOR SPECIFIC MOTOR APPLICATION DETAILS| AS WELL AS BUT NOT LIMITED TO KOC-I-001 SECTION 9.10,015-JH-1911 SECTION 5,8 4, EITHER A MOTOR LOCAL CONTROL PANEL OR A MOTOR LOCAL PUSH BUTTON STATION MAY BE IMPLEMENTED. 5, MOTOR STATUS INFORMATION SHALL BE HARDWIRED VIA THE RELAY INTERFACE PANEL TO THE ESD/SSLS. DOC.No.EG-DO-C-001 PAGE 55 OF 109 REV.0 8.1.27 __ Sample Connection Arrangements 8.1.27.a Stream : Gas (Note-1) DETAIL P & I D REPRESENTATION SC-A) SAMPLE BOMB. sc NOTE: SHORT AS POSSIBLE. 1, SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS DOC.No.EG-DO-C-001 PAGE 56 OF 109 REV.0 8.1.27.b Stream : Oil, Water (Note-1) P &I D REPRESENTATION >t = = te Ts = s sh, x § Dat Dat QO sc-8) aja" 3/4 sc (3/4°x1/2" Vl 1/2" 8.1.27.c Stream : Water (Note-1) DETAIL P & I D REPRESENTATION 3/4" MIN. 3/4"x1/2" Li 4/2" NOTE: SHORT AS POSSIBLE. 1. SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS DOC.No.EG-DO-C-001 PAGE 57 OF 109 REV.0 8.1.27.d Stream : Oil DETAIL P &I D REPRESENTATION —— 3/4" 3/4" 12" -—xt- kn 3/4%1/2" MIN, 4/2" C15A_| NOTE-2 Do sc 8.1.27.€ Stream : Gas, Hp Condensate DETAIL P & I D REPRESENTATION ] — 3/4" CASA | NOTE-2 [sp BD sya" Nayar NOTE-3 BY LAB. 4/2" H 3/4"x1/2" 1/2"NTP. SAMPLE BOMB QUICK DISCONNECT: sc NOTE! 1. SAMPLE POINTS SHALL BE EASILY ACCESSIBLE SAMPLE LINES SHALL BE AS SHORT AS POSSIBLE. 2. THE PIPING MATERIAL CLASSES FOR ALL SAMPLE PIPE FITTINGS, VALVES AND BRANCHES SHALL BE SAME MATERIAL CLASS AS THE SAMPLE LINE ORIGINATES UNLESS OTHER WISE INDICATED IN THE DRAWING. 3. MINIMUM DISTANCE IS 500 mm WHEN SAMPLE IS CONDENSATE, DOC.No.EG-DO-C-001 PAGE 58 OF 109 REV.0 8.1.28 __ Injection & Sample Nozzle 8.1.28.a Chemical Injection , All Chemical Except Anti-Form |-—1/2" PIE 2" PIPE -——2"x1/2" REDUCED | SLIP-ON FLANGE 45° BEVEL 8.1.28.b Anti-Form (j-—2" Pre x12" ——V__ 3/2 Pape 2" PIPE = 2"x1/2" REDUCED SLIP-ON FLANGE 45° BEVEL 8.1.28.c _ Wash Water Injection |-—— 3" PIPE 6" PIPE 6"x3" REDUCED. SLIP-ON FLANGE 45° BEVEL DOC.No.EG-DO-C-001 PAGE 59 OF 109 REV.0 8.1.28.d Sample Nozzle for Tank and Desalter L TANK OR VESSEL 2" FLANGE 1" OR 3/4" 2"x1/2" REDUCED SLIP-ON FLANGE 2" NOZZLE 8.1.29 _ Corrosion Coupon DETAIL P & I D REPRESENTATION py -— nut FLOW SOLID PLUG PRIMARY PACKING —— PROTECTIVE COVER COUPON HOLDER —— 2"x3" STRIP CORROSION COUPON COXXK DOC.No.EG-DO-C-001 PAGE 60 OF 109 REV.0 8.1.30 Typical Pump Casing Vents & Drains On Suction Discharge Lines & Base Plate Drains 8.1.30.a UP TO 300# (80) sso 38 cE 3008 a» re yan ays we 3/8" Ne ee we EAN EA ONC | so0e 150% 8.1.30.b FROM 600# AND UP lasoe aya NC | 6008 3ya" DOC.No.EG-DO-C-001 PAGE 61 OF 109 REV.0 8.1.31 Standard Hydrant and Fire Engine Suction Riser 8.1.31.a Standard Hydrant 3" INLET FLANGE CONNECTION 2.1/2" INSTANTENOUS FEMALE COUPLING TO BS 336 WITH MALE BLANK PLUG CONNECTED BY STAINLESS STEEL CHAIN BBA 62a 2a 242 3/4” DRAIN VALVE a 1s0# tt 6"-300# RF 300#) FB Bal VALVE GRADE KKRE KRRK 1065 mm, 12°-WF1000X-Q358, WATER RING MAIN Fis 8.1.31.b Fire Engine Suction Riser EAH 8°-150# GATE VALVE 12 CONCRETE FOUNDATION GRADE ‘ SKK FROM 12° FIRE WATER TANK DOC.No.EG-DO-C-001 PAGE 62 OF 109 REV.O 8.2 Piping Symbols 8.2.1 Piping Fittings TYPE OF FITTING SCREWED FITTINGS SOCKET FITTINGS PLAN GH cH ° ELBOW 4 90° ELBOW | ELEVATION fo fe PLAN Cc ec 45° ELBOW ELEVATION gx PLAN s ree Tee te ELEVATION ‘ £ ob PLAN s—HH4 tHOE4 LATERAL ELEVATION L mts ee CONCENTRIC > = PLAN/ELE.| - - swace | PAN/ELE.) | TBE=THREAD BOTH END PBE=PLAIN BOTH END ECCENTRIC mS i (ELEVATION) ‘TBE=THREAD BOTH END PBE=PLAIN BOTH END PLAN / UNION | gcevarion 43 ‘IE PLAN / runt couPLinc| es rua on +3 LE fiaur coupLING| eLevarion ——— et pluG | ELEVATION ar _— cap ELEVATION e—3 -E—4 DOC.No.EG-DO-C-001 PAGE 63 OF 109 REV.0 8.2.1 Piping Fittings (Cont'd) BUTT WELD FITTINGS & FLANGES. ‘TYPE OF FITTING ‘SINGLE LINE DOUBLE LINE PLAN om 90° ELBOW ELEVATION Ey GF PLAN cH e 45° ELBOW ELEVATION PLAN ro SF 3 Tee ELEVATION { ae PLAN C644 Seo} LATERAL ELEVATION —_ CONCENTRIC (PLAN/ELE.) i Cc REDUCER TX, 8F8orrom 8F-BOTTOM ECCENTRIC FLAT FLAT (ELEVATION) TF=TOP TF=TOP ce at Ce rat ANd <4 3 car ELEVATION 4g 3 SLIP-ON | PLAN / FLANGE | ELEVATION = BLIND PLAN / FLANGE | ELEVATION WELD NECK | PLAN / . 4 — FLANGE | ELEVATION --—-- orIFICE | PLAN / i eS FLANGE | ELEVATION blr DOC.No.EG-DO-C-001 PAGE 64 OF 109 REV.0 8.2.1 Piping Fittings (Cont'd) BUTT WELD FITTINGS AND FLANGES TYPE OF FITTING SINGLE LINE DOUBLE LINE PIPE WELD eS A sTue IN : TS STUB IN WITH REINFORCING PAD WELD SADDLE JP) RL EY a WRAP AROUND SADDLE SPLIT TEE Ik BARRED TEE WELDOLET INSULATED PIPE aCdiats INSULATING FLANGE REMOVABLE SPOOL DOC.No.EG-DO-C-001 PAGE 65 OF 109 REV.0 8.2.1 Piping Fittings (Cont'd) ‘TYPE OF FITTING BUTT WELD FITTINGS AND FLANGES: ‘SINGLE LINE DOUBLE LINE 4-WAY SUCTION COLLECTION HEAD EXPANSION BELLOWS SPECTACLE BLIND (CLOSED) SPECTACLE BLIND (OPEN) HAMMER / PADDLE BLIND OR SPADE RING SPACER Y-TYPE STRAINER WITH PLUG dt|t}t ts Y-TYPE STRAINER WITH GATE VALVE AND PLUG. T-TYPE STRAINER 1 "| x °T DOC.No.EG-DO-C-001 PAGE 66 OF 109 REV.0 8.2.1 Piping Fittings (Cont'd) ‘TYPE OF FITTING BUTT WELD FITTINGS AND FLANGES: SINGLE LINE DOUBLE LINE reves sain (TEMPORARY) ran a ea | Hes CONICAL TYPE STRAINER (TEMPORARY) BASKET TYPE STRAINER DUPLEX TYPE STRAINER TUNDISH WITH SAND COVER TUNDISH 8.2.2 Valves TYPE OF VALVES FLANGED SCREWED SOCKET E GATE VALVE Stl ELEVATION EEG Dore END ELEVATION END ELEVATION END E GLOBE VALVE xt ELEVATION E E KI I END ELEVATION END ELEVATION END DOC.No.EG-DO-C-001 PAGE 67 OF 109 REV.0 8.2.2. Valves (Cont'd) TYPE OF VALVES FLANGED SCREWED SOCKET Ded ped Te PLAN PLAN PLAN BALL VALVE a“ a aa pet tet @ |] Dt © ELEVATION END. ELEVATION END | ELEVATION END N N PLAN PLAN PLAN CHECK VALVE N @ ELEVATION END N ELEVATION EN © N ELEVATION EN S iS iS re PLAN PLAN CONTROL VALVE ©) ELEVATION END ELEVATION END @ a PLAN PLAN nus k k 1S= TS= RELIEF VALVE k Do- ELEVATION END euevation exp | ELEVATION END @i plan Puan puan ANGLE VALVE \7 g euevarion eno | euevarion eno | ELEVATION END PLAN PLUG VALVE iS ELEVATION END eS) Eo ct ES cy} ot ES oy ELEVATION ELEVATION DOC.No.EG-DO-C-001 PAGE 68 OF 109 REV.O 8.2.2 Valves (Cont'd) TYPE OF VALVES FLANGED SCREWED SOCKET PLAN BUTTERFLY VALVE —_ —_ NI ELEVATION END PLAN PLAN PLAN DIAPHRAGM VALVE y © ELEVATION EN iS ELEVATION EN iS ELEVATION END CHOKE VALVE 31 @ E rast | ELEVATION END ELEVATION EN @ E asc | g s foes] «| aye fo AMMETER CLAD SURFACE MOUNTED VOLTMETER BUSBAR GENERATOR EARTHBAR motor EARTH PIT @- | exnaust ran EARTH DOC.No.EG-DO-C-001 PAGE 76 OF 109 REV.0 8.5.1 Power (Cont'd) SYMBOL DESCRIPTION SYMBOL DESCRIPTION THERMAL OVERLOAD qHERY wu CABLE CAPPED END CABLE RISE ss TEE JOINT m CABLE FALL 1 Y JOINT CABLE SHOWN IN SECTION CABLE SHO) 1 BRAZED JOINT CABLE PROTECTION TILE CABLE PROTECTION “te | EXISTING OVERHEAD LINE POWER CABLE Fi EEDER PILLAR @ _| rertaence Numoen CONTROL CABLE JUNCTION BOX © REFERENCE NUMBER HEATER FEEDER REFERENCE NUMBER NEW CATHODIC PROTECTION GROUND BED EARTHING CABLE REFERENCE NUMBER WIRING CIRCUIT , SLASH EXISTING CATHODIC He INDICATES No. OF WIRES PROTECTION ANODE BED INCLUDE NEUTRAL WPL-L234 CIRCUIT HOME RUN, INDICATES NEW OVERHEAD LINE Ht No. OF CIRCUIT + NEUTRAL CABLE TAG REFERENCE No. Oo CABLE IN CONDUIT WATER HEATER mo CABLE IN TRUNK ‘STRAIGHT JOINT CABLE IN DUCT CABLE TRAY CABLE TRENCH NEW POWER/CONTROL CABLE EXISTING CABLE TO BE REMOVED/DISCONNECTED EXISTING POWER/CONTROL SPARE CORE CABLE —>— _| TAPED AND COILED 8.5.2 Schematic & Single Line Diagram _ NORMALLY OPEN x CIRCUIT BREAKER cad contac ° NORMALLY CLOSED ¢ ao Xo mcce CONTACT Mc NORMALLY OPEN f CONTACT-MANUAL RESET l FUSE NORMALLY CLOSED CONTACT-MANUAL RESET DOC.No.EG-DO-C-001 PAGE 77 OF 109 REV.O 8.5.2 Schematic & Single Line Diagram (Cont'd) SYMBOL DESCRIPTION SYMBOL DESCRIPTION FUSE SWITCH = PUSH BUTTON NORMALLY os OPEN CONTACT PUSH BUTTON NORMALLY SWITCHFUSE ote CLOSED CONTACT ISOLATOR ae CONTROL TRANSFORMER LEVEL SWITCH VOLTAGE TRANSFORMER, PRESSURE SWITCH PHOTOCELL DIRECT ON LINE STARTER VOLTAGE REGULATOR TEMPERATURE SWITCH CONTACTOR FLOW SWITCH CURRENT TRANSFORMER * |22z]@)olelelr, |i x1] Z|] AMMETER CAPACITOR oe CHANGE OVER SWITCH VOLTMETER oe DOUBLE POLE 2 POSITION CHANGE OVER SWITCH GENERATOR oe SINGLE POLE 2 POSITION S CHANGE OVER SWITCH MOTOR eS SINGLE POLE 3 POSITION RECTIFIER OR BATTERY 7 Ree Syne | BATTERY INVERTER © CONTACTOR COIL CCURRENT TRANSFORMER FOR RECTIFIER b, INSTRUMENT (CORE BALANCED) 3 INDICATE No. OF C.T. LOCAL/REMOTE VS] __| VARIABLE SPEED DRIVE 3A) | KOCALIREMOTE. OFFLOAD ISOLATOR t QFFLOAD ISOLATOR y ONLOAD ISOLATOR (AC23) ELECTRO-MECHANICAL am ‘| ERESTRO-M Ea | stancswree 8.5.3 Lighting SINGLE TUBE FLUORESCENT STANCHION MOUNTED ° LAMP FIXTURE (120mm LONG) LIGHTING FIXTURE oe _| tm Tue Fiuorescent oO CEILING MOUNTED LAMP FIXTURE (1200mm LONG) ~ LIGHTING FIXTURE SINGLE TUBE FLUORESCENT A LIGHTING FDCTURE CAMP FOXTURE MODULAR RECESSED 3 LIGHTING FDCURE FITTING (1200mm LONG) DOC.No.EG-DO-C-001 PAGE 78 OF 109 REV.O 8.5.3. Lighting (Cont'd) SYMBOL DESCRIPTION SYMBOL DESCRIPTION TWIN TUBE FLUORESCENT - LAMP FIXTURE MODULAR RECESSED +O LTOHTING poCuRE FITTING (1200mm LONG) = LIGHTING FIXTURE 4x18W € 10m HIGH FLOOD LIGHTING POLE = (600x600mm) WITH 2 Nos, LIGHTING FIXTURE LIGHTING FIXTURE 3x18W (Gouxeoomn) Dp FLOODLIGHT LIGHTING FIXTURE 3X36W ox 6m HIGH STREET FLOOD (600x600mm) LIGHTING POLE BULKHEAD LIGHTING ep EMERGENCY LIGHTING UNIT FIXTURE 200W LAMP = SELF-CONTAINED BATTERY PACK] BULKHEAD LIGHTING. FIXTURE 100W LAMP WALL WASH RECESSED MOUNTED LIGHTING FIXTURE EMERGENCY EXIT SIGN EUMRCEROOE LUMINarRE ® DOWNLIGHT LIGHTING FIKTURE DOUBLE SIDED ENERGENCY SINGLE POLE GE | EXIT StaN Faneenoor < owe warswrrcn EMERGENCY EXIT STGN SINGLE POLE bene LUMINAIRE < TWO WAY SWITCH HT RECESSED SOMNTIGTTS FRTURE FU SHARNEE Hanne ITH INTEGAAL CONTROL GEAR SINNER CONTROL | TRECESSED DowncignTs FIXTURE 7oW DOWNLIGHT ADWUSTABLE of | mrnrecea conrao. coat © | Conrmouteo er omanek SUF CONTA EMERGENCY SwiTcn > Twat wounre DOUBLE POLE ea EXIT LIGHT “ ONE WAY SWITCH He | SURFACE MOUNTED e [reteue pou ENERGENCY LIGHTING One War SWITCH 7 2BW LOW ENERGY @ LUMINAIRE ‘ail MIRROR LIGHTING 7a ow een NRE o EMERGENCY VERSIONS, SUITABLE a ONE No. SPOTLIGHT FOR ESCAPE ROUTE LIGHT Fe FUE Nos. BACK TO BACK XC | BHO Nos BACKTO BACK SPOTLIGHTS Spores PENDANT MOUNTED (1)-TUBE PENDANT MOUNTED (2)-TUBE | Fluorescent vanpricrune | =! |ruWonescent Lane FOCTURE 8.5.4 Telecommunication TELEPHONE > DUAL LAN OUTLET 108) DISTRIBUTION BOARD DUAL RJ11 TELEPHONE ™ b OUTLET ao TV OUTLET DUAL LAN OUTLET © DUAL LAN OU ce KRONE TELEPHONE IDF DUAL RoI TELEPHONE DORR RINETEAMerRoor | CS] | KRONE TELEPHONE NOF DOC.No.EG-DO-C-001 PAGE 79 OF 109 REV.0 8.5.5 Fire Alarm System SYMBOL DESCRIPTION SYMBOL DESCRIPTION me SMOKE DETECTOR FIRE ALARM PANEL SHOKE DETECTOR, S| SMOKE DETECTOR (OTZATION a MANUAL CALL POINT © TYPE) IN FALSE FLOOR AREA a FIRE ALARW BELL @© _| eave-oF ise wear vevecron res [FIRE ALARN FLECTRONTC RATE-OF RISE HEAT DETECTOR fel | sounver FUAMEPROOF | Seaman GH] __|ceyguste cas oeeron ASHER MOUNTED ON THE ROOF AWEPROOF 8.5.6 Earthing Tone | Ste? EaTNG OE © SRTING AOD WAT WaIBED Troon? canine cue @ EARTHING TEST WEIL FOR PAVED AREAS 95mm? EARTHING CABLE EARTHING TEST WELL FOR UNPAVED AREAS 7Omm? EARTHING CABLE EARTHING BARE COPPER STRIP a | 35mm? EARTHING CABLE ARMOUR EARTHING 4 EXOTHERNTC WELD EARTHBAR 8.5.7 Building JUNCTION BOX, PULL BOX OR CONDUIT BODY (ISTING CONDUIT OR CABLE JUNCTION BOX, PULL BOX OR TERMINAL BOX IN CEILING CONDUIT EXPOSED ON WALL OR —_ CENTER LINE OF COLUMN OR BEAM —o-— ot} wr FLEXIBLE WIRING CONDUIT CONCEALED IN OR BELOW GRADE FLOOR 3/4" CONDUIT TELCOMM SYSTEM _ ______ | u/e power, conrrot on INSTR — 4.4/2" CONDUIT CABLE TEL/COMM SYSTEM 2 _|sorourrur ZZ ° CONDUIT VERTICAL RUN =] _[ inmtoor anceways natn aun —_— CONDUIT DOWN ara TNFLOOR RACEWAYS BRANCH RUN 5 | ELEVATION CONDUIT RUN CHANGE IN INFLOOR RACEWAYS TAG No, & MATERIAL ITEM No. DOC.No.EG-DO-C-001 PAGE 80 OF 109 REV.O 8.5.8 Relays & Metering SYMBOL DESCRIPTION SYMBOL DESCRIPTION @® ‘TEMPERATURE RELAY INVERSE DEFINITE MINIMUM TIME EARTHFAULT RELAY ae ® MOTOR WINDING TEMPERATURE RELAY LOCKED ROTOR OIL TEMPERATURE INDICATOR WITH ALARM & TRIP CONTACTS OVER VOLTAGE RELAY WINDING TEMPERATURE INDICATOR WITH ALARM & TRIP CONTACTS BUCHHOLZ GAS SURGE REL UNDER VOLTAGE RELAY OIL LEVEL ALARM RELAY UNDER VOLTAGE RELAY WITH OIL PRESSURE RELIEF DEVICE WITH ALARM & TRIP CONTACTS ®|@/@/@/@ RESTRICTED EARTH FAULT RELAY SSTARTS/HOURS a DEFINITE TIME DELAY ANNUNCIATOR RELAY @ BUCHHOLZ RELAY @ REVERSE POWER RELAY INVERSE DEFINITE MINIMUM TINE DIRECTIONAL O/C RELAY ‘TEMPERATURE DEVICE FOR BEARING a INVERSE DEFINITE MINIMUM TIME DIRECTIONAL E/F RELAY EXCITATION RELAY INSTRUMENT DATA TRANSMITTER ‘A-ANALOGUE CONSTANT NEGATIVE PHASE SEQUENCE AUTO RECLOSE RELAY INVERSE DEFINITE MINIMUM TIME NEGATIVE SEQUENCE OVER CURRENT RELAY FREQUENCY RELAY 81U/81C INTERTRIP SEND/RECEIVE RELAY EXTENDED START RELAY MASTER TRIP/LOCKOUT RELAY MOTOR THERMAL OVERLOAD RELAY DIFFERENTIAL PROTECTION RELAY @|@|@| @ |oja/@ DIFFERENTIAL PROTECTION RELAY FREQUENCY FAULT DEFINITE TIME DELAY REVERSE. POWER RELAY INTERTRIP SEND RELAY TSTTRNEODS OVER LRT rau | RSTO RA OT it - TERS ETE MANO TE Gm) | Drescamenr eu mo sestAnT ete ERAT x VOLTAGE RELAY MOTOR STALLING RELAY DEFINITE TIME DELAY EARTH FAULT RELAY POWER QUALITY AND MAXIMUM DEMAND INVERSE DEFINITE MINIMUM TIME OVER CURRENT RELAY KILOWATT HOUR METER INVERSE DEFINITE MININUM TIME ‘STANDBY EARTH FAULT RELAY o KILOVOLT AMPERE REACTIVE METER @] @|@|@/@|@/@©|®|O©|@/@/@|@| ©| ©] ©|@|@/@]@] ©|@©|@} ® POWER FACTOR METER DOC.No.EG-DO-C-001 PAGE 81 OF 109 REV.O 8.6 Electrical Abbreviations ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION AIC AIR CONDITIONER: DISC DISCONNECT Aan AMPERE ppoT [DOUBLE POLE DOUBLE THROW ne [ALTERNATING CURRENT best [bouste Pove since THROW Af [ADJUSTABLE FREQUENCY ORiVE]) EARTH AFF | ABOVE FINISHED FLOOR eA EACH AU [AIR HANDLING UNIT aL EARTH LEAKAGE ‘APPROX APPROXIMATE E/F EARTH FAULT ARCH ARCHITECTURE ELEC ELECTRICAL ASN [ASYMMETRICAL eueRe [EMERGENCY AUTO. AUTOMATIC EQUIP EQUIPMENT aK AUXILIARY er ELECTRONIC TRIP BAT [BATTERY Ewe [ELECTRIC WATER COOLER BC BATTERY CHARGER FA FIRE ALARM iL BASIC INSULATION LEVEL FACE [FIRE ALARM CONTROL PANEL BMS BUILDING MANAGEMENT SYSTEM FATB FIRE ALARM TERMINAL BOX C core For [FEEDER ce CIRCUIT BREAKER er FoxruRe CoN [CLOSED CIRCUIT TELEVISTON || FLA [FULL LOAD ANPERE ext [erncurr Fux | FueateLe conourT co CONDUIT OUTLET me FLUORESCENT LAMP CORR [COAXIAL CABLE ap FLOOD LIGHTING POLE ce CONTROL COIL ripe [FIRE LIMITING POWER cic CURRENT INTERRUPTING CAPACITY, FREQ FREQUENCY cr CONTROL RELAY ™ FREQUENCY METER cT CURRENT TRANSFORMER FVNR: FULL VOLTAGE NON-REVERSING cu COPPER FLC FULL LOAD CURRENT 38 DISTRIBUTION BOARD GET GROUND FAULT INTERRUPTER De DIRECT CURRENT Gud [@ROUND pcp DIRECT DIGITAL CONTROL HH HANDHOLE or DIGITAL INPUT WP HORSEPOWER DIA [DIAMETER OA __[HAND-OFF-AUTO DOC.No.EG-DO-C-001 PAGE 82 OF 109 REV.O 8.6 — Electrical Abbreviations (Cont'd) ABBREVIATION) DESCRIPTION ABBREVIATION DESCRIPTION PS __|RIGH PRESSURE SODIUM vo __| MULT-OUTLET pane HT HEIGHT Mov MOTOR OPERATED VALVE vain [ EATER vis8 | MAIN SWITCH BOARD ev____ [HIGH voUTAGE is¢___| MAIN SWITCH GEAR He HERTZ var [ MOUNTED I CURRENT MTG MOUNTING 1c INTEGRATED CIRCUIT Ne NORMALLY CLOSED rn LOAD CURRENT NEC | NATIONAL ELECTRICAL CODE 28 DUNCTION 80x yeuT | NEUTRAL ia KILO ANPERE WF NON-FUSED kv KILOVOLT NIC NOT IN CONTACT WA [KILOVOLT AMPERE NO [NORMALLY OPEN War [katovour awpene neacrive_|[ o/c [over cunnewr iw [eatowarr 05 [OUTSIDE oIAWETER kWh KILOWATT HOUR OL OVERLOAD RELAY LAN LOCAL AREA NETWORK PA PUBLIC ADDRESS ice [tocar conrmoL paver Pa PUSH BUTTON tie [uring Px [PANEL LQ LIQUID TIGHT CONDUIT PDB POWER DISTRIBUTION BOARD 5 LIGHTING PANEL = POWER PANEL w Low VOLTAGE Pa [ PRIMARY iF LOW TENSION Pr POTENTIAL TRANSFORNER M MOTOR PWR POWER wax [NaxIMU R RESISTOR McC MOTOR CONTROL CENTER RGS RIGID GALVANIZED STEEL wece [MOLDED case ciRcUT anEaKeR || RMU [RING MAIN UNIT ce | MINIATURE CIRCUIT BREAKER || RS | ROOT MEAN SQUARE wep [NoToR circurr pRorecror _||_RF RADIO FREQUENCY ween [MECHANICAL ner RADIOFREQUENCY Wes | NOLBED CASE Ewircn se SHORT clcuIr vw [MANHOLE scn___[screoue DOC.No.EG-DO-C-001 PAGE 83 OF 109 REV.O 8.6 _ Electrical Abbreviations (Cont'd) ABBREVIATION| DESCRIPTION ABBREVIATION DESCRIPTION DBC SOFT-DRAW BARE COPPER TREAT | TREATMENT SEC SECONDARY TR TRANSFORMER SHLD SHIELDED 1 TRANSMISSION LINE sQ SQUARE u/G UNDERGROUND STD STANDARD Vv VOLTAGE, VOLTS STOR STORAGE VA VOLT-AMPERE STR STRUCTURAL, STRANDED VAV VARIABLE ACTUATOR VALVE SP SINGLE POLE, SINGLE PHASE || VAC VACUUM suBST __ | SUBSTATION w WATT sw ‘SWITCH we WEATHERPROOF SWBD SWITCHBOARD Z IMPEDANCE ‘SWGR SWITCH GEAR 1» SINGLE POLE SYM SYMMETRICAL, 2P 2 POLE TB TERMINAL BOX 3P 3 POLE TEL TELEPHONE 4P 4 POLE TERM TERMINAL, oP 6 POLE Toc TOP OF CONCRETE 3w THREE WIRE Te TWISTED PAIR, TRIPLE POLE aw FOUR WIRE TPN TRIPLE POLE & NEUTRAL 8.7 Civil/Architectural Symbols 8.7.1 General GRID LINE IDENTIFICATION THIS IS USED TO SPECIFY THE DISTANCE (OF COLUMNS OR WALLS CENTER TO CENTER. WHEREAS THE INDICATED LETTERS AND. NUMBERS INSIDE THE CIRCLE COULD BE PLACED EITHER HORIZONTAL OR VERTICAL POSITION. WALL SECTION CUT THIS IS USED WHEN THE REFERENCE IS SHOWN THE SECTION DETAIL ON THE SAME SHEET WALL SECTION INDICATION SHALL BE LETTERS ONLY INSIDE CIRCLE DOC.No.EG-DO-C-001 PAGE 84 OF 109 REV.0 8.7.1 General (Cont'd) wD @ Roe BUILDING SECTION CUT TOP- SECTION IDENTIFICATION LETTER BOT- DRAWING ON WHICH SECTION IS SHOWN BUILDING SECTION INDICATION SHALL BE _ LETTERS ONLY INSIDE CIRCLE. SECTION TITLE SECTION TOP - SECTION IDENTIFICATION LETTER 1 TO BE SHOWN BELOW) XX. BOT - DRAWING ON WHICH SECTION IS SHOWN (WHEREAS A REPRESENT LETTER) DETAIL INDICATION DETAIL TOP - DETAIL IDENTIFICATION NUMBER (Seale 70 ge srOWN BELOW) XX-KRK BOT - DRAWING ON WHICH DETAIL SECTION IS SHOWN (WHEREAS n REPRESENT NUMBER) N INTERIOR ELEVATION SYMBOL TOP - ELEVATION IDENTIFICATION NUMBER/LETTER ORE BOT - DRAWING ON WHICH ELEVATION IS DRAWN CORNERS - DIRECTION OF WALL ELEVATIONS DRAWN s (WHEREAS n REPRESENT NUMBER OR LETTER) 8.7.2 Doors 8.7.4 Kitchen & Toilet (Cont'd) REFRIGERATOR ™M DOUBLE DOOR — UNEQUAL WIDTH fa LAUNDRY SINGLE DOOR BA URINAL EASTERN WATER CLOSET 8.7.3, Windows 8 WINDOW o WESTERN WATER CLOSET aS WIDTH SHALL BE VARIES WHAT TYPE TO BE USED 6 BIDET 8.7.4 Kitchen & Toilet ® LAVATORY ELLIPTICAL TYPE STAINLESS STEEL SINK 1 LAVATORY SQUARE TYPE STAINLESS STEEL SINK 2 i SHOWER TUB STAINLESS STEEL SINK 3 BATH TUB atel GAS RANGE 1 8 FLOOR DRAIN GT | GULLY TRAP oO VENT PIPE DOC.No.EG-DO-C-001 PAGE 85 OF 109 REV.0 8.7.5 Materials 8.7.5 Materials (Cont'd) EARTH (ZZZZLA | STEEL CONCRETE RIGID INSULATION WIA | CONCRETE BLOCK MMA ~| wooo Zl | SAND LIME BRICK 8.7.6 Walls BLANKET INSULATION EXTERIOR COMPOSITE 4 | watt 250mm) PLYWOOD BOARD REINFORCED FULL HEIGHT CONCRETE WALL (150mm) TERRAZZO TILE 2-HR RATED, 200mm THICK NATURAL STONE B__ | ANE Arent Coxcaere E BLOCK FIRE SEPARATION GYPSUM BOARD WALL “in paren congrooR ACOUSTIC CEILING TILE B_ | BAR ESTES SGT RRSn £ FLOOR SLAB TO UNDERSIDE cenawic The Oe STRCTURe ABOVE 8.7.7. Miscellaneous EXTERNAL ELEVATION TITLE Bs TOP- ELEVATION IDENTIFICATION LETTER \QOEK-XX BOT- DRAWING ON WHICH ELEVATION IS SHOWN ROOM NUMBER . (WHEREAS n REPRESENT NUMBER) DOOR TYPE NUMBER USED FOR DOOR SCHEDULE (WHEREAS n REPRESENT NUMBER & LETTER) USED FOR WINDOW SCHEDULE (WHEREAS n REPRESENT NUMBER & LETTER) © eS YUNDOW TYPE NUMBER WALL FIRE RATING 1-ONE HOUR FIRE RATING 2-TWO HOUR FIRE RATING 3-THREE HOUR FIRE RATING (WHEREAS n REPRESENT NUMBER) INDICATE VALUE OF FINISH LEVELS OF ANY FINISH LEVEL a~_sesr SURFACE FOR CIVIL OR ARCHITECTURAL DRAWINGS = RECESS WALL MOUNTED FAC FIRE HOSE CABINET SLOPE DIRECTION OF FALL FOR SLOPING FLOOR/ROOF SUSPENDED ACOUSTIC TILES 600mm x 600mm. LAY-IN GRID UNLESS NOTED OTHERWISE DOC.No.EG-DO-C-001 PAGE 86 OF 109 REV.O 8.8 Civil/Architectural Abbreviations ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION AIC AIR CONDITIONING BLDG BUILDING scr] agcmyeonenere uk __ toe ACOUS ACOUSTICAL BM BENCH MARK ACU AIR COOL CONDENSING UNIT] BOS BOTTOM OF STEEL AFF “AFFLUENT BS BRITISH STANDARD AFFLR ABOVE FINISHED FLOOR B/w BOUND WALL AIG ABOVE GROUND BW BOTH WAY APPROX. APPROXIMATELY CARP, CARPET ARHCL ARCHITECTURAL CATL CATALOGUE ASTM ‘AMERICAN SOCIETY FOR oo CATCH BASIN AWS AMERICAN WELDING SOCIETY cl CAST IRON BCL BOTTOM OF CONCRETE LINTEL |} C/L CEILING LEVEL BCLVT BOX CULVERT CLKG CAULKING DOC.No.EG-DO-C-001 PAGE 87 OF 109 REV.O 8.8 — Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION co CONCRETE OPENING Dv DIVISION cLo CLEAN OUT DL DEAD LOAD COL ‘COLUMN DN DOWN coMB ‘COMBINATION DP DRAIN PIT COMBFTG COMBINED FOOTING DPC DAMP PROOF COURSE ‘COMPO COMPOSITION (COMPOSITE) |]_DR DOOR ‘CONC CONCRETE ps DOWN SPOUT CONN CONNECTION Dwr DRAWER CONSTR CONSTRUCTION DwG DRAWING CONT CONTINUOUS, CONTINUE EXP EXPOSED, EXPOSURE CONTBM CONTINOUS BEAM ELEC PNL ELECTRICAL PANEL, CONTFTG CONTINOUS FOOTING E EAST cu COPPER EA EACH CORR CORRUGATED EF EARTH FILL ‘CORD CORRIDOR EFF EFFLUENT. cP CATHODIC PROTECTION EFN EXHAUST FAN CNTR COUNTER 5 EXPANSION JOINT cum / mi? CUBIC METER EL ELEVATION (HEIGHT) crst CONCRETE REINFORCING lle ey ELEVATION (VIEW) csMT CASEMENT ELEC ELECTRICAL cr CERAMIC TILES EMERG EMERGENCY on CYLINDER, CYLINDRICAL ENCL ENCLOSURE DET DETAIL EP ELECTRICAL POLE DF DRINKING FOUNTAIN EQ EQUAL DIA DIAMETER EQPT EQUIPMENT DIAG DIAGONAL EQUIV EQUIVALENT DIM DIMENSION EW EACHWAY DISCH DISCHARGE ewe ELECTRIC WATER COOLER DISP DISPENSER EXTG EXISTING DIST DISTANCE EXT EXTERIOR DOC.No.EG-DO-C-001 PAGE 88 OF 109 REV.O 8.8 — Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION TA FINE AGGREGATES FuRN FURNITURE Face FIRE ALARM CONTROL PANEL | FR FRAWE Fars FIRE ALARM PULL STATION || cc GAUGE #0 FLOOR CLEAN OUT GA GENERAL ARRANGEMENT FD FLOOR DRAIN GALV GALVANIZED FDR FIRE DOOR GENL CONT GENERAL CONTRACT mK FIRE EXTINGUISHER ci GALVANIZED IRON FRE BxtT os GLASS FFL FINISHED FLOOR LEVEL GL GRADE LEVEL, GROUND LEVEL| Fri FACTORY FINISH ser GASKET re FIRE FIGHTING VALVE Prt | vee | GYPSUM BOARD ma FIRE HYDRANT 4 GH Fac FIRE HOSE CABINET "8 HOSE BIB Pas FLATHEAD MACHINE SCREW | 480 HARDBOARO FHWS FLATHEAD WOOD SCREW HC HOLLOW CORE iG FIGURE HOR HEADER FN FINISH ow HARDWARE x FIXTURE Gr HEATING a Flow LINES 7 HOLLOW METAL FW FIRE WATER HORZ HORIZONTAL AR rLooR WP HIGH POINT rior | ALUORESCENT wo aRDWOOD FND FOUNDATION HR HOUR Foc FACE OF CONCRETE aT HEIGHT Fom FACE OF MASONRY vac HEATING, VENTILATING AND FOS FACE OF STUDS ID INSIDE DIAMETER 2 FIRE PANEL TW IRRIGATION NOZZLE mW FACE TO FACE isu, | INSULATION AG FooriNe ina INTERIOR mR FURRED i rwveRr DOC.No.EG-DO-C-001 PAGE 89 OF 109 REV.O 8.8 Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION TWRR INDIRECT WASTE ROOF MACD MINA AHMADI RECEPTOR CONSTRUCTION DATUM JANCLO JANITOR'S CLOSET MATL MATERIAL 5 301sT MAINT MAINTENANCE 3B JUNCTION BOX MAX MAXIMUM anc SUNCTION MB MACHINE BOLT aT JOINT MD MID POINT kIT KITCHEN MECH MECHANICAL kg KILOGRAM MEMB: MEMBRANE km KILOMETER MET METAL kN KILO NEWTON MEZZ MEZZANINE kPa KILO PASCAL M/F MANIFOLD KPL KICK PLATE MFR MANUFACTURER LAB LABORATORY MH MANHOLE LAN LOCAL AREA NETWORK MICRO MICROWAVE OVEN LAM LAMINATED. MIN MINIMUM LAV LAVATORY MIR MIRROR ut LINEAR FOOT MISC MISCELLANEOUS Ls LENGTH, LONG. mm MILLIMETER UG SECT LONGITUDINAL SECTION MO MASONRY OPENING LH LEFT HAND MoD) MUDULE, MEDULLAR u LIVE LOAD MPa MEGA PASCAL LM LINEAR METER MRB MARBLE UNTL LINTEL MSY MASONRY LP LOW POINT MTG MOUNTING ut wr LIGHT WEIGHT MULL MULLION LvD LOUVERED DOOR N NORTH LVR LOUVER NA NOT APPLICABLE uwe LIGHTWEIGHT CONCRETE NIC NOT IN CONTRACT ™ METER NGL NATURAL GRADE LEVEL DOC.No.EG-DO-C-001 PAGE 90 OF 109 REV.0 8.8 Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION No. NUMBER R RADIUS Nom NOMINAL RA RETURN AIR NTS NOT TO SCALE RB RUBBER BASE oc ON CENTER RC REINFORCED CONCRETE oD OUTSIDE DIAMETER RCV REMOTE CONTROL VALVE OPH OPPOSITE HAND. RD ROAD O/H OVERHEAD ROR ROOF DRAIN OPNG OPENING REF REFERENCE opp OPPOSITE REFR REFRIGERATOR PB PANIC BAR REINFORCE, REINFORCED REINE REINFORCING PCLT PIPE CULVERT REINFORCEMENT PH PUMP HOUSE REV REVISION PL POINT OF INTERSECTION RH RIGHT HAND PL PLATE RM ROOM PLGL. PLATE GLASS RO ROUGH OPENING PLAS PLASTER ROW RIGHT OF WAY PLN PROPERTY LINE RR REMOVABLE RAILING PNL PANEL RT REMOVABLE TRANSOM PR PAIR RTN RETURN PRECONC PRECUTS CONCRETE RTW RETAINING WALL PREFAB PREFABRICATED RVS REVERSE PROJ PROJECT, PROJECTION RWP. RAIN WATER PIPE psf POUND PER SQUARE FEET s SOUTH psi POUND PER SQUARE INCH SA SUPPLY AIR PTD PAPER TOWEL DISPENSER sc SOLID CORE PIN PARTITION SCFF ‘SCAFFOLDING PTR PAPER TOWEL RECEPTOR SCHED SCHEDULE Pvc POLYVINYL CHLORIDE sD SADDLE PvMT PAVEMENT SEC SECTION Pwo) PLYWOOD | SHT SHEET DOC.No.EG-DO-C-001 PAGE 91 OF 109 REV.0 8.8 Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION sire SHEETING TcPW TOP OF CONCRETE PARAPET SHV SHELVE, SHELVING WALL sIM SIMILAR TCRS TOP OF CONCRETE ROOF SLAB| sk SKETCH TECH TECHNICAL, TECHNOLOGY skW SKEW, SKEWED TEL TELEPHONE SPK SPEAKER TEM TOP OF EMBANKMENT SPECS SPECIFICATION TEMP TEMPERATURE SPKR SPRINKLER TER TEZZARO sq SQUARE THK THICK sq.m/m? | SQUARE METER TP TYPICAL ss SERVICE SINK 16 TRANSFER GRILL s/s SUBSTATION TL TOWER LIGHT ssT STAINLESS STEEL TR TRANSFORMER RECTIFIER st STEET TRAN LN TRANSMISSION LINE STA STATION TRFS ‘TRANSFORMER STD STANDARD Toc ‘TOP OF CONCRETE STK ‘SEPTIC TANK TOASP TOP OF ASPHALT CEMENT st STEEL u URINAL sto STORE UBC UNIFORM BUILDING CODE sTOR STORAGE ups UNDISTURBED GROUND STR STAIR ws UNDERGROUND STRR STIRRUP UNFIN UNFINISHED STRUCT STRUCTURE UON UNLESS OTHERWISE NOTED UPL SUPPLY, SUPPLIER ues UNINTERRUPTED POWER suPP SUPPORT SuRP SURPLUS ueve UNPLASTICIZED POLYVINYL susP SUSPENDED CHLORIDE sw SEWAGE, SEWERAGE VAR VARIABLE SYM SYMBOL ve VINYL BASE syYMM ‘SYMMETRICAL VENT VENTILATION DOC.No.EG-DO-C-001 PAGE 92 OF 109 REV.O 8.8 — Civil/Architectural Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION VER VERIFY wi WROUGHT IRON VERT VERTICAL wrap WATER RESISTANT ACOUSTIC PANEL VEST VESTIBULE wsct WAINSCOT VF VINYL FABRIC Ww WELDED WIRE FABRIC vIN VINYL, & AND. vp VISION PANEL q CENTER LINE vp VALVE PIT @ AT STR VENT STACK THROUGH ROOF 9 DIAMETER vt VINYL TILE L ANGLE BAR w WEST c CHANNEL BAR w/ WITH I 1-BEAM WB WOOD BASE a SQUARE BAR we WATER CLOSET STEEL PLATE we. WIRE GLASS (Tort) | METRIC TON WD WOOD Gal GALLON woo WINDOW mg MILLIGRAM WH WATER HEATER ov QUART we WIRE MESH ASTERISK IS SHOWN WHEN w/o WITHOUT * THERE IS SOME SPECIAL NOTES TO BE EXPLAINED wo WINDOW OPENING we WORKING POINT F100 CFM | INDICATE FLOW DIRECTION DOC.No.EG-DO-C-001 PAGE 93 OF 109 REV.O 8.9 HVAC Symbols SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION DUCT (1ST FIGURE,SIDE Seeesgee | A |p ey NAY ‘SUPPLY OUTLET,CEILING, oO 20 ROUND (TYPEAS SPECIFIED) || 7 [—0 INCLINED DROP (0), IN DIRECTION OF AIR FLOW 42x12. | SUPPLY OUTLET,CEILING, hy] 212 | SQUARE (TYPE AS SPECIFIED) 700.CFM | INDICATE FLOW DIRECTION CONNECT NEW DUCT TO EXISTING DUCT w w D ol DUCT SECTION 30 X 12 12X30 (SUPPLY) web WD LIMIT OF DEMOLITION a (EXHAUST OR RETURN) SUPPLY AIR REGISTER (SAR) ry Ir ul FLEXIBLE DUCT FLEXIBLE CONNECTION RETURN AIR GRILLE (RAG) FACE BLADES TURNING VANES RECTANGULAR ELBOW i =A WITH HOR. FIXED i RETURN AIR GRILLE (RAG) EGG CRATE STYLE VANED ELBOW ‘SHORT RADIUS SUPPLY AIR DIFFUSER (sap) STANDARD RADIUS ELBOW RETURN AIR DIFFUSER (RAD) DIRECTION OF FLOW RETURN 48% STANDARD BRANCH FOR ‘SUPPLY AND RETURN NO SPLITTER (45° TAP) DOC.No.EG-DO-C-001 PAGE 94 OF 109 REV.0 8.9 HVAC Symbols (Cont'd) SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION AUTOMATIC. ‘TRANSITIONS DUCT: VOLUME DAMPERS Give SZESNOTE MOTOR OPERATED | (eon FLATON TOP OR (ros) aroNsorrom || @®y Oy PF APPUCABLE PET, | eneonuren tt ‘SD) Vaneo ELaow & @ AIR SPLIT TYPE DUCT Z T 2 SMOKE DAMPER TAKE-OFF i DUCT WORK WITH BACK DRAFT DAMPER ACOUSTICAL LINING POINT OF CHANGE WN TERMINAL UNIT BOT CONSTRUCTION (y Ghee nab STATIC PRESSURE GLASS) OR SCHEDULE) REMOVED EXISTING DUCT TO BE COMBINATION DIFFUSER AND LIGHT FIXTURE EXISTING DUCT DOOR GRILLE TO REMAIN LOUVER OPENING <~st = | sounp trap (cow) SPLITTER DAMPER GOOSENECK HOOD VOLUME DAMPER wD MANUAL OPERATION FAN & MOTOR WITH BELT GUARD & FLEXIBLE CONNECTIONS, 7 | ACCESS DOOR (AD) cf ap = ort ACCESS PANEL (AP) cet VENTILATING UNIT (TYPE AS SPECIFIED) DOC.No.EG-DO-C-001 PAGE 95 OF 109 REV.0 89 HVAC Symbols (Cont'd) SYMBOLS DESCRIPTION SYMBOLS DESCRIPTION UNIT HEATER —— FY | spur type sol (COWNBLAST) FIN AIR CONDITIONING EVAPORATOR UNIT(EU) & CONDENSING UNIT(CU) Lx | untrieater saz) OY | (WALL MOUNTED) q ie (HORIZONTAL) YS WINDOW TYPE Rin CONDITIONING UNIT, LETTER ! UNIT HEATER INDIGATES UNIT SIZE (CENTRIFUGAL FAN) PLAN AIR COOLED CONDENSING UNIT(CU) (FOR PACKAGE TYPE- AIR HANDLING UNIT) LOUVER & SCREEN ELECTRIC DUCT HEATER, rh f POWER OR GRAVITY ROOF} VENTILATOR -LOUVERED | +» ACh FRESH AIR INTAKE SAND POWER OR GRAVITY ROOF] | > | LOUVER WITH VENTILATOR -EXHAUST | 4° THICK METALLIC (ERY) ~U CLEANABLE FILTER, VCD & a WIRE MESH WITH END CAP POWER OR GRAVITY ROOF | |=*-| Qa [S-) EXHAUST FAN AIR LOUVER VENTILATOR “INTAKE ls] Sx| motor Tyee (SRV) SS FRESH AIR INTAKE 20 x12 8G > PRE] LOUVER WITH FILTER 2x12 SS_ | SUPPLY GRILLE (SG) | & VOLUME CONTROL 700 CFM ~ = DAMPER(VCD) 4 20 x12 RG RETURN (RG) OR EXHAUST \-~ | (&@) GRILLE(NOTE AT FLA INTAKE LOUVER 700 CFM ORGLG) @) | tHeawostar ‘SUPPLY REGISTER (SR) 20x12 SA_ | (AGAILLE + INTEGRAL 700 OFM VOLUME CONTROL) (00) DUCT DAMPER EXHAUST OR RETURN AIR po) 20x12 GR | INLET CEILING FD) FIRE DAMPER | “70'Gem | (INDICATE TYPE) ‘SMOKE DAMPER A EXHAUST FAN (EF) ISP| PROPELLER TYPE = WALL MOUNTED (SPO) SPLITTER DAMPER DOC.No.EG-DO-C-001 PAGE 96 OF 109 REV.O 8.10 HVAC Abbreviations ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ACH AIR COOLED CHILLER ‘CUH CABINET UNIT HEATER ACU AIR CONDITIONING UNIT cwP CONDENSER WATER PUMP ADP APPARATUS DEW POINT Do DRAIN anu AIR HANDLING UNIT oA DIAMETER Ae AMEN 08 ony BULB as AIR SEPARATOR ‘c DEGREE CELSUS/ 0 AUTOMATIC TEMPERATURE || oyg boom UNDER CUT 8 sour ow TEMPERATURE BFP BOILER FEED PUMP EF EXHAUST FAN ne BREAK HORSE POWER et EXPANSION TANK ou ams Taenvatunt || FU EVAPORATOR UNIT erun BRITISH THERMAL esp EXTERNAL STATIC PRESSURE co Coots Gor. evaP EVAPORATOR crm cuporcereeamnure || OEGREE FAHRENHEIT cH cmLER ra ESHA cHWP CHILLED WATER PUMP FAL FRESH AIR LOUVER cP CONDENSATE PUMP: FIA FROM ABOVE cs COMMISSIONING SET FB FROM BELOW cower COMPRESSION TANK ce HEATING CoML ELECTAC cT COOLING TOWER HP HORSE POWER ou CONDENSING UNIT Ww HEATING VENTRATING DOC.No.EG-DO-C-001 PAGE 97 OF 109 REV.O 8.10 HVAC Abbreviations (Cont'd) ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION woo | Reatmgyewmuaameno || peu ST LAT LEAVING AIR TEMPERATURE AL REFRIGERANT LIQUID NTS NOT TO SCALE SAR SUPPLY AIR REGISTER: PF PROPELLER FAN EVAPORATOR UNIT RAD RETURN AIR DIFFUSER TB TERMINAL BOX DOC.No.EG-DO-C-001 PAGE 98 OF 109 REV.0 9.0 PRINT ROOM OPERATING PROCEDURES 9.1 Introduction The print room, technically termed as Drawing Records Office is an important part of the Engineering Group coming under the Engineering Design Team handling all Engineering drawings of various sizes and discipline. The print room procedures consists of receipt of drawings from the originators, allotment of numbers, registration of drawings, microfilming, filing, and issue of prints for all the authorized requesters and users. 9.2 Reservation of Drawing Numbers The KOC shall reserve all Drawing Numbers of all disciplines in the Print Room through respective KOC authorised Personnel by the Form given below: 9.2.1 Drawing Number Reservation Form for KOC KUWAIT OIL CO. (K.S.C.) ENGINEERING GROUP DESIGN TEAM PRINT ROOM DRAWING NUMBER RESERVATION REQUEST Requested By KOC No Group Team Date. Telephone / Ext Proj No. + I the project is existing or the new drawing is related to existing drawings, please give the references. Project Tie Sr No Drawing Description Discipline | Dwg. No. Reserved secon The above drawings should be submitted together as one set Signature For Print Room Use Issued Chika. Cara} Snr. Operator Print Room Registered Collected DOC.No.EG-DO-C-001 PAGE 99 OF 109 REV.0 9.3 Drawing Registration The final drawings, Electronic files shall be submitted to the Print Room through the concerned KOC Controlling Team with the Form given below: 9.3.1 Drawing Registration Form for KOC KUWAIT OIL CO. (K.S.C.) ENGINEERING GROUP NEW DRAWINGS REGISTER TO PRINT ROOM Requested By Proj. No. Date Project Title Sr.No. | Drawing No, Drawing Tite Draughisman Name Signature For Print Room Use Snr. Print Room : DOC.No.EG-DO-C-001 PAGE 100 OF 109 REV.0 9.3.2 Drawing Revision Form for KOC Revised drawings with revision details to be submitted to the Print Room with the Form given below PRINT ROOM HISTORY (To be attached with Revision/Amendment Details) PLEASE WRITE BLOCK LETTERS OR PRINT IN BLACK & WHITE, THE DETAILS OF LAST REVISION. Request No. / Date Revision Date Drawing Nos. Revision Details 1 Rev 2 Rev 3 Rev ‘ i S 5 Rev 6 Rev 1 Rev 8 Rev 8 Rev Revised By Signature DOC.No.EG-DO-C-001 PAGE 101 OF 109 REV.0 9.3.3 Drawing Print Request Form for KOC / Contractor The KOC / Contractor shall request drawing prints through Print Room by the Printing request Form given below : Kuwait Oil Company (K.S.C.) ENGINEERING GROUP DRAWING PRINTS REQUEST FORM Group / Team Org. Code Drawing Reference Nos, Reapested For Print room use F Actions Name Signature | Tel. No. Requested ] Required Date Date REQUESTED BY ‘AUTHORIZED BY APPROVED BY COLLECTED BY Print Room (Record) DOC.No.EG-DO-C-001 PAGE 102 OF 109 REV.0 9.4 Micro Filming by KOC Print Room All registered drawings of various sizes are converted into 35mm microfilms and fixed on aperture cards. This facilitates easy storage and retrieval. 9.4.1 Aperture Card Preparation Im Unperforated 35mm silver salt aperture card counted film with a minimum resolution of 180 lines per mm shall be used unless specified otherwise.The maximum effective aperture of the film shall be 32 x 45 mm. 9.4.2 Reduction Ratio The reduction ratio is given in table below : 'A' SERIES (Trimmed Sizes) REDUCTION RATIO. SHEET | SIZE (mm) SIZE (Inch) AO 841 x 1189 | 33.11 x 46.81 1/30 AL 594 x 841 23.39 x 33.11 4/21 a2 420x594 | 16.54x 23.39 wis Aa 297x420 | 11,69x 16.54 ait Aa 210 x 297 8.27 x 11.69 1/8 THE ABOVE SCALE SHALL BE NON-STANDARD SIZE APPLIED BY TAKING THE WIDTH OF DRAWING AS BASIS Generally, standard drawing sizes AO, Al, A2, A3 and A4 shall be filmed at the rate of one frames as per drawing. 9.4.3. Section Filming Non-standard sized drawings shall be filmed in sections. In this case, the drawing shall be photographed so that each section should have overlap portions and section number as shown in figure below. DIVIDING LINE THESE PORTIONS TO BE itt) SECT. No. FILMED AS OVERLAPS (100mm. ON DWG.) DOC.No.EG-DO-C-001 PAGE 103 OF 109 REV.O 9.4.4 Frame Spacing The frame spacing shall be 50.8 mm with a tolerance of +1.6 mm/-O mm as indicated in figure below. $1.6 50.8 mm 9.4.5 Center Mark, Cutting Mark & Scale Center marks, cutting and scale shall be indicated on the drawing being filmed. The location of the marks and scale shall be shown as below. cutting marks Film edge Card aperture 1 i 4 1 i L 1 rt —— Adhesive film aperture i L i 1 1 i 4 Centre mark Scale LOCATION OF MARKS AND SCALE Notes a. The center marks are to appear on the top and bottom of the finished film. ‘The original thickness of the line shall be 0.5 to 1.0 mm and as short as practicable and should be effective in preventing cuttings errors. b. Cutting marks shall be positioned vertically on the line of cutting. Original thickness of the line should be 3 to 4 mm. and length as practicable within the film aperture. ¢. The scale shall be positioned under the lower left corner of the drawing and shall be 200 mm. in length. DOC.No.EG-DO-C-001 PAGE 104 OF 109 REV.O 9.4.6 Positioning of Drawing Where on film frame, per drawing is to be used, the drawing shall be so positioned that its center corresponds to the center of the aperture. When section filming of non - standard sized drawings, the longitudinal center line of the drawing shall pass through the center of the aperture. a) Lens Resolution Lens resolution shall be 150 lines per mm. at the center and 120 lines per mm. at the periphery. b) Exposure and Developing Density shall be 0.9 to 1.1 fills properly exposed and developed according to standard procedure. The film based on subsequent, must be clear and colourless. ¢) Film Mounting When mounting the film onto the aperture card, the center line of the film and the center line of the aperture must be carefully aligned and tolerance in this case shall be 0.5 mm. d) The Aperture Card The aperture card designed by KOC is shown below. @ NEGATIVE LOCATION e) Contractor Drawing Number Contractor : This is the reference number allocated to the Drawing No. drawing by the contractor. ALL FILLING - IN SHALL BE DONE BY USING CAPITAL LETTERS AND BLACK COLOR. DOC.No.EG-DO-C-001 PAGE 105 OF 109 REV.0 9.5 Revisions Procedure on KOC Drawings a) Make cloud on revised area of the drawing. (4) b) Mark Revision No. Within the Triangle on Revised Areas of the Drawing. (2) ¢) Add Revision No, In REV Column. (3) d) Write the Revision Alphabet and Description. (4) e) Approval Signature & date of Requested Personnel (5) (Engr. or Snr. Engr. Level) ©. DOC.No.EG-DO-C-001 PAGE 106 OF 109 REV.0 10.0 AS-BUILT DRAWINGS 10.1 As Built Drawing Submittal The As Built Drawings with Electronic files shall be submitted by Contractor / PMC to the KOC Controlling Team with covering letter addressed to the "Team leader Design" along with the List of Drawings as shown below. Each Electronic file shall be accompanied by its approved Hard copy. The Hard Copy should be Stamped and Approved by KOC, DRAWING LIST PROJECT TITLE : AREA CONTRACT No. CONTRACTOR NAME CONTRACTOR S.No eNO | SHEETS ELECTRONIC DRAWING TITLE DISCIPLINE FE OTe & NOTE: ALL LETTERS SHALL BE WRITTEN / PRINTED IN BLACK COLOUR DOC.No.EG-DO-C-001 PAGE 107 OF 109 REV.O 10.2 As Built Drawing Approval Stamp AS BUILT KOC APPROVAL DESIGNATION (GROUP / TEAM SIGNATURE t DATE The "As Built Drawing Approval Stamp" shall be shown above the Title Panel and duly signed by KOC Controlling Team Senior Engineer . The Stamp should furnish all the details as shown above. 10.3 As Built Drawing Sheet Sizes The system of International Paper sizes was devised by the International Organization for Standardization (ISO). All contractor drawings size shall be in compliance with KOC drawing sizes as given below. ‘A’ SERIES (Trimmed Sizes) sHeeT | SIZE (mm) | _ SIZE (inch) ao | seixiis9 | 3311x4681 at | soaxeat | 23.39% 33.11 a2_| 420x594 | 16.54x 23.39 as | 297x420 | 11.69x 16.54 a4 | 210x297 8.27 x 11.69 DOC.No.EG-DO-C-001 PAGE 108 OF 109 REV.0 10.4 As Built Drawing Title Panel All contractor drawing shall have the standardized As Built drawing title panel as shown below . Electronic files in Autocad format for AO , Al , A2 & A3 sizes are available in KOC Print/Record Room for Contractor use. Refer Drawing number as mentioned below:- Drg. No. 15-1-74 Sht 1 of 4 (AO Size) Drg. No. 15-1-74 Sht 2 of 4 (Al Size) Drg. No. 15-1-74 Sht 3 of 4 (A2 Size) Drg. No. 15-1-74 Sht 4 of 4 (A3 Size) CONTRACTOR REVISION KOC APPROVALS: Teun ceowrTam | __Awae——*C S| OO KUWAIT OIL CO. agg SI Sa ah AS yay K. S.C. \ pas CONTRACTOR NAME LOGO CONTRACTOR ADDRESS PROJECT TITLE CONTRACT No Saawn [ owe | ARO [DATE|—AREA 7 LOCATION / FACILITY PROJECT TITLE PROJECT TITLE DRAWING TITLE PROI.Ro. DRAWING NUMBER | HHX II OY KX HHH DOC.No.EG-DO-C-001 PAGE 109 OF 109 REV.0 10.5 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) As Built Drawing Specifications Master Drawings Master As-Built Drawings in Original size in Electronic format & Hard Copy Hard Copies Hard copies on Transparent Polyester Film in Original Size from the plotter in specified KOC format . Photocopy in any form is not acceptable. Electronic File Electronic File Names of CAD files shall be same as Drawing Number in Autocad Version in use with KOC on Re-writable CD (Compact Disc) / DVD (Digital Versatile Disc) Common Drawing Common Drawings for different facilities in one project should be numbered as. separate Graphic scale Graphic Scale shall be provided on all scaled Drawings at the right hand side of the drawings above the title panel Key Plan Key Plan with the location plan shall be provided on all Layout Drawings at the right hand side of the drawings above the Graphic Scale. Colour Light colours (like yellow) shall not be used on the drawing Modifications All Modifications carried out during Construction / Installations shall be indicated and detailed. Vendor Drawings Vendor Drawings will not be provided with KOC Drawing number . Vendor Drawings shall be submitted to Controlling Teams only for onward submittal to Technical Library for Records . Print room will not handle Vendor Drawings / Documentation. Specification Drawings deviated from the above Specification shall not be accepted.

You might also like