You are on page 1of 92
Product Catalogue June 2011 Mfr ha Unearthed Contents Corporate Information Introduction ‘About AEL Mining Services Glossary of Abbreviations Lead-times AEL Sales Offices Explosives Surface Bulk Emulsions $8100 Eco Series [Mixed with ANA & sensitised} 58100 Eco Series [Sensitised using ANFO) $8100 Series [Mixed with ANA & sensitised) 58100 Series Sensitsed using ANFO] 5200 Eco Series (Mixed with ANA & sensitised) 5200 Eco Series [Sensitised using ANFO! 50200 Eco Series (Mixed with ANA & sensitised) 56200 Eco Series (Sensitised using ANFO] $1200 Eco Series (Mixed with ANA & sensitised 511200 Eco Series (Sensitised using ANFO] 58300 Series [Mixed with ANA & sensitised) 58300 Series Sensitsed using ANFO] 58300 Eco Series [Mixed wth ANA & sensitised} 58300 Eco Series [Sensitsed using ANFO) Compatibility Matrix Surface Bulk Prod Underground Bulk Emulsions s100 Range Us200 Range Compatibility Matrix Underground Bulk Packaged Explosives Magnum® Watergel explosives Magnum® Buster [Zambia only) Anfex® Specialised Explosives Barret Blasting Gunpowder Compatibility Matrix Packaged & Specialised Ammonium Nitrate Prill Based Explosives Bulk Anfex® Ammonium Nitrate Based Explosives Bulk Antex® Eco Compatibility M Initiating Systems Shock Tube Uni-Delay LP Splitter Mult SPD Muiti LPD Uni-Detay SP Trunkline Cluster Lead-in Extender © AEL Mining Serces Lmtd | Produc Catalogue, 201 2% 2% 2 2% 27 2 28 29 a 32 32 % 35 36 38 a7 38 9 40 a 4“ a Capped Fuse Systems 45 Stopefuse® and Durafuse® 45 Shock Tube Starter 4 AEL Igniter Cords 47 Electronic Delay Detonators 48 QuickShot™ Plus a Smartdet® 0 SmartShat™ 50 Digishot™ 31 DigiShot™ Plus 52 HotShot™ 52 Electric Initiators 54 Statsafe® Detonator 5e Instantaneous Electric Detonator !ED] 55 Fusehead Assembly 56 Shurstart® 37 Shock Tube Starter 88 Electronic Initiators. 59 NetShack™ 59 NetStart™ 60 AEL Initiating Accessories “1 Blast Current Indicator (BCI) ‘t AEL Detonating Cords 82 AEL Pentolite Primers ra AEL Detonating Relays 64 Compatibility Matrix 65 Blasting Accessories 67 Mantis 68 Hot Hole Monitor 69 Industrial Products 70 ‘Ammonium Nitrate Anfo Grade (ANA) nR ‘Ammonium Nitrate Emulsion Grade [ANE) a ‘Ammonium Nitrate Solution (ANS) % Nitric Acid 18 Aquecus Ammonia % ‘Ammonia 100-I, Ammonia 100-R n Services 79 AEL Mining Optimisation 80 Product Services 81 Equipment Services 83 Mobile Manufacturing Units (MMU} Be Mobile Charging Units 85 Portable Charging Units (PCU} 86 Emulsion Plant 101, 207 87 Product New Name Gude ry Introduction Introduction - AEL’s product range and beyond AEL Mining Services is proud to publish our product catalogue showcasing our product offering. Thisis inline with positioning the group as an added value service provider. At AEL, we always aim to go beyond the product offering to bring you a comprehensive range of services to praduce optimum mining productivity, Enhanced customer focus drives us to bring you cutting edge technology and innovations from our R&D team, which playa crucialrole in the developmentoof all our products. Hence youwillnotice the adjustment of product categories and names. This is in line with our strategy to adopt the AEL name as our master brand, with a product or service descriptor designating a category, and likewise, a descriptor designating a specific product or service. So you will find that some of the brand names that you are accustomed to are rebranded with AEL’s name, product or service descriptor and an alpha-numeric code as the specific product. ‘The rebranding of our products has rationalised our product range to ensure that only the best and latest offerings are included. New names are given prominence and old names will appear in smalls after the new names in this edition Alongside the formulation of our products, the new AEL Product Catalogue has been pul together with meticulous care, and we hope that itis an invaluable reference tool for you. With safety at the forefront of our product design focus, on behalf of the AEL management team, | would like to wish youa safe and productive mining environment, Tobie Louw Managing Director @AEL Mining Serves Lmtd | Product Catatogue, 201 About AEL Mining Services Ve (1m AEL Mining Services, a member of the JSE-listed AECI Group in South Africa, is a leading developer, producer and supplier of commercial explosives, initiating systems and blasting services for mining, quarrying and construction markets in Africa and Selected international markets. AEL is the largest supplier of explosives technology and initiating systems in Africa. With its head office in Johannesburg, South Africa, AEL was established in 1896 and has become ane of the world's leading suppliers of explosives and inititaing systems. With 17 companies in AEL Mining Services, the group also has production facilities in offices in South Africa, Egypt, Ghana Mali, Tanzania, Ethiopia, Zambia, DRC, Zimbabwe, Botswana and Indonesia, Using world-class technologies, AEL unearths wealth in the countries in which it operates, providing world-class mining solutions in all key mining, quarrying and construction applications such as open pit, open cast, underground massive, underground narrow reef, dimensional stone and aggregate stone quarrying AEL offers the latest generation products and services for blasting operations, which include electronic detonators, centralised blasting systems, shock tube systems, boosters, detonator cords, capped fuse, igniter cord and blasting accessories, AEL produces and supplies ammonium nitrate and ammonium nitrate solution from its own manufacturing plants. AEL's bulk manufacturing plants provide the group with the capacity to produce and deliver timeously, even when volume demands increases, AEL also supplies a comprehensive range of packaged explosives. AEL deploys in-house engineering competency to design and build Mobile Manufacturing Units {MMUs] for surface and underground mining, bulk emulsion manufacturing plants and modular initiating systems assembly plants. In addition, AEL offers underground mobile and static emulsion pumping systems. AEL deploys blasting services that extract optimum value from any blasting operation with its blend of products, services and solutions. These include Down the Hole, Prime Load Tie and/or Shoot (PLTS], and rock on ground contracting AEL’s Mining Optimisation provides extensive experience in blast monitoring, design, timing, fragmentation analysis, basic blasting principle training, technology conversion, explosive engineering diploma, i-Mining productivity programme and blasting consulting services, Through its modular operations, AEL has the ability to deploy, set up and mobilise infrastructure in remote regions throughout the world in a quick turnaround time, AEL partners, invests and contributes to economies in regions where it operates by meticulously caring for both people and the environment to unearth wealth for current and future generations. © AEL Mining Services Limited | Product bout AEL Glossary of Abbreviations AN ammonium nitrate ANFO ‘ammonium nitrate fuel-oil cN calcium nitrate FO fuel-oil VIXEN-T the AEL international detonating code ED. nstantaneous electric detonator SPD short period delay pp long period delay PETN pentaerythritol tetranitrate RBEE relative bulk effective energy REE relative effective energy TNT trinitrotoluene a ac ing current ADC ‘Ardeer Double Cartridge [test] de direct current RWS: Relative Weight Strength RBS Relative Bulk Strength Kg kilogram a gam gfem™ ‘grampercubiccentimetre kgim______kilogramper metre gim_gramspermetre. SOS kPa kilopascal_———SSS mm milmeter——SOSOS ms millisecond SS m/s metrespersecond SSS mujohm ___milljouleperohm SSS MJ Megajoule SSS NEQ Net explosives Quantity SS sim secondspermatre SSS t_____tonnelmetriel SOS VOD velocityofdetonation SS z mere SSS > greaterthanorequalto SSS « less than x less than or equalto = eas SSS mim____masstomass SSS Spa gigapascal, SCS = approximate pF picoFARAD——SSSOSOS Wee Vatts AEL Sales Offices Lead Times for Standard and Non-Standard Products Definitions Standard products are those products that are carried in stock by AEL based on historic sales out of any individual AEL distribution site, Please contact your local AEL representative to enquire what is, or could be made available, * Non-standard products are either made-to-order or are not standard sales out of a particular AEL distribution site. No stocksare held + Made-to-order products are defined in the product range as those products that AEL would manufacture on receipt ofa confirmed order This category of products is subject to a longer lead-time, but arrangements can be made to carry the product as @ stock item at any AEL distribution site as long as there is a written guarantee that the product will have constant sales ‘of reasonable volume, please contact your local AEL representative for arrangements. Made-to-order products are identified on each of the product pages of the catalogue. Leadtimes Standard products for shafthead deliveries 36hours Iinelese-smetorshatteadceivenescoesnatnclide weekender publi nays) Made-to-order products Va days Standard products by road/railto istomer magazines [ex AEL works) Sdays Exports 20days These tmetort spate felverytimearany weekend Tha sayoforder ney Made-to-order Products and Exports The lead-time for the above two categories is given based on orders that could be large, and the overall demand pattern that has been experienced by AEL's production facilities. The lead-time for each order is open to negotiation depending on the size of any particular order and the overall demand pattern on the plantat any specific pointin tim AEL will endeavor to negotiate in good faith to meet customer requirements but always reserve the right to evoke the lead-time requirementsas stated above, South Africa Nelspruit 0137472278 Johannesburg 0176060000 O'Kiep 0277138597 CapeTown 0218423901 Rustenburg 0145949300 EastLondon 0437452169 Steelpoort0132303201/3 Kimberley 0538611382 Venetia» 0155752395 Klerksdorp 0184771062 Welkom = 0573524073 Mokopane 0154911928 West Wits_-0187883390 Mogalakwena 0154182189 Witbank = 0136901242 Natal 037 2664303 Zomerfeld 0187883390 4 Outside of South Africa Botswana +2673938133 Mauritius +230269 1650 Zambia +260966990945/9 Egypt 420178 661138 Lesotho 427114060505 DRC 424399 5386 257 Tanzania +255282502927 Zimbabwe +263.429 16315 Namibia 26464409453 Indonesia +4221 75924498 Ghana +733302742623 Chile +0056 2 928 1300 AEL Mining Services Lied | Product Catalogue, 201 Explosives “~~ Wealth Unearthed AEL provides a range of explosives in both underground and surface mining. AEL is one of the few key manufacturers of a range of spe vertical up-holes and downholes. AEL's Surface Bulk Explosives are one of the best researched and developed formulations currently in the market. The Eco range of products have been developed to, optimise surface mining blasting, this coupted with the use of recycled oil in the formulation has provided an environmentally friendly range of products that attain higher shock energy, hence providing a unique offering With a solution to suit almost every application environment ~ including surface, underground operations. and quarries - AEL's highly skilled team, its vast range of products and solutions, equipment and technical Fesources have made the company an acknowledged leader in this field, both in South Africa, African regions and internationally One of the company’s ongoing success stories is its Underground Bulk Systems, which, while widely accepted as the industry standard for underground mining, is continuously evolving within the walls of AEL's Research & Development department. New and improved emulsion formulations, pumping systems and value-add services, targeted to this industry are constantly being realised as AEL continues inits efforts toimprove its offering, The Underground Bulk System technology and AEL's initiating systems combine to optimise safety while improving blasting efficiencies in a variety of mining, tunnelling and shaft sinking applications. Even under the lly formulated products that can be effectively placed in most trying blasting conditions, AEL’s proven technologies, deliver tangible benefits to its customers across the entire mining operation. Most notably, through the application of innovative technology combined with years of experience in this market, AEL has introduced its “sticky” solution, which offers customers a competitive edge in cost effective blasting and is set to change the blasting landscape as we know it today. Offering customers the ability to place explosives vertically up-hole has changed the way customers view difficult blasting environments and simplified the process substantially. Through its strategically placed network of regional depots, AEL is able to provide a full range of explosives and services to the most remote customers in African and international markets. This includes a wide range of specifically formulated water gels, emulsions, dry gels and ANFEX solutions. As with all AEL products, these solutions are supported by a reliable range of initiation systems and blasting services, as well as skilled technical support staff who are on hand tomanage customerneeds ‘J Wining Services Surface Bulk Emulsions - SB100 Eco Series (Mixed with ANA and Sensitised) ‘Sb100 Eco is an AN only base emulsion matrix. It is environmentally friendly as waste or recycled ol is used in the oil phase, It is handled ané transported as an unsensitizes product ta mines and/or operational sites. The product is charged in blast holes when sensitised (S100 Eco) or blended with ANA and sensitised or with Anfo mixed to various ratios. \tis used in surface mining blasting. I's water resistance is ecxellent depending on emulsion JAnio ratio. Once blended and/or sensitised, the S100 Eco product range has a Velocity of Detonation (VOD) between 4,500 & 6000s Technical Specifications ‘Appearance SB100 Eco series are dark grey or black emulsion blend products. Benefits and Features Benefits (SB100 Eco series) + Environmentally friendly + Safe to handle + Easy to handle On the bench manufacturing ‘+ Choice of any blend ratio on the bench Features « Incorporates waste ol in the oil phase + S100 Eco is a non-detonable emulsion blend before -sensitising, only becoming an explosive once sensitised [$100 Eco Series) Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties Sleep Time 10 days Colour Dark grey/black Velocity of Detonation 4 500-6000m/s Water resistance Excellent Minimum initiator 150gm Booster Recommendations for use + SB100 Eco should be sensitised [S100 Eco Series] as required on the bench using AEL Mining Services recommended equipment before charging into blast holes ‘Special precautions = Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 6 Mining Method Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $100 Eco Product Series Mixed with ANA and Sensitised - This is sensitised $8100 Eco ‘and is offered in the range indicated in the table below. Proper 35100 Feo sian Ec [56195 Feo Mirisunvae 5 co siameter (mm? Water eastanca Tacaient | Cecstent [Eaten [Beaten rypetin-hate 1B | 18 | 1 | 1S erst ler Senster Taasng | Casey | Gang | Canny seiton | solution | solution | solution Horas eT Ta a [| Primer Booster | Boosior | Boost | Booster oowPs RWS RANFOF [9 io i]t owes RBS [KANFOE_[ sey | 1758 2oMPa RWS [eANEOR [65 #3 [97 [100 oNpa RBS IWANFOR | —¥s5[ ws [182] 186 Notes: {Lln-hole densities of emulsions vary with depths. Please contact your regional sales office for assistance in finding the best product fit or your application 2.The Relative Weight & Bulk Strengths are relative to ANFO (=100] at a density of 0,80 g/cm. The figures have been determined using the VIXEN: detonation code. 3.The availabilty ofthe above offering is subject to MMU configuration ‘In large diameter, typicaly 250 mm and above, a maximum of 3m of water may be allowed, 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [100] at a density of 0,80 gfem3. The figures have been determined using the VIXEN-i detonation code. Storage and Expiry ‘$8100 Eco has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities, Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No, 3375, AMMONIUM NITRATE EMULSION © AEL Maing Serves Lmtd | Produc Catague, 211 Surface Bulk Emulsions - SB100 Eco Series (sensitised using Anfo) 'Sb100 Eco is an AN only base emulsion matrix. It is environmentally friendly as waste or recycled ol is used in the ol phase. It is handled and transported as an unsensitized product to mines and/or operational sites. The product is charged into blast holes when sensitised ($100 Eco] or blended with ANA and sensitised or with Anfo mixed to various ratios It is used in surface mining blasting, Its’ water resistance is variable depending on emulsion JAnio ratio. Once blended andlor sensitised, the S100 Eco product range has a Velocity of Detonation (VOD) between 4,500 & 6000 ms. Technical Specifications Appearance $8100 Eco series are a dark grey or black emulsion blend product. Benefits and Features Benefits (SB100 ECO series) + Environmentally friendly * Safe to handle «+ Easy to handle ‘On the bench manufacturing Choice of any blend ratio on the bench Features * Incorporates waste ol in the oil phase + $100 Eco is a non-detonable emulsion blend before ssensitising, only becoming an explosive once sensitised [S100 Eco Series) + Charged using a pump or an augered depending on the ANA/Emulsion ratio “Mixed with ANA ar Anfo in various ratios depending on energy requirement Technical Properties Sleep Time 10 days Colour Dark grey/black Velocity of Detonation 4 500-6000m/s Water resistance Variable Minimum initiator 750gm Booster Mining Method Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $100 Product Series Sensitised Using Anfo - This is sensitiseé SB100 Eco and is offered? in the range and indicated in the table below. Prowerty [SBTSUE Co] S6TSTECo| SB 160E co] SB TaNECATSS TURE Ninury ove 20] 200 | 10 | 150 | 150 diameter Imm) ster resistance Table | Variable | Variable | Variable [Varabl Typical in-hole a density afer’) Senstiser Tafa_[Aafe [Ante | Anfe [Ane REST Fe a deptns™ (gem Peers Booster | Booster | Bossier | Booster [Baoan ToOMPARWS TNFR 125 [iz fue sy | sw. WWOMpa RBS teawecr | 120 [198 | tee [176 tue ZowPs RWS rawr [197 [198 [105 [0s 1 2oMpa RAS uanror [tao | 172 | tga [159 | 130 Notes: in-hole densities of emulsions vary with depths. Please contact your regional sales ofice for assistance in fnging the best product ft for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [+1001 at a density of 0.80 gms. The figures have been determined using the VIKEN-| detonation code '3.The availability of the above offering is subject to MMU configuration. “k.inarge giameter, typically 250 mm and above, a maximum of 3m of water ray be allowed 5 The Relative Bulk Strengths and fective Energies are relative to ANFO (100) at @ density of 0.80 g/cm. The figures have been determined using the VIREN-s detonation code Storage and Expiry ‘SB100 Eco has a shel life of 3 months Recommendations for use + §B100 Eco should be sensitised (S100 Eco Series] as, required on the bench using AEL Mining Services recommended equipment before charging into blast holes: Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised © AEL Mining Services Limited | Product Catalogue, 2211 Silos and Isotainers are the recommended storage facililies Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do nat transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION Surface Bulk Emulsions - SB100 Series (mixed with ANA and Sensitisea) ‘Sb100 is an AN only base emulsion matrix. It is handled and transported as an unsensitized Product to mines and/or operational sites. The product is charged into blast holes when sensitised (S100] or blended with ANA and sensitised or with Anfo mixed to various ratios, [S100 Series as outlined in the table below. It is used in surface mining blasting. Its’ water resistance is excellent depending on emulsion Ano ratio. Once blended andor sensitised, the S100 product range has a Velocity of Detonation (VOD) between 4,500 & 6000 m/s. Appearance 5B100 series are a honey coloured blend products. Benefits and Features Benefits «Safe to handle + Easy to handle On the bench manufacturing + Choice of any blend ratio on the bench Features + SB100 is a non-detonable emulsion blend before ‘sensitising, only becoming an explosive once sensitised (S100 Series) + Charged using a pump or an augered depending on the ANA/Emulsion ratio “= Mixed with ANA ar Anfo in various ratios depending on energy requirement Technical Properties Sleep Time 10 days Colour Honey coloured Velocity of Detonation 4 500-6000m/s Water resistance Excellent Minimum initiator 750gm Booster Recommendations for use + 5B100 should be sensitised (S100 Series) as required on the bench using AEL. Mining Services recommended equipment before charging into blast holes ‘Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised Mining Method Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $100 Product Series Mixed with ANA and Sensitised - This is sensitised SB100 and is offered in the range indicated in the table below. Proverty ‘$8100 Eco [ $8120 Evo [50190 Eeo [e195 Eee inmnar pate 5 75 io | 100 siameter (oe [water resistance Eicelent | Becelent [Excellent | Beeelent Pypicatin-nole 125 1 1 | 12 density Ife) anor Taseng | Gassing | Cassa | Sassng solution | solution | solution | solution Rise nole depo TaD a0 20 0 o Pemer Booster | Booster | Booster | Booster oss RWS [RANEOE i i i nompa RBS (sANFO | 17 | i777 powPs RWS IaNFOF [5 8 97 100 zovpa RAS (%ANFOP [139 a Notes “in-hole densities of emulsions vary with depths. Please contact your regional sales office for assistance in finding the best produc fit for your application. 2.The Relative Weight & Bulk Strengchs are relative to ANFO [100] ata density (1 0,80 g/em3, The figures have been determined using the VIKEN i detonation code, 43 The availability of the above offering is subject to MMU configuration. “Ainlargeaiameter, typically 250 mmm and above, a maximum of 3m of water ‘may be allowed 5 The Relative Bulk Strengths and Effective Energies are relative to ANEO (100) at a density of 080 g/ema. The figures have been determined using the \IKEN-i detonation code, Storage and Expiry SB100 has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION © AEL Mining Services Lined | Product Catatgue, 2011 Surface Bulk Emulsions - SB100 Series (sensitised using Anfo) Sb100 Eco is an AN only base emulsion matrix. It is environmentally friendly as waste or recycled fuel is used in the ol phase. It is handled and transported as an unsensitized product ta mines and/or operational sites. The product is charged in blast holes when sensitised ($100 Ecol or blended with ANA and sensitised or with Anfo mixed to various ratios It is used in surface mining blasting. Its’ water resistance is variable depending fon emulsion/Anfo ratio. Once blended and/or sensitised, the S100 Eco product range has Velocity of Detonation (VODI between 4,500 & 6000 m/s, Appearance 58100 series are @ honey coloured emulsion blend products. Benefits and Features Benefits (SB100 s + Safe to handle + Easy to handle On the bench manufacturing * Choice of any blend ratio an the bench Features + SB100 is a non-detonable emulsion blend before ssensitising, only becoming an explosive once sensitised ($100 Series) * Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on energy requirement Technical Properties Sleep Time 10 days Colour Honey coloured Velocity of Detonation 4 500-6000m/s Variable TS0gm Booster Recommendations for use + 5B100 Eco should be sensitised (S100 Eco Series] as required on the bench using AEL Mining Services recommended equipment before charging into blast holes: ‘Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised © AEL Mining Services Limited | Product Catalogue, 2211 Mining Method Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $100 Product Series Sensitised Using Anfo - Ths is sensitised SB100 and is offered in the range indicated in the table below Proper [SBTGU co] SHTOTEco| SH 160r co] SB TanPeeS TURE Jaina note a laiameter Imm [Water resistance rr Hi ia | Variable [Variable fivpicain-hoie a \density afer) ISersiiser Bava [ Anja [Ante | Anie [Ane em Fale laepths™ Ife [primer= Booster | Booster | Booster | Booster [Banster foowPaRwemanror[ 1s [ia | ie P17 | so ootpa ABS teanror [120 | rae | 18696 | nae MPa RWS twantos [107 {toe 1005 | ns 1 Ieompa RBS tuawrow [veo [172 | 16 | 157 [134 Notes in-hole densities of emulsions vary with depths, Please contact your regional sales office for assistance in finding the best product ft for your anpication 2.The Relative Weight & Bulk Strengths are relative to ANEO [+160] at density of 0,80 em. The figures have boon determined using the VIXEN: detonation code '3.The availabilty of the above offering is subject to WM configuration. ‘in large ciameter, typically 250 mr and above, a maximum of 3m of water ‘may be allowed 5.The Relative Buk Strengths and Elfective Energies are relative to ANEO (100) at a density f 0.80 g/em3. The figures have been determined using ‘he VIEN-i detonation cod, Storage and Expiry ‘SB100 has a shel life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No, 3375, AMMONIUM NITRATE EMULSION Surface Bulk Emulsions - SP200 Eco Series (Mixed with ANA and Sensitisea) 'SP200 Ecoisan AN and CN based emulsion matrix specially formulated for hardrock blasting, It is environmentally friendly as waste or recycled fuel is used in the ol phase. It is handled and transported as an unsensitized product to mines and/or operational sites. The product is charged in blast holes when sensitised [SP200 Ecol or blended with ANA and sensitised or with nfo mixed to various ratios [SP200 Eco Series] as outlined in the table below. It is used in surface mining blasting. Its’ water resistance is excellent depending on emulsion/ANA ratio. Once blended and/or sensitised, the SP200 Eco product range has a Velocity of Detonation | Mining Method (VoD of between 4500m/sand 6000 m/s, Technical Specifications ‘Appearance P20 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits + Environmentally friendly * Safe to handle + Easy to handle + On the bench manufacturing ‘Choice of any blend ratio on the bench Features + Incorporates waste oil in the oil phase + SP200 Eco is # non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised ‘Charged using a pump or an augered depending on the ANA/Emulsion ratio “Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties ‘Sleep Tim: weeks Colour Dark grey / black Velocity of Detonation 4500m/s - 6000m/s Water resistance Excellent Minimum initiator 150gm Booster Recommendations for use SP200 Eco should be sensitised as required on the bench Using AEL Mining Services recommended equipment before charging into blast holes ‘Special precautions Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 10 Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $200 Product Series Mixed with ANA and Sensitised frroser ‘52700 Eco [5P220 Eco [3730 bea] S235 Eco Iainimurs pate 7% Ts To] 100 liameter (om)? ater resistance Eicelient | Excellent [Excelent | Excellent iypieain-nole Ts | 1s] 1 | 1s fensity infer Bensitser Dany | ORIG] Casey | ORT solution | souution_| solution | solution [Pomer Booster | Sooster | Sooster | Booster [toons RWS TeANFOR | 7 a Lc [t0dspa RBS eaNeO | i 770 MPa RWS [ANI a2 1 9% 96 foe RAS (ANFO! ref at] ar 150 Notes: ‘LIn-hole densities of emulsions vary with depths. Please contact your regional sales offce for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty ofthe above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3m of water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/em3, The figures have been, determined using the VIXEN-i detonation code Storage and Expiry SP200 Eco has a shelf life of 3 months ‘Silos and Isotainers are the recommended storage facilities — ‘Storage sitesmustbesecure SSS ‘Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION © AEL Mining Services Lined | Product Catatgue, 2011 Surface Bulk Emulsions - SP200 Eco Series (sensitised using Anfo) 'SP200 Ecoisan AN and CN based emulsion matrix specially formulated for hard rock blasting. is environmentally friendly as waste or recycled fuel is used in the ol phase. It is handled and transported as an unsensitized product to mines and/or operational sites. The product is charged in blast holes when sensitised [SP200 Ecol or blended with ANA and sensitised or with nfo mixed to various ratios [SP200 Eco Series] as outlined in the table below. It is used in surface mining blasting. Its’ water resistance is variable depending on temulsion/Anfo ratio. Once blended and/or sensitised, the SP200 Eco product range has a Velocity of Detonation | Mining Method (VoD of between 4500m/sand 6000 m/s, Technical Specifications ‘Appearance P20 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits + Environmentally friendly * Safe to handle + Easy to handle + On the bench manufacturing ‘Choice of any blend ratio on the bench Features + Incorporates waste oil in the oil phase + SP200 Eco is # non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised ‘Charged using a pump or an augered depending on the ANA/Emulsion ratio “Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties ‘Sleep Tim: weeks Colour Dark grey / black Velocity of Detonation 4500m/s - 6000m/s Water resistance Variable Minimum initiator 150gm Booster Recommendations for use SP200 Eco should be sensitised as required on the bench Using AEL Mining Services recommended equipment before charging into blast holes ‘Special precautions Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised © AEL Mining Services Limited | Product Catalogue, 2211 Surface Opencast Open Pit Quarrying Application Open Pit Quarrying $200 Product Series Sensitised Using Anfo frroser [sh2s4 Eco] $6287 Eco] sP260 Bea] SPz6e Bea] sh274 Eco Wainmumpowe | 250} za 150] 150} 150, liameter (om)? ater resistance] Variable | variabie | Variable | Variable | variable iypieatin-nole | 735 J 13} 2 | 12] 105 fensity infer rman Basar | Booster | Bowater | Booster | Booster [oma RWS [173-17 7 TT TH [o0btpa RES 7 T 7: | Ps RWS 0 aL: 10 3} 0 Povo Ras T TOT 7 13 Notes: ‘LIn-hole densities of emulsions vary with depths, Please contact your regional sales office for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty of the above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3mm lof water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/cm3, The figures have been determined using the VIXEN-i detonation code. Storage and Expiry ‘SP200 Eco has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION " Surface Bulk Emulsions - SC200 Eco Series (Mixed with ANA and Sensitisea) ‘$0200 Eco is an AN and CN based emulsion matrix specially formulated to maximising the recycled oll content - Itis environmentally friendly as the waste or recycled fuel is used in the oil phase. It is handled and transported as an unsensitized product to mines and/or ‘operational sites. The product is charged in blast holes when sensitised (SC200 Ecol or blended with ANA and sensitised or with Anfo mixed to various ratios (SC200 Eco Series] as outlinedin the table below. Itis used in surface mining blasting, Its’ water resistance is excellent depending on emulsion/ANA ratio. Once blended and/or sensitised, the SC200 Eco product range has a Velocity of Detonation [VOD] of between 4,200 m/s Mining Method Surface Opencast Open Pit and5700 m/s. Technical Specifications ‘Appearance C200 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits + Environmentally friendly * Safe to handle + Easy to handle + On the bench manufacturing ‘Choice of any blend ratio on the bench Features + Incorporates waste oil in the oil phase + SC200 Eco is @ non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised ‘Charged using a pump or an augered depending on the ANA/Emulsion ratio “Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties ‘Sleep Tim: weeks Colour Dark grey / black Velocity of Detonation 4200m/s - 5700m/s Water resistance Excellent Minimum initiator 150gm Booster Recommendations for use SC200 Eco should be sensitised as required on the bench Using AEL Mining Services recommended equipment before charging into blast holes ‘Special precautions Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 2 Quarrying Application Open Pit Quarrying $200 Product Series Mixed with ANA and Sensitised frroser $5020 co [50220 Eco [30730 Ee] $0235 Eco Iainimurs pate 7% Ts To] 100 liameter (om)? ater resistance Excellent | Excellent [Excelent | Excellent iypieain-nole Ts | 1s] 1 | 1s fensity infer Bensitser Casas | Gassing] Cassy | Casas solution | soistion | solution | solution [Pomer Booster | Booster | Sooster | Booster [rooms RWS TRANFOR | 3 Tas % [t00spa RBS HeaNeO | 19 Tr Ts 770 MPa RWS [ANI 7 7 a 36 foe RAS (ANFO! yo [tae tat 112 Notes: ‘LIn-hole densities of emulsions vary with depths. Please contact your regional sales offce for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty ofthe above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3m of water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/em3, The figures have been, determined using the VIXEN-i detonation code Storage and Expiry SC200 Eco has.a shelf life of 3 months ‘Silos and Isotainers are the recommended storage facilities — ‘Storage sitesmustbesecure SSS ‘Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION © AEL Mining Services Lined | Product Catatgue, 2011 Surface Bulk Emulsions - SC200 Eco Series (sensitised using Anfo) ‘$0200 Eco is an AN and CN based emulsion matrix specially formulated to maximising the recycled oll content - Itis environmentally friendly as the waste or recycled fuel is used in the oil phase. It is handled and transported as an unsensitized product to mines and/or ‘operational sites. The product is charged in blast holes when sensitised (SC200 Ecol or blended with ANA and sensitised or with Anfo mixed to various ratios (SC200 Eco Series] as outlined in the table below. Itis used in surface mining blasting. Its’ water resistance is variable depending on emulsion/Anfo ratio. Once blended and/or sensitised, the SC200 Eco product range has a Velocity of Detonation [VOD] of between 4,200 m/s Mining Method Surface Opencast and5700 m/s. Technical Specifications ‘Appearance C200 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits + Environmentally friendly * Safe to handle + Easy to handle + On the bench manufacturing ‘Choice of any blend ratio on the bench Features + Incorporates waste oil in the oil phase + SC200 Eco is @ non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised ‘Charged using a pump or an augered depending on the ANA/Emulsion ratio “Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties ‘Sleep Tim: weeks Colour Dark grey / black Velocity of Detonation 4200m/s - 5700m/s Water resistance Variable Minimum initiator 150gm Booster Recommendations for use SC200 Eco should be sensitised as required on the bench Using AEL Mining Services recommended equipment before charging into blast holes ‘Special precautions Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised © AEL Mining Services Limited | Product Catalogue, 2211 Open Pit Quarrying Application Open Pit Quarrying $200 Product Series Sensitised Using Anfo frroser [Sc254 Eco] $6287 Exe] 0260 kea] sozs4 tea] so774 Eco Wainmumpowe ] 250} za Te0 | 150} 150, liameter (om)? ater resistance] _Varable | variabie | Variable | Variable | variable iyicatin-note | 135 J 13} 12] 12 105 fensity infer rman Tosser | Booster | Booster | Booster | Bossier [roonPa RWS —[—_T7 7 7 T_T [o0btpa RES m9 ae Ps RWS a RL a 0: Tr Povo Ras TI 16] 7 Ta Notes: ‘LIn-hole densities of emulsions vary with depths, Please contact your regional sales office for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty of the above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3mm lof water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/cm3, The figures have been determined using the VIXEN-i detonation code. Storage and Expiry SC200 Eco has.a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION 13 Surface Bulk Emulsions - SH200 Eco Series (mixed with ANA and Sensitises) ‘SH200 Eco is an AN, CN and Urea based product specially formulated for blasting in area with Hot Bore Holes. itis environmentally friendly as waste or recycled fuelis usediinthe oll phase. It is handled and transported as an unsensitized product to mines and/or ‘operational sites. The product is charged in blast holes when sensitised [SH200 Ecol or blended with ANA and sensitised or with Anfo mixed to various ratios [SH200 Eco Series] as outlined n the table below. tisused in surface mining blasting. Its’ water resistance is excellent depending on ‘emulsion/ANA ratio. Once blended and/or sensitised, the ‘SH200 Eco product range has a Velocity of Detonation Mining Method Surface Opencast [VOD] of between 4,000 m/s and 500 m/s. Technical Specifications Appearance SH200 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits ‘Enable hot bore hole blasting up to 280°C + Environmentally friendly + Safe to handle + Easy to handle ‘On the bench manufacturing ‘Choice of any blend ratio an the bench Features + Incorporates waste ol in the oil phase + SH200 Eco is a non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties Sleep Time Not recommended [safety] Colour Dark grey / black Velocity of Detonation 4000m/s - 5500m/s Water resistance Excellent Minimum initiator 150gm Booster Recommendations for use SH200 Eco should be sensitised as required on the bench using AEL Mining Services recommended equipment before charging into blast holes Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 1% Open Pit Quarrying Application Open Pit Quarrying $200 Product Series Mixed with ANA and Sensitised frroser ‘5200 Eco |[5H220 Eco [53230 Eo] SH7a8 Eco Iainimurs pate % % 00} 100 liameter (om)? ater resistance Tacelient | Excelent | Excelent | Prcelient iypieain-nole Ts | 1s] 125 | 1s fensity infer Bensitser Cag | Cag] Caseig | CoG solution | solution | soiution | solution [Pomer Booster | Booster | Booster | Booster [toons RWS TEANFOR | 33 Tar fa [t00spa RBS CeaNeO | TH To 1 MPa RWS [ANI 75 7 89 ca foe RAS (ANFO! tis [ tz 1390 Notes: ‘LIn-hole densities of emulsions vary with depths. Please contact your regional sales offce for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty ofthe above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3m of water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/em3, The figures have been, determined using the VIXEN-i detonation code Storage and Expiry SH200 Eco has a shelf life of 3 months ‘Silos and Isotainers are the recommended storage facilities — ‘Storage sitesmustbesecure SSS ‘Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION © AEL Mining Services Lined | Product Catatgue, 2011 Surface Bulk Emulsions - SH200 Eco Series (sensitised using Anfo) ‘SH200 Eco is an AN, CN and Urea based product specially formulated for blasting in area with Hot Bore Holes. itis environmentally friendly as waste or recycled fuelis usediin the oll phase. It is handled and transported as an unsensitised product to mines and/or ‘operational sites. The product is charged in blast holes when sensitised [SH200 Ecol or blended with ANA and sensitised or with Anfo mixed to various ratios [SH200 Eco Series] as outlined n the table below. tisused in surface mining blasting. Its’ water resistance is variable depending on ‘emulsion/Anfo ratio, Once blended and/or sensitised, the SH200 Eco product range has Velocity of Detonation, Mining Method Surface Opencast [VOD] of between 4,000 m/s and 500 m/s. Technical Specifications Appearance SH200 Eco products are a dark grey or black emulsion blend product Benefits and Features Benefits ‘Enable hot bore hole blasting up to 280°C + Environmentally friendly + Safe to handle + Easy to handle ‘On the bench manufacturing ‘Choice of any blend ratio an the bench Features + Incorporates waste ol in the oil phase + SH200 Eco is a non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties Sleep Time Not recommended [safety] Colour Dark grey / black Velocity of Detonation 4000m/s - 5500m/s Water resistance Variable Minimum initiator 150gm Booster Recommendations for use SH200 Eco should be sensitised as required on the bench using AEL Mining Services recommended equipment before charging into blast holes Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised CAEL Mining Serces Lites | Product Catalogue, 2011 Open Pit Quarrying Application Open Pit Quarrying $200 Product Series Sensitised Using Anfo frroser [5H254 Eco|sH257 Ece|shz60 Eee] su264 Eco] SH774 Eco Winmompowe ] 250} za | 160] 150} 150 liameter (om)? ater resistance] _Varable | variabie | Variable | Variable | variable iyicatin-note | 135 J 13} 12] 12 105 fensity infer Tamar Tassie | Booster | woastar | woaster | Wooster oomramws [ne Pn fis [is [107 hroompa res [701 two [179 | 170 [1a loowPs aws a Pompe ROS 17a _| 1665] ef 82 a Notes: ‘LIn-hole densities of emulsions vary with depths, Please contact your regional sales office for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/em3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty of the above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3mm lof water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 g/cm3, The figures have been determined using the VIXEN-i detonation code. Storage and Expiry SH200 Eco has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification] Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION 15 Surface Bulk Emulsions - SB300 Series (Mixed with ANA and Sensitisea) ‘SB 300 is an AN and Urea formulation base emulsion matrix. Its recommended for = Use in reactive grounds mostly in coal mining. Its handled and transported as an Lnsensitized product to mines and/or operational sites. The product is charged in blast holes when sensitised (S300) or blended with ANA and sensitised or with Anfo mixed to various ratios (5300 Series) as outlined in the table below. Itis used in surface mining blasting. Its' water resistance is excellent depending on emulsion/ANA ratio. Once blended and/or sensitised, the $300 product range has a Velocity of Detonation [VOD] between 4,500 & 5,500 m/s, Appearance 58300 series are a honey caloured emulsion blend products. Benefits and Features Benefits * Can be used in reactive ores or grounds, + Safe to handle + Easy to handle On the bench manufacturing ‘Choice of any blend ratio an the bench Features + Contains Urea in formulation + $8300 is non-detonable emulsion blend before sensitising,, only becoming an explosive once sensitised [S300 Series) + Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on ‘energy requirement Technical Properties Sleep Time Not recommended Velocity of Detonation 4 500-5 500m/s Water resistance Excellont Minimum initiator 180gm Booster Recommendations for use + 58300 should be sensitised (S300 Series) as required on the bench using AEL. Mining Services recommended equipment before charging into blast holes ‘Special precautions ‘+ Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 6 Mining Method Surface Opencast Open Pit Quarrying Application Open Pit $300 Product Series Mixed with ANA and Sensitised Proper sso eee | sss5eco [5950 Fco Miirmars nove % Too TO siameter (mm) [Water resistance Tieotent | Beetent | excelent Typical in-hole 1 75 12 density fem Sensivee oy Gassng —] Gass solution | solution _| solution Maxhole dept & & 30 Primer Booster Booster | Booster OM Pa RWS (EANFOT 35 Ts 70 hod RBS (%ANFO 130 16 761 ZOMPs RWS [ANFO 3 8 Tas 20Mp@ RBS (ANFO TF 155 767 Notes: ‘LIn-hole densities of emulsions vary with depths. Please contact your regional sales office for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [+100] ata density of 0,80 g/em3. The figures have been determined using the VIXEN- detonation code. 43.The availabilty of the above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3 m of water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to [ANFO [=100) at a density of 0,80 g/cm3. The figures have been determined using the VIXEN-i detonation cade. Storage and Expiry ‘$8300 has a shelt life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and detonators shouldn't be allowed in storage sites, Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION AEL Ming Services Lmtd | Product Catlgue, 2011 Surface Bulk Emulsions - SB300 Series (sensitised using Anfo) $$b200 is an AN and Urea formulation base emulsion matrix. It is recommended for Use in reactive grounds mostly in coal mining, It is handled and transported as an unsensitized product to mines and/or operationel sites. The product is charged in blast holes when sensitised (S300) or blended with ANA and sensitised or with Anfo mixed to various ratios (S300 Series) as outtined in the table betow. 5,500 mis, Appearance 58300 series are a honey coloured emulsion blend product. Benefits and Features Benefits Can be used in reactive ores or grounds + Safe to handle «Easy to handle On the bench manufacturing ‘+ Choice of any blend ratio on the bench Features ‘Contains Urea in formulation ‘= 58300 is non-detonable emulsion blend before sensit'sing,, ‘only becoming an explosive ance sensitised (S300 Series) + Charged using a pump or an augered depending on the ANA/Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on energy requirement Technical Properties Not recommended 4 500-5 500m/s Variable 509m Booster Minimum initiator Recommendations for use + 58300 should be sensitised (S300 Series) as required on the bench using AEL Mining Services recommended equipment before charging into blast holes © AEL Mining Services Limited | Product Catalogue, 2211 Itis used in surface mining blasting. Its’ water resistance is variable depending on emulsion/Anfo ratio, Once blended and/or sensitised, the S300 product range has a Velocity of Detonation [VOD] between 4,500 & Mining Method Surface Opencast Open Pit Quarrying Application Open Pit 5300 Product Series Sensitised Using Anfo Property [ssi Fes [ss57 Geo [ssn eco [sasatco far Fco Minimarsfote— 50 | 200] tsa | 180 | 150 diameter (em) [Water resistance [Venable | Varabie [Variable [Variable [Venable v2 ize] 125 | 120] 105 density afer’ Sensiise “nis | Anis | anf | Ania | nis Reem, Hole ra ra 30 80 30 depen Primer Booster | Baasier | Booster | Baosiar [Booster foomPaRWS Poe] 10] ia | i] ie I6ANFOI fioompares [9p 192 | 19 | 96 | 202 .ANEOI 20s RWS woe [105 | ts aor [at eANEOI 20M RES w | we pw | me | im s6aNFor Special precautions * Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised Storage and Expiry 98300 has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No, 3375, AMMONIUM NITRATE EMULSION "7 Surface Bulk Emulsions - SB300 Eco Series (Mixed with ANA and sensitised) ‘$8900 Ecois an AN and Urea formulation base emulsion matrix. tis recommended for use in reactive ground mostly in coal mining. It is handled and transported as an unsensitized product to mines and/or operational sites. The product is charged into blast holes when sensitised (S300 Eco] or blended with ANA and sensitised as outlinedin the table below. Itis used in surface mining blasting Its’ water resistance is ‘emulsion/Anfo ratio. Once blended and/or sensitised, the $300 Eco product range has a Velocity of Detonation {VOD} ranges from 4,500m/s to 6,000m/s, Technical Specifications Appearance SB300 Eco products are a dark grey or black emulsion blend product. Benefits and Features Benefits Can be used in reactive ores or grounds ‘+ Environmentally friendly - Contains waste or recycled oil + Safe to handle + Easy to handle On the bench manufacturing Choice of any blend ratio on the bench Features ‘Contains Urea in formulation + $8300 Eco is non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised [$300 Eco Series) “Charged using a pump or an augered depending on the ANA ‘and Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on energy requirement Technical Properties Sleep Time Not recommended (safety) Velocity of Detonation 4500m/s = 6000m/s Waterceitenee om Recommendations for use 58300 Eco should be sensitised [S300 Eco Series) as, required on the bench using AEL Mining Services recommended equipment before charging into blast holes Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised 18 Mining Method Surface Opencast Open Pit exellent depending on Quarrying Application Open Pit ‘300 Eco Product Series Mixed with ANA and sensitised Property $8384 Eco] $8367 Ecx|st360 Eco] S8364 Eco] $8374 Eco Winimarsnate] 250} za | 150 | 150} 150, liameter (mm ater resistance] Varable | Variable | Variable | Varable | variable iypeatin-note | 128 | 128 | zs | 12 | too feensity afer nee Ig | “ae | “es | Recm hole “5 “50 30 30 fepths i Timer Booster | Booster | Wooster | Soester | Bossier foomPaRWS 117} ta Par] aa} 8 (eANEOE fivompa ROS | 190 [—T9—| 190} 198707 Issanror Pama RWs Ta | 0 [WANFO! Bovtoa Ras a a lssanror Notes: “UIn-hole densities of emulsions vary with depths. Please contact your regional sales office for assistance in finding the best product fitfor your aplication 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] ‘at a density of 0,80 glem3. The figures have been determined using the VIKEN-i detonation code. 3.The availabilty ofthe above offering is subject to MMU configuration. {in large diameter, typically 250 mm and above, @ maximum of 3m cof water may be allowed 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO (=100] at a density of 0,80 g/cm3, The figures have been determined using the VIXEN-i detonation code. Storage and Expiry $B300 Eco has a shelf life of 3 months ‘Silos and Isotainers are the recommended storage facilities — Siorage sites mustbesecure SS ‘Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION ‘©AELMing Serves Lmtd | Produc Catague, 211 Surface Bulk Emulsions - SB300 Eco Series (Mixed with Anfo) ‘$8900 Ecois an AN and Urea formulation base emulsion matrix. tis recommended for use in reactive ground mostly in coal mining. It is handled and transported as an unsensitized product to mines and/or operational sites. The product is charged into blast holes when sensitised [S300 Eco] or blended with Anfo as outlined inthe table below. Itis usedin surface mining blasting. Its! water resistance is variable depending on ‘emulsion/Anfo ratio. Once blended and/or sensitised, the $300 Eco product range has a Velocity of Detonation (VOD) ranges from 4,500m/s to 6,000m/s Technical Specifications ‘Appearance 58300 Eco products are dark grey or black emulsion blend product Benefits and Features Benefits Can be used in reactive ores or grounds ‘+ Environmentally friendly - Contains waste or recycled oil + Safe to handle + Easy to handle ‘On the bench manufacturing ‘Choice of any blend ratio an the bench Features ‘Contains Urea in formulation + $8300 Eco is non-detonable emulsion blend before sensitising, only becoming an explosive once sensitised [$300 Eco Series) Charged using a pump or an augered depending on the ANA and Emulsion ratio ‘+ Mixed with ANA or Anfo in various ratios depending on energy requirement Technical Properties Sleep Time Not recommended (safety) Water resistance Excellent Minimum initiator 150gm Booster Recommendations for use 58300 Eco should be sensitised [S300 Eco Series) as, required on the bench using AEL Mining Services recommended equipment before charging into blast holes Special precautions + Once sensitised base emulsion becomes an explosive + Storage not recommended once sensitised CAEL Mining Serces Lites | Product Catalogue, 2011 Mining Method Surface Opencast Open Pit Quarrying Application Open Pit $300 Product Series Mixed with Anfo frroser ssovtes [saasecs [s380 co Iainimurs pate 7 700 100 liameter (om)? ater resistance Excalient | excelent | Excelent iypieain-nole 12 125 125 fensity afem' Bensitser ee ax hoe pA TAT m7 ramen aos aos Teaser [Toons RWS TRANFO Tr 11 [t0dms RAS CeANEOH| TSU Te 7 MPa RWS [ANFO | 83 98 105 fovpa RAS (%ANFO!" 129 759 11 Notes: ‘LIn-hole densities of emulsions vary with depths. Please contact your regional sales offce for assistance in finding the best product fit for your application 2.The Relative Weight & Bulk Strengths are relative to ANFO [=100] at a density of 0,80 g/cm3. The figures have been determined using the VIXEN: detonation code. 3.The availabilty of the above offering is subject to MMU configuration, 4.In large diameter, typically 250 mm and above, a maximum of 3m lof water may be allowed. 5.The Relative Bulk Strengths and Effective Energies are relative to ANFO [=100) at a density of 0,80 gfem3. The figures have been, determined using the VIXEN-i detonation code Storage and Expiry SB300 Eco has a shelf life of 3 months Silos and Isotainers are the recommended storage facilities Storage sites must be secure Primers and Detonators should not be allowed in storage sites Transport (UN Classification) Do not transport primers and/or detonators with emulsion Base emulsion Class 5.1, UN No. 3375, AMMONIUM NITRATE EMULSION ” Compatibility Matrix - Surface Bulk Products ficconior S00 range [S100 Ew range] S200Ec | SeOD ange vanse ameter ml —E].|-12.|./2.|.J2. |DONORS oa Sossar ae Booster . . . . is Booster elet fete] pele tele Teg Booster Sia = = 2 = Tog Boece Sra set ete tebe pepe 20 © AEL Mining Services Lined | Product Catatgue, 2011 Underground Bulk Emulsions - UG100 Range Underground bulk emulsion explosives consist of 2 base emulsion and sensitiser, development and stoping Which are classified as non-detonable and non-explosive, respectively. UGIO0 is used in whereas UG100S is used primarily in up-hole/ring blasting but can alse be used in development. The suffix 'S’ in UGTOOS infers the product is ‘sticky’, which means it can effectively stick to the lining of blast holes, making it suitable for up-holes. The suffix ‘C’ in UGTOO C infers the product is customised as per specific site/customer requirements These products are characlerised as high strength denoted by the AEL manufactures all the necessary mabile charging equipment for these products Technical Specifications ‘Appearance The base emulsion is a honey coloured mixture of two immiscible liquids and an emulsifier. The sensitiser is an aqueous or emulsion product, which, when added to the base emulsion and mixed, creates an explosive in the blast-hole. Benefits and Features Benefits + Improved safety of use, labour utilisation and logistics + Easier adherence to explosive legislation + Improved fragmentation Features ‘High safety standards ‘High strength ‘High VOD ‘Water resistance + Low fume emissions Technical Properties Mining Method Underground Narrow Reef Massive 100 in the name. Application Tunnelling Stoping Massive Ring Blasting Product Range ue 100 uss008: Tepleacn — JBsvelapmantandaaping —] Up-olesirng Basing and development Talear lpase amcor faney —] Base eruton Pane senetizad emulsion onsen | Sonsiised emuleon blue Twraldeiveed —_[2uas Er Energy DEL Ma Rela Efecive OE Energy REE Reise due [17 7 Srengtn as" Mint intro Reng Pon aT | OS TN ToT FTE sees src zzuo-2000=P In PaOOT vor ata arom Saeer | SSDS eB TOT ha bole am camventonatstgngwts | holes ols tae than io he space nuts promer boosters recommendes ‘Genera priming is required Sleep Time 7 days maximum Reprod canbe edn Water resistance Excellent deter ster Sn Density Base Emulsion: 141-1.47g/ee | [Seca Pacauers Reverse pring should at] + Rance aTachans _ Sensitised Emulsion: 1.0-1.15q/cc Baer and cum fas Gap Sensitivity 0 Saint shoud beste | «Base emulscn adsense Repumpability Six Stages Shout stored seperate Storage and Expiry Storage Conditions Product Shelf Life Avoid high/low temperatures 3 Months for base emulsion and sensitiser, 8 months for emulsified aqueous sensitiser Transport (UN Clas: Base emulsion Class 5.1, UN No. 3375, OXIDIZING MATERIAL Sensitiser Class 5.1, UN No. 3099, OXIDIZING LIQUID, TOXIC, N.O.S. cation) ‘Use 0550 (Buel agueaus 1 Sensteas emulsion should ewell msec anditin ‘orac dena range oF BF50(Grean}emulsies Senses emulsion should Deer [Bok ervery in tankorsor | SUCRE RS baocedarout Gagged Ein [2x 1 589 3095 ma Gas, | a uags ger ton Sena Agent Pa a eave a CPE] Go OSH BRT SETS (Groanlemuisied rons pertonafbare smian 03| 35k of 8515 Loreen! sausous sense parton Sense per leno base “ing prads wha sal roca athe armulion is pemnent toa specie nf anyaroduct hes te sur Banged then products deLvrednbe55 © AEL Mining Services Limited | Product Catalogue, 2211 sas caletatedby Vier a Underground Bulk Emulsions - UG200 Range Underground bulk emulsion explosives consist of @ base emulsion and sensitiser, which are classified as non-detonable and non-explosive, respectively. UG200 is used in development whereas UG2005 is used primarily in up-hole/ring blasting but can also be used in development. The suffix 'S' in UG200S infers the product is ‘sticky’, which means it can effectively tick to the Lining of blast holes, making it suitable or up-holes. The suftix'C infers the product is customised on site to customer requirements. These products are characterised as high stability and suilable for use in remote areas and/or where large ‘temperature gradients are anticipated denoted by the 200 in the name. AEL manufactures all the necessary mobile charging equipment for these products, Appearance ‘The base emulsion is @ honey coloured mixture of two immiscible liguids and an emulsifier. The sensitiser is an aqueous product. wich, when added to the base emulsion and mixed, creates an explosive in the blast-hale Benefits and Features Benefits + Improved safety of use, labour utilisation and logistics * Easier adherence to explosive legislation + Improved fragmentation + Improved shelf life over UG100 range Features ‘High safety standards + Excellent stability High VoD. ‘Water resistance + Low fume emissions Technical Properties Sleep Time ‘days ma Velocity of Detonation +2 000m/s. Water resistance Excellent jensity Base Emulsion: 1.41-1.479/ce Sensitised Fmulsion: 1.0-1.15g/ee Gap Sensitivity a Minimum Initiator En} Repumpability __—5 000m/s Description Case Water resistance Excallent Gross Weight [kg] 26 Cartridge Density 1.18 nominal NEQ (kl 25 GapSensitivity 40mm 4D or 8g/m detcord Recommendations for use Use with AEL 80 strength detonators and always embed the detonator firmly into at least one-third of the explosive cartridge. When using for secondary blasting, ensure a minimum product layer of 25mm is maintained © AEL Mining Services Limited | Product Catalogue, 2211 Transport (UN Clas: Class 1.1D UN No. 0241, EXPLOSIVE, BLASTING, Type E Name: Magnum only applies to Africa and its offshore islands (all PEX) ‘orteacegurmentascnens trap at apron 25 Packaged Explosives - Anfex® Anfex@ is a free flowing Ammonium Nitrate and fuel oil blasting agent for use in commercial blasting operations. Antex’ *. Anfex@ fuel ratios are carefully controlled and provide the optimum chemical balance for good post fume The explosive is conveniently packed into 6.25kg detonation inner plastic bags. Technical Specifications ‘Appearance The product is packaged in a 25kg plastic bag, which contains four 6.25kg “multibags”. The prills are white to off-white in colour and may appear grey if recycled cll is used for fueling, Benefits and Features Benefits + Cost effective blasting solution ‘+ Can be pour- or blow-loaded ‘+ Misfired holes can safely be washed out with water Features ‘+ Comparatively safe when handling due to low sensitivity, to shock, friction and impact + Long storage life if stored correctly Technical Properties [AEL Anfex® does not contain any micro spheres which may be harmful if inhaled during pneumatic loading operations. Velocity of Detonation -3 500 m/s Water resistance Not water resistant imum Ini En} RWS 700 Bulk density OB Recommendations for use ‘Always prime withthe largest initiator possible, Pheumatically loaded Anfex® can be primed with a high strength detonator, ‘a booster or an explosive cartridge, 26 The prill characteristics are optimised to provide excellent resistance to friability yet loads exceptionally ‘well in pneumatic loaders. Mining Method Underground Narrow Reet Massive Surface Openpit Opencast Quarrying Construction characteristics Application Tunnelling Stoping Massive [uphole] Ring Blasting Trenching Openpit Quarrying Civils Special precautions 4 Do not use in wet mining conditions as Anfex® is water soluble + Do not use with detonating cord Storage and Expiry Storage Conditions Moderate temperatures and dry conditions ina well ventilatee, approved magazine Legal Storage % months in customers magazine Expiry Date x oenmanars 12 months Packaging Description Bag Gross Weight (kg) 25 NEG (kg) 25 Units per bag Tour multi bags weighing 6.25kg Transport (UN Classification) Class 1.1D UN No. 0082, EXPLOSIVE, BLASTING, Type B © AEL Mining Services Lined | Product Catatgue, 2011 [oqo me =} Specialised Explosives - Barrel (Pt Barret) Barrel is a watergel explosive that is packaged in special plastic tubes that can be clipped together for use in holes where a de-coupled charge is needed Applications include smooth blasting of perimeter holes in shaft sinking, development or tunnelling, Technical Specifications ‘Appearance The product is packaged in thin plastic tubes that are white to beige in colour and can easily be clipped together. Benefits and Features Benefits + Ease of use + Easily extendable by clipping end-to-end + Suitable for use in wet holes Features ‘Tailored energy for smooth blasting operations + The explosive size and energy is optimised to prevent overbreak + Can be initiated by a 6D detonator + Waterproof Technical Properties Velocity of Detonation 500 m/s. 58x 595mm Water resistance Excellent Cartridge Density 1.2 Nominal Recommendations for use Initiate with 2 minimum of a 4D strength detonator embedded in the explosive. Recommend primer in the toe of the hole. Use stemming for best results, © AEL Mining Services Limited | Product Catalogue, 2211 Mining Method Underground Narrow Reef Application Tunnelling Special precautions ‘= Although watergels are ofthe safest explosives manufactured, always handle with care + Keep detonators stored away from explosives + Store ina specialy licensed, cool and dry area for @ maximum of 48 months from the date of manufacture + Although watergels do not readily burn, Keep away from flames, ‘sparks and other sources of ignition Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved magazine Product Shelf Life 12 months Legal Storage ‘6 months in customers magazine Expiry Date i sossinmnirn 12 months Packaging Description Case Dimensions (LxBxH]_225x225x620 Gross Weight (ka) 25 NEQ (kg) 18 Units per case 170 Transport (UN Classification) Class 1.1D UN No. 0241, EXPLOSIVE, BLASTING, Type E Specialised Explosives - Blasting Gunpowder stone blasting, Blasting Gunpowder is mainly used in dimensional Mining Method Surface Quarrying Technical Specifications ‘Appearance A low explosive black or dark grey, granular, free-flowing mixture of potassium nitrate, sulphur and charcoal. Benefits and Features Benefits «Flexibility of use + Easy and simple to use «= Charges are custom-made on site Features ‘An intimate explosive mixture of potassium nitrate, sulphur and charcoal «Free flowing, dust free graphite glazed granular mixture Rendered inactive by water + Low shattering effect, which causes fewer fractures and results in more usable stone Safety Handling Gunpowder is highly sensitive to spark, flame and friction and must be handled with extreme care ‘Transport (UN Classification) Class 1.1D UN No 0027, BLACK POWDER [GUNPOWDER GRANULAR] Application Quarrying Special precautions * Blasting gunpowder is highly sensitive to impact, friction flame, spark and static discharge * Blasting gunpowder ignites when ground * Keep away from all sources of ignition, direct sunlight or strong incandescent light * Contamination with grit increases sensitivity to impact or friction * Temperatures >130° will lead to decomposition Storage and Expiry Storage Conditions Store alone under moderate temperatures and dry conditions. na well ventilated, approved black powder magazine Syears months in customer magazine years Product Shelf Life Legal Storage* Expiry Date inns Packaging Description Case Dimensions [LxBxH] 562x245x265mm Gross Weight {kl 27 tig] 5 Units per casefbag 10x 2.5kg AEL Mining Services Lied | Product Catalogue, 201 Compatibility Matrix - Packaged and Specialised Explosives Donor 3 ~o| & 2 a | 6 El] a] za] # a 3 Magnum® Buster (Zambia Only) . . Magnum® Control . o Magnum® Frag . . Magaum® Plus = * Magnum® Buster Gal . ° Magnum® 365 Gel e[e ‘Antex . *[elTelele Barrel = Shock Tube Uni-Delay LP epe[elel[el/e|ele Shock Tube Muli LPO. epel[elel[el/e|lele Shock Tube Multi SPO efel[ele|e]/e|lele Shock Tube Profiler efel[elelel]e|lele Capped Fuse Systems ~ Stopatuse® epe>elel.) el]. . Capped Fuse Systems - Durafuse® epe[ele|el]e|lele Electronic Delay Detonators - GuickShat™ efelelelelelele Electronic Delay Detonators Smaridet® efel[elelel]elele roni¢ Delay Detonators ~ SmartShot® efel[elel el] ele]. tronic Delay Detonators ~DigiShot® efel[elelelelele Electronic Delay Detonators - HotShot® Electric Intiators - Statsafe® Detonators epepepel ef efLele Instantaneous Electric Detonator VEDI epelTelelel/elele Electric nitiators - Fusehead Assembly . Electric initiators ~ Shurstart® © Powercord® B ope fe Pele Telefe le Powercord® 10 epee tele Tel ete le Pentolite Primers etpDerbertpeL-: lef. © AELMaing Sees Lite | Produc 29 30 AEL Mining Services Lied | Product Catalogue, 201 [oqo me =} Ammonium Nitrate Prill-Based Explosives - Bulk Anfex® Bulk Anfex is a Porous Prill Ammonium Nitrate and fuel oil blasting agent for use in commercial blasting operations. The prill characteristics are optimised to provide excellent resistance to friablity. The prills are mixed in-situ with fuel oil in Mobile Manufacturing Units Technical Specifications Appearance Bulk Anfex comprises prills that are white or aft-white in colour Benefits and Features Benefits + Cost effective blasting solution + Easy to charge using auger loading “ Misfired holes can safely be washed out with water * On-site manufacturing in MMU Features + Safe to handle due to low sensit and impact « Attains full coupling ity to shock, friction © AEL Mining Services Limited | Product Catalogue, 2211 (MMUs] or Anfo Loaders. Mining Method Surface Open Cast Open Pit Quarrying Construction Application Open Pit Quarrying Technical Properties Steep time Velocity of Detonation Not recommended 3500 m/s Recommendations for use + Use in dry bore holes * Sleeping charged Bulk Anfex is not recommended Special precautions Do not use in wet holes Storage and Expiry Storage Conditions Do not store Anfo ‘Transport (UN Classification) Class 1.1D UN No. 0082, EXPLOSIVE, BLASTING, Type B N ca] Ammonium Nitrate Based Explosives - Bulk Anfex® Eco Bulk Antex Eco Porous Prill Ammonium Nitrate and recycled fuel oil blasting agent for use in commercial blasting operations. The prill characteristics are optimised to provide excellent resistance to friability. The prills are mixed in situ with recycled fuel oil in Mobile Manufacturing Units [MMUs] or Anfo Loaders, Appearance Bulk Anfex Eco comprises prilis that are grey in colour: Benefits and Features jenefits + Cost effective blasting solution ‘Easy to charge using auger loading + Misfired holes can safely be washed out with water On-site manufacturing in MMU = Consumes waste oil Features ‘Safe to handle due to low sensitivity to shock, friction and impact + Environmentally friendly = Attains full coupling 32 Mining Method Surface Opencast Openpit Quarrying Construction Application Open Pit Quarrying Technical Properties Sleep Time Not recommended Velocity of Detonation 3.500 m/s Water resistance Poor Minimum Initiator 50g Booster Recommendations for use * Use in dry bore holes. ‘Special precautions = Do not use in wet holes Storage and Expiry Storage Conditions Do not store Bulk Anfex Eco ‘Transport (UN Classification) Class 1.10 UN No. 0082, EXPLOSIVE, BLASTING, Type B N © AEL Mining Services Lined | Product Catatgue, 2011 EXPLO: Compatability Matrix - Bulk Anfex® Products Acceptor Bulk Antex® | Bulk Anfex® Eco Diameter fmm) 2) | ele]&le Donors (60g Pentolite Primer 150g Pentolite Primer . . ‘400g Pentolite Primer ele ele 175g Pentolite Primer Smart . . ‘400g Pentolite Primer Smart ele ele ‘SD - Surface Dopes ‘5B - Surface Blends *Use plastic connector © AEL Mining Services Limited | Product Catalogue, 2211 33 36 AEL Mining Services Lied | Product Catalogue, 201 Initiating Systems Wealth Unearthed As a holistic provider of a comprehensive range of commercial explosives and solutions, AEL is proud of its locally developed and manufactured range of initiating systems suitable for all mining applications. With a long history and proven track record in the market, AEL is in a unique position to offer a range of products and solutions, on demand, to suit a vast variety of applications. and market requirements in the underground and surface mining fields. Its initiating systems and components are highly flexible, designed with the user in mind and are available as Standard and Made-To-Order products. Reinforcing ts position as. solution provider and leader in this field, AEL is fully equipped to offer technical support and services in South Africa, other African regions as well as internationally What differentiates AEL's offering is the fact that the enti range is conceptualised, designed, manufactured, delivered, supported and maintained by the organisation's various specialised divisions. This means AEL is in a Unique position in that it provides both solid, reliable initiating systems, as well as all the services around the products to offer customers complete peace of mind, AEL offers its customers in the mining and construction industry @ full range of initiating products including electronic detonators, capped fuses, igniter and detonating cords, as well as a comprehensive range of boosters and starters - all of which fully compliment the company’s entire range of explosive solutions. AEL's capped fuse technology and electronic detonators are considered to be leading technologies in the market place. The company has demonstrated its internal Research & Development team’s prowesswith the ongoing development of new shock tube technologies, which ha been well received inthe market place. AELs electronic detonator range is highly flexible and offers solutions to apptications of varying sophistication y Wining Services NUT RUN Shock Tube - Uni-Delay LP Technical Specifications ‘Appearance ‘length of shock tubing, which incorporates a 4000ms delay in-hole detonator that is crimped onto one end ‘and @ 200ms short delay out-hole detonator crimped onto the other end. Both detonators include either 2 rubber plug or sleeve. The out-hole detonator is located in a plastic connector body. There are two variants available, the Uni-Detay LP (6) or (3) which hold # maximum of six or three lengths of shock tube respectively, the later is ideally suited to narrow reef mining conditions Benefits and Features Benefits + Allin-hole detonators have the same delay ‘= Rugged, abrasion-resistant tubing «Easy to connect ‘= Easy to check connection sequence ‘ Ergonomically designed connector block makes connection of tubing easy Features +20 hole burning front + Clear plastic connector body (6) or an orange connector body (3) Clear shock tubing + 18-25kg minimum break load + Immune to hazards of radio frequency radiation, stray currents and static discharge Product Range A Uni-delay LP (long period) is @ non-electric initiation system which is designed for use in underground mines. The unit consists of both a ‘an out-hole and an in-hole delay detonator. Out-hole In-hole Nominal delay periods ms} 200ms ‘o00ms Colour code Ciear(6l ‘la range (31 ala 36 Mining Method Underground Narrow Reef Application Tunnelling Stoping Technical Properties Detonator strength __8 strength SleepTime 4B hours Gore toad of tubing ismoim VOD of tubing = 2000m/s =3mm Excellent Special precautions ‘= Handle with care - detonators are explosive ‘= Temperatures >90°C may result in spontaneous explosion '* Severe impact on the detonator or tubing can result in accidental initiation and explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in @ well ventilated, approved magazine Product Shelf Life 18 months| Legal Storage* 6 months Expiry Date® vananvanacua 12 months Packaging Description Case imensions (LxBxH) ___565x295x270mm, Gross: 25kg Length tml Units per case NEO eg] Z 300 06 25 300 6 a 300 05 35 250 05: & 250 oe 45 200 04 5 200 Oe é 150 3 7 10 os Transport (UN Classification) Class 1.18 UN No 0240, DETONATOR ASSEMBLIES, NON-ELECTRIC + ortega reurenenc in egin opetion © AEL Mining Services Lined | Product Catatgue, 2011 Shock Tube - Splitter INITIATING SYSTEMS A Splitter is @ non-electric initiation system which is designed for splitting the blast timing in multiple directions, in underground mines. The unit consists of two out-hole delay detonators. Mining Method Underground Narrow Reet Application Tunnelling Technical Specifications Appearance Alength of shock tubing, which incorporates an out-hole delay detonator crimped onto each end. Both detonators include either a rubber plug or rubber sleeve. Both detonators are located in a plastic connector body. The plastic body is colour-caded according to the delay of the out-hole detonators. Benefits and Features Benefits ‘* Rugged, abrasion-resistant tubing Easy to tie-up ‘The unit will initiate one or more Uni-Delay and Teunkline assemblies, Features ‘* Uni-delay timing system: 100ms or 200ms * Colour- coded connector blocks indicate delay number Green coloured shock tubing ‘= 18kg minimum break load Stoping Technical Properties Detonator strength 2 strength equivalent Core toad of tubing - 1ma/m VOD of tubing = 2000m/s Outside diameter of tubing — 3mm. Water resistance Excellent Special precautions ‘+ Handle with care - detonators are explosive ‘Temperatures >90°C may result in spontaneous explosion + Severe impact on the detonator or tubing can result in accidental initiation and explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved magezine Legal Storage* 6 months in customer magazine Expiry Datel jonacinnaani 12 months + Immune to hazards of radio frequency radiation, stray | Packaging cose currents and static discharge imensions (LxBxH] 65 x 295 x 270mm Gross weight [ks] 72 Length i Units per ease: NEO Teg] 7 70 318 Product Range 1 2 ore z 700 O39 Connector block Brown White Nominal delay periods ims) | roo/100ms | 200/200ms || Transport (UN Classification) © AEL Mining Services Limited | Product Catalogue, 2211 Class 1.1 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC + ortega reurenenc in egin opetion 37 INITIATING Shock Tube - Multi SPD ‘A Multi SPD [short period delay] is @ non-electric initiation system which is designed for use in underground and surface mines. The unit consists of an in-hole delay detonator. Mining Method Underground Narrow Reet Massive Surface Opencast Open Pit Quarrying Construction Application Tunnelling Stoping Technical Specifications ‘Appearance ‘A length of yellow shock tubing, which includes a short period delay in-hole detonator. The detonator includes either a rubber plug or sleeve that is crimped on one end. The detonator delay period is printed along the length ofthe detonator shel. The free tend of the shock tube is sealed and incorporates a colour-coded connector clip, which indicates the delay period. & tag behind connector the clip indicates the length of tubing, as well as the delay time. Benefits and Features Benefits + Delay is already in the hole + Rugged, abrasive-resistant tubing + Easy te tie-up + Easy to check blast for correct timing sequence due to Ring Blasting Trenching Open Pit Quarrying Civils Technical Properties Core toad of tubing = 15ma/en VoD oftubing ——— 2000m/s. Outside diameter of tubing — 4mm. Water resistance Excellent Storage and Expiry Storage Conditions Moderate temperatures and dry ‘conditions in a well ventilated, approved magazine Product Shelf Life 18 months’ Legal Storage* “é months in customer magazine Expiry Datel rindi 12 months Product Range highly visible connector clip colour coding aE + Detonator is 8 strenath a oan searial 18078 | 200 | mas 280] 28 Features Gaur cae [Ugh Bue] Beige [ Cle | trey Dara Pak mer Fons sya] 300 [325 | — 360 [978] con | + Twenty eight diferent short period delays tetarese "| Gury | Pak [Feng Peac- PVE oo + Colour coded connector clip indicates delay number Nerina eyes <50|e75 | 500 [400 [700 [000 * Connector elip connects assembly to detonating cord So ee Sed trunk-tine Colour code [Cavender [ght brown Lah rey Berna + Yellow coloured shock tubing ‘+ 18kg minimum break load on shock tubing Units per case/bag + Immune to hazards of radi frequency radiation, stray Tengthy Units per] NEO Tal] Teng [Units pr [NEG Tig] currents and stale discharge on) a ic) case 2 2003 * 130-02 Packaging 25. 70_[ 03 i too—| “07 3 7093 2 100—| 01 Beet ea 35 zo 7 a 30-07 mensions [LxBX 565 x 295 x 270mm z 3037 a [or Gross weight (kg) 2 a zo0[ 02 2 [07 5 zoo 07 5 a Special precautions 55 zo “37 3 07 * Handle with care - detonators are explosive ‘ seo_{ 0.2 38 2s {on + Temperatures >90°C may result in spontaneous explosion z tw [a2 a af on Temperatures >90°C may result in spont x t qf 32 + Severe impact on the detonator or tubing can result in accidental initiation and explesion 38 Transport (UN Classification) Class 1.18 UN No 0340, DETONATOR ASSEMBLIES, NON-ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 Shock Tube ~ Multi LPD INITIATING SYSTEMS ‘A Multi LPD [long period delay] is a non-electric initiation system which is designed for use in underground and surface mines. The unit consists of an in-hole long period delay detonator. 1g Method Underground Narrow Reef Massive Surface Construction Application Tunnelling Technical Specifications ‘Appearance ‘A length of green shock tubing, which incorporates a tong period delay in-hole detonator. The detonator includes either a rubber plug or sleeve that is crimped on one end. The detonator delay period is printed along the length of the shell. The free end of the shock tube is sealed and incorporates @ colour coded connector clip indicating the delay period. A tag behind the connector clip indicates the Length of tubing, as well as the delay period, Stoping Trenching Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved magazine uct Shelf Life 18 months’ Legal Storage™ ‘6 months in customer magazine Expiry Date# ronan 12 months Product Range Benefits and Features Tee Sao Bw | Heer | Crepe Ca jenefits tsurina—an0 [700 | —000—[ toot abo | so + Rugged, abrasion-resistant tubing Sra Ss Pee Co 1 ugar sor woanseayinn| “TO aop0 | 300 [000 | S00 | ae yt ti-up SS seer ee eed Eee teeta * Checking blast for correct timing sequence is simplified due | [yeasasstyaal “Bor | isos | suse | ose] po to hight visible connector clip celour coding ‘Star mes tee Perfor Tn Features +23 diferent ong period delays Fackasing '* Colour coded connector clip indicates delay period Description Case + Connector clip connects assembly to detonating cord ora Claster| Dimensions (LxBxH) 565 x 295 x 270mm '* Green coloured shock tubing Gross weight (kg) 22 4 184g minimum break load on shock tubing + Immune to nazarés of radiofrequency radiation stray Units per case/bag currents and state discharge Tengih [Unitsper|NEQTWG]] [Length [Units per] NEOs) (ol | “ease tm) | ease , , 7 : Technical Properties = ao 5 ae Detonator strength a strenatn z 0a 7 Too Zeeks linchola) 35-0 [a2 i 7 [ot Green tabing az zo 02 i ao =t5malm “5—[ 0 [07 Fi so [ot : a0 [a7 3 so [oot $5 [ mo] 3 a a é v7 [ a7 3 a [or Water resistance Eaeellent + is [ a2 ts 7 [or = soa Special precautions + Handle with care - detonators are explosive + Temperatures >90°C may result in spontaneous explosion + Severe impact on the detonator or tubing can result in accidental initiation and explosion © AEL Mining Services Limited | Product Catalogue, 2211 Transport (UN Classification) Class 1.18 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC {Sigeeteltycotman 39 INITIATING Shock Tube - Uni-Delay SP Mining Method Underground \ Narrow Reet [A Uni-Delay SP (short period] variant is a non-electric | Massive initiation system which is designed for use in | Surface underground and surface mines. The unit consists of | Opencest an in-hole and an out-hole delay, each with a selection | Conf Sion of delay times. ‘Application Stoping Trenching Open Pit Quarrying Appearance 5 ae Civils torage and Expiry ‘length of yellow shock tubing, which incorporates an in-hole detonator crimped onto one end and a short delay out-hole Storage Conditions Moderate temperatures and dry detonator crimped onto the other end. Both detonators condiions mawellventiated, incorporate either @ rubber plug or sleeve. The out-hole | = ————_________approved magazine _ eee eneeee ee att connec ben Product Shelf Life 18 months? etonator is located in a plastic connector body, which is | PreductShelfLife __18monthst_—_~_ colour-coded according ta the delay ofthe out-hote detonator, | EegalStorage* months in customer magazine — ‘The out-hole delay detonator time and shock tube length is Expiry Date" onsenvmnmam 12menths printed on a label attached ta the shock tube. The in-hole detonator delay period is printed along the length of the | Product Range detonator shell Surface Delay Nominal delay eT [17 B a a Benefits and Features Colour code Blue [Grange [Dare geen | You Benefits Nominal éelayimsi| 75 [100 125 150 « Accurate delay sequence Colour code Red_[ Brown [Ugh araan | Cant ate + Rugged, abrasion-resistant tubing Nominal éelayimsi| 175 [200 | 225 250 + Easy to connect Colour code Beige [Clear [Grey | Sara pink + Eliminates the eequirement far detonating cord and relays in -Hole De In-Hole Delay + Reduced noise levels as compared with detonating cord TESTA eco aw Features + Various surface and in-hole delays + Contains optimally charged detonatar far shock tube initiation Description Case inboth directions Dimensions (LxBxH] 545 x 295 x 270mm + Yellow coloures shock tubing Gross weight {kg} 2 + 184g minimum break load + Immune to hazarés of radiofrequency radiation stray currents | Units per case/bag and static discharge Tengthy [Urits per] WEa el] Tength [Units per [NEQ Tra] Technical Properties Ae 90°C may result in spontaneous explosion + Severe impact on the detonator or tubing can result in accidental initiation and explasion + Do net atternpt to initiate detonating cord with this product © AEL Mining Services Limited | Product Catalogue, 2211 Transport (UN Classification) Class 1.18 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC “a INITIATING Shock Tube - Cluster ACluster is a non-electric initiation system which is designed for use in surface mines. The unit consists of a trunk line delay detonator housed in a cluster connector block Technical Specifications ‘Appearance ‘A length of green shack tubing that incorporates a short period delay detonator. The detonator includes sleeve that has been crimped on one end with @ given length of shock tubing. The free end of the shack tube is sealed and incorporates a colour coded connector clip. The delay period is also printed along the length of the detonator. The detonator is fitted into a colour-coded cluster connector block. The delay period and shock lube length is printed on a label attached to the shock tube, Benefits and Features Benefits + Accurate delay timing ‘+ Rugged, abrasion-resistant tubing + Easy touse + Flexible blast design + Initiates detonating cord or shock tube Features * Thirteen diferent delays + Colour-coded connector clip and cluster connector block indicates delay time + Green coloured shack tubing + 18kg minimum break load on shock tubing + Immune to hazards of radio frequency radiation, stray currents and static discharge Technical Properties Opencast Open Pit Quarrying Construction Application Trenching Open Pit Quarrying Civils Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved magazine Product Shelf Life 18 months: Legal Storage* ‘é months in customer magazine Expiry Date# hn ssesmune 12 months Product Range ‘Nominal delay (mal | 0 7 % 3 Colour ca Turuase| Blue | Orange | Dari aren ‘Nominal delay fs] 7 00 125 Calour cede | Reg | cat Cae Nominat delay TST | — 150 —[ 175 0 slour ode ast sue| Beige} ear com ‘Nominal delay msl | 250 Colour code Dark pink Packaging Description Case Dimensions (LxBxH] 565 x 295 x 270mm. Gross weight (ka) 2 Units per case/bag Detonaterstensth cstength tego [Pane peo Shock Tbe Ceour bass —--— 5 Core tad ott "gr $e i Weber uing So ee a Special precautions ‘ Handle with care - detonators are explosive + Temperatures >90°C may result in spontaneous explosion + Severe impact an the detonator or tubing can result in accidental initiation and explosion + Do not attempt to initiated shock tube and detonating cord simultaneously by means of the cluster connector block 42 Transport (UN Classification) Class 1.18 UN No 0360, DETONATOR ASSEMBLES, NON-ELECTRIC (CAEL Mining Services Lined | Product Catatgue, 2011 Shock Tube - Lead-in INITIATING SYSTEMS aS A reel of shock tube with a detonator encased in a cluster connector block, used to extend the blast to ‘a safe initiation point. ing Method Surface Opencast Open Pit Quarrying, Construction Application Trenching Open Pit Quarrying Technical Specifications ‘Appearance ‘A length of shock tubing spooled onto a reel. One end of the tubing is crimped into a short period delay detonator. The detonator includes a rubber plug that has been crimped on fone end, The free end of the shock tube is sealed and incorporates a colour coded cobra clip. The delay period is also printed along the length of the detonator. The detonator is fitted into a colour-coded cluster connector block. A tag altached to the shock tube indicates the length of tubing, as well as the delay period Benefits and Features Benefits * Highly visible components - greater safety + Rugged, abrasion resistant tubing + Easy to use + Reduced noise + Positive initiation control Features + Tubing is spooted, for easy off-reeling ‘The cluster connector block has a positive locking cover + Green coloured shock tubing + 18kg minimum break load on shock tubing ‘Immune to hazards of radio frequency radiation, stray currents and static discharge Cimits ‘Special precautions + Handle with care - detonators are explosive + Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry ‘conditions in a well ventilated, approved magazine Product Shelf Life 8 months” LegalStorage* 6 months in customer magazine Expiry Datel oss cnunand 12 months Product Range nial acyl [ [2 Packaging Dimensions (LxBxH) 510x270x250mm Grossweightikg) ==99 sstsi—SS Units per case/bag Length | Units per | NEQ ka) case Technical Properties 70m TO rele a Detonator strength strength 500m Zreels a7 Core toa of tubing =15ma/m hee se Transport (UN Classification) Minimum initiator 33,6g/m detonating card © AEL Mining Services Limited | Product Catalogue, 2211 Class 1.18 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC INITIATING Shock Tube - Extender _> 4 reel of shock tubing with a separate 10cm length of clear plastic joiner tubing, which can be used to join shock tube ends in order to extend the initiation point toa safe distance from the blast Technical Specifications ‘Appearance Areal of shock tubing with a separate 10cm length of clear plastic joiner tubing, which can be used to join reels to extend the length of shack tubing as well as join an HTDA leading to the first hole on a blast ‘A.black end cap is used to seal both ends of the tubing as to prevent powder loss andor moisture ingression, Benefits and Features Benefits ‘Rugged, abrasion-resistant tubing + Easy to use + Joiner increases distance from blast Features * Green coloured shack tubing 1 184g minimum break load + Joiner tube enables easy extension to required length + Immune to hazards of radio frequency radiation, stray currents and static discharge Technical Properties Gore toad oftubing _—15mafm VoD oftubing = 2000/5 Outside diameter oftubing = 3mm 1g Method Underground Narrow Reet Massive Surface Opencast Open Pit Quarrying Construction Application Tunnelling Stoping Ring Blasting Trenching Open Pit Quarrying Civils Special precautions + Store in a specially licensed, cool and dry area for not more than 18 months from the date of manufacture Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, ——___ approved magazine Product Shelf Life ‘18 months" Legal Storage* “é months in customer magazine Expiry Datel rossacunnsand 12 months Product Range + 500m Packaging Description Case Dimensions (LxBxH] ___510x270x250mm Gross weight (ka) 9 Negi) OOD Units per case/bag Length Units per case 500m Precis Transport (UN Classification) N/A (CAEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Capped Fuse Systems - Stopefuse® and Durafuse® A length of safety fuse capped with a detonator at one end and an igniter cord connector at the other. Mi ing Method Underground Narrow Reet Application Tunnelling Technical Specifications Appearance ‘The AEL capped fuse products are supplied with a length of green Durafuse® or red Stopefuse®. The product varies in length depending on the depth of the hole. Benefits and Features nefits * AEL capped fuse assemblies perform reliably in wet underground mining environments. + Supplied ina range of lengths to sut diferent customer needs Stoping Special precautions ‘+ Handle with care - damage to the fuse or components could lead to mistires + Severe impact on the detonator or the fuse can result in accidental initiation and explosion + Avoid all possible sources af ignition ‘Never pull the components off the fuse “Never connect the blast until all the charging operations have been completed Product Range + Graded fuse improves sequential ing by reducing buring speed | [Frese | Fusecsuur | RaTnaNTAT | Dieser Sua ae variability — Sopa | ae | eee ao + Low cost system that performs reliably Torta | —saiao tub 08 + Resistant to fuel-aldecharged from compatible explosive products Torts gayao gab Darts | Grr a 2100 mH Features 17 ‘tae 7 + Connector has a specially designed cllar to retain igniter cord and 1 oo “at ensure effective heat ranster Taec a —| “400 7 + Triple eimping ofthe detonator tothe fuse, to provie fective a ra seals against water and fuel-ci ingress Tr ‘ata ut + Individual bundles are grades according to burning speed and colour Tee —[~inian 7 ‘coded ta facilitate matching of corresponding burning speeds for Bora —[ ~s9)90 at ‘optimal sequencing of shots aeoraet [ano iat + Certain variants availabe in half packs a SD uz Units per case Technical Properties P Tanah [Unter Tar trons Detonator strength aD ora ‘ase | dimensions | weight i Sleep time Te hours Ta hes Gore oad Sg/m a pens Dimensions 48 t05.1mm 00 ama] 79s sens | Water resistance Excellent 1s S00 stexaexaes | 20 Tem Fag | 0 | aeoxcaeees [10 ae isp arssssaes [oo Storage and Expiry Tanta | 7s [uae [10 7 Sst Parser | Storage Conditions Store in an approved segregated, a cool and well ventiated magazine | EE eee Produet Shelf Life 1 months from sate of manufacture. | [Zantac | Ve [sence [10 Legal Storage" months in customer magazine Zi fois | a0 sot [arses [9 Soma EE | 190 Preece [1 Recommendations for use Sin ayaa ‘Toaplimise sequential fring tic recommended that users | [eamialans{ so uegxtnasas [0 tiate capped Durafuse® with Duraline® or Slowiine® and | [sentatmer| tas ——[umncaaes | 16 Stopetuse@ with Stopetine® 9 ar Stopeline®. aa 355 pease | + For best results employ capped Stopefuse in stoping applications: and capes Durafuse® in tunnelling and development applications © AELMinng Services Limited | Product Catalogue, 2211 Transport (UN Classification) Class 1.10 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC oringl ‘gure rei feetion 45 INITIATING Capped Fuse Systems - Shock Tube Starter A non-electric shocktube starter consisting of either 2 1.2m long capped Durafuse® assembly or a 2.1m long capped Stopefuse 290 assembly. The AEL shocktube starter is available in two product ranges. The first range is comprised of 2 red capped Stopefuse® length packaged in a box containing 50 units. The second range comprises of 100 units of green capped Durafuse®. ‘A hollow polyethylene body [minidet tube] is fitted over the detonator and crimped over it with an aluminium ferrute Mining Method Underground Narrow Reet Massive Surface Opencast Openpit Quarrying Technical Specifications ‘Appearance ‘The assemblies are constructed by crimping a slotted igniter cord connector at one end and a 6D strength detonator at the other end of the respective fuses. Benefits and Features Benefits + Secure attachment of shock tube to the minidet ‘+ Minimal generation of shrapne\ + Reliable initiation ofthe shock tube + Slow burning speeds to provide sufficient time for safe evacuation Features ‘The detonator is encased in a plastic body 1 The detonator and its crimp are kept waterproof by the plastic body + The siat positions the receptor shock tube directly in the path of the detonator blast to optimise transfer of shock energy + The plastic body includes a moulded clip to secure the shock tube to the detonator Technical Properties Detonator strength 6D Goreload fuse) = 6.5q/m Fuse diameter 48 t0 5.0mm 0D Waterresistance Excellent Construction Application Asa starter for Shock Tube Recommendations for use For best results initiate the shock tube starter with an igniter cord Special precautions + Handle with care - detonators are explosive + Temperatures >100°C may result in spontaneous explosion, + Severe impact on the detonator or fuse may result in an explosion + Avoid all possible sources of heat ‘+ Never connect the blast until all charging operations have been completed Storage and Expiry Storage Conditions Store in an approved segregated, cool and well ventilated magazine Product Shelf Life 18 months from date of manufacture LegalStorage* months in customer magazine Packaging Description Case Fuse type [Units per] Dimensions case | (mm) Duratuse® | 100 _[S00x270x875 Stopetuse@27] 100 _[300x270x575 Product Range Fuse type | Fuse length (m) | Colour | Average Burning time Durafuse® [12 Green | 132s = 2min 125| Stopefuse®] 12 Red__[azas=5 min 245] 4 Transport (UN Classification) Class 1.18 UN No 0360, DETONATOR ASSEMBLIES, NON-ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Capped Fuse Systems - AEL Igniter Cords Flexible, incendiary cord comprising of a copper wire core covered with a plasticised, incendiary composition and waterproofed with a thin layer of polyethylene. The cord burns progressively with a constant, robust vigorous and Variants are: Duraline™, Stopeline®, Stopeline® 9 and Slowline™. external flame ing Method Underground Narrow Reet Application Tunnelling Technical Specifications Appearance Four types of igniter cords are manufactured by AEL: + Slowline ~ 2 single cord that is ivory in colour * Duratine~ a single green cord equipped with a parallel wire to impart greater carcass strength + Stopeline- a red twin cord + Stopeline 9~ a mauve [purpel twin cord Benefits and Features Benefits * AEL Igniter cords perform reliably in wet conditions + Supplied ina range of long lengths to suit different customer needs + Supplied in siow and fast burning speeds to enhance sequential firing + Reliable and affordable system of initiation + Simple to use and versatile Features + Flexible and easy to extend + Easy to connect into branch lines + Substantial heat output from the twin cords * Burns under water Stoping Recommendations for use Igniter cords are used to initiate capped safety fuses in various blasting applications. Special precautions ‘Igniter cords are sensitive to impact, friction, flame, sparks and static discharge ‘Igniter cords burn fiercely, even under water, producing a fireball ‘of high temperature gas + Avoid all possible sources of heat ‘Temperatures above 160°C may result in spontaneous ignition Storage and Expiry Storage Conditions Store in an approved segregated, cool and well ventilated magazine Product Shelf Life 118 months from date of manufacture Legal Storage” “months in customer magazine Packaging Description Case Units per case Stopeline Technical Properties reas iverson) | woah ig) Sleep Time » hours oto 755753 1 © 2x si B05 7 Water resistance Excellent as 2B OT a Bx? Toor Sues W320 % Product Range —— — Type |Selour | Burning rate [Principal application Toa Sara 765 i ‘simi 5x24 10am Se 6020 a Sapaine | Red} a0 ws Seema eager] | HEE rae 8 sloping. Use with 12 and 1.5, en Stopfuse270 rrr Beara 7 Tnnartow reotmmnnawinahor | | [osetia Sig 720 i Stopeline Mauve | 181030 Jngey nates orn applications | | [ssn ZS 2a 5 3 requiring greater burning Front Stowline Use with 0.9m Stosetuse 290 aie as = Dore [esen | SET ring waco | | Geaesim —— aeeneee af rnportance. Use wth rat Blowline | Wary | S0t045 _| Tuaneling. development and Transport (UN Classification) general purpose Class 1.46 UN No 0066, CORD, IGNITER © AEL Mining Services Limited | Product Catalogue, 2211 *origtrgureerts iri feeatin ar INITIATING Electronic Delay Detonators - QuickShot™ Plus QuickShot Plus is a pre-programmed electronic initiation system for underground mines, which allows customers the benefits seen when using accurate timing in tunnelling applications. QuickShot Plus is a plug-and-play system where user interaction can be kept to @ minimum. QuickShot Plus offers simplified daisy chain linking, which enables easy visualisation of the blast. In its simplest form customers simply connect QuickShot Plus detonators in the order in which they want the round to fire. This makes the system easy to use and easy to understand, QuickShot Plus can be used as a stand alone system or as part of a centralised blasting network. Mining Method Underground Narrow Reef Massive Technical Specifications ‘Appearance A-copper detonator that is crimped onto a yellow-coloured, flat 4-wire copper cable downline on one end and terminated with two over-moulded connectors on the other end. Benefits and Features Benefits ‘Improved fragmentation ‘+ Maximum face advance + Sequential firing + Increased blast cycle due to better muckpile distribution, resulting in a major decrease in cleaning time Features * Daisy chain connections + Network connectivity ‘+ Continuous testing of the installation + Immune to stray currents Technical Properties Delay time Pre-programmed or programmable with delay and pause markers Detonator strength 8D Water resistance Excellent Wire diameter Flat cable, 2mm 48 Application Tunnelling Stoping Product Range Downline xSurface] Units per | NEQ(kg] Length (ma) case 18x09 20 0.090 1.8 x 0.9 {heavy duty) 90 0.090 42 x09 3 0.054 0x09 5. 0.0 75x09 54 0.054 Special precautions + Handle with care - detonators are explosive + Ternperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved maga: Product Shelf Life 36 months Legal Storage* ‘& months (SAI Expiry Date# jossssmaman T2months SA) Packaging Description Case Box Dimensions (LxBXH)__480x 216x 252mm, Transport (UN Classification) Class 1.18, UN No, 0030, Product Group 2, DETONATORS, ELECTRIC. Class 1.45, UN No 0456, Product Group 2, DETONATORS, ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 Electronic Delay Detonators - Smartdet® INITIATING SYSTEMS A user-friendly, fully programmable electronic detonator that can accomodate complex blast designs where flexible milli-second timing is required ‘Smartdet has a unique, patented test-on-connect feature, which ensures successful deployment of the unit, Technical Specifications ‘Appearance A copper detonator that is crimped onto a round, red- coloured, twin-core steel downline on one end and terminated with a yellow connector on the other end, Benefits and Features Benefits ‘+ Improved fragmentation ‘+ Maximum face advance ‘+ Sequential firing ‘+ Increased blast cycle due to better muckpile distribution, resulting in a major decrease in cleaning time ‘= Saving of up to 30 percent in number of holes drilled, due to the ability to stretch existing blast design criteria Features + Inter-hole delay flexibility + Pre-blast testing of all detonators + 100 percent factory testing provides new levels of reliability + Immune to stray currents + Immune to electromagnetic radiation Technical Properties Delay time Set by user in Ims steps, range is 1 to 20 000ms Detonatorstrength 80 SSS Waterresistance Excellent. SSS Wire diameter =3.5 mm outer diameter © AEL Mining Services Limited | Product Catalogue, 2211 Mining Method Underground Narrow Reet Massive Surface Opencast Opengit Quarrying Construction Application Tunnelling Stoping Massive [uphole] Ring Blasting Trenching Open Pit Quarrying Civils Special precautions ‘+ Handle with care - detonators are explosive + Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a welt ventilated, approved magazine Product Shelf Life ‘36 months. | Storage* ‘6 months [SA] Expiry Datel jon suscnmannn T2months (SAL Packaging Description Case Box Dimensions (LxBXH)__575x300x 270mm Units per case/bag Tength [Units per] NEQ Tal] Tengih [Units per ]NEQ kal 12 165 | oes 7 a6 | ose 3 1000.10, 0 ‘30 [- 0930 a2 100] 0.10, “0 200.020 é 96 | 0.096 30 16 [0006 10 30 [0.090 a0 nso. 15 oo _ [0.060 70 10 oot 2 [ous Transport (UN Classification) Class 1.18, UN No, 0030, Product Group 2, DETONATORS, ELECTRIC a“ INITIATING Electronic Delay Detonators - SmartShot™ The SmartShot system offers innovative features including wireless remote blasting and complete timing flexibility Specialised waterproof and dirt displacing connectors ensure quick, easy and reliable connections and prevent leakage. The system also enables users to achieve the precision timing benefits of electronic initiation systems with the easy connections of current non-electric shock tube systems. Mining Method Underground Massive Surface Opencast Openpit Quarrying Construction Application Tunnelling Trenching Technical Specifications Appearance A-copper detonator that is crimped onto a green-coloured, flat -wire copper cable downline on one end and terminated with two over-moulded connectors on the other end. Benefits and Features Benefits ‘Accurate timing + Wireless remote blasting + Ease of deployment * Blast design flexibility Features * Daisy chain connections. + Software detects and warns of detonator and harness faults + Multiple level of hard and software security measures, ‘+ Immune to stray currents ‘Designed to be initiated by firing equipment and specifically designed for use with the SmartShot system. Technical Properties Delay time Fully programmable - range is 1 to 20 000ms Detonator strength 8D Water resistance Excellent Wire diameter Fiat cable, 2mm Downline wire type Copper 4-wire Special precautions ‘+ Handle with care - detonators are explosive + Temperatures >90°C may result in spontaneous explosion 50 Open Pit Quarrying Civils Product Range Length (ml 1.18 & 1.45 Downline Surface [Units per case | _NEQUks) 10 5 18 0.018 70 T TE uae 70 io 18 0.078 15 5 18 a.078 15 7 18 2.078 15 10 18 0.018 20 a2 18 0.018 20, 3 18 ate 20 10 is a018 20 15 18 2.018 30, a2 18 0.078 35 a2 18 a.078 Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a well ventilated, approved magazine Product Shelf Life 36 months. Legal Storage* 6 months (SA) Packaging Description Case Units per case 18 Box Dimensions (LxBXH) 480x217 x 252 NEQ kg) 0.018 Transport (UN Classification) Class 118, UN No 0030, Product Group 2, DETONATORS, ELECTRIC Class 1.48, UN No 0456, Product Group 2, DETONATORS, ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Electronic Delay Detonators - DigiShot™ DigiShot is an easy-to use, reliable electronic initiating Mining Method system for use primarily in surface blasting applications. Underground Massive ‘The DigiShot electronic initiation system represents an Surface innovative advance in technology, which enables users} Opencast to achieve the accurate timing benefits of electronic Openpit initiation systems with robust all-weather wire-leads eer and surface connectors. Application Tunneling Massive (upholel Ring Blasting Trenching Open Pit Quarrying ciwis Technical Specifications Appearance Storage and Expiry The detonator shell is copper with two steel wires Storage Condi Moderate temperatures and covered in red PVC plastic as the downline and coils dry conditions in a well have clear plastic shrink sleeve ventilated, approved magazine Product Shelf Life 36 months Legal Storage* ‘6 months (SA) Benefits and Features Expiry Date# ton sewmnnam 12 months [SAl Benefits Easy-to-use ‘+ Minimal on-bench components to simplify use + Automatic or programmable delay timing + Fully functionality testing Packaging Case Box Dimensions (LxBXH) 455 x 305x 215mm, Features 4.18 + Rugged reliability Length (ml Units per case NEQ tig + Immune to stray currents 7 720 TI20 + Designed to be initiated by fring equipment specifically 30 102 T02 designed for the DigiShot system a 5 a Technical Properties 20 30 Delay time Fully programmable - range is B 30 10 20 000ms Detonator strength 8D Water resistance Excellent 5mm OD 30 72 Transport (UN Classification) Class 1.18, UN No, 030, Product Group 2, DETONATORS, ELECTRIC Class 145, UN No 0456, Product Group 2, DETONATORS, ELECTRIC Special precautions ‘Handle with care - detonators are explosive ‘+ Temperatures >90°C may result in spontaneous explosion © AEL Mining Services Limited | Product Catalogue, 2211 . eterna arene 51 NUT RUN Electronic Delay Detonators - DigiShot™ Plus DigiShot Plus is an easy-to use, reliable electronic initiating system with remote firing capability The DigiShot Plus electronic initiation system represents an innovative advance in technology, which enables users to achieve the accurate timing benefits of electronic initiation systems with robust all-weather wire-leads and surface connectors, Mining Method Underground Massive Surface Opencast Openpit Quarrying Construction Application Tunnelling Massive luphote} Ring Blasting Trenching Technical Specifications Appearance ‘The detonator shell is copper with 2 -steel wires covered in green PVC plastic as the downline and coils have clear plastic shrink sleeve Benefits and Features Benefits + Easy-to-use ‘+ Minimal on-bench components to simplify use + Automatic or programmable delay timing + Fully functionality testing Features + Rugged reliability ‘= Immune to stray currents Designed to be initiated by firing equipment specifically designed for the DigiShot Plus system ‘+ Remote firing capability Technical Properties Delay time Fully programmable - range is 1 to 20.000ms Detonator strength 8D Water resistance Excellent Wire diameter 3.5mm OD Special precautions ‘Handle with care - detonators are explosive ‘+ Temperatures >90°C may result in spontaneous explosion 52 Open Pit Quarrying Civils Storage and Expiry Storage Condi Moderate temperatures and ry conditions in a well ventilated, approved magazine Product Shelf Life 36 months. gal Stor: ‘& months (SA) Packaging Description Box Dimensions (LxBXH] 455x305 x 215mm Case 1.18 Length (ml Units per case Te 120 30 Tz NEQ tig) 0.720 0.102 Transport (UN Classification) Class 1.18, UN No 0030, Product Group 2, DETONATORS, ELECTRIC Class 1.48, UN No 0456, Product Group 2, DETONATORS, ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Electronic Delay Detonators - HotShot™ HotShot is the world’s first auto-programmable electronic initiation system designed to optimise blasting results. HotShot is user-friendly, simple to understand, easy to deploy, flexible in a wide range of blast configurations and offers the accuracy of an electronic detonator, The HotShot system is an important advance in technology and enables users to experience the precision timing benefits of electronic initiation systems melded with the easy connectivity options of current non-electric shock tube systems, Mining Method Surface Opencast Openpit Quarrying Construction Application Trenching Open Pit Technical Speci Appearance A copper detonator that is crimped onto a red-coloured, flat 4-wire copper cable downline on one end and terminated with two over-moulded connectors on the other end. Benefits and Features Benefits Accurate timing + Ease of use + Speed of deployment * Blast design flexibility Features * Daisy chain connections. + Software detects and warns of detonator and harness faults + Software highlights blast design errors Quarrying Civils Special precautions + Handle with care - detonators are explosive ‘+ Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Condi Moderate temperatures and dry conditions in a well ventilated, approved magazine Product Shelf Life 36 months Legal Storage* {& months (South Nical Expiry Dated hon cscmanane 12 months (South Aca) Packaging Description Case Box Dimensions (LxBXH)__ 480 x 217 x 252mm, + Blast layout visualisation Length (ral TAB & 14S * Designed to be initiated by firing equipment specifically Townline [Surface [Unite per case | NEO Tig] designed for the HotShot system 70 5 18 0.018 Technical Properties a ~ — ea Delay time ‘Auto-Programmable - user 5 5 1s ‘a.018 needs to set inter-hole and 5 7 18 0.018 inter-row delays 15 io 18 o.oi8 Detonator strength 80 20 02 18 0.018 Water resistance Excellent 20 5 ie 278 Downline wire type Copper 4-wire: 20 i 18 018 Std [Arctic |-30°-+40" x ie He 3u8 30 32 18 o.n18 Software Versions 35 02 18 o.or8 * HotShot Standard ‘= HotShot Hybrid # HotShot + ‘* HotShot Tunnel © AEL Mining Services Limited | Product Catalogue, 2211 Transport (UN Classification) Class 1.48, UN No 0456, Product Group 2, DETONATORS, ELECTRIC Class 1.18, UN No 0030, Product Group 2, DETONATORS, ELECTRIC NUT RUN Electric Initiators - Statsafe® Detonator Statsafe is the permitted, non-incendive, short period delay electric detonator designed for use in underground coal mines where fiery conditions exist. It can also be used to initiate detonating cords, shock tube trunklines and secondary blasting, = Mining Method Underground Narrow Reef Coat Application Tunnelling Stoping Underground coal Technical Specifications Appearance An electrically initiated copper tube detonator containing two insulated copper wires with white PVC plastic crimp plug. The colour of the wires vary depending on the delay number, Benefits and Features Benefits * Circuits can be easily tested + Eight accurate delays allow choice of blasting patterns + Excellent water resistance + Lead wires are easy to deploy and handle + Passed requirements of French test for electrostatic, 10kV, 2000pF Features + Tangle-free copper lead wires + Passed the methane incendivty test + Each fusehead is protected with a plastic sleeve * Colour coded lead wires identity delay time + Standard length of 3,6 m Technical Properties Delay time 0- 300ms Bridge resistance 0.2-0.250 Firing impuls 50 - 70ms/0 Fusehead Type 1 Base Charg No. 639 PETN Safety Handling + Keep electric detonators away from all sources of electrical energy e.g. batteries, mains outlets, radios etc. ‘= Keep legwires shorted until connection into electrical blast circuit 5h Product Range Statsafe No Delay (ms) Colour 0 0 Grey and Blue 2 35 Grey and Orange 3 80 Grey and Pink, 4 10 Grey and Red 5 150 Grey and White 6 200) Blue and Green 7 250) Blue and Orange = 300) Blue and Pink Recommendations for use + Exemptions must be obtained from the inspector of mines for use of delays greater than number 5 (150ms] * Instantaneous Electric Detonators (IED) and Statsafe detonators may not be mixed in the same blast Special precautions + Handle with care - detonators are explosive * Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a welt, ventilated, approved magazine "TB months (rom sate ot manufactured Case 600 x 325 x 260mm 20 750 Transport (UN Classification) Class 1.18 UN No 0030, DETONATORS, ELECTRIC © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Electric Initiators - Instantaneous Electric Detonator (IED) The instantaneous electric detonator is used to initiate blasts by firing trunk lines of detonating cords | Mining Method or shack tube, secondary blasts and blasting gunpowder. | — Underground Narrow Reet Surface Opencast Openpit Quarrying Construction Application Stoping Secondary Blasting Technical Speci Appearance Special precautions ‘A.copper detonator with white PVC leg wires wound ine | * Handle with care - detonators are explosive figure of eight coil + Temperatures >90°C may result in spontaneous explosion * Instantaneous Electric Detonators (IED) and Statsate Benefits and Features electric detonators may not be mixed in the same blast Benefits + Lead wire insulation, ends are stripped for quick connection Storage and Expiry + Low cost, yet reliable and predictable initiation of blasts | Storage Conditions Moderate temperatures and + Excellent water resistance dry conditions in a welt ventilated, approved magazine Features Product Shelf Lit "TB months trom sate of manatee «+ Standard type 0 fusehead ‘+ Available with short tangle-free lead or copper wires + 630mg explosive PETN base charge Packaging Descri case Box Dimensions (L x B X H) 255 x 255 x 645mm Technical Properties Gross weight (kg) 20 Delay time Instantaneous Bridge wire resistance AlLfiring impulse Copper wire No fire current 0.30 A for 50ms Wire length Units per Fusehead Type to case 13 Te a 500 Recommendations for use Always keep lead wires shorted until ready to fire. Transport (UN Classification) Class 1.18, UN No 0030, DETONATORS, ELECTRIC © AEL Mining Services Limited | Product Catalogue, 2211 . eterna arene 55 NUT RUN Electric Initiators - Fusehead Assembly | Fuseheads are mainly used to initiate black powder: in dimensional stone quarries and pyrotechnic charges in fireworks, security and safety systems. Mining Method Surface Quarrying Application Quarrying Technical Specifications Appearance Special precautions Alength of white PVC covered copper wire wound in a + Handle with care fusaheads are explosive figure of eight. A standard Vulcan fuschead + Temperatures 90°C may result in spontaneous explosion ‘attached to one end, with the other wire end stripped from PVC, Benefits and Features Storage and Expiry nefits + Lead wire insulation is stripped for quick connection * Circuit can be easily tested + Ease of deployment Moderate temperatures and dey conditions in a welt ventilated, approved magazine Product Shelf Life 18 months Irom date of manufacture Features ackaei + Available with tangle-free wires Faciasing « « Standard type 0 fusehead ase ‘p Gross weight {kal 12 + Figure eight wire winding [Leading wire | Unitsper | LxBxHImmi Technical Properties (mn) ease " 78. 000 | SI5x TSX Delay time Instantaneous 35 aa Tae 030 A for 50ms Fusehead Type 0 Transport (UN Classification) Class 1.45 UN No 0454, IGNITERS *ortplreurenens ein pion 56 © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Electric Initiators - Shurstart® Shurstarts are used to electrically initiate igniter cord in development ends and underground stoping. It can also initiate pyrotechnic charges in fireworks, security and safety systems. Mining Method Underground Narrow Reef Application Tunnelling Stoping Technical Specifications Appearance Special precautions Ared plastic casing crimped onto PVC wires that are * Handle with care ~ Shurstarts are explosive 350mm in length + Always connect Shurstarts & igniter cord as shown on inner packaging. Benefits and Features Benefits ‘* Easy and secure igniter cord connector attachment ‘* Remote ignition via blasting circuit ‘Reliable and instantaneous igniter cord initiation, even under water * Circuit can easily be tested Storage and Expiry Storage Conditions Moderate ternperatures and dry conditions ina well ventilated, approved magazine Product Shelf Life 18 months from date of manufacture Features ‘+ Wires are colour coded by month for easy detection of ageing products Packaging + Plastic casing prevents water ingress Description Case + Standard type 0 fusehead Gross weight (kg) 6 ‘The plastic casing has a clip designed to retain an igniter cord strand in close proximity to the initiating pyrotechnic charge Leading wire | Unitsper | LxBXATmml tml case Technical Properties 735 750 707M Delaytime ___Instantaneous 18 125 [260x209 7% Bridge-Wire resistance 50 30 A for 60ms 05mm Wire Diameter___0.8mm__|_ transport (UN Classification) Fusehead Type Class 1.46 UN No 0325, IGNITERS © AEL Mining Services Limited | Product Catalogue, 2211 57 NUT RUN Electric Initiators - Shock Tube Starter applications. gs Technical Specifications Appearance ‘An electrically initiated aluminium detonator contained in a green plastic connector body. It has white PVC coated leg wires 1.8m in length. Benefits and Features Benefits + Excellent water resistance provided by moulded plugs and crimp. + Lead wire insulation is stripped on ends for quick connection + Reliable initiation of blasts Features + Uses Statsafe® type 1 fusehead ‘+ 1.8m tangle-free copper leading wires + Connector block to facilitate connection of up to six shock tube lines + 450mg base charge * Contains lead azide only Technical Properties Delay time Instantaneous Bridge-Wire resistance 0.2 -0.250 All firing impulse 50-70 mJ/0 Fusehead SS Typet 58 This product is mainly used to electrically initiate shack tube in both surface and underground Mining Method Underground Narrow Reef Surface Opencast Openpit Quarrying Construction Application Tunnelling Stoping Open Pit Quarrying ‘Special precautions ‘= Handle with care - detonators are explosive ‘= Temperatures >90°C may result in spontaneous explosion ‘= Do not attempt to initiate detonating cord with this product Storage and Expiry Moderate temperatures and dry conditions in a welt. ventilated, approved magazine ‘18 months trom ant st mater! Case imensions (LxBxH] 485x276x410 mm Gross weight (ka) 13 Units per case 200 Transport (UN Classification) Class 1.18 UN No 0030, DETONATORS, ELECTRIC © AEL Mining Services Limited | Product Catatgue, 2011 Electronic Initiators - NetShock™ INITIATING SYSTEMS NetShock is a revolutionary device that links the benefits of traditional shock tube systems with those of electronic blasting systems without the need to switch to electronic detonators. Technical Specifications Appearance ‘An aluminium tube which contains @ 36 Fusehead PCB electronic detonator assembly with an integrally moulded clip allowing easy connection to shock tubes, Benefits and Features Benefits + Conveys real time in-stope intelligence and reports to the central management workstation + Pre-blast diagnosis and communication of potential, safety hazards, production problems as well as the scale, location and extent of the planned blast before panels are centrally initiated to the surface Features ‘ Provides the mines with computer driven centralised blasting functionality for conventional shock tube systems + Provides pre-and post-blast diagnostics + Includes an on-board diagnostic system for safe testing + Compatible with the QuickShot centralised blasting system © AEL Mining Services Limited | Product Catalogue, 2211 Mining Method Underground Narrow Reef Massive Application Tunnelling Stoping Technical Properties Delay time Instantaneous jetonator stren Wire Diameter 3.5mm 0D Special precautions ‘= Handle with care - detonators are explosive ‘Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a welt ventilated, approved magazine ‘36 months: ‘months Expiry Date# imo sncmeam 12 months Packaging Description Case Dimensions (LxBxH] 260 x 218x 147mm Gross weight (ka) 19 NEA (kg) 0.025 Units per case 25 Transport (UN Classification) Class 1.1B, UN No, 0030, Product Group 2, DETONATORS, ELECTRIC {orp naurenrneen apt 59 NUT RUN Electronic Initiators - NetStart™ NetStart is a revolutionary device that links the benefits of traditional capped fuse and igniter cord systems with those of electronic blasting systems without the need to switch to electronic detonators. NetStart is an incendiary device conveying flame to igniter cord to initiate blasting, Technical Specifications Appearance A green-coloured, outer plastic body possessing an integrally moulded clip with a flat, yellow harness wire assembly. The plastic body contains @ 3G PCB fusehead assembly together with two pyrotechnic incendiary pellets, Benefits and Features Benefits + Provides the benefits of electronic blasting without using electronic detonators + Conveys real time in-stope intelligence and reports to the central management workstation + Pre-blast diagnosis and communication of potential safety hazards, production problems as well as the scale, location and extent of the planned blast before panels are centrally initiated to the surface Features ‘+ Provides the mines with computer driven centralised blasting functionality for conventional fuse systems + Provides pre-and post-blast diagnostics + Includes on-board diagnostic system for safe testing ‘+ Compatible with the QuickShot centralised blasting system 60 Mining Method Underground Narrow Reel Application Tunnelling Stoping Technical Properties Delay time Instantaneous Wire Diameter Flat cable 2mm Fusehead Type 20mm tr. Special precautions ‘= Handle with care - detonators are explosive ‘Temperatures >90°C may result in spontaneous explosion Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a welt ventilated, approved magazine 78 months months Expiry Datel jos saemnaan 12 months Packaging Description Case Dimensions (LxBxH] 260 x 218x 147mm Gross weight (ka) 19 NEA (kg) 0.025 Units per case 25 Transport (UN Classification) Class 1.46, UN No, 0925, IGNITERS © AEL Mining Services Limited | Product Catatgue, 2011 INITIATING SYSTEMS Initiating Accessories - Blast Current Indicator (BCI) ee A Blast Current Indicator (BCi] is @ standard Vulcan type “0” fusehead encased in a waterproof plastic body and connected to two short lead wires for easy ——. connection to a blasting circuit The BCI's are used to verity continuity and sufficient firing current transfer through the actual blasting circuit before a blast is to be fired. If use correctly, the possibility of a misfire through the circuit is significantly reduced. Technical Specifications Appearance ‘Assemi-opaque plastic body encasing a fusehead with white PVC coated leg wires 200mm in length Benefits and Features Benefits * Circuit can be easily tested «Stripped wire ends allow for quick connection ‘Waterproof ‘+ May prevent costly delays in blasting and accidents/injuries Features «Standard type 0 fusehead ‘Transparent body that blackens on firing Technical Properties Water resistance Excellent No fire current Wire Diameter Fusehead 0.5mm Type 0 © AEL Mining Services Limited | Product Catalogue, 2211 jing Method Massive Application Tunnelling Stoping ‘Special precautions «Handle with care - BCI's are explosive ‘= Temperatures >90°C may result in spontaneous explosion «= Store in a specially licensed, cool and dry area for not more than 12 months from the date of manufacture Storage and Expiry Storage Conditions Moderate temperatures and dry conditions in a welt. ventilated, approved magazine 18 months from date of manufacture months Product Sh gal Storas Packaging Case 168 x95 x 103mm Transport (UN Classification) Class 1.45 UN No 0454, IGNITERS a INITIATING Detonating Cords Mining Method Flexible cords, which detonate at more than 6 000m | Underground per second. The cords are constructed using a Narrow Reef continuous column of water-resistant pentaerythritel | SSS" tetranitrate [PETNI, wrapped in yars and overcoated Opencast with a waterproof coating, Openpit Quarrying AEL Detonating Cords are colour coded according to | Construction explosive core strength, Application Tunneling Stoning Massive (uphole} Ring Blasting Trenehing Technical Specifications Open Pit Quarrying Appearance Cis The detonating cord product range is supplied under Product Range Massive the trade name of Powercord, Three products - product petNcore] Tensile] External Powercord 6, Powercord 8 and Powercord 10 - are toad {g/milstrength (kall diameter imm) distinguished from each other by calour and by the Pomecodes} 6 sa ce mass of core load. Powercord 6 is orange in colour FSS Oe = Tate and has an explosive core load of 6g/m. Powercord 8 Powercord® 10/10 = TB52 is blue and has an explosive core load of 8g/m and Powercord 10 is yellow and has an explosive core Special precautions load of 10g/m, + Handle with care - damage to the product could lead to mistires Benefits and Features + Keep away from all sources of ignition + Avoid all forms of shock ‘« Never connect the blast until all charging operations have been completed + Keep free ends short to avoid excessive noise, shrapnel and cut-offs Benefits + Relatively insensitive to detonation by heat, electrostatic, discharge or other forms of electricity + Excellent resistance to side penetration by oll or water ‘High tensile strength + Easy to handle and to tie into knots Storage and Expiry * Flexible Storage Conc Store in an approved segregated, cool and well Features ventilated magazine VOD: = 6 000m/s. Product Shelf Life ‘S years from date of manufacture ‘* Reliably initiated with a 6D strength detonator Legal Storage* 6 months '* Easy to connect branch lines + E39y to initiate and can be extended with knots Packaging Description Case Technical Properties Prog [svatnpe Bor amenons Velocity of Detonation > 6000m/s ease (ml mom) Water resistance Excellent Powercord@® 6 | 2x 500 | S00x260x205 Penrose Pease Soci Recommendations for use Banened@ TO[ De et sone Detonating cords are used to detonate explosive charges, | [Pmacmterol ties | Samana including detonating relays, in various blasting and mining applicators: They can be used as down Ines or | Transpart (UN Classification) trunk lines and in shock tube blasts Class 1.1D UN No 0065, DETONATING CORD 62 Tesehmseeenen NIE REL Mining Services Limited | Product Catalogue, 2011 INITIATING SYSTEMS Initiating Accessories - Pentolite Primers Primers are plastic cylinders filled with a very energetic explosive, comprising of a mixture of pentaerythritol tetranitrate (PETN] and trinitrotoluene (TNT] also known as pentolite. The primers incorporate circular detonator channels that run through the mould for easy insertion of a detonator or detonating cord. The channel intended for the detonator is stepped to prevent the detonator from protruding from the primer, thus ensuring proper location inside the primer. Technical Specifications Appearance The 609, 1809, 2509, 4009 and 400g Smart pentalite primers are coloured orange, red, purple, blue and yellow respectively. Apart from colour, they are also distinguishable by size. The numbers in the product name describes the weight af Pentalite in each respective primer. Benefits and Features Benefits ‘ Relatively insensitive to detonation by impact, friction, heat, electrostatic discharge or other forms of electricity + PETN-rich composition for pick-up reliability and high VOD + Fully protected detonator + Optimum diameter-to-Length ratio for effective loading and tiation of explosives Features + The plastic body is impervious to wet conditions «+ Arange of primers that can be initiated by electronic detonators, shock tube detonators, capped fuse detonators, and detonating cords with care load of > 8g/m Mining Method Underground Narrow Reet Massive Surface Opencast Opengit Quarrying Construction Application Tunnelling Stoping Massive (uphole] Ring Blasting Trenching Open Pit Quarrying Civils Recommendations for use Pentolite Primers are used to initiate nan-cap sensitive explosives in cartridged or bulk form, Detonating cords with core load equal to or greater than g/m are recommended for effective initiation of the pentolite primer. Special precautions “Handle with care - damage tothe product may lead to mistires + Keep away from all sources of ignition ‘Temperatures in excess of 90°C may result in spontaneous, explosion + Avoid all possible sources of heat + Never connect the blast until all charging operations have been completed Storage and Expiry Storage Conditions Store in an approved segregated, cool and well ventilated magazine S years from date of manufacture Product Shelf Life eee i Storage* @ months in customer magazine + Virgin grade TNT used Packaging Technical Properties Pentttemassig) Untaper] B® recs waist ‘case | dimensions | oi Sleep time > 72 hours ‘nm? ts) Velocity of Detonation > 6000m/s og Pantatte Primer [2a [ax 360 S| Water resistance Excellent Tl Pentolte hyena} 120] ez0x 95x28 | 26 Product Range Pensalte mare ‘otour] 00 (ml | straight channel Steppe channel og Pentarte Primer [Orangel —35 cr Tb 2 130g Pentoite hyn} Rea | 38 Bh | Fao PBT Primer [50g Pentaite Primer] Purplel ab a Teas 0g Pentoite Primer| Blue | 53 Be T8962 0g Pentouite Smart | Yellow] 53 ¢ 95962 Primer © AELMinng Services Limited | Product Catalogue, 2211 Primer 250g Pentalte Primer] 80 0g Pentolite Primer] — 60) F005 Pentolte Primer] — a5 thal packl 00g Pentalte Smart] 60 Primer Transport (UN Classification) Class 1.1D UN No 0042, BOOSTERS WITHOUT DETONATOR oe en TS | Fe Buse 7774334 [26 290x790 19520 Meee tiem | — 2 63 NUN RM Initiating Accessories - Detonating Relays Detonating relays are used with detonating cord to connect successive blast holes in surface applications, where delays between holes or row of holes are. required . Mining Method Surface Opencast Openpit Quarrying Construction Application Open Pit Quarrying owls Technical Specifications Special Precautions Keep free ands of detonating cords short to prevent cut- Appearance offs or bypassing of the delay. A semi-rigid, red or green plastic housing 90mm long and 10mm thick, which has an appearance of a “dog bone”. It is fitted with two aluminium detonators Storage and Expiry containing lead delay elements. Storage Conditions Moderate temperatures and dry conditions in a welt Benefits and Features ventilated, approved magazine Benefits # 25ms and 4Oms delays available * Colour coded by delay + Compatible with 8g/m and higher core load detonating 18 months from date of manufacture ‘6 months cord Packaging Description Case Features imension (LxBxH) 300 x 295 x 545mm, + Bi-directional Gross weight (kg) 13 ‘Quick and simple connection + Easy to use Product | Colour [Units per case 25 Green 1000 Product Range 40 Red 1000 [Delay time (ms) | Colour 2 Green Transport (UN Classification) 0 Red Class 1.1B UN No 0029, DETONATORS, NON-ELECTRIC 6 © AEL Mining Services Lined | Product Catatgue, 2011 INITIATING SYSTEMS Compatibility Matrix - Packaged and Specialised Explosives Donor ielvly|vivlelel i Ivleel le Eecvomie Dea Ustvators Sra Ivlvlv[vivlvlel vl Iv lv EL Electr intore a aia aia ia aia raid ia ia as Iai i rai TEL Electron Taare fe 1 Pasi connector provided 1 Recommended © AELMinng Services Limited | Product Gata 65 NUN RM Notes 66 AEL Mining Services Lied | Product Catalogue, 201 Blasting Accessories Wealth Unearthed AEL Blasting Accessories - Mantis Is a specifically designed device to which AEL detonators are clipped. The device, with detonato is inserted into the toe of the blasthole, after which emulsion explosives or Anfex are pumped into the hole The device centralises the detonator in the middle of the hole. Technical Specifications ‘Appearance Plastic device onto which an AEL detonator is clipped. Detonator can be electronic, electric or non-electric Benefits and Features Benefits ‘+ Centralises a detonator in the blasthole ‘* Ensures retention of the detonator at the back of the blasthole ‘+ Ensures retention of the detonator in steeply inclined blastholes Features “Clip receptor for all types of AEL detonators + Resistant but flexible «Easy to insert in blasthole * Generally used in development but can be used in stoping * Designed to grip firmly onto blasthole sidewall 6a Mining Method Underground Narrow Reet Massive Application Tunnelling Stoping Recommendations for use Ensure emulsion or Anfex covers the detonator Storage and Expiry Storage Condi Product is non-explosive and can be stored in any storage location Product Shelf Life Packaging Description Case Units per case /bag 500 units per case © AEL Mining Services Lined | Product Catatgue, 2011 . %, coal mining Technical Specifications ‘Appearance Ared plastic device containing various lengths of wire with thermocouple on the end of the wire Benefits and Features Benefits ‘+ Monitors blast hole temperatures to warn operators of temperature changes in the blast hole « Alerts operators of increasing temperatures and the risk of premature detonation of a charged blast hale + Early warning safety device to improve on-bench safety n hot holes Features ‘Sounds an intermittent alarm at 600C indicating the presence of hot hole + Sounds an continuous alarm at 800C indicating that operators should evacuate ‘+ Easy lo use wire deployment system © AEL Mining Services Limited | Product Catalogue, 201 The Hot Hole Monitor is a device which monitors, temperature changes in hot holes and reduces the risk posed by premature detonation in surface Mining Method Surface Opencast Openpit Application Open Pit Recommendations for use + Ensure plastic strip is intact and secured before use to ensure that the battery is charged. + Single use only as the battery life cannot be guaranteed after the first use Storage and Expiry Storage Conditions Product is non-explosive and can be stored in any storage location Product Shelf Life Dependant of battery life Packaging Description Case Units per case /bag 30 units per case Transport (UN Classification) NIA 69 70 AEL Mining Services Lied | Product Catalogue, 201 Industrial Products Wealth Unearthe AEL industrial is recognised as a logistical leader in the industrial solutions arena and, with strong African supply footprints, the company effectively addresses requirements in South Africa, Afr international markets. With direct access to AEL’s large team of leading engineers and scientists, the industrial products division is, in a position to offer a broader range of highly versalile industrial solutions, which perform well against strict quality parameters and incorporate major innovations (such as curing before bagging) that add to the structural, integrity of the product and ensure better end results. In fact, it is AEL’s innovative approach to product betterment and its constant monitoring of industrial updates that has enabled it to ensure a 50 percent reduction in expected failure rates, The range includes Ammonium Nitrate (ANI, acids and ammonia-based solutions, all of which are conveniently sourced from AEL's industrial hub in Gauteng, are known for their consistency when it comes to product quality and are effectively supported by a team of highly skilled staffers. ‘At the base of every mine operation is a solid supply of reliable, high quality industrial products. Without products, like those provided by this division, very little would move and it is being a consistent and reliable provider of industrial products and solutions that AEL has positioned a and selected itself as the leading supplier inthis space. The industrial products division employs the highly skilled Research and Development facilities within AEL’s structure as wellas advanced manufacturing technologies. to ensure ongoing improvement in its product performance. The industrial products division offers a proven track record in dispatch efficiency and in product containment and handling, and customers acknowledge the department for not only its high quality product offering and effective administrative systems, but also for its ethical behaviour when it comes to orders and deliverables, AEL’s industrial products division is prepared for any eventuality and is proud to be able to say that it can and will continue to effectively address all of its customer's requirements in the industrial solutions arena, whilst maintaining its already high levels of customer service and technical support. = Wining Services INOS m coe oi Ammonium Nitrate Anfo Grade (ANA) Essentially ammonium nitrate (NH4NO3) presented in the form of coarse, porous, hardened spherical particles, obtained by spraying the melted material. The material is treated with an anti-caking agent. Application Bulk Anfo explosives Technical Specifications Appearance Special precautions The material is presented in the form of free-flowing, ANA is moderately toxic and may decompose under white to cream-coloured, spherical particles free from confinement and high temperature - under extreme art, visible impurities and foreign matter. conditions an explosion may occur. Benefits and Features Benefits Storage and Expiry + Reduced caking and improved flowability Storage Conditions ANAis extremely hydroscopic + High level of oil absorption and must be stored in a cool, + Prill format offering storage and handling benefits dry and unconfined space ~ * Consistent product quality avoid contamination with + Reduced dust during handling incompatible mater ProductShelfLife Sixmonths_ Features lange Pactasing + Superior prill with reduced friabilty and moisture content |< + Sieving out of fine particles * 50kg + 10009 1 200g Technical Properties Bulk SCS Bulk tanker Appearance Coarse, porous, hardened spherical + Rapid Reloading System particles (RRS) Concentration Not less than 99.5% (m/mlas Rail ammonium nitrate (when packed) I Bue deraiy To uehn Ue range 07 To TTaen® | Mansport (UN Classification) ‘Moisture Less than0.2% _ Class 5.1 UN No 1942 OXIDISING AGENT R AEL Mining Services Lied | Product Catalogue, 201 NLU Umea Ammonium Nitrate Emulsion Grade (ANE) Technical Specifications Appearance ‘The material is presented in the form of glossy white spherical particles free from visible impurities and foreign matter. Benefits and Features Benefits ‘= Reduced caking and improved flowability * Conveniently situated close to mining centres ‘+ Improved transport and storage efficiencies ‘= No flocculation required after melting prior to emulsion manufacture Consistent product quality Features ‘Superior prill with reduced friability and moisture ‘High packing density Technical Properties Appearance Glossy-white spherical particles Concentration Notless than 94.2% Im/mlas ammonium nitrate {when packed) To lie within the range 0.80 to 0.97 gfem? Bulk density © AEL Mining Services Limited | Product ANE is dense ammonium nitrate particles obtained by spraying the melted product and used in the manufacture of emulsion matrix. Application Manufacture of emulsion Special precautions ANE is moderately toxic and may decompose under confinement and high temperatures under extreme conditions an explosion may occur Storage and Expiry Storage Conditions ANE is extremely hygroscopic and must be stored in a cool, dry and unconfined space. Avoid contamination with organic materials Product Shelf Life ‘Six months Packaging Packed in robust woven polypropylene bags with inner polyethylene liners to minimise moisture ingress All bags have UN certification and conform to international requirements Bags: 1 050kg; 1 200kg Transport (UN Classi dn) Class 5.1 UN No 2067 OXIDISING AGENT 3 INOS m coe oi Ammonium Nitrate Solution (ANS) Acconcentrated aqueous solution of ammonium. nitrate (NHéNOs} used in the manufacture of ‘emulsion matrix. Truck leasing ANS, Application * Manufacture of emulsion matrix tilser raw material Technical Specifications Appearance Special precautions A concentrated aqueous solution of ammonium nitrate [ANS may become explosive after dewatering, itis (NH RSeries ‘Arepump MMU capable of pumping bulk of requested product quality/quantity emulsion products. « Acange of products can be apalied on one bench depending on | *WSeries~Aneawy ANFO MMU capable of auguring conditions AANFO and the full range of AEL's blended + Varying pumping and auguring rates to suit bench hole explosives products diameters and conditions Tasers ’An MMU capable of auguring ANFO. + Minimal on-bench product spls during start-uo/shut-down | Broduct Range operations Features, le + Pump protection-guarding against dead-heading and dry-running if rainers on the bin to prevent ingress of foreign abjects | * Closed top hydraulic contrl system guarantees product quality EI + in-cab touch-screen user interface EI * Suitable chassis with all standard safety devices selected for FI rugged on-bench conditions | a Rate GTMIAT Safety Features z | + Independent electronic pump protection system monitoring and 3 | cantrollng operating pressures and temperatures on ertical | umps KE + Mechanical pump protection devices installed onal rtcal pumps ls + Emergency stops situated at critical locations ou yp IE iijarautcaly operated posite locking handrits provide safe [AELESSHASRHD : peration when access fo top of truck required a ZS felsteleleleiele AE Rare ar r a fereots Technical Properties a7 ia EGaoe + Closed oop hyrautc system ASL Saco Singependent pur ste contol system 22} ae lee ee 4 Max Augering rate of 750kg/min on blend and ANFO a ft — froma : products «in cab electrical control panel Recommendations for use * Toueh-screen user interface Opencast mining operations witha requirement forall bulk ¢ Siemens PLC Control explosives products 8 AEL Mining Services Lied | Product Catalogue, 201 Mobile Charging Units (MCUs) AEL. provides a full range of Mobile Charging Units [MCUs], which cater for all underground mining applications. MCUs are capable of pumping the full range of AEL’s bulk explosives products. AIL MCUs are designed to operate in the demanding environments encountered during normal mining operations. Design parameters include all necessary safety control systems, as well as ease of operation, maintenance and reliability. Units are of a modular design and are able to be ‘mounted on all Utility Vehicles supplied or preferred by the customer. Technical Specifications Benefits and Features Benefits + Proven reliability in all charging applications + Integrated control systems, which guarantee constant delivery of requested product quality/quantity + Arrange of products can be applied depending on conditions + Product pumping rates reduce face/panel charging times, ‘+ Minimal product spills during start-up/shut-down operations Features ‘= Pump protection-guarding against dead-heading and dry-running scenarios « Strainers on the bin to prevent ingress of foreign objects Remote contral by pendant ‘= Unit capable of pumping at elevated heights. ‘© Charging units can be mounted on all utility vehicles. Safety Features ‘Independent electronic pump protection system monitoring and controlling operating pressures on critical pumps ‘+ Mechanical pump protection devices installed on all critical pumps ‘+ Emergency stops situated at critical locations + Up-hole charging from a safe distance via remote control pendant (MCU Jumbo} + Units have a meltable sight-glass on emulsion tank, which ruptures when exposed to heat Recommendations for use Underground mining operations with a requirement for all bulk explosives products © AEL Mining Services Limited | Product Catalogue, 201 Product Range Underground Mobile Charging Units (MCU) MCU LST H/E/etc H = Hydraulic lectric HE = Electric Power Pack A= Pneumatic lectric erimeter Blasting B = Direct Drive on Cat Pumps rect Drive on Product Pump MCU OTST LCB = Direct Drive on Cat Pumps UC = Land Cruiser Unit Jumbo = Up/Down Hole Charging Ui jirect drive on orbit pump neumatic hydraulic over electric shaft sinking land cruiser uphole charging MCU 2T H/E/ete MCU ST H/E/ete MCU Jumbo Technical Properties + Hydraulic system supplied from utility vehicle ranged from 20 ~ 100 titres per minute at 160 bar ‘+ Independent pump safety control system ‘+ Max pumping rates range between 30 and 80kg per minute ‘User-friendly control panel - operator interface ‘Fully automated hose handling system [MCU Jumbol + PLC controlled system operating from 12 or 24 volt DC 85 EQUIPMENT SERVICE! Equipment Services - Portable Charging Unit (PCU] AEL. provides the PCU08 pump for charging in narrow reef mining environments. The D> pump has been specifically designed to pump the UG100 and UG200 non-sticky range of AEL’s bulk explosives products in conjunction with an emulsified sensitiser in stoping and development blast holes, The PCUOB is robust and reliable and is designed to operate in the demanding environments usually encountered in underground mining operations. Technical Specifications Application Used for charging bulk emulsion in underground narrow reef mining environments. The focus area for the PCUO8 pump is narrow reef stoping. However, the pump can also be used in standard development up to four metres in height and width. The pump is generally used in conjunction with bagged emulsion. Benefits and Features Benefits + Robust and reliable + Lightweight + Accurately batches a nominated mass + Product in hose is non-detonable + One man charging operation with trigger on lance + Flexible hose / tance for use in confined spaces (optional) 86 Features ‘Electric PCU08 pump used in conjunction with Hilt Dril, Hilti drill is power source and K required + Compressed air driven ‘Trigger at pump and at lance [optional] + Made of plastic and is lightweight + Fixed batch or continuous delivery mode + Easy to use and maintain Safety Features '* Bursting dise ‘* Components contained within sealed lid AEL Mining Services Lied | Product Catalogue, 201 Emulsion Plant 107, 207 EQUIPMENT SI AEL's 207 Batch Emulsion Plants consist of two modules - an Ammonium Nitrate Dissolving Module and an Emulsion Manufacturing Module AEL provides two sizes of emulsion plants [107 and 207 per eight-hour shift. These plants are capable of producing the full range of AEL's bulk explosives products, including surface and underground products. The emulsion plants are designed to operate in the demanding environments encountered during normal mining operations. Design parameters include all necessary safety control systems, as well as ease of operation, maintenance and reliability. Technical Specifications Benefits and Features Benefits + Proven reliability in remote sites, + Integrated control systems which guarantee constant delivery of quality product + Arange of products can be produced by a single plant. + Emulsion Plants are designed to be “Zero Effluent plants, Features ‘= Pump pratection-guarding against dead-heading and dry-running scenarios + Strainers in the suction line to prevent ingress of foreign objects * Closed loop hydraulic control system guarantees product quality ‘* In-plant touch-screen user interface ‘+ Modular Plant built into standard size containers to facilitate the transportation and installation on remote sites, Safety Features + Independent electronic pump protection system monitoring and controlling operating pressures end temperatures on critical pumps ‘+ Mechanical pump protection devices installed on all critical pumps. + Temperature control systems installed on emulsion dissolving module. + Emergency stops situated at critical locations. © AEL Mining Services Limited | Product Catalogue, 201 Technical Properties + Closed loop hydraulic system + Independent pump safety control system + Max Production rate of 350 Kg/min + In plant electrical control panel + Touch-sereen user interface + Siemens PLC Control Recommendations for use Opencast and Underground mining operations with a requirement for bulk explosives products, 87 NAW) In tine with International trends we've reviewed our product names, below is alist of old and new names, LT Initiating Systems Old name New name Reefmaster® Assembly Shock tubs jelay LP Splitter Assembly ‘Shock lube - Splitter Stopemaster® Assembly/ Shock tube - Multi SPD Benchmaster® Assembly Shock tube - Multi LPD ‘Shock tube - Uni-Delay SP Tunnelmaster® Assembly Handimaster™ Assembly / Dualmaster Handimaster™ Trundline Delay Assembly/Trunkmaster Shock tube - Trunkline Noisemaster® Trunkline Delay Assembly Noisemaster® Lead-in Assembly Shock lube - Cluster ‘Shock tube - Lead-in Noisemaster® Extender Shock tube - Extender Old name New name Vulcan Fusehead Assembly Electric Iniiators - Fusehead Assembly Shurstan® Electric Intiators - Shurstarr® Electric Handistart® Electric Intiatars - Shock tube Starter NetShock™ Electronic Initiators - NetShock™ NetStare™ Electronic Initiators - NetStart™ Blast Current Indicator (BC!) Blast Current Indicator (8CI), Cobracord® Powercord® & Powercord® Powercord® 8 Cordtex® 10 Powercord® 10 Stopefuse® 290 Capped Fuse Systems - Stopeluse® Duratuse® Capped Fuse Systems - Duratuse® Masterstarter® Capped Fuse Systems - Shock tube Starter 60g Prabaost™ Booster 60g Pentelite Primer 150g Hybrid Booster 150g Pentolite Primer - Hybrid 250g Booster 2809 Pentoite Primer 400g Booster 400g Pentolite Primer 400g Smartdet® Booster 400g Pentolite Primer - Smart Stopeline® Capped Fuse Systems stonstng Rela Detonating Rein Stopeline® dew ig Relays: 1g Relays Stopeline® Capped Fuse Systems - Stopeline® 9 Explosives Duraline™ Capped Fuse Systems Dorin Surface Bulk Emulsion 9100 Slowtine® Sanpete er coin ece Synergy® 100/P100 100 uiekShor™ Plus Electron Delay Detonators uewsrat™ Pius Synergy® 120/ Pa00 sia ‘Smartdet® Electronic Delay Detonators - ‘Syneray® 130/ P600 S130) Serartdet® Synergy® 195 P700 5195 smartShot™ Electronic Delay Detonators- Synergy® 400 S00 Eco SmartShat™ Syneroy® 420 8120 Feo Digishat™ Electronic Delay Detonators - Syneray@ 439 S188 Eco Digshot™ DigShot™ Plus Elecironic Delay Detonators - Dighot™ Pius Howse Elecrone Delay Detoators--—-‘UNerground Bulk Emulsion Htshot™ sop us100 Carrick® Statsafe® Electric initiators - $05. tug100 Statsafe® Detonators UG100s [New Product Instantaneous Electric Electric Initiators - R1006 UG200 Detonator (E01 Instantaneous Electric 1000 tus2008 Detonator IED) 88 © AEL Mining Services Lined | Product Catatgue, 2011 SS Packaged Explosives Old name New name Magnum” Buster Magaum™ Buster Magnum” Buster Gel Magnum! Buster Gel Magnum™ 365 Gel Magaum™ 265 Gel Magnum Control Magnum" Control Magnumn™ Frag Magaum™ Frag Mognum™ Plus Magnumn™ Plus “AEL Mining Services has retaines the Magnum Trademark and wl Specialised Explosives Energex Barr! PE Barrel Blasting Gunpowder Blasting Gunpowder Industrial Products Oldname New name [Aramanium Nitrate Aramonium Nitrate Ant Porous Pil [ANPP) Grade [ANA] Free Flowing Ammenium Ammonium Nitrate Nitrate [Anton Emulsion Grace (ANE) -Aramanium Nitrate ‘Aramonium Nitrate Solstion [ANS] Salution (ANS) Nite Aca 60% Nitrie Acid 60% Nitric Acid 99 Nite Acid 99% Nitric Acie 96% Nite Acid 96% Ammonia Selution 25% ‘Aqueous Ammonia Anhysrous Ammonia “Ammonia 100-1 Industral Grade Anhydrous Ammania ‘Aramonis 100-R Refrigerated Grece Blasting Accessories Mantis Mantis Hot Hole Detector Hot Hole Monitor Equipment Services Mobile Manufacturing Units Mobile Manufacturing Units wav} Mmu) Mobile Charging Units [MCU's]_ Mobile Charging Units (MCU's} Equipment services Perial Equipment services Portable Charging Units [PCU! Charging Units (PCUL Emulsion Plant 107, 20 Emulsion Plant 107, 207 © AEL Mining Services Limited | Product Catalogue, 201 Notes PRODUCT NEW eS 89

You might also like